In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division m...In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division multiple access (DS-CDMA) receiver with frequency-selective Rayleigh fading. This receiver consists of three stages. In the first stage, with constrained least mean squared (CLMS) algorithm, the desired users’ signal in an arbitrary path is passed and the inter-path interference (IPI) is reduced in other paths in each RAKE finger. Also in this stage, the multiple access interference (MAI) from other users is reduced. Thus, the matched filter (MF) can use for more reduction of the IPI and MAI in each RAKE finger in the second stage. Also in the third stage, the output signals from the matched filters are combined according to the conventional maximal ratio combining (MRC) principle and then are fed into the decision circuit of the desired user. The simulation results indicate that the SSPC algorithm and the BSA-MTP technique can significantly reduce the network bit error rate (BER) compared to the other methods. Also, we observe that significant savings in total transmit power (TTP) are possible with our methods.展开更多
The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we prop...The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we propose smart step closed-loop power control (SSPC) algorithm in wireless networks in a 2D urban environment with constrained least mean squared (CLMS) algorithm. This algorithm is capable of efficiently adapting according to the environment and able to permanently maintain the chosen frequency response in the look direction while minimizing the output power of the array. Also, we present switched-beam (SB) technique for enhancing signal to interference plus noise ratio (SINR) in wireless networks. Also, we study an analytical approach for the evaluation of the impact of power control error (PCE) on wireless networks in a 2D urban environment. The simulation results indicate that the convergence speed of the SSPC algorithm is faster than other algorithms. Also, we observe that significant saving in total transmit power (TTP) are possible with our proposed algorithm. Finally, we discuss three parameters of the PCE, number of antenna elements, and path-loss exponent and their effects on capacity of the system via some computer simulations.展开更多
Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency devia...Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency deviations,voltage fluctuations,and poor reactive power coordination,posing serious challenges to grid stability.Conventional Interconnection FlowControllers(IFCs)primarily regulate active power flowand fail to effectively handle dynamic frequency variations or reactive power sharing in multi-microgrid networks.To overcome these limitations,this study proposes an enhanced Interconnection Flow Controller(e-IFC)that integrates frequency response balancing and an Interconnection Reactive Power Flow Controller(IRFC)within a unified adaptive control structure.The proposed e-IFC is implemented and analyzed in DIgSILENT PowerFactory to evaluate its performance under various grid disturbances,including frequency drops,load changes,and reactive power fluctuations.Simulation results reveal that the e-IFC achieves 27.4% higher active power sharing accuracy,19.6% lower reactive power deviation,and 18.2% improved frequency stability compared to the conventional IFC.The adaptive controller ensures seamless transitions between grid-connected and islanded modes and maintains stable operation even under communication delays and data noise.Overall,the proposed e-IFCsignificantly enhances active-reactive power coordination and dynamic stability in renewable-integrated multi-microgrid systems.Future research will focus on coupling the e-IFC with tertiary-level optimization frameworks and conducting hardware-in-the-loop validation to enable its application in large-scale smart microgrid environments.展开更多
To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hyb...To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hybrid modular multilevel converter–capacitor-commutated line-commutated converter(MMC-CLCC)HVDC transmission system and its corresponding control strategy.First,the system topology is constructed,and a submodule configuration method for the MMC—combining full-bridge submodules(FBSMs)and half-bridge submodules(HBSMs)—is proposed to enable direct power flow reversal.Second,a hierarchical control strategy is introduced,includingMMCvoltage control,CLCC current control,and a coordinationmechanism,along with the derivation of the hybrid system’s power flow reversal characteristics.Third,leveraging the CLCC’s fast current regulation and theMMC’s negative voltage control capability,a coordinated power flow reversal control strategy is developed.Finally,an 800 kV MMC-CLCC hybrid HVDC system is modeled in PSCAD/EMTDC to validate the power flow reversal performance under a high proportion of full-bridge submodule configuration.Results demonstrate that the proposed control strategy enables rapid(1-s transition)and smooth switching of bidirectional power flow without modifying the structure of primary equipment:the transient fluctuation ofDC voltage from the rated value(UdcN)to themaximumreverse voltage(-kUdcN)is less than 5%;the DC current strictly follows the preset characteristic curve with a deviation of≤3%;the active power reverses continuously,and the system maintains stable operation throughout the reversal process.展开更多
The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,...The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units.展开更多
Grid-forming(GFM)control is a key technology for ensuring the safe and stable operation of renewable power systems dominated by converter-interfaced generation(CIG),including wind power,photovoltaic,and battery energy...Grid-forming(GFM)control is a key technology for ensuring the safe and stable operation of renewable power systems dominated by converter-interfaced generation(CIG),including wind power,photovoltaic,and battery energy storage.In this paper,we challenge the traditional approach of emulating a synchronous generator by proposing a frequency-fixed GFM control strategy.The CIG endeavors to regulate itself as a constant voltage source without control dynamics due to its capability limitation,denoted as the frequency-fixed zone.With the proposed strategy,the system frequency is almost always fixed at its rated value,achieving system active power balance independent of frequency,and intentional power flow adjustments are implemented through direct phase angle control.This approach significantly reduces the frequency dynamics and safety issues associated with frequency variations.Furthermore,synchronization dynamics are significantly diminished,and synchronization stability is enhanced.The proposed strategy has the potential to realize a renewable power system with a fixed frequency and robust stability.展开更多
This paper proposes a separated trajectory tracking controller for fishing ships at sea state level 6 to solve the trajectory tracking problem of a fishing ship in a 6-level sea state,and to adapt to different working...This paper proposes a separated trajectory tracking controller for fishing ships at sea state level 6 to solve the trajectory tracking problem of a fishing ship in a 6-level sea state,and to adapt to different working environments and safety requirements.The nonlinear feedback method is used to improve the closed-loop gain shaping algorithm.By introducing the sine function,the problem of excessive control energy of the system can be effectively solved.Moreover,an integral separation design is used to solve the influence of the integral term in conventional PID controllers on the transient performance of the system.In this paper,a common 32.98 m large fiberglass reinforced plastic(FRP)trawler is adopted for simulation research at the winds scale of Beaufort No.7.The results show that the track error is smaller than 3.5 m.The method is safe,feasible,concise and effective and has popularization value in the direction of fishing ship trajectory tracking control.This method can be used to improve the level of informatization and intelligence of fishing ships.展开更多
Rotary steering systems(RSSs)have been increasingly used to develop horizontal wells.A static push-the-bit RSS uses three hydraulic modules with varying degrees of expansion and contraction to achieve changes in the p...Rotary steering systems(RSSs)have been increasingly used to develop horizontal wells.A static push-the-bit RSS uses three hydraulic modules with varying degrees of expansion and contraction to achieve changes in the pushing force acting on the wellbore in different sizes and directions within a circular range,ultimately allowing the wellbore trajectory to be drilled in a predetermined direction.By analyzing its mathematical principles and the actual characteristics of the instrument,a vector force closed-loop control method,including steering and holding modes,was designed.The adjustment criteria for the three hydraulic modules are determined to achieve rapid adjustment of the vector force.The theoretical feasibility of the developed method was verified by comparing its results with the on-site application data of an imported rotary guidance system.展开更多
Conventional open-loop deep brain stimulation(DBS)systems with fixed parameters fail to accommodate interindividual pathological differences in Parkinson's disease(PD)management while potentially inducing adverse ...Conventional open-loop deep brain stimulation(DBS)systems with fixed parameters fail to accommodate interindividual pathological differences in Parkinson's disease(PD)management while potentially inducing adverse effects and causing excessive energy consumption.In this paper,we present an adaptive closed-loop framework integrating a Yogi-optimized proportional–integral–derivative neural network(Yogi-PIDNN)controller.The Yogi-augmented gradient adaptation mechanism accelerates the convergence of general PIDNN controllers in high-dimensional nonlinear control systems while reducing control energy usage.In addition,a system identification method establishes input–output dynamics for pre-training stimulation waveforms,bypassing real-time parameter-tuning constraints and thereby enhancing closed-loop adaptability.Finally,a theoretical analysis based on Lyapunov stability criteria establishes a sufficient condition for closed-loop stability within the identified model.Computational validations demonstrate that our approach restores thalamic relay reliability while reducing energy consumption by(81.0±0.7)%across multi-frequency tests.This study advances adaptive neuromodulation by synergizing data-driven pre-training with stability-guaranteed real-time control,offering a novel framework for energy-efficient and personalized Parkinson's therapy.展开更多
The integration of cognitive radio and energy has enhanced the utilization efficiency of the spectrum and promoted the application of green energy.To begin with,this paper presents the architecture of green energy-eff...The integration of cognitive radio and energy has enhanced the utilization efficiency of the spectrum and promoted the application of green energy.To begin with,this paper presents the architecture of green energy-efficient communication and network models.It incorporates the distributed network model and the heterogeneous two-tier network model into the green cognitive radio power control and channel allocation model.The primary focus of this research lies in energy conservation at the physical layer.To mitigate the interference with primary users and address the peak constraint in secondary user power allocation,the article analyzes the system model of the cognitive radio network and subsequently elaborates on the dynamic throughput maximization allocation algorithm.Eventually,through experimental analysis and verification,the distinctiveness and comprehensiveness of the optimal power control for this subject are illustrated.展开更多
Dear Editor,This letter investigates the grid-forming control for power converters.Recently,grid-forming control based on matching of synchronous machines was suggested by using continuous measurements.In the present ...Dear Editor,This letter investigates the grid-forming control for power converters.Recently,grid-forming control based on matching of synchronous machines was suggested by using continuous measurements.In the present letter,we suggest a digital implementation using artificial delays where the controller employs the discrete-time measurements only.展开更多
Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper ...Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.展开更多
Modern shipboard microgrids(SMGs)incorporating distributed energy resources(DERs)enhance energy resilience and reduce carbon emissions.However,the hierarchical control schemes of DERs bring challenges to the tradition...Modern shipboard microgrids(SMGs)incorporating distributed energy resources(DERs)enhance energy resilience and reduce carbon emissions.However,the hierarchical control schemes of DERs bring challenges to the traditional power flow methods.This paper devises a generalized three-phase power flow approach for SMGs that integrate hierarchically controlled DERs.The main contributions include:(1)a droop-controlled three-phase Newton power flow algorithm that automatically incorporates the droop characteristics of DERs;(2)a secondary-controlled three-phase power flow method for power sharing and voltage regulation;and(3)modified Jacobian matrices to incorporate various hierarchical control modes.Numerical results demonstrate the effectiveness of the devised approach in both balanced and unbalanced three-phase hierarchically controlled SMG systems with arbitrary config-urations.展开更多
This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multipl...This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.展开更多
The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to e...The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to external conditions such as PV panel shading,PV component damage,can lead to PV output power imbalance,triggering the system over-modulation phenomenon,which in turn leads to grid-connected current waveform distortion.To this end,an improved power balance control strategy is proposed in this paper.Firstly,according to the different modulation ratios of each H-bridge module,a suitable harmonic injection method is used to keep the peak value of the modulating waveform always at 1;then an inverse triangular trapezoidal waveform is injected to optimize the modulating waveform,which further improves the output voltage waveform,reduces the THD value of the grid-connected currents,and maintains the stability of power inside the CHB system.Purpose.Simulation verifies the effectiveness and feasibility of this power balance control strategy.展开更多
Conventional droop control in multi-parallel grid-forming inverters exhibits poor reactive power sharing accuracy due to line impedance mismatches.In this study,we proposed a coordination control strategy integrating ...Conventional droop control in multi-parallel grid-forming inverters exhibits poor reactive power sharing accuracy due to line impedance mismatches.In this study,we proposed a coordination control strategy integrating adaptive virtual impedance with dynamic Q-V droop regulation to overcome this issue.We established a coupling model between the line impedance and power allocation to determine the quantitative relationship between reactive power deviation and impedance difference and to analyze the mechanism of reactive power deviation formation.Based on this,we proposed a transformer neural network-based online identification method for adaptive virtual impedance and dynamic droop coefficients.The self-attention mechanism dynamically characterizes the spatial distribution features of the impedance parameters considering the real-time voltage/reactive power time-series data as inputs to realize the dynamic impedance compensation without communication interaction.The contradiction constraint between the voltage drop and distribution accuracy caused by the introduction of conventional virtual impedance is improved by dynamic droop coefficient reconstruction.Lastly,we established a hardware-in-the-loop simulation platform to experimentally validate the operational efficacy and dynamic performance of the proposed control strategy under various grid scenarios.展开更多
This study investigates the Maximum Power Point Tracking(MPPT)control method of offshore windphotovoltaic hybrid power generation system with offshore crane-assisted.A new algorithm of Global Fast Integral Sliding Mod...This study investigates the Maximum Power Point Tracking(MPPT)control method of offshore windphotovoltaic hybrid power generation system with offshore crane-assisted.A new algorithm of Global Fast Integral Sliding Mode Control(GFISMC)is proposed based on the tip speed ratio method and sliding mode control.The algorithm uses fast integral sliding mode surface and fuzzy fast switching control items to ensure that the offshore wind power generation system can track the maximum power point quickly and with low jitter.An offshore wind power generation system model is presented to verify the algorithm effect.An offshore off-grid wind-solar hybrid power generation systemis built in MATLAB/Simulink.Compared with other MPPT algorithms,this study has specific quantitative improvements in terms of convergence speed,tracking accuracy or computational efficiency.Finally,the improved algorithm is further analyzed and carried out by using Yuankuan Energy’s ModelingTech semi-physical simulation platform.The results verify the feasibility and effectiveness of the improved algorithm in the offshore wind-solar hybrid power generation system.展开更多
AIM:To observe the effect of the plus power ring zone(PPRZ)area and distribution on myopia progression.METHODS:This retrospective study enrolled 137 pre-teens aged 8-12 at Taiyuan Aier Eye Hospital between 2019 and 20...AIM:To observe the effect of the plus power ring zone(PPRZ)area and distribution on myopia progression.METHODS:This retrospective study enrolled 137 pre-teens aged 8-12 at Taiyuan Aier Eye Hospital between 2019 and 2021.They were fitted with Ortho-K lenses for the first time due to refractive error,with a one-year follow-up period.To indicate the peripheral plus ring zone overlapping with the pupil zone(PPROPZ)accompanying PPRZ,participants were divided based on the PPROPZ to PPRZ ratio.The experimental group had 103 eyes with a PPROPZ to PPRZ ratio of≥0.2,and the control group had 103 eyes with a ratio of<0.2.Participants had a spherical diopter in the range of-6.00 D to-0.75 D,against-the-rule astigmatism less than 1.00 D,with-the-rule astigmatism less than 1.50 D,and corneal curvatures of 39.00 D to 46.00 D.They had a stable best corrected visual acuity of 0.10 LogMAR(20/25)or better when wearing orthokeratology(Ortho-K)lenses.PPRZ and PPROPZ were measured using ImageJ;corneal topography assessed corneal-related parameters,and an optical biometer measured the axial length of the eyes pre and post-one years of lens wear.RESULTS:Changes in axial length elongation were found to decrease when either the PPRZ(P<0.01)or PPROPZ(P<0.001)was increased significantly.The axial length growth was faster in the control group(0.37±0.2 mm)than in the experimental group(0.21±0.11 mm).Furthermore,we found that a larger horizontal visible iris diameter(HVID)corresponded to slower axial growth of the eye.In contrast,axial length growth showed no correlation with surface regularity index(SRI),surface asymmetry index(SAI),flat keratometry value(K_(f)),steep keratometry value(K_(s)).CONCLUSION:For orthokeratology,wearers with larger PPROPZ to PPRZ ratio usually experiences a reduction in axial length growth.The PPRZ and PPROPZ are negatively correlated with the axial length.Our findings provide a recommendation and methods for studying the myopia control mechanism through Ortho-K lenses.展开更多
Driven by the global energy transition and carbon neutrality targets,alkaline water electrolysis has emerged as a key technology for coupling variable renewable generation with clean hydrogen production,offering consi...Driven by the global energy transition and carbon neutrality targets,alkaline water electrolysis has emerged as a key technology for coupling variable renewable generation with clean hydrogen production,offering considerable potential for absorbing surplus power and enhancing grid flexibility.However,conventional control architectures typically treat the power converter and electrolyzer as independent units,neglecting their dynamic interactions and thereby limiting overall system performance under practical operating conditions.This review critically examines existing control approaches,ranging from classical proportional-integral schemes to model predictive control,fuzzy-logic algorithms,and data-driven methods,evaluating their effectiveness in managing dynamic response,multivariable coupling,and operational constraints as well as their inherent limitations.Attention is then focused on the performance requirements of the hydrogen-production converter,including current ripple suppression,rapid transient response,adaptive thermal regulation,and stable power delivery.An integrated co‑control framework is proposed,aligning converter output with electrolyzer demand across steady-state operation,variable renewable input,and emergency shutdown scenarios to achieve higher efficiency,extended equipment lifetime,and enhanced operational safety.Finally,prospects for advancing unified control methodologies are outlined,with emphasis on constraint-aware predictive control,machine-learning-enhanced modeling,and real‑time co‑optimization for future alkaline electrolyzer systems.展开更多
The proton exchange membrane fuel cell(PEMFC)and the hydrogen hybrid power system are studied by the fuzzy-PID(FPID)controlmethod and the fuzzy-PID controlmethod by Artificial Bee Colony algorithm(ABCFPID),respectivel...The proton exchange membrane fuel cell(PEMFC)and the hydrogen hybrid power system are studied by the fuzzy-PID(FPID)controlmethod and the fuzzy-PID controlmethod by Artificial Bee Colony algorithm(ABCFPID),respectively.The results reveal that compared with the FPID control method,the temperature overshoot of the PEMFC stack under the ABC-FPID control method is decreased by 0.6%.Moreover,the circulating water flow rate within the full operating envelope(about 3 min)is reduced by 19.46 L,which means the ABC-FPID control method is more effective in regulating the stack temperature.Then,the ABC-FPID control method is proposed to study the hydrogen hybrid power system,and the system output power matching,operating characteristic curve of the fuel cell,state of charge(SOC)of the lithium battery,system efficiency and hydrogen demand are obtained.The results indicate that the maximum system efficiency reaches 46.3%,the average system efficiency is 33.8%,and the average hydrogen demand is 0.192 kg/s.Overall,the ABC-FPID control method can efficiently ensure the stability of the fuel cell’s output power,and actively prompt the lithium battery to fulfill the function of“peak shaving and valley filling”under variable load power conditions.展开更多
文摘In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division multiple access (DS-CDMA) receiver with frequency-selective Rayleigh fading. This receiver consists of three stages. In the first stage, with constrained least mean squared (CLMS) algorithm, the desired users’ signal in an arbitrary path is passed and the inter-path interference (IPI) is reduced in other paths in each RAKE finger. Also in this stage, the multiple access interference (MAI) from other users is reduced. Thus, the matched filter (MF) can use for more reduction of the IPI and MAI in each RAKE finger in the second stage. Also in the third stage, the output signals from the matched filters are combined according to the conventional maximal ratio combining (MRC) principle and then are fed into the decision circuit of the desired user. The simulation results indicate that the SSPC algorithm and the BSA-MTP technique can significantly reduce the network bit error rate (BER) compared to the other methods. Also, we observe that significant savings in total transmit power (TTP) are possible with our methods.
文摘The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we propose smart step closed-loop power control (SSPC) algorithm in wireless networks in a 2D urban environment with constrained least mean squared (CLMS) algorithm. This algorithm is capable of efficiently adapting according to the environment and able to permanently maintain the chosen frequency response in the look direction while minimizing the output power of the array. Also, we present switched-beam (SB) technique for enhancing signal to interference plus noise ratio (SINR) in wireless networks. Also, we study an analytical approach for the evaluation of the impact of power control error (PCE) on wireless networks in a 2D urban environment. The simulation results indicate that the convergence speed of the SSPC algorithm is faster than other algorithms. Also, we observe that significant saving in total transmit power (TTP) are possible with our proposed algorithm. Finally, we discuss three parameters of the PCE, number of antenna elements, and path-loss exponent and their effects on capacity of the system via some computer simulations.
基金the Deanship of Scientific Research at Northern Border University,Arar,Saudi Arabia,for funding this research work through the project number“NBU-FFR-2025-3623-11”.
文摘Modern power systems increasingly depend on interconnected microgrids to enhance reliability and renewable energy utilization.However,the high penetration of intermittent renewable sources often causes frequency deviations,voltage fluctuations,and poor reactive power coordination,posing serious challenges to grid stability.Conventional Interconnection FlowControllers(IFCs)primarily regulate active power flowand fail to effectively handle dynamic frequency variations or reactive power sharing in multi-microgrid networks.To overcome these limitations,this study proposes an enhanced Interconnection Flow Controller(e-IFC)that integrates frequency response balancing and an Interconnection Reactive Power Flow Controller(IRFC)within a unified adaptive control structure.The proposed e-IFC is implemented and analyzed in DIgSILENT PowerFactory to evaluate its performance under various grid disturbances,including frequency drops,load changes,and reactive power fluctuations.Simulation results reveal that the e-IFC achieves 27.4% higher active power sharing accuracy,19.6% lower reactive power deviation,and 18.2% improved frequency stability compared to the conventional IFC.The adaptive controller ensures seamless transitions between grid-connected and islanded modes and maintains stable operation even under communication delays and data noise.Overall,the proposed e-IFCsignificantly enhances active-reactive power coordination and dynamic stability in renewable-integrated multi-microgrid systems.Future research will focus on coupling the e-IFC with tertiary-level optimization frameworks and conducting hardware-in-the-loop validation to enable its application in large-scale smart microgrid environments.
基金supported by Science and Technology Project of the headquarters of the State Grid Corporation of China(No.5500-202324492A-3-2-ZN).
文摘To enhance power flow regulation in scenarios involving large-scale renewable energy transmission via high-voltage direct current(HVDC)links and multi-infeed DC systems in load-center regions,this paper proposes a hybrid modular multilevel converter–capacitor-commutated line-commutated converter(MMC-CLCC)HVDC transmission system and its corresponding control strategy.First,the system topology is constructed,and a submodule configuration method for the MMC—combining full-bridge submodules(FBSMs)and half-bridge submodules(HBSMs)—is proposed to enable direct power flow reversal.Second,a hierarchical control strategy is introduced,includingMMCvoltage control,CLCC current control,and a coordinationmechanism,along with the derivation of the hybrid system’s power flow reversal characteristics.Third,leveraging the CLCC’s fast current regulation and theMMC’s negative voltage control capability,a coordinated power flow reversal control strategy is developed.Finally,an 800 kV MMC-CLCC hybrid HVDC system is modeled in PSCAD/EMTDC to validate the power flow reversal performance under a high proportion of full-bridge submodule configuration.Results demonstrate that the proposed control strategy enables rapid(1-s transition)and smooth switching of bidirectional power flow without modifying the structure of primary equipment:the transient fluctuation ofDC voltage from the rated value(UdcN)to themaximumreverse voltage(-kUdcN)is less than 5%;the DC current strictly follows the preset characteristic curve with a deviation of≤3%;the active power reverses continuously,and the system maintains stable operation throughout the reversal process.
基金supported by the State Grid Corporation of China Science and Technology Project,grant number 52270723000900K.
文摘The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units.
基金supported by the National Key Research&Development Program of China under Grant 2024YFB2408900.
文摘Grid-forming(GFM)control is a key technology for ensuring the safe and stable operation of renewable power systems dominated by converter-interfaced generation(CIG),including wind power,photovoltaic,and battery energy storage.In this paper,we challenge the traditional approach of emulating a synchronous generator by proposing a frequency-fixed GFM control strategy.The CIG endeavors to regulate itself as a constant voltage source without control dynamics due to its capability limitation,denoted as the frequency-fixed zone.With the proposed strategy,the system frequency is almost always fixed at its rated value,achieving system active power balance independent of frequency,and intentional power flow adjustments are implemented through direct phase angle control.This approach significantly reduces the frequency dynamics and safety issues associated with frequency variations.Furthermore,synchronization dynamics are significantly diminished,and synchronization stability is enhanced.The proposed strategy has the potential to realize a renewable power system with a fixed frequency and robust stability.
基金supported by Liaoning Provincial Department of Education 2023 Basic Research Projects for Universities and Colleges(Grant No.JYTQN2023131)Liaoning Provincial Science and Technology Program:Cooperative Control and Recognition of Unmanned Vessels for Fishing Vessel Operation Scenarios(Grant No.600024003)Liaoning Provincial Department of Education Scientific Research Funding Project(Grant No.LJKZ0726).
文摘This paper proposes a separated trajectory tracking controller for fishing ships at sea state level 6 to solve the trajectory tracking problem of a fishing ship in a 6-level sea state,and to adapt to different working environments and safety requirements.The nonlinear feedback method is used to improve the closed-loop gain shaping algorithm.By introducing the sine function,the problem of excessive control energy of the system can be effectively solved.Moreover,an integral separation design is used to solve the influence of the integral term in conventional PID controllers on the transient performance of the system.In this paper,a common 32.98 m large fiberglass reinforced plastic(FRP)trawler is adopted for simulation research at the winds scale of Beaufort No.7.The results show that the track error is smaller than 3.5 m.The method is safe,feasible,concise and effective and has popularization value in the direction of fishing ship trajectory tracking control.This method can be used to improve the level of informatization and intelligence of fishing ships.
基金supported by the Opening Foundation of China National Logging Corporation(CNLC20229C06)the China Petroleum Technical Service Corporation's science project'Development and application of 475 rotary steering system'(2024T-001001)。
文摘Rotary steering systems(RSSs)have been increasingly used to develop horizontal wells.A static push-the-bit RSS uses three hydraulic modules with varying degrees of expansion and contraction to achieve changes in the pushing force acting on the wellbore in different sizes and directions within a circular range,ultimately allowing the wellbore trajectory to be drilled in a predetermined direction.By analyzing its mathematical principles and the actual characteristics of the instrument,a vector force closed-loop control method,including steering and holding modes,was designed.The adjustment criteria for the three hydraulic modules are determined to achieve rapid adjustment of the vector force.The theoretical feasibility of the developed method was verified by comparing its results with the on-site application data of an imported rotary guidance system.
基金supported by the National Natural Science Foundation of China(Grant Nos.12372064 and 12172291)the Youth and Middle-Aged Science and Technology Development Program of Shanghai Institute of Technology(Grant No.ZQ2024-10)。
文摘Conventional open-loop deep brain stimulation(DBS)systems with fixed parameters fail to accommodate interindividual pathological differences in Parkinson's disease(PD)management while potentially inducing adverse effects and causing excessive energy consumption.In this paper,we present an adaptive closed-loop framework integrating a Yogi-optimized proportional–integral–derivative neural network(Yogi-PIDNN)controller.The Yogi-augmented gradient adaptation mechanism accelerates the convergence of general PIDNN controllers in high-dimensional nonlinear control systems while reducing control energy usage.In addition,a system identification method establishes input–output dynamics for pre-training stimulation waveforms,bypassing real-time parameter-tuning constraints and thereby enhancing closed-loop adaptability.Finally,a theoretical analysis based on Lyapunov stability criteria establishes a sufficient condition for closed-loop stability within the identified model.Computational validations demonstrate that our approach restores thalamic relay reliability while reducing energy consumption by(81.0±0.7)%across multi-frequency tests.This study advances adaptive neuromodulation by synergizing data-driven pre-training with stability-guaranteed real-time control,offering a novel framework for energy-efficient and personalized Parkinson's therapy.
文摘The integration of cognitive radio and energy has enhanced the utilization efficiency of the spectrum and promoted the application of green energy.To begin with,this paper presents the architecture of green energy-efficient communication and network models.It incorporates the distributed network model and the heterogeneous two-tier network model into the green cognitive radio power control and channel allocation model.The primary focus of this research lies in energy conservation at the physical layer.To mitigate the interference with primary users and address the peak constraint in secondary user power allocation,the article analyzes the system model of the cognitive radio network and subsequently elaborates on the dynamic throughput maximization allocation algorithm.Eventually,through experimental analysis and verification,the distinctiveness and comprehensiveness of the optimal power control for this subject are illustrated.
基金supported by the National Natural Science Foundation of China(62403296,62303292,62173218).
文摘Dear Editor,This letter investigates the grid-forming control for power converters.Recently,grid-forming control based on matching of synchronous machines was suggested by using continuous measurements.In the present letter,we suggest a digital implementation using artificial delays where the controller employs the discrete-time measurements only.
基金supported by the key technology project of China Southern Power Grid Corporation(GZKJXM20220041)partly by theNational Key Research and Development Plan(2022YFE0205300).
文摘Aiming at the challenge of complex load balancing coordination for a three-phase four-leg(3P4L)based multi-ended low voltage flexible DC distribution system(M-LVDC)considering unbalanced power compensation,this paper proposes a phase-split power decoupling unbalanced compensation strategy based load balancing strategy for 3P4L based M-LVDC.Firstly,the topology and operation principle of the 3P4L-based M-LVDC system is introduced,and quasi-proportional resonant(QPR)based phase-split power current control for the 3P4L converter is proposed.Secondly,a load-balancing control strategy considering unbalanced compensation for 3P4L-based MLVDC is presented,in which the control diagrams for each 3P4L-based converter are detailed.The core idea of the proposed strategy is to comprehensively consider the imbalance compensation and load rate balancing between the two areas to calculate the split-phase power and current reference values of each 3P4L converter and achieve the static error-free tracking of the reference values through the QPR current inner-loop control.These reference values are then tracked with zero steady-state error using QPR current inner-loop control.Finally,the effectiveness of the proposed control strategy is verified through a 3P4L M-LVDC case study conducted on the PSCAD/EMTDC software.Theresults indicate that the proposed method not only can reduce the three-phase imbalance degrees from>20% to<0.5%,but also achieve excellent balanced load rates,with the load-rate difference smaller than 1.5%.
基金supported in part by the Department of Navy award N00014-24-1-2287 and N00014-23-1-2124。
文摘Modern shipboard microgrids(SMGs)incorporating distributed energy resources(DERs)enhance energy resilience and reduce carbon emissions.However,the hierarchical control schemes of DERs bring challenges to the traditional power flow methods.This paper devises a generalized three-phase power flow approach for SMGs that integrate hierarchically controlled DERs.The main contributions include:(1)a droop-controlled three-phase Newton power flow algorithm that automatically incorporates the droop characteristics of DERs;(2)a secondary-controlled three-phase power flow method for power sharing and voltage regulation;and(3)modified Jacobian matrices to incorporate various hierarchical control modes.Numerical results demonstrate the effectiveness of the devised approach in both balanced and unbalanced three-phase hierarchically controlled SMG systems with arbitrary config-urations.
文摘This study presents the use of an innovative population-based algorithm called the Sine Cosine Algorithm and its metaheuristic form,Quasi Oppositional Sine Cosine Algorithm,to automatic generation control of a multiple-source-based interconnected power system that consists of thermal,gas,and hydro power plants.The Proportional-Integral-Derivative controller,which is utilized for automated generation control in an interconnected hybrid power systemwith aDClink connecting two regions,has been tuned using the proposed optimization technique.An Electric Vehicle is taken into consideration only as an electrical load.The Quasi Oppositional Sine Cosinemethod’s performance and efficacy have been compared to the Sine Cosine Algorithm and optimal output feedback controller tuning performance.Applying the QOSCA optimization technique,which has only been shown in this study in the context of an LFC research thus far,makes this paper unique.The main objective has been used to assess and compare the dynamic performances of the recommended controller along with QOSCA optimisation technic.The resilience of the controller is examined using two different system parameters:B(frequency bias parameter)and R(governor speed regulation).The sensitivity analysis results demonstrate the high reliability of the QOSCA algorithm-based controller.Once optimal controller gains are established for nominal conditions,step load perturbations up to±10%&±25%in the nominal values of the systemparameters and operational load condition do not require adjustment of the controller.Ultimately,a scenario is examined whereby EVs are used for area 1,and a single PID controller is used rather than three.
基金supported by the National Natural Science Foundation of China,Regional Science Foundation Project,52367009,Study on Bow Net Dynamics Modeling and Coupling Smoothness of High speed AC Rigid Network in the Long Tunnel Section of Sichuan Tibet Railway.
文摘The cascaded H-bridge(CHB)multilevel inverter has become one of the most widely used PV inverter topologies due to its high voltage processing capability and high quality output power.Grid-connected PV system due to external conditions such as PV panel shading,PV component damage,can lead to PV output power imbalance,triggering the system over-modulation phenomenon,which in turn leads to grid-connected current waveform distortion.To this end,an improved power balance control strategy is proposed in this paper.Firstly,according to the different modulation ratios of each H-bridge module,a suitable harmonic injection method is used to keep the peak value of the modulating waveform always at 1;then an inverse triangular trapezoidal waveform is injected to optimize the modulating waveform,which further improves the output voltage waveform,reduces the THD value of the grid-connected currents,and maintains the stability of power inside the CHB system.Purpose.Simulation verifies the effectiveness and feasibility of this power balance control strategy.
基金supported by the National Natural Science Foundation of China(No.62063016)the Science and Technology Plan of Gansu Province(No.25JRRA088).
文摘Conventional droop control in multi-parallel grid-forming inverters exhibits poor reactive power sharing accuracy due to line impedance mismatches.In this study,we proposed a coordination control strategy integrating adaptive virtual impedance with dynamic Q-V droop regulation to overcome this issue.We established a coupling model between the line impedance and power allocation to determine the quantitative relationship between reactive power deviation and impedance difference and to analyze the mechanism of reactive power deviation formation.Based on this,we proposed a transformer neural network-based online identification method for adaptive virtual impedance and dynamic droop coefficients.The self-attention mechanism dynamically characterizes the spatial distribution features of the impedance parameters considering the real-time voltage/reactive power time-series data as inputs to realize the dynamic impedance compensation without communication interaction.The contradiction constraint between the voltage drop and distribution accuracy caused by the introduction of conventional virtual impedance is improved by dynamic droop coefficient reconstruction.Lastly,we established a hardware-in-the-loop simulation platform to experimentally validate the operational efficacy and dynamic performance of the proposed control strategy under various grid scenarios.
基金supported by the 2022 Sanya Science and Technology Innovation Project,China(No.2022KJCX03)the Sanya Science and Education Innovation Park,Wuhan University of Technology,China(Grant No.2022KF0028)the Hainan Provincial Joint Project of Sanya Yazhou Bay Science and Technology City,China(Grant No.2021JJLH0036).
文摘This study investigates the Maximum Power Point Tracking(MPPT)control method of offshore windphotovoltaic hybrid power generation system with offshore crane-assisted.A new algorithm of Global Fast Integral Sliding Mode Control(GFISMC)is proposed based on the tip speed ratio method and sliding mode control.The algorithm uses fast integral sliding mode surface and fuzzy fast switching control items to ensure that the offshore wind power generation system can track the maximum power point quickly and with low jitter.An offshore wind power generation system model is presented to verify the algorithm effect.An offshore off-grid wind-solar hybrid power generation systemis built in MATLAB/Simulink.Compared with other MPPT algorithms,this study has specific quantitative improvements in terms of convergence speed,tracking accuracy or computational efficiency.Finally,the improved algorithm is further analyzed and carried out by using Yuankuan Energy’s ModelingTech semi-physical simulation platform.The results verify the feasibility and effectiveness of the improved algorithm in the offshore wind-solar hybrid power generation system.
文摘AIM:To observe the effect of the plus power ring zone(PPRZ)area and distribution on myopia progression.METHODS:This retrospective study enrolled 137 pre-teens aged 8-12 at Taiyuan Aier Eye Hospital between 2019 and 2021.They were fitted with Ortho-K lenses for the first time due to refractive error,with a one-year follow-up period.To indicate the peripheral plus ring zone overlapping with the pupil zone(PPROPZ)accompanying PPRZ,participants were divided based on the PPROPZ to PPRZ ratio.The experimental group had 103 eyes with a PPROPZ to PPRZ ratio of≥0.2,and the control group had 103 eyes with a ratio of<0.2.Participants had a spherical diopter in the range of-6.00 D to-0.75 D,against-the-rule astigmatism less than 1.00 D,with-the-rule astigmatism less than 1.50 D,and corneal curvatures of 39.00 D to 46.00 D.They had a stable best corrected visual acuity of 0.10 LogMAR(20/25)or better when wearing orthokeratology(Ortho-K)lenses.PPRZ and PPROPZ were measured using ImageJ;corneal topography assessed corneal-related parameters,and an optical biometer measured the axial length of the eyes pre and post-one years of lens wear.RESULTS:Changes in axial length elongation were found to decrease when either the PPRZ(P<0.01)or PPROPZ(P<0.001)was increased significantly.The axial length growth was faster in the control group(0.37±0.2 mm)than in the experimental group(0.21±0.11 mm).Furthermore,we found that a larger horizontal visible iris diameter(HVID)corresponded to slower axial growth of the eye.In contrast,axial length growth showed no correlation with surface regularity index(SRI),surface asymmetry index(SAI),flat keratometry value(K_(f)),steep keratometry value(K_(s)).CONCLUSION:For orthokeratology,wearers with larger PPROPZ to PPRZ ratio usually experiences a reduction in axial length growth.The PPRZ and PPROPZ are negatively correlated with the axial length.Our findings provide a recommendation and methods for studying the myopia control mechanism through Ortho-K lenses.
基金supported by Natural Science Foundation of Shanghai,under the Shanghai Action Plan for Science,Technology and Innovation(22ZR1464800).
文摘Driven by the global energy transition and carbon neutrality targets,alkaline water electrolysis has emerged as a key technology for coupling variable renewable generation with clean hydrogen production,offering considerable potential for absorbing surplus power and enhancing grid flexibility.However,conventional control architectures typically treat the power converter and electrolyzer as independent units,neglecting their dynamic interactions and thereby limiting overall system performance under practical operating conditions.This review critically examines existing control approaches,ranging from classical proportional-integral schemes to model predictive control,fuzzy-logic algorithms,and data-driven methods,evaluating their effectiveness in managing dynamic response,multivariable coupling,and operational constraints as well as their inherent limitations.Attention is then focused on the performance requirements of the hydrogen-production converter,including current ripple suppression,rapid transient response,adaptive thermal regulation,and stable power delivery.An integrated co‑control framework is proposed,aligning converter output with electrolyzer demand across steady-state operation,variable renewable input,and emergency shutdown scenarios to achieve higher efficiency,extended equipment lifetime,and enhanced operational safety.Finally,prospects for advancing unified control methodologies are outlined,with emphasis on constraint-aware predictive control,machine-learning-enhanced modeling,and real‑time co‑optimization for future alkaline electrolyzer systems.
基金supported by the Natural Science Foundation of Jiangsu Province(BK20231445)Aeronautical Science Foundation of China(20230028052001).
文摘The proton exchange membrane fuel cell(PEMFC)and the hydrogen hybrid power system are studied by the fuzzy-PID(FPID)controlmethod and the fuzzy-PID controlmethod by Artificial Bee Colony algorithm(ABCFPID),respectively.The results reveal that compared with the FPID control method,the temperature overshoot of the PEMFC stack under the ABC-FPID control method is decreased by 0.6%.Moreover,the circulating water flow rate within the full operating envelope(about 3 min)is reduced by 19.46 L,which means the ABC-FPID control method is more effective in regulating the stack temperature.Then,the ABC-FPID control method is proposed to study the hydrogen hybrid power system,and the system output power matching,operating characteristic curve of the fuel cell,state of charge(SOC)of the lithium battery,system efficiency and hydrogen demand are obtained.The results indicate that the maximum system efficiency reaches 46.3%,the average system efficiency is 33.8%,and the average hydrogen demand is 0.192 kg/s.Overall,the ABC-FPID control method can efficiently ensure the stability of the fuel cell’s output power,and actively prompt the lithium battery to fulfill the function of“peak shaving and valley filling”under variable load power conditions.