With the development of more/all electrical aircraft technology, an electro-mechanical actuator(EMA) is more and more used in an aircraft actuation system. The motor system, as the crucial part of an EMA, usually ad...With the development of more/all electrical aircraft technology, an electro-mechanical actuator(EMA) is more and more used in an aircraft actuation system. The motor system, as the crucial part of an EMA, usually adopts the redundancy technology or fault tolerance technology to improve the reliability. To compare the performances of these two motor systems, a 10-pole/12-slot six-phase permanent magnet synchronous motor(PMSM) is designed with the concentrated single-layer winding, which is able to operate at dual-redundant and fault tolerant modes.Furthermore, the position servo performances of the six-phase PMSM at dual-redundant and fault tolerant modes are analyzed, including the normal and fault conditions. In addition, a variable structure proportional-integral-derivative(PID) control strategy is proposed to solve the performance degradation problem caused by phase current saturation. Simulation and experimental results show that the fault tolerant PMSM has a better position servo performance than the dual-redundant PMSM, and the variable structure PID control strategy is able to improve the performance due to phase current saturation.展开更多
Given large-scale modern power systems with pow er electronic converters,the numerical simulation with subsyn chronous oscillation(SSO)faces great challenges in engineering practice due to sharply enlarged modeling sc...Given large-scale modern power systems with pow er electronic converters,the numerical simulation with subsyn chronous oscillation(SSO)faces great challenges in engineering practice due to sharply enlarged modeling scale and high com putational burden.To reduce the modeling scale,network parti tion and equivalent becomes a vital technique in numerical sim ulations.Although several methods have been developed for net work equivalent,a generally accepted rule for network parti tion is still required.This paper proposes that the system can be partitioned into three parts,i.e.,the internal,the middle,and the external subsystems,in which the internal subsystem consists of all power electronic components,the middle subsys tem includes those selected AC dynamic components with de tailed models,and the remaining components and buses consti tute the external subsystem.The external subsystem is further represented by an equivalent RLC network determined by the frequency dependent network equivalent(FDNE)method.In the proposed method,the observability index and the electrical distance index are used to identify the interface between the middle and the external subsystems.Case studies based on a modified Hydro-Quebec system are used to verify the effective ness of the proposed method.展开更多
We give an overview of the main data of a publication-citation matrix. We show how impact factors are defined, and, in particular, point out the difference between the synchronous and the diachronous impact factor. Th...We give an overview of the main data of a publication-citation matrix. We show how impact factors are defined, and, in particular, point out the difference between the synchronous and the diachronous impact factor. The advantages and disadvantages of using both as tools in research evaluation are discussed.展开更多
基金supported by Aeronautical Science Foundation of China (No. 2016ZC51025)the Open Research Fund of Key Laboratory of Space Utilization, Chinese Academy of Science (No. 20161201)
文摘With the development of more/all electrical aircraft technology, an electro-mechanical actuator(EMA) is more and more used in an aircraft actuation system. The motor system, as the crucial part of an EMA, usually adopts the redundancy technology or fault tolerance technology to improve the reliability. To compare the performances of these two motor systems, a 10-pole/12-slot six-phase permanent magnet synchronous motor(PMSM) is designed with the concentrated single-layer winding, which is able to operate at dual-redundant and fault tolerant modes.Furthermore, the position servo performances of the six-phase PMSM at dual-redundant and fault tolerant modes are analyzed, including the normal and fault conditions. In addition, a variable structure proportional-integral-derivative(PID) control strategy is proposed to solve the performance degradation problem caused by phase current saturation. Simulation and experimental results show that the fault tolerant PMSM has a better position servo performance than the dual-redundant PMSM, and the variable structure PID control strategy is able to improve the performance due to phase current saturation.
基金supported by the Science and Technology Project of State Grid Zhejiang Electric Power Co.,Ltd.(No.5211JY21N001)the National Natural Science Foundation of China(No.51837004).
文摘Given large-scale modern power systems with pow er electronic converters,the numerical simulation with subsyn chronous oscillation(SSO)faces great challenges in engineering practice due to sharply enlarged modeling scale and high com putational burden.To reduce the modeling scale,network parti tion and equivalent becomes a vital technique in numerical sim ulations.Although several methods have been developed for net work equivalent,a generally accepted rule for network parti tion is still required.This paper proposes that the system can be partitioned into three parts,i.e.,the internal,the middle,and the external subsystems,in which the internal subsystem consists of all power electronic components,the middle subsys tem includes those selected AC dynamic components with de tailed models,and the remaining components and buses consti tute the external subsystem.The external subsystem is further represented by an equivalent RLC network determined by the frequency dependent network equivalent(FDNE)method.In the proposed method,the observability index and the electrical distance index are used to identify the interface between the middle and the external subsystems.Case studies based on a modified Hydro-Quebec system are used to verify the effective ness of the proposed method.
文摘We give an overview of the main data of a publication-citation matrix. We show how impact factors are defined, and, in particular, point out the difference between the synchronous and the diachronous impact factor. The advantages and disadvantages of using both as tools in research evaluation are discussed.