A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibit...A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C_(18) column using a 4-min gradient elution consisting of mobile phase A(0.1% formic acid in water) and mobile phase B(0.1% formic acid in acetonitrile), at a flow rate of 0.4 m L/min. Ceritinib and the internal standard([^(13)C_6]ceritinib) were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation(LLOQ) was 1 n M of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 n M in plasma. The intra-and interday precision and accuracy were within the generally accepted criteria for bioanalytical method( o15%).The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.展开更多
It is important to understand the mechanism and implications of different modifiers on analytical and preparative processes under chromatography with supercritical fluids (SFs) and under extraction with SFs. Supercrit...It is important to understand the mechanism and implications of different modifiers on analytical and preparative processes under chromatography with supercritical fluids (SFs) and under extraction with SFs. Supercritical fluid chromatography (SFC) and supercritical fluid extraction are generally carried out with neat supercritical carbon dioxide (SCCO2) or with SCCO2 containing modifiers (or cosolvents), especially for strongly polar compounds. For example, methanol is added as a cosolvent/modifier to SCCO2 for the extraction/separation of polar compounds. This paper discusses the influence of the modifier on the colligative properties of the principal mobile phase, which may define the situation in the total mobile phase in a chromatography column or in parts of a column under SFC. No colligative behavior of solutions reflects individual properties of the solutes. Their cross-interactions with solvents are discussed.展开更多
This study presents a fast, accurate and sensitive technique using gas chromatography-mass spectrometry (GC-MS) for the identification and quantification of N-acyl homoserine lactones (AHLs) in the extracts of bacteri...This study presents a fast, accurate and sensitive technique using gas chromatography-mass spectrometry (GC-MS) for the identification and quantification of N-acyl homoserine lactones (AHLs) in the extracts of bacterial strain of Pseudomonas aeruginosa and sputum sample of a cystic fibrosis patient. This method involves direct separation and determination of AHLs by using GC-MS as simultaneous separation and characterization of AHLs were possible without any prior derivatiza-tion. Electron ionization resulted in a common fragmentation pattern with the most common fragment ion at m/z 143 and other minor peaks at 73, 57 and 43. The limit of detection for N-butanoyl, N-hexanoyl, N-octanoyl, N-decanoyl, N-dodecanoyl and N-tetradecanoyl homoserine lactones was 2.14, 3.59, 2.71, 2.10, 2.45 and 2.34 μg/L, respectively. The presence of AHLs in the culture of P. aeruginosa strain and spu-tum of a cystic fibrosis patient was achieved in selected ion monitoring (SIM) mode by using the prominent fragment at m/z 143.展开更多
Developing a chiral material as versatile and universal chiral stationary phase(CSP) for chiral separation in diverse chromatographic techniques simultaneously is of great significance.In this study,we demonstrated fo...Developing a chiral material as versatile and universal chiral stationary phase(CSP) for chiral separation in diverse chromatographic techniques simultaneously is of great significance.In this study,we demonstrated for the first time that a chiral metal-organic cage(MOC),[Zn_(6)M_(4)],as a universal chiral recognition material for both multi-mode high-performance liquid chromatography(HPLC) and capillary gas chromatography(GC) enantioseparation.Two novel HPLC CSPs with different bonding arms(CSP-A with a cationic imidazolium bonding arm and CSP-B with an alkyl chain bonding arm) were prepared by clicking of functionalized chiral MOC [Zn_(6)M_(4)] onto thiolated silica via thiol-ene click chemistry.Meanwhile,a capillary GC column statically coated with the chiral MOC [Zn_(6)M_(4)] was also fabricated.The results showed that the chiral MOC exhibits excellent enantioselectivity not only in normal phase HPLC(NP-HPLC) and reversed phase(RP-HPLC) but also in GC,and various racemates were well separated,including alcohols,diols,esters,ketones,ethers,amines,and epoxides.Importantly,CSP-A and CSP-B are complementary to commercially available Chiralcel OD-H and Chiralpak AD-H columns in enantioseparation,which can separate some racemates that could not be or could not well be separated by the two widely used commercial columns,suggesting the great potential of the two prepared CSPs in enantioseparation.This work reveals that the chiral MOC is potential versatile chiral recognition materials for both HPLC and GC,and also paves the way to expand the potential applications of MOCs.展开更多
A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). ...A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). Gel permeation chromatography(GPC) was used to evaluate the molecular weight of synthesized CAR-CBA. Polyethyleneimine(PEI) with molecular weight of 25 kDa was adopted as a reference, and polyethylene glycols(PEG) with different molecular weights were used to establish a standard curve for determining the molecular weight of CAR-CBA. The effects of two critical factors, namely columns and eluents,on the molecular weight measurement of CAR-CBA were investigated to optimize the GPC quantitative method. The results showed that Ultrahydrogel columns(120, 250) and HAc–NaAc(0.5 M, pH 4.5) buffer solution were the optimal column and GPC eluent, respectively.The molecular weight of the synthesized CAR-CBA was analyzed by the optimized GPC method and determined to be 24.66 kDa.展开更多
Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively...Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.展开更多
This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile sampl...This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.展开更多
Cation-exchange high-performance liquid chromatography(CE-HPLC) is a widely used laboratory test to detect variant hemoglobins as well as quantify hemoglobins F and A2 for the diagnosis of thalassemia syndromes. It...Cation-exchange high-performance liquid chromatography(CE-HPLC) is a widely used laboratory test to detect variant hemoglobins as well as quantify hemoglobins F and A2 for the diagnosis of thalassemia syndromes. It's versatility, speed, reproducibility and convenience have made CE-HPLC the method of choice to initially screen for hemoglobin disorders. Despite its popularity, several methodological aspects of the technology remain obscure to pathologists and this may have consequences in specific situations. This paper discusses the basic principles of the technique, the initial quality control steps and the interpretation of various controls and variables that are available on the instrument output. Subsequent sections are devoted to methodological considerations that arise during reporting of cases. For instance, common problems of misidentified peaks, totals crossing 100%, causes of total area being above or below acceptable limits and the importance of pre-integration region peaks are dealt with. Ultimately, CE-HPLC remains an investigation, the reporting of which combines in-depth knowledge of the biological basics with more than a working knowledge of the technological aspects of the technique.展开更多
In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Pr...In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.展开更多
A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithe...A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.展开更多
Metal organic framework(MOF) assembled with coordination bonds has the disadvantage of poor stability that limits its application in the field of stationary phase,while covalent organic framework(COF)assembled through...Metal organic framework(MOF) assembled with coordination bonds has the disadvantage of poor stability that limits its application in the field of stationary phase,while covalent organic framework(COF)assembled through covalent bonds exhibits excellent structural stability.It has been shown that the stationary phases prepared by combining MOF and COF can make up for the poor stability of MOF@SiO_(2),and the MOF/COF composites have superior chromatographic separation performance.However,the traditional methods for preparing COF/MOF based stationary phases are generally solvent thermal synthesis.In this study,a green and low-cost synthesis method was proposed for the preparation of MOF/COF@SiO_(2) stationary phase.Firstly,COF@SiO_(2) was prepared in a choline chloride/ethylene glycol based deep eutectic solvent(DES).Secondly,another acid-base tunable DES prepared by mixing p-toluenesulfonic acid(PTSA)and 2-methylimidazole in different proportions was introduced as the reaction solvent and reactant for rapid synthesis of MOF/COF@SiO_(2).Compared with the toxic transition metal-based MOFs selected in most previous studies,a lightweight and non-toxic S-zone metal(calcium) based MOF was employed in this study.PTSA and calcium will form the calcium/oxygen-containing organic acid framework in acidic DES,which assembles with terephthalic acid dissolved in basic DES to form MOF.The strong hydrogen bonding effect of DES can facilitate rapid assembly of Ca-MOF.The obtained Ca-MOF/COF@SiO_(2) can be used for multi-mode chromatography to efficiently separate multiple isomeric/hydrophilic/hydrophobic analytes.The synthesis method of Ca-MOF/COF@SiO_(2) is green and mild,especially the use of acid-base tunable DES promotes the rapid synthesis of non-toxic Ca-MOF/COF@silica composites,which offers an innovative approach of greenly synthesizing novel MOF/COF stationary phases and extends their applications in the field of chromatography.展开更多
Arsenic speciation in freshwater fish is crucial for providing meaningful consumption guidelines that allow the public to make informed decisions regarding its consumption.While marine fish have attractedmuch research...Arsenic speciation in freshwater fish is crucial for providing meaningful consumption guidelines that allow the public to make informed decisions regarding its consumption.While marine fish have attractedmuch research interest due to their higher arsenic content,research on freshwater fish is limited due to the challenges in quantifying and identifying arsenic species present at trace levels.We describe here a sensitivemethod and its application to the quantification of arsenic species in freshwater fish.Arsenic species from fish tissues were extracted using a methanol/water mixture(1:1 vol.ratio)and ultrasound sonication.Anion-exchange high-performance liquid chromatography(HPLC)enabled separation of arsenobetaine(AsB),inorganic arsenite(iAs^(Ⅲ)),dimethylarsinic acid(DMA),monomethylarsonic acid(MMA),inorganic arsenate(iAs^(Ⅴ)),and three new arsenic species.Inductively coupled plasma mass spectrometry(ICPMS)provided highly sensitive and specific detection of arsenic.A limit of detection of 0.25μg/kg(wet weight fish tissue)was achieved for the five target arsenic species:AsB,iAs^(Ⅲ),DMA,MMA,and iAs^(Ⅴ).A series of experimentswere conducted to ensure the accuracy and validity of the analytical method.The method was successfully applied to the determination of arsenic species in lakewhitefish,northern pike,and walleye,with AsB,DMA,and iAs^(Ⅴ) being frequently detected.Three new arsenic species were detected,but their chromatographic retention times did not match with those of any available arsenic standards.Future research is necessary to elucidate the identity of these new arsenic species detected in freshwater fish.展开更多
Activity coefficients at infinite dilution, γ ∞ i, were calculated for 12 solutes, with organic solutes including linear alcohols (methanol, ethanol, propanol), linear alkanes (heptane, octane), benzene, toluene, cy...Activity coefficients at infinite dilution, γ ∞ i, were calculated for 12 solutes, with organic solutes including linear alcohols (methanol, ethanol, propanol), linear alkanes (heptane, octane), benzene, toluene, cyclohexane, 1, 2-dichloroethane, trichloroethylene, acetonitrile and carbon tetrachloride. The values of γ ∞ i were determined via either thermodynamic or artificial neural network modelling at different temperatures. A comparison between extracted results from these two methods confirmed that experimental and predicted results are roughly the same. The accuracy of predicted results proves this model is fully compatible with a wide range of solutes, and it can readily be used as an alternative to conventional gas-liquid chromatography for the measurements of activity coefficient at infinite dilution.展开更多
Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is...Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is called tube radical distribution chromatography (TRDC). Separation performance of the TRDC system using a fused-silica capillary tube was examined through the phase diagram for the ternary water-acetonitrile-ethyl acetate solvent mixture. The TRDC system required homogeneous carrier solutions with solvent component ratios around the boundary curve between homogeneous and heterogeneous solution in the phase diagram. The data obtained using the fused-silica capillary tube were compared with those obtained using a polytetrafluoroethylene capillary tube in our previous study.展开更多
The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas ...The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chroma- tography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractants from sample matrices which may have interfere to the qualitative and quantitative analysis, such as pigments, were removed using GPC purification. Simultaneous full scan and selective ion monitor (scan/SIM) mode for GC-MS was used for qualitative and quantitative analysis, which pro- vided retention time and characteristic fragments ratio for each pesticide so as to positively identify each analyte. Rela- tive standard deviations (RSDs) were within 7.7% (5.0 - 22.5 μg/kg, n = 3). The recoveries of pesticide standards at the spiked concentration of 5.0 - 22.5 μg/kg were between 87.1% and 110.9%. Limits of detection (LODs) for the analytes were 0.16 - 3.2 μg/kg, which could meet the demand of routine analysis and TCM quality control.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
[Objectives]To establish an HPLC method for the quantitative determination of multiple phenolic acid components in Tetracera asiatica medicinal material,providing a basis for establishing its quality standards.[Method...[Objectives]To establish an HPLC method for the quantitative determination of multiple phenolic acid components in Tetracera asiatica medicinal material,providing a basis for establishing its quality standards.[Methods]An Inertsil ODS-C 18 column(250 mm×4.6 mm,5μm)was used.The mobile phase consisted of acetonitrile-0.2% phosphoric acid solution(10:90).The flow rate was 1.0 mL/min.The detection wavelength was 274 nm.The column temperature was 25℃.The injection volume was 10μL.The content of three components,gallic acid,protocatechuic acid,and protocatechualdehyde,was determined in 13 batches of T.asiatica.[Results]Gallic acid showed good linearity within the range of 0.020-6.400μg/mL,protocatechuic acid within 0.201-6.432μg/mL,and protocatechualdehyde within 0.202-6.464μg/mL(r>0.9990).The average recovery rates ranged from 98.61%to 101.17%,with RSD s between 1.21%and 2.69%.[Conclusions]The quantitative determination method established in this study is simple and feasible,and can provide a basis for the quality evaluation of T.asiatica.展开更多
[Objectives] To develop a method for separation and purification of acetophenones from Cynanchum bengei Decne root bark by combination of silica gel and high-speed counter-current chromatography( HSCCC). [Methods]The ...[Objectives] To develop a method for separation and purification of acetophenones from Cynanchum bengei Decne root bark by combination of silica gel and high-speed counter-current chromatography( HSCCC). [Methods]The crude extract of Cynanchum bengei Decne root bark was separated by silica gel column chromatography,and parts A and B containing acetophenones were obtained. Then,parts A and B were separated by HSCCC with a two-phase solvent system composed of petroleum ether-ethyl acetate-methanol-water( 4∶ 6∶ 4. 5∶ 5. 5 and4∶ 6 ∶ 3 ∶ 7, V/V), respectively. [Results] From 260 mg of part A, four compounds with p-dihydroxybenzene 3. 9 mg(Ⅰ),4-hydroxyacetophenone 17. 1 mg( Ⅱ),2,5-di-hydroxyacetophenone 13. 3 mg(Ⅲ) and 2,4-dihydroxyaceto-phenone 21. 0 mg(Ⅳ) were obtained. And from 300 mg of part B,136 mg of Radix Cynanchi Bungei benzophenone(Ⅴ) was obtained. The purity of compounds determined by HPLC was 97. 0%,96. 6%,99. 2%,99. 7%,99. 5%,respectively. [Conclusions] The established method is simple and efficient. It can be used for separation of acetophenones from Cynanchum bengei Decne root bark and has better practical value,which could provide a reference basis for development and utilization of Cynanchum bengei Decne root bark.展开更多
[Objectives] To better control the quality of Nuhuang Fuzheng Oral Liquid and study the main component Cuscuta chinensis Lam.by Thin Layer Chromatography. [Methods] Through changing the treatment methods of the test s...[Objectives] To better control the quality of Nuhuang Fuzheng Oral Liquid and study the main component Cuscuta chinensis Lam.by Thin Layer Chromatography. [Methods] Through changing the treatment methods of the test sample solution,proportion of the developing solvent and sample application volume,taking the spot resolution,definition,and Rf value,optimal Thin Layer Chromatography conditions were screened for Cuscuta chinensis Lam. [Results] After the test sample solution passing the neutral alumina column,it was extracted two times using the ethyl acetate. Methanol was added to dissolve. Benzene-ethyl acetate-formic acid( 5∶5∶2.5) was used as developing solvent.And ammonia fumigation was carried out to develop color. In the thin layer chromatograph obtained through these conditions,Nuhuang Fuzheng Oral Liquid test sample solution showed the same stripe in the same position of the control drug chromatogram and there was no obvious tailing phenomenon and the spot was clear. [Conclusions] The thin layer chromatography identification conditions can be used as the method for quality control of Cuscuta chinensis Lam. in Nuhuang Fuzheng Oral Liquid.展开更多
A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established....A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.展开更多
基金supported by the United States Public Health Service Cancer Center Support Grant P30 CA022453Novartis for providing the study drug and isotope-labeled internal standard and providing financial support for the clinical study
文摘A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C_(18) column using a 4-min gradient elution consisting of mobile phase A(0.1% formic acid in water) and mobile phase B(0.1% formic acid in acetonitrile), at a flow rate of 0.4 m L/min. Ceritinib and the internal standard([^(13)C_6]ceritinib) were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation(LLOQ) was 1 n M of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 n M in plasma. The intra-and interday precision and accuracy were within the generally accepted criteria for bioanalytical method( o15%).The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.
文摘It is important to understand the mechanism and implications of different modifiers on analytical and preparative processes under chromatography with supercritical fluids (SFs) and under extraction with SFs. Supercritical fluid chromatography (SFC) and supercritical fluid extraction are generally carried out with neat supercritical carbon dioxide (SCCO2) or with SCCO2 containing modifiers (or cosolvents), especially for strongly polar compounds. For example, methanol is added as a cosolvent/modifier to SCCO2 for the extraction/separation of polar compounds. This paper discusses the influence of the modifier on the colligative properties of the principal mobile phase, which may define the situation in the total mobile phase in a chromatography column or in parts of a column under SFC. No colligative behavior of solutions reflects individual properties of the solutes. Their cross-interactions with solvents are discussed.
文摘This study presents a fast, accurate and sensitive technique using gas chromatography-mass spectrometry (GC-MS) for the identification and quantification of N-acyl homoserine lactones (AHLs) in the extracts of bacterial strain of Pseudomonas aeruginosa and sputum sample of a cystic fibrosis patient. This method involves direct separation and determination of AHLs by using GC-MS as simultaneous separation and characterization of AHLs were possible without any prior derivatiza-tion. Electron ionization resulted in a common fragmentation pattern with the most common fragment ion at m/z 143 and other minor peaks at 73, 57 and 43. The limit of detection for N-butanoyl, N-hexanoyl, N-octanoyl, N-decanoyl, N-dodecanoyl and N-tetradecanoyl homoserine lactones was 2.14, 3.59, 2.71, 2.10, 2.45 and 2.34 μg/L, respectively. The presence of AHLs in the culture of P. aeruginosa strain and spu-tum of a cystic fibrosis patient was achieved in selected ion monitoring (SIM) mode by using the prominent fragment at m/z 143.
基金supported by the National Natural Science Foundation of China (Nos.22064020,22364022,and 22174125)the Applied Basic Research Foundation of Yunnan Province (Nos.202101AT070101 and 202201AT070029)。
文摘Developing a chiral material as versatile and universal chiral stationary phase(CSP) for chiral separation in diverse chromatographic techniques simultaneously is of great significance.In this study,we demonstrated for the first time that a chiral metal-organic cage(MOC),[Zn_(6)M_(4)],as a universal chiral recognition material for both multi-mode high-performance liquid chromatography(HPLC) and capillary gas chromatography(GC) enantioseparation.Two novel HPLC CSPs with different bonding arms(CSP-A with a cationic imidazolium bonding arm and CSP-B with an alkyl chain bonding arm) were prepared by clicking of functionalized chiral MOC [Zn_(6)M_(4)] onto thiolated silica via thiol-ene click chemistry.Meanwhile,a capillary GC column statically coated with the chiral MOC [Zn_(6)M_(4)] was also fabricated.The results showed that the chiral MOC exhibits excellent enantioselectivity not only in normal phase HPLC(NP-HPLC) and reversed phase(RP-HPLC) but also in GC,and various racemates were well separated,including alcohols,diols,esters,ketones,ethers,amines,and epoxides.Importantly,CSP-A and CSP-B are complementary to commercially available Chiralcel OD-H and Chiralpak AD-H columns in enantioseparation,which can separate some racemates that could not be or could not well be separated by the two widely used commercial columns,suggesting the great potential of the two prepared CSPs in enantioseparation.This work reveals that the chiral MOC is potential versatile chiral recognition materials for both HPLC and GC,and also paves the way to expand the potential applications of MOCs.
基金the National Natural Science Foundation of China for financial support(No.81373335)
文摘A cationic gene delivery vector, guanidinylated disulfide-containing poly(amido amine)(CARCBA), was synthesized by Michael addition reaction between N,N′-cystaminebisacrylamide(CBA) and guanidine hydrochloride(CAR). Gel permeation chromatography(GPC) was used to evaluate the molecular weight of synthesized CAR-CBA. Polyethyleneimine(PEI) with molecular weight of 25 kDa was adopted as a reference, and polyethylene glycols(PEG) with different molecular weights were used to establish a standard curve for determining the molecular weight of CAR-CBA. The effects of two critical factors, namely columns and eluents,on the molecular weight measurement of CAR-CBA were investigated to optimize the GPC quantitative method. The results showed that Ultrahydrogel columns(120, 250) and HAc–NaAc(0.5 M, pH 4.5) buffer solution were the optimal column and GPC eluent, respectively.The molecular weight of the synthesized CAR-CBA was analyzed by the optimized GPC method and determined to be 24.66 kDa.
文摘Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.
文摘This paper reported a new analytical method for the simultaneous determination of seven benzotriazole ultraviolet absorbers and seven antibacterial agents in textiles. After ultrasonic extraction for the textile samples in methanol, the solutions were analyzed by ultra-high performance liquid chromotagraphy/orbitrap high resolution mass spectrometry (UPLC/Orbitrap HRMS). It showed that a good chromatographic separation for these target compounds was achieved by a Hypersil GOLD column (100 mm × 2.1 mm × 1.9 μm) with a gradient elution of methanol and 0.1% aqueous formic acid solution (containing 0.5 mmol/L ammonium acetate). Triclosan and 4-chloro-3,5-dimethyl phenol (PCMX) were detected by the orbitrap HRMS in an electrospray ionization (ESI) negative mode while the other twelve target compounds were detected by orbitrap HRMS in ESI positive mode. Full scan experiment was performed over the range from m/z 100 to m/z 500. These target compounds were routinely detected with mass accuracy below 2 × 10-6 (2 ppm) at the optimized conditions. The results showed that the limits of detection (LODs) were in the range from 0.1 to 0.3 μg/kg. The blank samples were spiked at three levels and their average recoveries varied from 80.5% to 96.3% while the relative standard deviation (RSD) changed from 3.2% to 9.9%. The present method was also applied for the determination of those ultraviolet absorbers and antibacterial agents in the commercial textiles.
文摘Cation-exchange high-performance liquid chromatography(CE-HPLC) is a widely used laboratory test to detect variant hemoglobins as well as quantify hemoglobins F and A2 for the diagnosis of thalassemia syndromes. It's versatility, speed, reproducibility and convenience have made CE-HPLC the method of choice to initially screen for hemoglobin disorders. Despite its popularity, several methodological aspects of the technology remain obscure to pathologists and this may have consequences in specific situations. This paper discusses the basic principles of the technique, the initial quality control steps and the interpretation of various controls and variables that are available on the instrument output. Subsequent sections are devoted to methodological considerations that arise during reporting of cases. For instance, common problems of misidentified peaks, totals crossing 100%, causes of total area being above or below acceptable limits and the importance of pre-integration region peaks are dealt with. Ultimately, CE-HPLC remains an investigation, the reporting of which combines in-depth knowledge of the biological basics with more than a working knowledge of the technological aspects of the technique.
文摘In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.
文摘A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.
基金supported by National Natural Science Foundation of China (Nos.21906124,32302202)Natural Science Foundation of Hubei Province (No.2017CFB220)Natural Science Foundation of Shandong Province (No.ZR2023MH278)。
文摘Metal organic framework(MOF) assembled with coordination bonds has the disadvantage of poor stability that limits its application in the field of stationary phase,while covalent organic framework(COF)assembled through covalent bonds exhibits excellent structural stability.It has been shown that the stationary phases prepared by combining MOF and COF can make up for the poor stability of MOF@SiO_(2),and the MOF/COF composites have superior chromatographic separation performance.However,the traditional methods for preparing COF/MOF based stationary phases are generally solvent thermal synthesis.In this study,a green and low-cost synthesis method was proposed for the preparation of MOF/COF@SiO_(2) stationary phase.Firstly,COF@SiO_(2) was prepared in a choline chloride/ethylene glycol based deep eutectic solvent(DES).Secondly,another acid-base tunable DES prepared by mixing p-toluenesulfonic acid(PTSA)and 2-methylimidazole in different proportions was introduced as the reaction solvent and reactant for rapid synthesis of MOF/COF@SiO_(2).Compared with the toxic transition metal-based MOFs selected in most previous studies,a lightweight and non-toxic S-zone metal(calcium) based MOF was employed in this study.PTSA and calcium will form the calcium/oxygen-containing organic acid framework in acidic DES,which assembles with terephthalic acid dissolved in basic DES to form MOF.The strong hydrogen bonding effect of DES can facilitate rapid assembly of Ca-MOF.The obtained Ca-MOF/COF@SiO_(2) can be used for multi-mode chromatography to efficiently separate multiple isomeric/hydrophilic/hydrophobic analytes.The synthesis method of Ca-MOF/COF@SiO_(2) is green and mild,especially the use of acid-base tunable DES promotes the rapid synthesis of non-toxic Ca-MOF/COF@silica composites,which offers an innovative approach of greenly synthesizing novel MOF/COF stationary phases and extends their applications in the field of chromatography.
基金supported by Alberta Health,Alberta Innovates,the Canada Research Chairs Program,the Canadian Institutes of Health Research,and the Natural Sciences and Engineering Research Council of Canada。
文摘Arsenic speciation in freshwater fish is crucial for providing meaningful consumption guidelines that allow the public to make informed decisions regarding its consumption.While marine fish have attractedmuch research interest due to their higher arsenic content,research on freshwater fish is limited due to the challenges in quantifying and identifying arsenic species present at trace levels.We describe here a sensitivemethod and its application to the quantification of arsenic species in freshwater fish.Arsenic species from fish tissues were extracted using a methanol/water mixture(1:1 vol.ratio)and ultrasound sonication.Anion-exchange high-performance liquid chromatography(HPLC)enabled separation of arsenobetaine(AsB),inorganic arsenite(iAs^(Ⅲ)),dimethylarsinic acid(DMA),monomethylarsonic acid(MMA),inorganic arsenate(iAs^(Ⅴ)),and three new arsenic species.Inductively coupled plasma mass spectrometry(ICPMS)provided highly sensitive and specific detection of arsenic.A limit of detection of 0.25μg/kg(wet weight fish tissue)was achieved for the five target arsenic species:AsB,iAs^(Ⅲ),DMA,MMA,and iAs^(Ⅴ).A series of experimentswere conducted to ensure the accuracy and validity of the analytical method.The method was successfully applied to the determination of arsenic species in lakewhitefish,northern pike,and walleye,with AsB,DMA,and iAs^(Ⅴ) being frequently detected.Three new arsenic species were detected,but their chromatographic retention times did not match with those of any available arsenic standards.Future research is necessary to elucidate the identity of these new arsenic species detected in freshwater fish.
文摘Activity coefficients at infinite dilution, γ ∞ i, were calculated for 12 solutes, with organic solutes including linear alcohols (methanol, ethanol, propanol), linear alkanes (heptane, octane), benzene, toluene, cyclohexane, 1, 2-dichloroethane, trichloroethylene, acetonitrile and carbon tetrachloride. The values of γ ∞ i were determined via either thermodynamic or artificial neural network modelling at different temperatures. A comparison between extracted results from these two methods confirmed that experimental and predicted results are roughly the same. The accuracy of predicted results proves this model is fully compatible with a wide range of solutes, and it can readily be used as an alternative to conventional gas-liquid chromatography for the measurements of activity coefficient at infinite dilution.
文摘Capillary chromatography using an untreated open tubular capillary tube and a ternary solvent mixture consisting of water-hydrophilic/hydrophobic organic solvent as a carrier solution has been developed. The system is called tube radical distribution chromatography (TRDC). Separation performance of the TRDC system using a fused-silica capillary tube was examined through the phase diagram for the ternary water-acetonitrile-ethyl acetate solvent mixture. The TRDC system required homogeneous carrier solutions with solvent component ratios around the boundary curve between homogeneous and heterogeneous solution in the phase diagram. The data obtained using the fused-silica capillary tube were compared with those obtained using a polytetrafluoroethylene capillary tube in our previous study.
文摘The measurement of 23 organochlorine, organophosphorus, and pyrethroid pesticides in typical traditional Chinese medicine (TCM), flos lonicerae, was made using gel permeation chromatography (GPC) purification and gas chroma- tography-mass spectrometry (GC-MS) detection. The pesticides were extracted with ultrasonic device and 5.0 mL mixture of ethyl acetate and cyclohexane (1:1, v/v). Coextractants from sample matrices which may have interfere to the qualitative and quantitative analysis, such as pigments, were removed using GPC purification. Simultaneous full scan and selective ion monitor (scan/SIM) mode for GC-MS was used for qualitative and quantitative analysis, which pro- vided retention time and characteristic fragments ratio for each pesticide so as to positively identify each analyte. Rela- tive standard deviations (RSDs) were within 7.7% (5.0 - 22.5 μg/kg, n = 3). The recoveries of pesticide standards at the spiked concentration of 5.0 - 22.5 μg/kg were between 87.1% and 110.9%. Limits of detection (LODs) for the analytes were 0.16 - 3.2 μg/kg, which could meet the demand of routine analysis and TCM quality control.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
基金Supported by Regional Science Foundation of China,National Natural Science Foundation(No.82160820)General Program of Guizhou Provincial Natural Science Foundation[QianKeHe Foundation-ZK(2023)General153].
文摘[Objectives]To establish an HPLC method for the quantitative determination of multiple phenolic acid components in Tetracera asiatica medicinal material,providing a basis for establishing its quality standards.[Methods]An Inertsil ODS-C 18 column(250 mm×4.6 mm,5μm)was used.The mobile phase consisted of acetonitrile-0.2% phosphoric acid solution(10:90).The flow rate was 1.0 mL/min.The detection wavelength was 274 nm.The column temperature was 25℃.The injection volume was 10μL.The content of three components,gallic acid,protocatechuic acid,and protocatechualdehyde,was determined in 13 batches of T.asiatica.[Results]Gallic acid showed good linearity within the range of 0.020-6.400μg/mL,protocatechuic acid within 0.201-6.432μg/mL,and protocatechualdehyde within 0.202-6.464μg/mL(r>0.9990).The average recovery rates ranged from 98.61%to 101.17%,with RSD s between 1.21%and 2.69%.[Conclusions]The quantitative determination method established in this study is simple and feasible,and can provide a basis for the quality evaluation of T.asiatica.
基金Supported by National Natural Science Foundation Item of 2014(81373941)Shandong Natural Science Foundation Item of 2012(ZR2012HM047)+1 种基金Science and Technology Development Plan Item of Shandong(2014G2X219003)Major Project of the State Administration of Traditional Chinese Medicine(201407002)
文摘[Objectives] To develop a method for separation and purification of acetophenones from Cynanchum bengei Decne root bark by combination of silica gel and high-speed counter-current chromatography( HSCCC). [Methods]The crude extract of Cynanchum bengei Decne root bark was separated by silica gel column chromatography,and parts A and B containing acetophenones were obtained. Then,parts A and B were separated by HSCCC with a two-phase solvent system composed of petroleum ether-ethyl acetate-methanol-water( 4∶ 6∶ 4. 5∶ 5. 5 and4∶ 6 ∶ 3 ∶ 7, V/V), respectively. [Results] From 260 mg of part A, four compounds with p-dihydroxybenzene 3. 9 mg(Ⅰ),4-hydroxyacetophenone 17. 1 mg( Ⅱ),2,5-di-hydroxyacetophenone 13. 3 mg(Ⅲ) and 2,4-dihydroxyaceto-phenone 21. 0 mg(Ⅳ) were obtained. And from 300 mg of part B,136 mg of Radix Cynanchi Bungei benzophenone(Ⅴ) was obtained. The purity of compounds determined by HPLC was 97. 0%,96. 6%,99. 2%,99. 7%,99. 5%,respectively. [Conclusions] The established method is simple and efficient. It can be used for separation of acetophenones from Cynanchum bengei Decne root bark and has better practical value,which could provide a reference basis for development and utilization of Cynanchum bengei Decne root bark.
基金Supported by Clinical Study and New Veterinary Drug Declaration of Lianmei Zhili Powder and Nuhuang Granule(17403)
文摘[Objectives] To better control the quality of Nuhuang Fuzheng Oral Liquid and study the main component Cuscuta chinensis Lam.by Thin Layer Chromatography. [Methods] Through changing the treatment methods of the test sample solution,proportion of the developing solvent and sample application volume,taking the spot resolution,definition,and Rf value,optimal Thin Layer Chromatography conditions were screened for Cuscuta chinensis Lam. [Results] After the test sample solution passing the neutral alumina column,it was extracted two times using the ethyl acetate. Methanol was added to dissolve. Benzene-ethyl acetate-formic acid( 5∶5∶2.5) was used as developing solvent.And ammonia fumigation was carried out to develop color. In the thin layer chromatograph obtained through these conditions,Nuhuang Fuzheng Oral Liquid test sample solution showed the same stripe in the same position of the control drug chromatogram and there was no obvious tailing phenomenon and the spot was clear. [Conclusions] The thin layer chromatography identification conditions can be used as the method for quality control of Cuscuta chinensis Lam. in Nuhuang Fuzheng Oral Liquid.
文摘A method of rapidly detecting three kinds of microcystins( MCs) in environmental water samples by using disk SPE- ultra high performance liquid chromatography- tandem mass spectrometry( UPLC- MS / MS) was established. Firstly,environmental water samples were extracted by disk SPE column( C_(18)),and three kinds of MCs were separated by Waters BEH C_(18) chromatographic column with acetonitrile- 0. 2% formic acid solution as the mobile phase. After the gradient elution separation,the external standard method was used for quantitative and qualitative analysis under MRM of UPLC- MS / MS. The results showed that the three kinds of MCs in the range of 0. 05- 10 μg / L showed good linear relation,and the correlation coefficients were higher than 0. 999 4,while the method detection limit was 0. 04 ng / L. Under 0. 1,1,and 5 μg / L standard addition for the same environmental sample,the average recovery was 82. 8%- 108. 8%,and the relative standard deviation of determination results was2. 1%- 10. 1%( n = 6). This method is rapid,sensitive and accurate,so it can be effectively applied in the monitoring of MCs in environmental water samples.