Cleaning of hollow-fibre polyvinyl chloride (PVC) membrane with different chemical reagents after ultrafiltration of algal-rich water was investigated. Among the tested cleaning reagents (NaOH, HCl, EDTA, and NaClO...Cleaning of hollow-fibre polyvinyl chloride (PVC) membrane with different chemical reagents after ultrafiltration of algal-rich water was investigated. Among the tested cleaning reagents (NaOH, HCl, EDTA, and NaClO), 100 mg/L NaClO exhibited the best performance (88.4% ± 1.1%) in removing the irreversible fouling resistance. This might be attributed to the fact that NaClO could eliminate almost all the major foulants such as carbohydrate-like and protein-like materials on the membrane surface, as confirmed by Fourier transform infrared spectroscopy analysis. However, negligible irreversible resistance (1.5% ± 1.0%) was obtained when the membrane was cleaning by 500 mg/L NaOH for 1.0 hr, although the NaOH solution could also desorb a portion of the major foulants from the fouled PVC membrane. Scanning electronic microscopy and atomic force microscopy analyses demonstrated that 500 mg/L NaOH could change the structure of the residual foulants on the membrane, making them more tightly attached to the membrane surface. This phenomenon might be responsible for the negligible membrane permeability restoration after NaOH cleaning. On the other hand, the microscopic analyses reflected that NaClO could effectively remove the foulants accumulated on the membrane surface.展开更多
A numerical model was established to predict and optimise the chemical cleaning process of Polyvinylidene Fluo- ride (PVDF) Ultrafiltration (UF) membranes with the results from the experiment that applied the Resp...A numerical model was established to predict and optimise the chemical cleaning process of Polyvinylidene Fluo- ride (PVDF) Ultrafiltration (UF) membranes with the results from the experiment that applied the Response Sur- face Method (RSM) and Central Composite Design (CCD). The factors considered in the experimental design were sodium hydroxide (NaOH) concentration, sodium bypochlorite concentration (NaCIO), citric acid concentration and cleaning duration, The interactions between the factors were investigated with the numerical model. Humic acid (20 mg· L-1) was used as the model foulant, and chemical enhanced backflush (CEB) was employed to sim- ulate the chemical cleaning process. The concentrations of sodium hydroxide, sodium hypochlorite, citric acid and cleaning duration tested during the experiments were in the range of 0.1%-0.3% 100-300 mg· L-1 1%-3% and 0.5-1.5 h, respectively. Among the variables, the sodium hypochlorite concentration and the cleaning dura- tion showed a positive relationship involving the increased efficiency of the chemical cleaning. The chemical cleaning efficiency was hardly improved with increasing concentrations of sodium hydroxide. However, the data was sharply decreased when at a low level of sodium hydroxide concentration. In total, 54 sets of cleaning schemes with 80% to 100K cleaning efficiency were observed with the R&M model after calibration.展开更多
Severe fouling to poly(vinylidene fluoride)(PVDF)membrane is usually caused as filtrating the papermaking wastewater in the ultrafiltration(UF)process.In the paper,fouling behavior and mechanism were investigated,and ...Severe fouling to poly(vinylidene fluoride)(PVDF)membrane is usually caused as filtrating the papermaking wastewater in the ultrafiltration(UF)process.In the paper,fouling behavior and mechanism were investigated,and the low-concentration polyvinyl alcohol(PVA)contained in the sedimentation tank wastewater was found as the main foulant.Consequently,the corresponding cleaning approach was proposed.The experiment and modeling results elaborated that the fouling mode developed from pore blockage to cake layer along with filtration time.Chemical cleaning conditions including the composition and concentration of reagents,cleaning duration and trans-membrane pressure were investigated for their effect on cleaning efficiency.Pure water flux was recovered by over 95% after cleaning the PVDF membrane using the optimal conditions 0.5 wt% NaClO(as oxidant)and 0.1 wt% sodiumdodecyl benzene sulfonate(SDBS,as surfactant)at 0.04MPa for 100 min.In the chemical cleaning method,hypochlorite(ClO−)could first chain-scissor PVA macromolecules to small molecules and SDBS could wrap the fragments in micelles,so that the foulants were removed from the pores and surface of membrane.After eight cycling tests,pure water flux recovery maintained above 95% and the reused membrane was found intact without defects.展开更多
Based on the research on corrosion-resistance of titanium in various media and a great deal of tests, a newchemical cleaning process for titanium-made equipment was developed and applied to titanium-made heat exchange...Based on the research on corrosion-resistance of titanium in various media and a great deal of tests, a newchemical cleaning process for titanium-made equipment was developed and applied to titanium-made heat exchangersof a homemade multi-stage flash distiller for sea-water desalination in Tianjin Dagang Power Plant. Scale in the tubeswas removed completely as inspected by the experts. Testing results of hydrogen content and metallographic structureof titanium tubes showed that the cleaning was successful without any damages to the equipment.[展开更多
Na Cl O has been widely used to restore membrane flux in practical membrane cleaning processes,which would induce the formation of toxic halogenated byproducts.In this study,we proposed a novel heatactivated peroxydis...Na Cl O has been widely used to restore membrane flux in practical membrane cleaning processes,which would induce the formation of toxic halogenated byproducts.In this study,we proposed a novel heatactivated peroxydisulfate(heat/PDS)process to clean the membrane fouling derived from humic acid(HA).The results show that the combination of heat and PDS can achieve almost 100%recovery of permeate flux after soaking the HA-fouled membrane in 1 mmol/L PDS solution at 50℃ for 2 h,which is attributed to the changes of HA structure and enhanced detachment of foulants from membranes.The properties of different treated membranes are characterized by scanning electron microscopy(SEM),atomic force microscope(AFM),attenuated total reflection Fourier transform infrared spectroscopy(ATRFTIR),and X-ray photoelectron spectroscopy(XPS),demonstrating that the reversible and irreversible foulants could be effectively removed by heat/PDS cleaning.The filtration process and fouling mechanism of the cleaned membrane were close to that of the virgin membrane,illustrating the good reusability of the cleaned membrane.Additionally,heat/PDS which can avoid the generation of halogenated byproducts shows comparable performance to Na Cl O on membrane cleaning and high performance for the removal of fouling caused by sodium alginate(SA),HA-bovine serum albumin(BSA)-SA mixture and algae,further suggesting that heat/PDS would be a potential alternative for membrane cleaning in practical application.展开更多
GaN samples 1-3 are cleaned by a 2:2:1 solution of sulfuric acid(98%) to hydrogen peroxide(30%) to de-ionized water;hydrochloric acid(37%);or a 4:1 solution of sulfuric acid(98%) to hydrogen peroxide(30%)...GaN samples 1-3 are cleaned by a 2:2:1 solution of sulfuric acid(98%) to hydrogen peroxide(30%) to de-ionized water;hydrochloric acid(37%);or a 4:1 solution of sulfuric acid(98%) to hydrogen peroxide(30%).The samples are activated by Cs/O after the same annealing process.X-ray photoelectron spectroscopy after the different ways of wet chemical cleaning shows:sample 1 has the largest proportion of Ga,N,and O among the three samples,while its C content is the lowest.After activation the quantum efficiency curves show sample 1 has the best photocathode performance.We think the wet chemical cleaning method is a process which will mainly remove C contamination.展开更多
Coal is fossil fuel abundant and widespread all over the world. It is a vital resource for energy security in our country, because the supply is stable. In this paper, the important role of coal played in the total pr...Coal is fossil fuel abundant and widespread all over the world. It is a vital resource for energy security in our country, because the supply is stable. In this paper, the important role of coal played in the total primary energy supply was described, and the status of modern coal chemical industry and clean coal technologies was analyzed. Based on the scientific research experiences of author, strategy and suggestion for Chinese development were proposed according to the regulation of scientific panning. In China, there are more social benefits and strategic meaning for developing the coal high-efficiency utilization technology. Considering of the general situation of our countries, these technologies with the features of can be industrialized, advanced, applicative, mature and feasible should be developed preferentially. The high-expend, low economic effectiveness and behindhand technologies should be abandoned. So, the development of coal clean technology in China should meet the natural resources, restrictive condition and elements of our countries industry situations. Based on these analysis, the most important technologies and fundamental researches should be prior developed in China.展开更多
First business: to clean a tea pot. Income: RMB 0.20 (less than 10 US cents at the time). Second business: to clean a boiler. Income: RMB 1, 200. Three months later, incomereached RMB 240, 000. Ten years later, the co...First business: to clean a tea pot. Income: RMB 0.20 (less than 10 US cents at the time). Second business: to clean a boiler. Income: RMB 1, 200. Three months later, incomereached RMB 240, 000. Ten years later, the company had 350 subsidiaries across China and four joint ventures abroad, with an annual output value of more than RMB 300 million. The data are simple but intriguing, recording the history of the Blue展开更多
Due to its extensive use in shale gas exploration and development,oil-based drilling fluids generate large amounts of oil-bearing drill cuttings during the drilling process.The large amount of oil-bearing drill cuttin...Due to its extensive use in shale gas exploration and development,oil-based drilling fluids generate large amounts of oil-bearing drill cuttings during the drilling process.The large amount of oil-bearing drill cuttings generated during the drilling process can lead to serious secondary contamination.In this study,a wetting agent FSC-6 with good hydrophobic and oleophobic properties was synthesized to construct an efficient oil removal system.For the first time,the mechanism of this system was analyzed by using the theory of adhesion function,interfacial tension and wettability.At the same time,a combined acoustic-chemical treatment process was applied to the wastewater and slag generated after the cleaning of the oil-bearing drill cuttings.The experimental results show that the application of this pollution-free technology can effectively solve the environmental pollution and resource recovery problems of oil-bearing drill cuttings.It meets the standard of drilling chips with oil content less than 2%in SY/T7422-2018“Oil-based drilling fluid drilling chips treatment system for oil and gas drilling equipment”.展开更多
Chemical cleaning has been reported as the best method to restore ceramic filters flow rate by removing fouling agents. Even though there are several chemicals that can be used as cleaning agents, sodium hydroxide (Na...Chemical cleaning has been reported as the best method to restore ceramic filters flow rate by removing fouling agents. Even though there are several chemicals that can be used as cleaning agents, sodium hydroxide (NaOH) has been widely used as a cleaning agent. Literature reports that main factors of this cleaning are sodium hydroxide concentration, treatment temperature and contact time. However, the most significant factors have not been determined nor the interactions between them. The aim of this study was to determine the most significant parameter and the interactions between sodium hydroxide concentration, treatment temperature and contact time. This was done using Box-Behnken experimental design. The results, based on ANOVA analyses, showed that temperature is the most significant factor and that interaction between sodium hydroxide concentration and treatment temperature is the most significant interaction.展开更多
基金supported by the Important Special Program of Science and Technology for the Control and Treatment of Water Pollution in China(No.2008ZX07422-005)the National Science and Technology Project of Eleventh Five Years(No.2006BAJ08B05-2)+2 种基金the National Creative Research Groups Foundation of China(No.50821002)the State Key Laboratory of Urban Water Resource and Environment(No.2008DX04)the National Postdoctoral Science Foundation of China(No.20100471062)
文摘Cleaning of hollow-fibre polyvinyl chloride (PVC) membrane with different chemical reagents after ultrafiltration of algal-rich water was investigated. Among the tested cleaning reagents (NaOH, HCl, EDTA, and NaClO), 100 mg/L NaClO exhibited the best performance (88.4% ± 1.1%) in removing the irreversible fouling resistance. This might be attributed to the fact that NaClO could eliminate almost all the major foulants such as carbohydrate-like and protein-like materials on the membrane surface, as confirmed by Fourier transform infrared spectroscopy analysis. However, negligible irreversible resistance (1.5% ± 1.0%) was obtained when the membrane was cleaning by 500 mg/L NaOH for 1.0 hr, although the NaOH solution could also desorb a portion of the major foulants from the fouled PVC membrane. Scanning electronic microscopy and atomic force microscopy analyses demonstrated that 500 mg/L NaOH could change the structure of the residual foulants on the membrane, making them more tightly attached to the membrane surface. This phenomenon might be responsible for the negligible membrane permeability restoration after NaOH cleaning. On the other hand, the microscopic analyses reflected that NaClO could effectively remove the foulants accumulated on the membrane surface.
基金Supported by State Key Laboratory of Urban Water Resource and Environment(2016DX01)the Fundamental Research Funds for the Central University(NSRIF.2014096)Science and Technology Planning Project of Chancheng District(2013A1044)
文摘A numerical model was established to predict and optimise the chemical cleaning process of Polyvinylidene Fluo- ride (PVDF) Ultrafiltration (UF) membranes with the results from the experiment that applied the Response Sur- face Method (RSM) and Central Composite Design (CCD). The factors considered in the experimental design were sodium hydroxide (NaOH) concentration, sodium bypochlorite concentration (NaCIO), citric acid concentration and cleaning duration, The interactions between the factors were investigated with the numerical model. Humic acid (20 mg· L-1) was used as the model foulant, and chemical enhanced backflush (CEB) was employed to sim- ulate the chemical cleaning process. The concentrations of sodium hydroxide, sodium hypochlorite, citric acid and cleaning duration tested during the experiments were in the range of 0.1%-0.3% 100-300 mg· L-1 1%-3% and 0.5-1.5 h, respectively. Among the variables, the sodium hypochlorite concentration and the cleaning dura- tion showed a positive relationship involving the increased efficiency of the chemical cleaning. The chemical cleaning efficiency was hardly improved with increasing concentrations of sodium hydroxide. However, the data was sharply decreased when at a low level of sodium hydroxide concentration. In total, 54 sets of cleaning schemes with 80% to 100K cleaning efficiency were observed with the R&M model after calibration.
基金financially supported by the National Natural Science Foundation of China(21921006).
文摘Severe fouling to poly(vinylidene fluoride)(PVDF)membrane is usually caused as filtrating the papermaking wastewater in the ultrafiltration(UF)process.In the paper,fouling behavior and mechanism were investigated,and the low-concentration polyvinyl alcohol(PVA)contained in the sedimentation tank wastewater was found as the main foulant.Consequently,the corresponding cleaning approach was proposed.The experiment and modeling results elaborated that the fouling mode developed from pore blockage to cake layer along with filtration time.Chemical cleaning conditions including the composition and concentration of reagents,cleaning duration and trans-membrane pressure were investigated for their effect on cleaning efficiency.Pure water flux was recovered by over 95% after cleaning the PVDF membrane using the optimal conditions 0.5 wt% NaClO(as oxidant)and 0.1 wt% sodiumdodecyl benzene sulfonate(SDBS,as surfactant)at 0.04MPa for 100 min.In the chemical cleaning method,hypochlorite(ClO−)could first chain-scissor PVA macromolecules to small molecules and SDBS could wrap the fragments in micelles,so that the foulants were removed from the pores and surface of membrane.After eight cycling tests,pure water flux recovery maintained above 95% and the reused membrane was found intact without defects.
文摘Based on the research on corrosion-resistance of titanium in various media and a great deal of tests, a newchemical cleaning process for titanium-made equipment was developed and applied to titanium-made heat exchangersof a homemade multi-stage flash distiller for sea-water desalination in Tianjin Dagang Power Plant. Scale in the tubeswas removed completely as inspected by the experts. Testing results of hydrogen content and metallographic structureof titanium tubes showed that the cleaning was successful without any damages to the equipment.[
基金supported by the Natural Science Foundation of China(Nos.52070081,51578258 and 51878308)the National Key Research and Development Program of China(No.2022YFC3203500)。
文摘Na Cl O has been widely used to restore membrane flux in practical membrane cleaning processes,which would induce the formation of toxic halogenated byproducts.In this study,we proposed a novel heatactivated peroxydisulfate(heat/PDS)process to clean the membrane fouling derived from humic acid(HA).The results show that the combination of heat and PDS can achieve almost 100%recovery of permeate flux after soaking the HA-fouled membrane in 1 mmol/L PDS solution at 50℃ for 2 h,which is attributed to the changes of HA structure and enhanced detachment of foulants from membranes.The properties of different treated membranes are characterized by scanning electron microscopy(SEM),atomic force microscope(AFM),attenuated total reflection Fourier transform infrared spectroscopy(ATRFTIR),and X-ray photoelectron spectroscopy(XPS),demonstrating that the reversible and irreversible foulants could be effectively removed by heat/PDS cleaning.The filtration process and fouling mechanism of the cleaned membrane were close to that of the virgin membrane,illustrating the good reusability of the cleaned membrane.Additionally,heat/PDS which can avoid the generation of halogenated byproducts shows comparable performance to Na Cl O on membrane cleaning and high performance for the removal of fouling caused by sodium alginate(SA),HA-bovine serum albumin(BSA)-SA mixture and algae,further suggesting that heat/PDS would be a potential alternative for membrane cleaning in practical application.
基金Projects supported by the National Natural Science Foundation of China (Grant No. 60871012)the National Key Laboratory of Science and Technology Foundation on Low Light Level Night Vision (Grant No. J20110104)the Research and Innovation Plan for Graduate Students of Jiangsu Higher Education Institutions (Grant No. CXZZ11 0238)
文摘GaN samples 1-3 are cleaned by a 2:2:1 solution of sulfuric acid(98%) to hydrogen peroxide(30%) to de-ionized water;hydrochloric acid(37%);or a 4:1 solution of sulfuric acid(98%) to hydrogen peroxide(30%).The samples are activated by Cs/O after the same annealing process.X-ray photoelectron spectroscopy after the different ways of wet chemical cleaning shows:sample 1 has the largest proportion of Ga,N,and O among the three samples,while its C content is the lowest.After activation the quantum efficiency curves show sample 1 has the best photocathode performance.We think the wet chemical cleaning method is a process which will mainly remove C contamination.
文摘Coal is fossil fuel abundant and widespread all over the world. It is a vital resource for energy security in our country, because the supply is stable. In this paper, the important role of coal played in the total primary energy supply was described, and the status of modern coal chemical industry and clean coal technologies was analyzed. Based on the scientific research experiences of author, strategy and suggestion for Chinese development were proposed according to the regulation of scientific panning. In China, there are more social benefits and strategic meaning for developing the coal high-efficiency utilization technology. Considering of the general situation of our countries, these technologies with the features of can be industrialized, advanced, applicative, mature and feasible should be developed preferentially. The high-expend, low economic effectiveness and behindhand technologies should be abandoned. So, the development of coal clean technology in China should meet the natural resources, restrictive condition and elements of our countries industry situations. Based on these analysis, the most important technologies and fundamental researches should be prior developed in China.
文摘First business: to clean a tea pot. Income: RMB 0.20 (less than 10 US cents at the time). Second business: to clean a boiler. Income: RMB 1, 200. Three months later, incomereached RMB 240, 000. Ten years later, the company had 350 subsidiaries across China and four joint ventures abroad, with an annual output value of more than RMB 300 million. The data are simple but intriguing, recording the history of the Blue
文摘Due to its extensive use in shale gas exploration and development,oil-based drilling fluids generate large amounts of oil-bearing drill cuttings during the drilling process.The large amount of oil-bearing drill cuttings generated during the drilling process can lead to serious secondary contamination.In this study,a wetting agent FSC-6 with good hydrophobic and oleophobic properties was synthesized to construct an efficient oil removal system.For the first time,the mechanism of this system was analyzed by using the theory of adhesion function,interfacial tension and wettability.At the same time,a combined acoustic-chemical treatment process was applied to the wastewater and slag generated after the cleaning of the oil-bearing drill cuttings.The experimental results show that the application of this pollution-free technology can effectively solve the environmental pollution and resource recovery problems of oil-bearing drill cuttings.It meets the standard of drilling chips with oil content less than 2%in SY/T7422-2018“Oil-based drilling fluid drilling chips treatment system for oil and gas drilling equipment”.
文摘Chemical cleaning has been reported as the best method to restore ceramic filters flow rate by removing fouling agents. Even though there are several chemicals that can be used as cleaning agents, sodium hydroxide (NaOH) has been widely used as a cleaning agent. Literature reports that main factors of this cleaning are sodium hydroxide concentration, treatment temperature and contact time. However, the most significant factors have not been determined nor the interactions between them. The aim of this study was to determine the most significant parameter and the interactions between sodium hydroxide concentration, treatment temperature and contact time. This was done using Box-Behnken experimental design. The results, based on ANOVA analyses, showed that temperature is the most significant factor and that interaction between sodium hydroxide concentration and treatment temperature is the most significant interaction.