期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
A three-dimensional numerical calculation of the wind-driven thermohaline and tide-induced Lagrangian residual current in the Bohai Sea 被引量:4
1
作者 Wang Hui, Su Zhiqing, Feng Shizuo and Sun Wenxin Ocean University of Qingdao, Qingdao 266003, China 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1993年第2期169-182,共14页
On the basis of a three-dimensional weakly nonliear theory of Lagrangian residual current in the Baroclinic shallow seas, a diagnostic numerical calculation of wind-driven, thermohaline and tide-induced Lagrangian res... On the basis of a three-dimensional weakly nonliear theory of Lagrangian residual current in the Baroclinic shallow seas, a diagnostic numerical calculation of wind-driven, thermohaline and tide-induced Lagrangian residual current in the Bohai Sea is made. The model involves the Richardson number in the eddy viscosity coefficient, wind, thcrmolialine and tidal effects in the focing terms. The runoff of the Huanghe River and a part of the Huanghai Warm Water coming from the Huanghai Sea through the Bohai Sea Strait is also considered. The velocity-splitting method is adopted. The wind-driven circu lation, thermohaline circulation and the tide-induced Lagrangian residual circulation are also obtained individually and analysed. The dynamics of the three main eddies in the Lagrangian mean circulation is discussed. Finally, the numerical result is partly verified with the observed data. 展开更多
关键词 A three-dimensional numerical calculation of the wind-driven thermohaline and tide-induced Lagrangian residual current in the Bohai Sea
在线阅读 下载PDF
Numerical calculation of drift current in wind waves
2
作者 Chen Zhan and Zhang Zhaoshun 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1992年第2期179-188,共10页
-Drift current induced by wind and waves is investigated with phase-averaged Navier-Stokes equation in which the Reynolds stress is closed by k-ε model. The governing equations are solved by the finite volume method ... -Drift current induced by wind and waves is investigated with phase-averaged Navier-Stokes equation in which the Reynolds stress is closed by k-ε model. The governing equations are solved by the finite volume method in a system of nonorthogonal coordinates which is fitted to the phase-averaged wave surface. The predicted drift current is fairly reasonable and the drag coefficient of sea-surface predicted with the newly developed interface conditions shows good agreement with previous measurements when breaking waves do not exist. 展开更多
关键词 Numerical calculation of drift current in wind waves
在线阅读 下载PDF
Efficient Calculation and Component Analysis of Fault Current in MMC-HVDC Grid
3
作者 Lixu Chen Jun Yan +2 位作者 Xiufang Jia Chengyong Zhao Jianzhong Xu 《CSEE Journal of Power and Energy Systems》 2025年第4期1744-1754,共11页
The investigation of the pole-to-pole(p2p)DC short-circuit fault current in a modular multilevel converter(MMC)based high-voltage direct current(HVDC)grid is of vital importance for protection design and parameter opt... The investigation of the pole-to-pole(p2p)DC short-circuit fault current in a modular multilevel converter(MMC)based high-voltage direct current(HVDC)grid is of vital importance for protection design and parameter optimization.Existing calculation methods for the p2p fault current primarily rely on differential equations based on the RLC equivalent of the MMC station and the RL model of DC transmission lines.Some of them also take the AC in-feed currents into account.However,these approaches all carry heavy burdens for the complex formation and solving processes of equations,and they can only obtain the numerical solution of the fault current.The analytic solution of explicit physical meaning cannot be acquired at present because of the complex coupling relationship among MMC terminals.To address these issues,this paper builds a simplified and generalized fault equivalence model for the DC grid under a p2p fault.This is due to the fact that the terminals having long electrical distances from the fault point have less impact on the fault current.Next,not only the efficient and accurate fault current calculation is achieved,but also the approximate superposition-based analytical solution of the fault current is derived.The component analysis of the fault current and the sensitivity analysis of the components are provided as well.The calculation method and the analysis are both validated in PSCAD/EMTDC. 展开更多
关键词 Analytical solution component analysis DC grid fault current calculation modular multilevel converter(MMC)
原文传递
DC Fault Current Calculation Method and Transient Characteristics of True Bipolar MMC-HVDC Systems
4
作者 Botong Li Yichao Liu +3 位作者 Bin Li Wenxin Wang Weijie Wen Xiaolong Chen 《CSEE Journal of Power and Energy Systems》 2025年第4期1704-1716,共13页
In this paper,the calculation method and transient characteristics of asymmetric faults in the DC side of a true bipolar system are studied.First,two typical MMC fault equivalent methods are analyzed,and comparison sh... In this paper,the calculation method and transient characteristics of asymmetric faults in the DC side of a true bipolar system are studied.First,two typical MMC fault equivalent methods are analyzed,and comparison shows that active RLC equivalent branches are more suitable for fault analyses of a true bipolar system.Second,considering the influence of mutual impedance between the poles in DC side,a DC fault current calculation method for a true bipolar systems is proposed.Finally,the characteristics of transient electrical quantities including fault current and DC voltage in the process of DC faults in true bipolar systems are analyzed and summarized to provide references for the design of DC line insulation and relay protection schemes. 展开更多
关键词 DC faults fault current calculation method transient characteristics true bipolar MMC-HVDC systems
原文传递
Grounding Faults in Series-connected-based Offshore Wind Farms:DC Link Current Control
5
作者 Gaopeng Guo Kunpeng Zha +3 位作者 Yuefeng Yang Fan Zhang Jiaxin Wang Weikun Xie 《CSEE Journal of Power and Energy Systems》 2025年第5期2128-2136,共9页
In series-connected-based offshore wind farms(SCOWFs),the bulky offshore platform,step-up transformer,and high voltage and large-scale converters can be eliminated.In SC-OWFs,grounding fault is an inevitable issue.In ... In series-connected-based offshore wind farms(SCOWFs),the bulky offshore platform,step-up transformer,and high voltage and large-scale converters can be eliminated.In SC-OWFs,grounding fault is an inevitable issue.In this study,the mathematical model of DC link in SC-OWFs is established.On this basis,this paper reveals characteristic of grounding faults in SC-OWFs and proposes a DC link current control strategy,consisting of feedback and feedforward control.Based on DC link current control and protection method,faulty part isolation from SC-OWF can be realized,and unfaulty part will operate normally.Finally,simulation and experimental results prove feasibility of the proposed DC control strategy and fault current calculation method. 展开更多
关键词 DC current control fault current calculation grounding fault series-connected-based offshore wind farms
原文传递
Asymmetrical Fault Current Calculation Method and Influencing Factors Analysis of Droop-Controlled Inverters 被引量:2
6
作者 Huimin Zhao Zhikang Shuai +3 位作者 Jun Ge An Luo Weimin Wu Z.John Shen 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期562-573,共12页
Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten th... Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten the safety of the microgrid. Therefore, it is imperative to conduct a comprehensive fault analysis of the inverter to guide the design of protection schemes. However, due to the complexity of droop control strategy, existing literatures have simplified asymmetric fault analysis of droop-controlled inverters to varying degrees. Therefore, accurate fault analysis of a droop-controlled inverter is needed. In this paper, by analyzing the control system, an accurate fault model is established. Based on this, a calculation method for instantaneous asymmetrical fault current is proposed. In addition, the current components and current characteristics are analyzed. It was determined that fault currents are affected by control loops, fault types, fault distance and nonlinear limiters. In particular, the influences of limiters on the fault model, fault current calculation and fault current characteristics were analyzed. Through detailed analysis, it was found that dynamics of the control loop cannot be ignored, the fault type and fault distance determine fault current level, and part of the limiters will totally change the fault current trend. Finally, calculation and experimental results verify the correctness of the proposed method. 展开更多
关键词 Asymmetrical fault analysis droop control fault current calculation method LIMITER transient fault characteristics
原文传递
DC Current Order Optimization Based Strategy for Recovery Performance Improvement of LCC-HVDC Transmission Systems 被引量:5
7
作者 Renlong Zhu Xiaoping Zhou +3 位作者 Shuchen Luo Lerong Hong Hanhang Yin Yifeng Liu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第3期1020-1026,共7页
For the safe and fast recovery of line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems after faults,a DC current order optimization based strategy is proposed.Considering the const... For the safe and fast recovery of line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems after faults,a DC current order optimization based strategy is proposed.Considering the constraint of electric and control quantities,the DC current order with the maximum active power transfer is calculated by Thevenin equivalent parameters(TEPs)and quasi-state equations of LCC-HVDC transmission systems.Meanwhile,to mitigate the subsequent commutation failures(SCFs)that may come with the fault recovery process,the maximum DC current order that avoids SCFs is calculated through imaginary commutation process.Finally,the minimum value of the two DC current orders is sent to the control system.Simulation results based on PSCAD/EMTDC show that the proposed strategy mitigates SCFs effectively and exhibits good performance in recovery. 展开更多
关键词 Line commutated converter(LCC) high-voltage direct current(HVDC) DC current order calculation subsequent commutation failure(SCF) RECOVERY
原文传递
DC Pole-to-Pole Short-Circuit Behavior Analysis of Modular Multilevel Converter 被引量:1
8
作者 Zhang Guoju Chen Yao Yue Chengyan 《Electricity》 2014年第4期34-38,共5页
This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system... This paper presents the behavior analysis of modular multilevel converter under DC pole-to-pole short-circuit fault, which is an important issue in fault management, electrical system design and MMC based power system protection and control. Firstly, the transient behavior is analyzed and the conduction overlap- ping angle γ, is defined. Secondly, seven possible short-circuit current paths induced by different γ values are identified, and the corresponding engineering short-circuit current calculation methods for both AC and DC sides are proposed. And then, the influences of impedance distribution factor κ and equivalent short-circuit resistance Rsc on short-circuit currents are elaborated the proposed analysis methods. Finally, case study is used to verify the effectiveness of 展开更多
关键词 short-circuit fault management short-circuit current practice calculation modular multilevelconverter (MMC) DC pole-to-pole short-circuit fault
原文传递
Visualization of oil spill at sea surface based on texture projection
9
作者 Changjun Zou Yong Yin +1 位作者 Xiuwen Liu Haijiang Li 《International Journal of Modeling, Simulation, and Scientific Computing》 EI 2017年第2期290-304,共15页
In view of the merits and demerits of current oil spill visualization methods,the paper involves a study on a new type of visualization approach targeting oil spill at sea.To be specific,the visualization of sea oil s... In view of the merits and demerits of current oil spill visualization methods,the paper involves a study on a new type of visualization approach targeting oil spill at sea.To be specific,the visualization of sea oil spill is implemented with the adoption of texture projection method.The texture projection-induced jaggedly edge is displayed in the performance test results.Under the circumstance,Gauss smoothing filter is introduced to secure the smooth convergence of texture edge and thus bring forth satisfactory dynamic visualization effect.Already,this means has already been successfully applied to the Oil Spill Emergency 3D Drilling System,which evidenced the validity and reliability of the new method. 展开更多
关键词 Oil spill at sea VISUALIZATION texture projection gauss smooth filtering numerical calculation of tidal current field.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部