期刊文献+
共找到1,358篇文章
< 1 2 68 >
每页显示 20 50 100
Study on 10 kVDC Powered Junction Box for A Cabled Ocean Observatory System 被引量:10
1
作者 陈燕虎 杨灿军 +2 位作者 李德骏 金波 陈鹰 《China Ocean Engineering》 SCIE EI CSCD 2013年第2期265-275,共11页
A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/s... A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments is developed. A 10 kV direct current (kVDC) with up to 10 kW power, along with l Gigabit/sec Ethemet communication, can be transmitted from the shore to the seafloor through an umbilical armored cable. A subsea junction box is fixed at a cable terminal, enabling the extension of up to nine connections. The box consists of three main pressure vessels that perform power conversion, power distribution, and real-time communication functions. A method of stacking modules is used to design the power conversion system in order to reduce the 10 kV voltage to levels that can power the attached instruments. A power distribution system and an Ethemet communication system are introduced to control the power supply and transmit data or commands between the terminals and the shore station, respectively. Specific validations of all sections were qualified in a laboratory environment prior to the sea trial. The ocean observatory system was then deployed at the coast of the East China Sea along with three in situ instruments for a 14-day test. The results show that this high voltage-powered observatory system is effective for subsea long-term and real-time observations. 展开更多
关键词 cabled ocean observatory high voltage REAL-TIME power delivery heat dissipation
在线阅读 下载PDF
Development of a direct current power system for a multi-node cabled ocean observatory system 被引量:8
2
作者 Yan-hu CHEN Can-jun YANG +2 位作者 De-jun LI Bo JIN Ying CHEN 《Journal of Zhejiang University-Science C(Computers and Electronics)》 SCIE EI 2012年第8期613-623,共11页
Due to the shortage of suitable research methods for real-time and long-term observation of oceans,an innovative approach that can provide abundant power and wide bandwidth is being developed worldwide for undersea in... Due to the shortage of suitable research methods for real-time and long-term observation of oceans,an innovative approach that can provide abundant power and wide bandwidth is being developed worldwide for undersea instruments.In this paper,we develop a direct current(DC) power system which is applied to a multi-node cabled ocean observatory system named ZERO(Zhejiang University Experimental and Research Observatory).The system addresses significant issues ranging from terrestrial facility to subsea infrastructure,and focuses on using appropriate methods to deal with several key challenges,including delivery,conversion,distribution,and management of power,and heat dissipation in pressure vessels.A basic laboratory platform consisting of a shore station,a primary node in a water tank,and a secondary node in a deep-sea simulation chamber under 42 MPa pressure was built and fully tested.An improved secondary node was deployed in Monterey Bay in California for a deep-sea trial.An 11-day laboratory test and a half-year sea trial proved that the DC power system based on our proposed methods is viable for the underwater multi-node observatory system. 展开更多
关键词 cabled ocean observatory system DC power system Heat dissipation Deep sea
原文传递
Use of a coded voltage signal for cable switching and fault isolation in cabled seafloor observatories 被引量:2
3
作者 Zhi-feng ZHANG Yan-hu CHEN +3 位作者 De-jun LI Bo JIN Can-jun YANG Jun WANG 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2018年第11期1328-1339,共12页
Cabled seafloor observatories play an important role in ocean exploration for its long-term, real-time, and in-situ observation characteristics. In establishing a permanent, reliable, and robust seafloor observatory, ... Cabled seafloor observatories play an important role in ocean exploration for its long-term, real-time, and in-situ observation characteristics. In establishing a permanent, reliable, and robust seafloor observatory, a highly reliable cable switching and fault isolation method is essential. After reviewing the advantages and disadvantages of existing switching methods, we propose a novel active switching method for network configuration. Without additional communication path requirements, the switching method provides a way to communicate with a shore station through an existing power transmission path. A coded voltage signal with a distinct sequence is employed as the communication medium to transmit commands. The analysis of the maximum bit frequency of the voltage signals guarantees the accuracy of command recognition. A prototype based on the switching method is built and tested in a laboratory environment, which validated the functionality and reliability of the method. 展开更多
关键词 cabled SEAFLOOR OBSERVATORIES CABLE SWITCHING and fault ISOLATION CODED voltage signal Maximum bit frequency
原文传递
Optimal communication frequency for switching cabled ocean networks with commands carried over the power line 被引量:1
4
作者 Yan-hu CHEN Yu-jia ZANG +1 位作者 Jia-jie YAO Gul MUHAMMAD 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2019年第10期1331-1343,共13页
Cabled ocean networks with tree or ring topologies play an important role in real-time ocean exploration. Due to the time-consuming need for field maintenance, cable switching technology that can actively switch the p... Cabled ocean networks with tree or ring topologies play an important role in real-time ocean exploration. Due to the time-consuming need for field maintenance, cable switching technology that can actively switch the power on/off on certain branches of the network becomes essential for enhancing the reliability and availability of the network. In this paper, a novel switching-control method is proposed, in which we invert the power transmission polarity and use the current on the power line as the digital signal at low frequency to broadcast information with the address and commands to the network, and the corresponding branching unit (BU) can decode and execute the switching commands. The cable's parasitic parameters, the network scale, and the number of BUs, as the influencing factors of the communication frequency on the power line, are theoretically studied and sim-ulated. An optimized frequency that balances the executing accuracy and rate is calculated and proved on a simulated prototype. The results showed that the cable switching technology with optimized frequency can enhance the switching accuracy and con-figuring rate. 展开更多
关键词 CABLE SWITCHING cabled OCEAN network Branching unit TRANSMISSION LINE theory COMMUNICATION frequency
原文传递
Design and Control of a Bionic Inspection Robot for Suspension Bridge Main Cables
5
作者 Shengkai Liu Chao Wang +1 位作者 Xiaoqiang Yuan Ning Ding 《Journal of Bionic Engineering》 2026年第1期159-174,共16页
The main cable is the primary load-bearing component of a suspension bridge,continuously exposed to harsh environmental conditions,such as wind and rain,throughout the year.These adverse conditions contribute to varyi... The main cable is the primary load-bearing component of a suspension bridge,continuously exposed to harsh environmental conditions,such as wind and rain,throughout the year.These adverse conditions contribute to varying degrees of degradation and damage to the main cable,necessitating regular inspections to prevent catastrophic failures.Traditional manual inspection methods not only suffer from low efficiency but also pose significant safety risks to personnel.To address these challenges and ensure the safe and effective inspection of suspension bridge main cables,this study introduces a novel cooperative climbing robot,designated as Main Cable Robot Version II(CCRobot-M-II),inspired by the locomotion of the inchworm.The robot employs an alternating opening and closing mechanism of four gripper sets,mimicking the inchworm's movement to achieve efficient crawling along the suspension bridge handrails.This paper provides a comprehensive analysis of the structural design,key components,and motion mechanisms of CCRobot-M-II.A detailed force analysis of the robot's crawling process is also presented,followed by the design of the control system and the development of an efficient motion control algorithm.Laboratory experiments demonstrate that the robot achieves a positional error of 00.64%during crawling,with a maximum average crawling speed of 7.6 m/min.Furthermore,the biomimetic design enables the robot to overcome obstacles up to 30 mm in height and possess the capability to handle suspension bridge cables with spans ranging from 740 to 1100 mm.Finally,CCRobot-M-II successfully conducted an inspection of the main cable on a suspension bridge,marking the world's first successful deployment of a climbing robot for main cable inspection on a suspension bridge. 展开更多
关键词 Bionic design Suspension bridge Main cable inspection Climbing robot Motion control
在线阅读 下载PDF
Pull-out capacity and energy absorption of cable bolts under impact loading
6
作者 Adel Mottahedi Naj Aziz +1 位作者 Alex Remennikov Ali Mirzaghorbanali 《International Journal of Mining Science and Technology》 2026年第1期23-42,共20页
This study investigates the performance of high-strength cable bolts under impact loading conditions representative of rock bursts in underground environments.Although widely used,the dynamic behaviour of these cable ... This study investigates the performance of high-strength cable bolts under impact loading conditions representative of rock bursts in underground environments.Although widely used,the dynamic behaviour of these cable bolts has received limited experimental attention,and their effectiveness in seismically active zones remains a subject of ongoing debate.To address this gap,a reverse pull-out test machine integrated with a drop hammer rig was employed.Tests were conducted on 70-t SUMO bulbed and non-bulbed cable bolts with encapsulation lengths of 300 and 450 mm,subjected to an impact energy of 14.52 k J.Results indicate that non-bulbed cables,despite showing lower initial peak loads(average 218 vs.328 k N for bulbed cables at 300 mm encapsulation),demonstrated superior energy absorption(average 11.26 vs.8.75 k J)and displacement capacity(average 48.40 vs.36.25 mm).Increasing the encapsulation length for bulbed cables led to a reduction in initial peak load but improved displacement and energy absorption.The dominant failure mechanism was debonding at the cable-grout interface,characterised by frictional sliding and cable rotation.These findings provide new insights into the energy dissipation mechanisms of cables and support the development of more resilient ground support systems for dynamically active conditions. 展开更多
关键词 Rock reinforcement Cable bolt Impact loading Pull-out testing Mine seismicity Rock burst
在线阅读 下载PDF
Experimental and Numerical Optimization of Prestressed Anchor Cable Support for In-Situ Large-Span Tunnel Expansion with an Energy Balance Framework
7
作者 Ying Zhu Minghui Hu +5 位作者 Shengxu Wang Xiaoliang Dong Xuewen Xiao Richeng Liu Meng Wang Zheng Yuan 《Computer Modeling in Engineering & Sciences》 2026年第2期550-585,共36页
In-situ enlargement of super-large-span tunnels can intensify excavation-induced unloading in the surrounding rock,increasing deformation demand and failure risk during construction.This study combines laboratory mode... In-situ enlargement of super-large-span tunnels can intensify excavation-induced unloading in the surrounding rock,increasing deformation demand and failure risk during construction.This study combines laboratory model tests with FLAC3D simulations to evaluate the stabilizing role of prestressed anchor cables and to establish an energy-balance framework for support optimization.Comparative model tests of existing and enlarged tunnel sections,with and without anchors,show that reinforcement increases load-carrying capacity,reduces displacement,and confines damage to more localized zones.The numerical simulations reproduce displacement fields,shear-strain localization,and plastic-zone evolution with good agreement against the experimental observations.The energy framework is implemented in the in-situ simulations by quantifying unloading-related energy release in the rock mass and reinforcement work contributed by the anchors,and by introducing an energy release–reinforcement ratio as a stability indicator.Parametric analyses indicate that anchor length,spacing,and prestress influence stability in a nonlinear manner,with diminishing returns once reinforcement extends beyond the mechanically dominant deformation zone.An efficient parameter window is identified that improves deformation and yielding control while avoiding unnecessary reinforcement.The results provide an energy-consistent and design-oriented basis for prestressed anchorage selection in large-span tunnel expansion. 展开更多
关键词 Large-span tunnel anchor cable support tunnel expansion energy balance FLAC3D parameter optimization
在线阅读 下载PDF
Identification of Key Parameters for Temporary Guy Ropes in Sloping Central Tower Column and Brace Construction
8
作者 Renfei Chang Liqiang Jin +2 位作者 Haihui Xie Kai Zhang Musheng Ye 《Structural Durability & Health Monitoring》 2026年第1期161-177,共17页
To investigate the impact of temporary structures on the mechanical behavior of shaped bridge towers during the construction process,the Dianbu River Special Bridge was selected as the engineering background.A finite ... To investigate the impact of temporary structures on the mechanical behavior of shaped bridge towers during the construction process,the Dianbu River Special Bridge was selected as the engineering background.A finite element model of the middle tower column during the construction stage was established using ABAQUS to analyze the effects of key parameters,including the angle and pretension of temporary cables,as well as the wall thickness and diameter of temporary diagonal braces.The study examines how these parameters influence the stresses at the towergirder consolidation.The results indicate that the angle of temporary cables significantly affects the tensile stresses at the tower-girder consolidation,while its impact on compressive stresses is minimal.Among all parameters,the pretension of temporary cables has the most pronounced effect on the stresses at the tower-girder consolidation.In contrast,the wall thickness of temporary diagonal braces has only a minor influence,whereas the diameter of temporary diagonal braces has an almost negligible impact.These findings provide valuable insights for optimizing the design and arrangement of temporary support structures in similar bridge construction projects. 展开更多
关键词 Anisotropic single tower cable-stayed bridge influence degree identification temporary cables temporary diagonal braces construction control
在线阅读 下载PDF
FLAC^(3D)锚杆(索)拉伸-剪切破断单元的二次开发及数值实现 被引量:4
9
作者 孟庆彬 宋子鸣 +3 位作者 刘滨 李为腾 王从凯 辛学奎 《采矿与安全工程学报》 北大核心 2025年第1期180-193,共14页
FLAC^(3D)内嵌的Cable原始单元不具有拉伸或剪切破断失效属性,高估了锚杆(索)的支护能力及对巷道围岩的控制效果,存在巷道支护失效的安全隐患。为解决Cable原始单元无法实现锚杆(索)破断失效的问题,提出了锚杆(索)拉伸、剪切、拉剪破断... FLAC^(3D)内嵌的Cable原始单元不具有拉伸或剪切破断失效属性,高估了锚杆(索)的支护能力及对巷道围岩的控制效果,存在巷道支护失效的安全隐患。为解决Cable原始单元无法实现锚杆(索)破断失效的问题,提出了锚杆(索)拉伸、剪切、拉剪破断判据;基于Fish语言构建了考虑拉伸、剪切及拉剪作用的修正Cable破断单元模型及数值分析流程,完成了FLAC^(3D)中锚杆(索)3种破断行为数值模拟的二次开发;开展了锚杆(索)破断模拟试验和锚喷支护巷道应用分析,修正的Cable拉伸-剪切破断单元模型的数值模拟试验结果符合预期,所开发的Cable破断单元模型兼有锚杆(索)拉伸和剪切破断的属性,较好地实现了拉剪荷载作用下锚杆(索)破断失效行为的模拟,数值模拟的锚杆(索)力学行为与工程实际更为相符。随着巷道埋深(应力水平)的增加,当锚杆(索)的变形量或受力状态达到其拉伸-剪切破断条件时,锚杆(索)则破断失效而无法再继续控制巷道围岩变形,锚杆(索)均有自身的支护适用性。 展开更多
关键词 FLAC^(3D)二次开发 锚杆(索)破断失效 Cable破断单元 支护适用性
原文传递
有线电视Cable接入网演进方案研究 被引量:1
10
作者 谭诗荣 张宇 刘光 《广播电视网络》 2025年第2期81-85,共5页
本文对有线电视Cable接入网向全光接入网的演进进行了痛点分析,研究了当前可能采取的技术路线,遵循“业务引领、精准投资、光进铜退、资源沿用、落地可行”的原则,从不同维度对各种技术要素进行了对比分析,提出了切实可行的融合演进策略。
关键词 Cable接入网技术 融合演进 技术路线
在线阅读 下载PDF
Analysis of wind-induced vibration response characteristics of multispan double-layer cable photovoltaic support structure 被引量:2
11
作者 ZOU Lianghao WANG Jian +2 位作者 SONG Jie ZHOU Rui WANG Hao 《Journal of Southeast University(English Edition)》 2025年第1期37-43,共7页
To investigate the wind⁃induced vibration re⁃sponse characteristics of multispan double⁃layer cable photo⁃voltaic(PV)support structures,wind tunnel tests using an aeroelastic model were carried out to obtain the wind⁃... To investigate the wind⁃induced vibration re⁃sponse characteristics of multispan double⁃layer cable photo⁃voltaic(PV)support structures,wind tunnel tests using an aeroelastic model were carried out to obtain the wind⁃induced vibration response data of a three⁃span four⁃row double⁃layer cable PV support system.The wind⁃induced vibration characteristics with different PV module tilt angles,wind speeds,and wind direction angles were analyzed.The results showed that the double⁃layer cable large⁃span flexible PV support can effectively control the wind⁃induced vibration response and prevent the occur⁃rence of flutter under strong wind conditions.The maxi⁃mum value of the wind⁃induced vibration displacement of the flexible PV support system occurs in the windward first row.The upstream module has a significant shading effect on the downstream module,with a maximum effect of 23%.The most unfavorable wind direction angles of the structure are 0°and 180°.The change of the wind direction angle in the range of 0°to 30°has little effect on the wind vi⁃bration response.The change in the tilt angle of the PV modules has a greater impact on the wind vibration in the downwind direction and a smaller impact in the upwind di⁃rection.Special attention should be paid to the structural wind⁃resistant design of such systems in the upwind side span. 展开更多
关键词 double⁃layer cable photovoltaic support aero⁃elastic model wind tunnel test wind⁃induced vibration re⁃sponse
在线阅读 下载PDF
Effect of Core Structure on the Mechanical and Electromagnetic Properties of High-Temperature Superconducting Cables 被引量:1
12
作者 Jiangtao Yan Yuanwen Gao 《Acta Mechanica Solida Sinica》 2025年第1期14-24,共11页
Research on the mechanical–electrical properties is crucial for designing and preparing high-temperature superconducting(HTS)cables.Various winding core structures can influence the mechanical–electrical behavior of... Research on the mechanical–electrical properties is crucial for designing and preparing high-temperature superconducting(HTS)cables.Various winding core structures can influence the mechanical–electrical behavior of cables,but the impact of alterations in the winding core structure on the mechanical–electrical behavior of superconducting cables remains unclear.This paper presents a 3D finite element model to predict the performance of three cables with different core structures when subjected to transverse compression and axial tension.The three cables analyzed are CORC(conductor-on-round-core),CORT(conductor-on-round-tube),and HFRC(conductor-on-spiral-tube).A parametric analysis is carried out by varying the core diameter and inner-to-outer diameter ratio.Results indicate that the CORT cable demonstrates better performance in transverse compression compared to the CORC cable,aligning with experimental data.Among the three cables,the HFRC cables exhibit the weakest resistance to transverse deformation.However,the HFRC cable demonstrates superior tensile deformation resistance compared to the CORT cable,provided that the transverse compression properties are maintained.Finite element results also show that the optimum inner-to-outer diameter ratios for achieving the best transverse compression performance are approximately 0.8 for CORT cables and 0.6 for HFRC cables.Meanwhile,the study explores the effect of structural changes in HTS cable winding cores on their electromagnetic properties.It recommends utilizing small tape gaps,lower frequencies,and spiral core construction to minimize eddy losses.The findings presented in this paper offer valuable insights for the commercialization and practical manufacturing of HTS cables. 展开更多
关键词 Superconducting cables Winding core structure Transverse compression Axial tension Eddy loss
原文传递
Roof deformation of the Beishan Rock Carvings with negative Poisson's ratio anchor support under varied precipitation conditions 被引量:1
13
作者 YANG Peixi TAO Zhigang +1 位作者 YANG Xiaojie LI Xiaodan 《Journal of Mountain Science》 2025年第8期3078-3091,共14页
Beishan Rock Carvings in Chongqing,a renowned cultural heritage site in China,flourished during the Tang and Song dynasties and are often referred to as the“Stone Carving Art Museum of the Tang and Song Dynasties.”C... Beishan Rock Carvings in Chongqing,a renowned cultural heritage site in China,flourished during the Tang and Song dynasties and are often referred to as the“Stone Carving Art Museum of the Tang and Song Dynasties.”Cave 168 is a key component of the Beishan Rock Carvings.At present,several through-going cracks have developed in the roof of Cave 168,severely compromising the structural stability of the grotto.The early internal steel plate supports have suffered severe corrosion and can no longer provide effective reinforcement.In addition,the presence of steel columns obstructs visitor access and negatively affects the viewing experience.A new reinforcement method is urgently needed.Therefore,studying the deformation patterns of the structure is of critical importance.This study analyzes the stratigraphic parameters and fracture distribution of Cave 168,considering key influencing factors such as rainfall,self-weight,and the overlying Quaternary soil.On-site monitoring and physical model experiments were conducted to evaluate the changes in roof crack width and displacement before and after reinforcement with negative Poisson's ratio(NPR)anchor cables.The results reveal that the roof of Cave 168 contains several through-going cracks and numerous microcracks,which serve as infiltration channels for surface water.These accelerate the softening of the mudstone and pose a significant threat to the cave's structural safety.During the experiment,the main change in the crack exhibited a“semi-archshaped”propagation pattern.In the first ten minutes,as the rock transitioned from dry to moist conditions,a slight crack closure was observed.As rainfall continued,crack propagation accelerated.After rainfall ceased,crack width remained stable over a short period.Under NPR anchor support,the influence of rainfall on roof settlement was effectively mitigated,ensuring the safety and stability of the roof.The NPR anchors successfully limited the roof settlement to within 0.3 mm and provided effective control over both total and differential settlement.These findings offer valuable insights into the application of NPR anchor cables in the conservation of grotto heritage structures. 展开更多
关键词 Grotto stability Physical model experiment RAINFALL NPR anchor(cable) On-site monitoring
原文传递
柔性系固包装系统数值模拟关键技术
14
作者 王虎 唐文评 《包装学报》 2025年第1期47-55,共9页
对重型包装柔性系固系统的数值模拟分析方法进行了研究。利用workbench的 CABLE280单元模拟捆扎系统中的柔索结构,探究了该单元对捆扎物几何形状、绳索预紧力、绳索松弛特性的模拟能力。分析了捆扎物几何形状对绳索模拟精度的影响;设计... 对重型包装柔性系固系统的数值模拟分析方法进行了研究。利用workbench的 CABLE280单元模拟捆扎系统中的柔索结构,探究了该单元对捆扎物几何形状、绳索预紧力、绳索松弛特性的模拟能力。分析了捆扎物几何形状对绳索模拟精度的影响;设计了柔索松弛特性仿真实验,研究了CABLE280单元对柔索的模拟能力。研究结果表明:CABLE280单元能够模拟绳索的预应力及松弛特性,通过对捆扎物的边缘结构进行几何处理及预应力施加,CABLE280能够用于模拟包装系统的柔索结构。 展开更多
关键词 柔性系固 数值模拟分析 CABLE280单元 松弛特性 重型包装
在线阅读 下载PDF
HVDC Cable System Testing
15
作者 Giovanni Mazzanti 《High Voltage》 2025年第6期1349-1370,共22页
This paper reviews the existing testing techniques for high voltage direct current(HVDC)cable systems,following as a backbone the structure of CIGRE Technical Brochure(TB)852:2021‘Recommendations for testing DC extru... This paper reviews the existing testing techniques for high voltage direct current(HVDC)cable systems,following as a backbone the structure of CIGRE Technical Brochure(TB)852:2021‘Recommendations for testing DC extruded cable systems for power transmission at a rated voltage up to 800 kV’because it has a fairly similar structure to CIGRE TB 853:2021 for lapped DC cables,and especially because of the impressive spread of HVDC extruded cables experienced worldwide in the last 25 years.The review considers development tests,pre-qualification tests,extension of qualification test,type tests(with hints at IEEE 1732-2017 for space charge measurements in the qualification of HVDC extruded cables),routine tests(with hints at IEEE 2862-2020 for routine tests of HVDC extruded cable system joints),sample tests and after installation tests.The review also analyses CIGRE TB 853 for lapped HVDC cable systems,as these cables remain unbeaten for submarine applications at the highest sea depths.The main novelties of CIGRE TB 852 and 853 with respect to previous standards for HVDC cable systems(mainly CIGRE TB 496 and IEC 62895 for extruded cables and CIGRE Electra 189:2000 for lapped cables)are put under the spotlight-with focus on the so-called temporary over-voltage tests-together with the limits and gaps of CIGRE TB 852.The main HVDC cable system testing equipment that is usually employed for electro-thermal tests is also treated.Emphasis is given to CIGRE TB 490 to treat the peculiarities of submarine cable systems,as well as to mechanical tests,having CIGRE TB 623 as a reference,with particular focus on the special sea trial tests.An example of an innovative sea trial testing procedure is shown,which is the outcome of a fruitful partnership between a cable manufacturer and the national Transmission System Operator in Italy. 展开更多
关键词 lapped dc cablesand cable systems testing techniques power transmission testing dc extruded cable systems hvdc extruded cables CIGRE TB HVDC
在线阅读 下载PDF
vip Editorial:Research Progress and Technology Development of HVDC Cable:Part I
16
作者 Shengtao Li Lisheng Zhong +4 位作者 Davide Fabiani Chong Zhang Shihang Wang Jinghui Gao Roland D.Zhang 《High Voltage》 2025年第6期1347-1348,共2页
High-voltage direct current(HVDC)cables are growing rapidly all over the world due to the development of offshore wind power interconnections,cross-island power interconnections,etc.Extensive research has been conduct... High-voltage direct current(HVDC)cables are growing rapidly all over the world due to the development of offshore wind power interconnections,cross-island power interconnections,etc.Extensive research has been conducted and many achievements have been made in the study of theoretical issues of HVDC insulation,structural design and manufacture of HVDC cables with the corresponding accessories,as well as in condition monitoring technology. 展开更多
关键词 condition monitoring technology cables high voltage direct current hvdc cables offshore wind power interconnectionscross island PROGRESS TECHNOLOGY research
在线阅读 下载PDF
Preface for the Special Issue on“Safety of Slender Composite Flexible Structures in Ocean Engineering”
17
作者 YANG Zhi-xun 《China Ocean Engineering》 2025年第5期791-792,共2页
The ocean holds abundant petroleum,natural gas,and mineral resources that form an essential material foundation for the sustainable development of modern society.The safe and efficient exploitation of these resources ... The ocean holds abundant petroleum,natural gas,and mineral resources that form an essential material foundation for the sustainable development of modern society.The safe and efficient exploitation of these resources depends heavily on various slender,composite,flexible structures,including umbilical cables,dynamic power cables for offshore wind turbines,petroleum pipelines(both bonded and unbonded),deep-sea mining risers,and LNG cryogenic flexible hoses.These structures feature highly complex configurations and incur substantial design and manufacturing costs,while operating in environments far more severe and variable than those of onshore pipelines.They must withstand multisource stochastic loads generated by the combined action of wind,waves,currents,and tides,and maintain robustness under extreme conditions such as typhoons,earthquakes,and explosions. 展开更多
关键词 sustainable development mineral resources ocean engineering umbilical cables offshore wind turbinespetroleum pipelines both umbilical cablesdynamic power cables safety lng cryogenic flexible hosesthese
在线阅读 下载PDF
Development and in situ application of actively heated fiber Bragg grating cable for soil water content measurement
18
作者 Mengya Sun Jie Liu +6 位作者 Jin Liu Xing Zheng Xiaoyan Li Junyi Guo Yunqiang Wang Yongping Tong Bin Shi 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第7期4579-4590,共12页
The actively heated fiber-optic(AHFO)technology has emerged as a frontier and hotspot in soil water content measurement,offering advantages such as easy installation,large-scale distributed measurement capability,and ... The actively heated fiber-optic(AHFO)technology has emerged as a frontier and hotspot in soil water content measurement,offering advantages such as easy installation,large-scale distributed measurement capability,and resistance to electromagnetic interference.However,current AHFO water content sensors fail to simultaneously achieve high precision,applicability for deep soil,and automated real-time monitoring,thereby limiting their development and application.Therefore,this study introduces a novel actively heated fiber Bragg grating(AH-FBG)cable.Laboratory tests were conducted to assess the heating uniformity of the AH-FBG cable and to establish the temperature characteristic value(T_(t))-soil water content(θ)calibration formula for water content measurement.Subsequently,AH-FBG cables were deployed for in situ soil water content monitoring in a test pit on the Loess Plateau.Through two-year monitoring data verified the accuracy of the AH-FBG cable and elucidated the spatiotemporal distribution of in situ loess water content.Laboratory results demonstrated superior heating uniformity of AHFBG cable,with a T_(t) standard deviation of approximately 0.3℃.In the field,the AH-FBG cable exhibited excellent performance in soil water content measurement,achieving a high accuracy of 0.023 cm^(3)/cm^(3).Further analysis revealed that the θ fluctuation predominantly occurred within a 10 m depth from the soil surface,with an overall upward trend over the two-year monitoring period;the response of shallow θ to precipitation was significant but exhibited increasing hysteresis with depth;frequent precipitation significantly enhanced water infiltration depth.This study provides technical guidance for highprecision,quasi-distributed,automated and real-time water content measurement of deep soil. 展开更多
关键词 Soil water content Actively heated fiber Bragg grating(AHFBG)cable Sensing cable In situ monitoring Spatiotemporal distribution APPLICABILITY
在线阅读 下载PDF
Impacts and depositional behaviors of debris flows on natural boulder-negative Poisson's ratio anchor cable baffles
19
作者 Feifei Zhao Manchao He +1 位作者 Qiru Sui Zhigang Tao 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第2期946-959,共14页
The impacts of natural boulders carried by debris flows pose serious risks to the safety and reliability of structures and buildings.Natural boulders can be highly random and unpredictable.Consequently,boulder control... The impacts of natural boulders carried by debris flows pose serious risks to the safety and reliability of structures and buildings.Natural boulders can be highly random and unpredictable.Consequently,boulder control during debris flows is crucial but difficult.Herein,an eco-friendly control system featuring anchoring natural boulders(NBs)with(negative Poisson's ratio)NPR anchor cables is proposed to form an NB-NPR baffle.A series of flume experiments are conducted to verify the effect of NB-NPR baffles on controlling debris flow impact.The deployment of NB-NPR baffles substantially influences the kinematic behavior of a debris flow,primarily in the form of changes in the depositional properties and impact intensities.The results show that the NB-NPR baffle matrix successfully controls boulder mobility and exhibits positive feedback on solid particle deposition.The NB-NPR baffle group exhibits a reduction in peak impact force ranging from 29%to 79%compared to that of the control group in the basic experiment.The NPR anchor cables play a significant role in the NB-NPR baffle by demonstrating particular characteristics,including consistent resistance,large deformation,and substantial energy absorption.The NB-NPR baffle innovatively utilizes the natural boulders in a debris flow gully by converting destructive boulders into constructive boulders.Overall,this research serves as a basis for future field experiments and applications. 展开更多
关键词 Debris flow Natural boulders NPR anchor cable BAFFLE Depositional behavior Impact
在线阅读 下载PDF
Wire Rope Inspection Robots:A Review
20
作者 SUN Bowen YANG Jianhua +3 位作者 LI Baofeng LI Shangyuan WANG Liang XU Zhongqi 《Journal of Shanghai Jiaotong university(Science)》 2025年第6期1144-1161,共18页
Wire rope inspection robot is an important tool for wire rope condition monitoring and maintenance,which can accurately locate and judge the damage of wire rope.In addition,the wire rope inspection robot can also be u... Wire rope inspection robot is an important tool for wire rope condition monitoring and maintenance,which can accurately locate and judge the damage of wire rope.In addition,the wire rope inspection robot can also be used for cable inspection.First,the crawling structure and crawling mode of the wire rope inspection robot are reviewed,and the characteristics and existing problems of each crawling mode are analyzed separately.Next,the drive mode of the wire rope inspection robot is discussed,the types of commonly used motors are introduced,and the advantages and disadvantages of drive motors and the control modes are compared.Then,the method and principle of the non-destructive detection of the wire rope inspection robot are expounded,and the commonly used detection methods and existing deficiencies are compared.After that,the types of communication modes are compared and analyzed,and the types of wireless communication modes are also introduced.Finally,the current difficult problems of the wire rope inspection robot are summarized,and the future development trend of the wire rope inspection robot is prospected. 展开更多
关键词 wire rope CABLE non-destructive detection inspection robot
原文传递
上一页 1 2 68 下一页 到第
使用帮助 返回顶部