期刊文献+
共找到102,591篇文章
< 1 2 250 >
每页显示 20 50 100
Study on the Mechanical Performance of Wet Concrete Joints in Large-Span Composite Steel-Concrete Cable-Stayed Bridges
1
作者 Yang Wang Zhe Wu +1 位作者 Kaixing Zhang Youzhi Wang 《Structural Durability & Health Monitoring》 2025年第3期613-642,共30页
A steel-concrete composite cable-stayed bridge features integrated steel girders and concrete decks linked by shear connectors to support loads,but stress concentration in wet joints can lead to cracking.In-situ tests... A steel-concrete composite cable-stayed bridge features integrated steel girders and concrete decks linked by shear connectors to support loads,but stress concentration in wet joints can lead to cracking.In-situ tests were conducted on key sections of steel-concrete composite cable-stayed bridges to analyze the stress-strain evolution of wet joints under environmental factors,constraints,and complex construction processes.The coordinated working performance of the bridge decks was also analyzed.The results indicate that temperature is the key factor affecting the stresses and strains in wet joint concrete.Approximately 7 days after casting the wet joint concrete,the strains at each measurement point of the wet joint are approximately negatively correlated with the temperature change at the measurement point.Different locations within the wet joints have respective impacts,presenting potential weak points.Construction conditions have a certain impact on the stress and strain of the wet joint.The top deck of the steel box girder is not fully bonded to the bottom surface of the wet joints,resulting in a certain strain difference after loading.To further analyze the cooperative working performance of steel box girders and concrete wet joint bridge deck systems,finite element analysis was conducted on composite girder structures.A stiffness calculation method for shear connectors based on numerical simulation was proposed.The results indicate that strain differences can cause interface slip in composite girders.This slip leads to increased deflection of the composite girders and increased tensile stress in the bottom plate of the steel box girders.This study clarifies the stress conditions and factors affecting wet joints during construction,preventing early cracking,and offers precise data for a full bridge finite element model. 展开更多
关键词 Large-span cable-stayed bridges steel-concrete composite girders wet joints mechanical performance cooperative working performance in-situ tests finite element analysis
在线阅读 下载PDF
Seismic fragility analysis of three-tower cable-stayed bridges with different connection configurations 被引量:1
2
作者 Chen Chen Liu Jinlong +1 位作者 Lin Junqi Li Suchao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第4期1009-1027,共19页
Seismic fragility analysis of three-tower cable-stayed bridges with three different structural systems,including rigid system(RS),floating system(FS),and passive energy dissipation system(PEDS),is conducted to study t... Seismic fragility analysis of three-tower cable-stayed bridges with three different structural systems,including rigid system(RS),floating system(FS),and passive energy dissipation system(PEDS),is conducted to study the effects of connection configurations on seismic responses and fragilities.Finite element models of bridges are established using OpenSees.A new ground motion screening method based on the statistical characteristic of the predominant period is proposed to avoid irregular behavior in the selection process of ground motions,and incremental dynamic analysis(IDA)is performed to develop components and systems fragility curves.The effects of damper failure on calculated results for PEDS are examined in terms of seismic response and fragility analysis.The results show that the bridge tower is the most affected component by different structural systems.For RS,the fragility of the middle tower is significantly higher than other components,and the bridge failure starts from the middle tower,exhibiting a characteristic of local failure.For FS and PEDS,the fragility of the edge tower is higher than the middle tower.The system fragility of RS is higher than FS and PEDS.Taking the failure of dampers into account is necessary to obtain reliable seismic capacity of cable-stayed bridges. 展开更多
关键词 seismic fragility cable-stayed bridge connection configuration viscous damper comparison analysis
在线阅读 下载PDF
Application of uncertain type of AHP to condition assessment of cable-stayed bridges 被引量:15
3
作者 黄侨 任远 林阳子 《Journal of Southeast University(English Edition)》 EI CAS 2007年第4期599-603,共5页
In order to guarantee the safety service and life-span of long-span cable-stayed bridges, the uncertain type of analytic hierarchy process (AHP) method is adopted to access the bridge condition. The correlative theo... In order to guarantee the safety service and life-span of long-span cable-stayed bridges, the uncertain type of analytic hierarchy process (AHP) method is adopted to access the bridge condition. The correlative theory and applied objects of uncertain type of AHP are introduced, and then the optimal transitive matrix method is chosen to calculate the interval number judgment matrix, which makes the weights of indices more reliable and accurate. Finally, with Harbin Songhua River Cable-Stayed Bridge as an example, an index system and an assessment model are proposed for the condition assessment of this bridge, and by using uncertain type of AHP, the weights of assessment indices are fixed and the final assessment results of the bridge are calculated, which proves the feasibility and practicability of this method. The application of this assessment method can provide the scientific basis for maintenance and management of long-span cable-stayed bridges. 展开更多
关键词 cable-stayed bridge condition assessment uncertain type of analytic hierarchy process interval number judgment matrix
在线阅读 下载PDF
Probability evaluation method for cable safety of long-span cable-stayed bridges 被引量:8
4
作者 朱劲松 肖汝诚 何立志 《Journal of Southeast University(English Edition)》 EI CAS 2007年第1期92-97,共6页
A method of cable safety analysis is proposed for safety evaluation of long-span cable-stayed bridges. The Daniels' effect and the probability of broken wires in the cable are introduced to develop the cable strength... A method of cable safety analysis is proposed for safety evaluation of long-span cable-stayed bridges. The Daniels' effect and the probability of broken wires in the cable are introduced to develop the cable strength model and the reliability assessment technique for long-span cable-stayed bridges based on the safety factors analysis of stay cables in service. As an application of the proposed model, the cable safety reliability of the cable No. 25 of Zhaobaoshan cable-stayed bridge in China is calculated. The effects of various parameters on the estimated cable safety reliability are investigated. The results indicate that the proposed method can be used to assess the safety level of stay cables in cable-stayed bridges effectively. The Daniels' effect should be taken into account for assessment, and the probability of broken wires can be used to simulate the deterioration of stay cables in service. 展开更多
关键词 safety factor PROBABILITY EVALUATION cable-stayed bridge
在线阅读 下载PDF
Comparison of various procedures for progressive collapse analysis of cable-stayed bridges 被引量:13
5
作者 Jian-guo CAI Yi-xiang XU +2 位作者 Li-ping ZHUANG Jian FENG Jin ZHANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2012年第5期323-334,共12页
Alternate path(AP) method is the most widely used method for the progressive collapse analysis,and its application in frame structures has been well proved.However,the application of AP method for other structures,esp... Alternate path(AP) method is the most widely used method for the progressive collapse analysis,and its application in frame structures has been well proved.However,the application of AP method for other structures,especially for cable-stayed structures,should be further developed.The four analytical procedures,i.e.,linear static,nonlinear static,linear dynamic,and nonlinear dynamic were firstly improved by taking into account the initial state.Then a cable-stayed structure was studied using the four improved methods.Furthermore,the losses of both one cable and two cables were discussed.The results show that for static and dynamic analyses of the cable-stayed bridges,there is large difference between the results obtained from simulations starting with either a deformed or a nondeformed configuration at the time of cable loss.The static results are conservative in the vicinity of the ruptured cable,but the dynamic effect of the cable loss in the area farther away from the loss-cable cannot be considered.Moreover,the dynamic amplification factor of 2.0 is found to be a good estimate for static analysis procedures,since linear static and linear dynamic procedures yield approximately the same maximum vertical deflection.The results of the comprehensive evaluation of the cable failure show that the tread of the progressive failure of the cable-stayed bridges decreases when the location of the failed cables is closer to the pylon. 展开更多
关键词 Progressive failure Structural failures COLLAPSE Linear analysis Nonlinear analysis Dynamic analysis cable-stayed bridges
原文传递
Longitudinal forces of continuously welded track on high-speed railway cable-stayed bridge considering impact of adjacent bridges 被引量:33
6
作者 戴公连 闫斌 《Journal of Central South University》 SCIE EI CAS 2012年第8期2348-2353,共6页
A proven beam-track contact model was used to analyze the track-structure interaction of CWR (continuously welded track) on bridge. Considering the impact of adjacent bridges, the tower-cable-track-beam-pier-pile fini... A proven beam-track contact model was used to analyze the track-structure interaction of CWR (continuously welded track) on bridge. Considering the impact of adjacent bridges, the tower-cable-track-beam-pier-pile finite element model of the cable-stayed bridge was established. Taking a bridge group including 40-32m simply-supported beam and (32+80+112)m single-tower cable-stayed bridge and 17-32m simply-supported beam on the Kunming-Shanghai high-speed railway as an example, the characteristics of CWR longitudinal force on the cable-stayed bridge were studied. It is shown that adjacent bridges must be considered in the calculation of the track expansion force and bending force on cable-stayed bridge. When the span amount of adjacent bridges is too numerous, it can be simplified as six spans; the fixed bearing of adjacent simply-supported beams should be placed on the side near the cable-stayed bridge; the track expansion device should be set at the bridge tower to reduce the track force near the bridge abutment. 展开更多
关键词 high-speed railway continuously welded track cable-stayed bridge simply-supported beam
在线阅读 下载PDF
Ground motion spatial variability effects on seismic response control of cable-stayed bridges 被引量:13
7
作者 Shehata E. Abdel Raheem Toshiro Hayashikawa Uwe Dorka 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第1期37-49,共13页
The spatial variability of input ground motion at supporting foundations plays a key role in the structural response of cable-stayed bridges (CSBs); therefore, spatial variation effects should be included in the ana... The spatial variability of input ground motion at supporting foundations plays a key role in the structural response of cable-stayed bridges (CSBs); therefore, spatial variation effects should be included in the analysis and design of effective vibration control systems. The control of CSBs represents a challenging and unique problem, with many complexities in modeling, control design and implementation, since the control system should be designed not only to mitigate the dynamic component of the structural response but also to counteract the effects of the pseudo-static component of the response. The spatial variability effects on the feasibility and efficiency of seismic control systems for the vibration control of CSBs are investigated in this paper. The assumption of uniform earthquake motion along the entire bridge may result in quantitative and qualitative differences in seismic response as compared with those produced by uniform motion at all supports. A systematic comparison of passive and active system performance in reducing the structural responses is performed, focusing on the effect of the spatially varying earthquake ground motion on the seismic response of a benchmark CSB model with different control strategies, and demonstrates the importance of accounting for the spatial variability of excitations. 展开更多
关键词 cable-stayed bridge vibration control earthquake spatial variation seismic design semi-active control
在线阅读 下载PDF
Effects of fundamental factors on coupled vibration of wind-rail vehicle-bridge system for long-span cable-stayed bridge 被引量:11
8
作者 张明金 李永乐 汪斌 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第5期1264-1272,共9页
In a wind-vehicle-bridge(WVB) system,there are various interactions among wind,vehicle and bridge.The mechanism for coupling vibration of wind-vehicle-bridge systems is explored to demonstrate the effects of fundament... In a wind-vehicle-bridge(WVB) system,there are various interactions among wind,vehicle and bridge.The mechanism for coupling vibration of wind-vehicle-bridge systems is explored to demonstrate the effects of fundamental factors,such as mean wind,fluctuating wind,buffeting,rail irregularities,light rail vehicle vibration and bridge stiffness.A long cable-stayed bridge which carries light rail traffic is regarded as a numerical example.Firstly,a finite element model is built for the long cable-stayed bridge.The deck can generally be idealized as three-dimensional spine beam while cables are modeled as truss elements.Vehicles are modeled as mass-spring-damper systems.Rail irregularities and wind fluctuation are simulated in time domain by spectrum representation method.Then,aerodynamic loads on vehicle and bridge deck are measured by section model wind tunnel tests.Eight vertical and torsional flutter derivatives of bridge deck are identified by weighting ensemble least-square method.Finally,dynamic responses of the WVB system are analyzed in a series of cases.The results show that the accelerations of the vehicle are excited by the fluctuating wind and the track irregularity to a great extent.The transverse forces of wheel axles mainly depend on the track irregularity.The displacements of the bridge are predominantly determined by the mean wind and restricted by its stiffness.And the accelerations of the bridge are enlarged after adding the fluctuating wind. 展开更多
关键词 wind-vehicle-bridge system coupled vibration long-span cable-stayed bridge fundamental factors
在线阅读 下载PDF
Infl uence of structural parameters on dynamic characteristics and wind-induced buffeting responses of a super-long-span cable-stayed bridge 被引量:7
9
作者 Wang Hao Chen Chunchao +1 位作者 Xing Chenxi Li Aiqun 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第3期389-399,共11页
A 3D finite element (FE) model for the Sutong cable-stayed bridge (SCB) is established based on ANSYS. The dynamic characteristics of the bridge are analyzed using a subspace iteration method. Based on recorded wi... A 3D finite element (FE) model for the Sutong cable-stayed bridge (SCB) is established based on ANSYS. The dynamic characteristics of the bridge are analyzed using a subspace iteration method. Based on recorded wind data, the measured spectra expression is presented using the nonlinear least-squares regression method. Turbulent winds at the bridge site are simulated based on the spectral representation method and the FFT technique. The influence of some key structural parameters and measures on the dynamic characteristics of the bridge are investigated. These parameters include dead load intensity, as well as vertical, lateral and torsional stiffness of the steel box girder. In addition, the influence of elastic stiffness of the connection device employed between the towers and the girder on the vibration mode of the steel box girder is investigated. The analysis shows that all of the vertical, lateral and torsional buffeting displacement responses reduce gradually as the dead load intensity increases. The dynamic characteristics and the structural buffeting displacement response of the SCB are only slightly affected by the vertical and torsional stiffness of the steel box girder, and the lateral and torsional buffeting displacement responses reduce gradually as the lateral stiffness increases. These results provide a reference for dynamic analysis and design of super-long-span cable-stayed bridges. 展开更多
关键词 cable-stayed bridge dynamic characteristics finite element (FE) method wind field simulation buffetingresponse parameter effects elastic connection device
在线阅读 下载PDF
Dynamic effect of heavy-haul train on seismic response of railway cable-stayed bridge 被引量:7
10
作者 ZHU Zhi-hui GONG Wei +3 位作者 WANG Kun LIU Yu DAVIDSON Michael T JIANG Li-zhong 《Journal of Central South University》 SCIE EI CAS CSCD 2020年第7期1939-1955,共17页
This paper focuses on understanding and evaluating the dynamic effect of the heavy-haul train system on the seismic performance of a long-span railway bridge. A systematic study on the effect of heavy-haul trains on b... This paper focuses on understanding and evaluating the dynamic effect of the heavy-haul train system on the seismic performance of a long-span railway bridge. A systematic study on the effect of heavy-haul trains on bridge seismic response has been conducted, considering the influence of vehicle modeling strategies and dynamic characteristics of the seismic waves. For this purpose, the performance of a long-span cable-stayed railway bridge is assessed with stationary trains atop it, where the heavy-haul vehicles are modeled in two different ways: the multi-rigid body model with suspension system and additional mass model. Comparison of the bridge response in the presence or absence of the train system has been conducted, and the vehicle loading situation, which includes full-load and no-load, is also discussed. The result shows that during the earthquake, the peak moment of the main girder and peak stress of stay cables increase by 80% and by 40% in the presence of fully loaded heavy-haul trains, respectively. At the same time, a considerable decrease appears in the peak acceleration of the main girder. This proves the existence of the damping effect of the heavy-haul train system, and this effect is more obvious for the fully loaded vehicles. Finally, this paper proposes an efficient vehicle modeling method with 2 degrees of freedom(DOF) for simplifying the treatment of the train system in bridge seismic checking. 展开更多
关键词 train-bridge interaction heavy-haul train cable-stayed bridge EARTHQUAKE live load
在线阅读 下载PDF
Dynamic responses of cable-stayed bridges to vehicular loading including the effects of the local vibration of cables 被引量:7
11
作者 He ZHANG Xu XIE 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2011年第8期593-604,共12页
Stay cables, the primary load carrying components of cable-stayed bridges (CSBs), are characterised by high flexi-bility which increases with the span of the bridge. This makes stay cables vulnerable to local vibratio... Stay cables, the primary load carrying components of cable-stayed bridges (CSBs), are characterised by high flexi-bility which increases with the span of the bridge. This makes stay cables vulnerable to local vibrations which may have significant effects on the dynamic responses of long-span CSBs. Hence, it is essential to account for these effects in the assessment of the dynamics CSBs. In this paper, the dynamic responses of CSBs under vehicular loads are studied using the finite element method (FEM), while the local vibration of stay cables is analyzed using the substructure method. A case study of a cable-stayed steel bridge with a center span of 448 m demonstrates that stay cables undergo large displacements in the primary mode of the whole bridge although, in general, a cable’s local vibrations are not obvious. The road surface roughness has significant effects on the interaction force between the deck and vehicle but little effect on the global response of the bridge. Load impact factors of the main girder and tower are small, and the impact factors of the tension of cables are larger than those of the displacements of girders and towers. 展开更多
关键词 cable-stayed bridge(CSB) Vehicular load Local vibration of cable Impact effect
原文传递
Dynamic performance of cable-stayed bridge tower with multi-stage pendulum mass damper under wind excitations——I:Theory 被引量:4
12
作者 郭安薪 徐幼麟 李惠 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第3期295-306,共12页
In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limita... In this paper, wind-induced vibration control of a single column tower of a cable-stayed bridge with a multi- stage pendulum mass damper (MSPMD) is investigated. Special attention is given to overcoming space limitations for installing the control device in the tower and the effect of varying natural frequency of the towers during construction. First, the finite element model of the bridge during its construction and the basic equation of motion of the MSPMD are introduced. The equation of motion of the bridge with the MSPMD under along-wind excitation is then established. Finally, a numerical simulation and parametric study are conducted to assess the effectiveness of the control system for reducing the wind-induced vibration of the bridge towers during construction. The numerical simulation results show that the MSPMD is practical and effective for reducing the along-wind response of the single column tower, can be installed in a small area of the tower, and complies with the time-variant characteristics of the bridge during its entire construction stage. 展开更多
关键词 multi-stage pendulum mass damper cable-stayed bridge single column tower wind-induced vibration
在线阅读 下载PDF
Numerical calculation on solar temperature field of a cable-stayed bridge with U-shaped section on high-speed railway 被引量:3
13
作者 刘文硕 戴公连 饶少臣 《Journal of Central South University》 SCIE EI CAS 2014年第8期3345-3352,共8页
Based on transient temperature field theory of heat conduction, the solar temperature field calculation model of U-shape sectioned high-speed railway cable-stayed bridge under actions of concrete beams and ballast was... Based on transient temperature field theory of heat conduction, the solar temperature field calculation model of U-shape sectioned high-speed railway cable-stayed bridge under actions of concrete beams and ballast was established. Using parametric programming language, finite element calculation modules considering climate conditions, bridge site, structure dimension and material thermophysical properties were compiled. Six standard day cycles with the strongest yearly radiation among the bridge sites were selected for sectional solar temperature field calculation and temperature distributions under different temperature-sensitive parameters were compared. The results show that under the influence of sunshine, U-shape section of the beam shows obvious nonlinear distribution characteristics and the maximum cross-section temperature difference is more than 21℃; the ballast significantly reduces sunshine temperature difference of the beam and temperature peak of the bottom margin lags with the increase of ballast thickness; the maximum cross-section vertical temperature gradient appears in summer while large transverse temperature difference appears in winter. 展开更多
关键词 high-speed railway cable-stayed bridge U-shaped section solar temperature field thermal analysis
在线阅读 下载PDF
Dynamic analysis and modal test of long-span cable-stayed bridge based on ambient excitation 被引量:3
14
作者 陈常松 颜东煌 《Journal of Central South University of Technology》 EI 2007年第1期135-139,共5页
To study the stiffness distribution of girder and the method to identify modal parameters of cable-stayed bridge, a simplified dynamical finite element method model named three beams model was established for the gird... To study the stiffness distribution of girder and the method to identify modal parameters of cable-stayed bridge, a simplified dynamical finite element method model named three beams model was established for the girder with double ribs. Based on the simplified model four stiffness formulae were deduced according to Hamilton principle. These formulae reflect well the contribution of the flexural, shearing, free torsion and restricted torsion deformation, respectively. An identification method about modal parameters was put forward by combining method of peak value and power spectral density according to modal test under ambient excitation. The dynamic finite element method analysis and modal test were carried out in a long-span concrete cable-stayed bridge. The results show that the errors of frequencies between theoretical analysis and test results are less than 10% mostly, and the most important modal parameters for cable-stayed bridge are determined to be the longitudinal floating mode, the first vertical flexural mode and the first torsional mode, which demonstrate that the method of stiffness distribution for three beams model is accurate and method to identify modal parameters is effective under ambient excitation modal test. 展开更多
关键词 bridge engineering cable-stayed bridge dynamic finite element method ambient excitation modal test
在线阅读 下载PDF
Internal Force Distribution in Steel-Concrete Composite Structure for Pylon of Cable-Stayed Bridge 被引量:5
15
作者 蒲黔辉 白光亮 《Journal of Southwest Jiaotong University(English Edition)》 2009年第2期95-101,共7页
Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure... Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load. 展开更多
关键词 Stud connector Experimental research Steel-concrete composite structure cable-stayed bridge Internal force distribution
在线阅读 下载PDF
Spatial gust impact analysis on safety and comfort of a train crossing cable-stayed bridge combining statistical method 被引量:2
16
作者 ZHANG Yun-fei LI Li 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第8期2605-2620,共16页
In order to study the safety and the comfort of high-speed trains running on a single-tower cable-stayed bridge under spatial gust,a dynamic model of wind-train-bridge analysis model is built based on the autoregressi... In order to study the safety and the comfort of high-speed trains running on a single-tower cable-stayed bridge under spatial gust,a dynamic model of wind-train-bridge analysis model is built based on the autoregressive method,the multi-body dynamics method and the finite element method.On this basis,the influence of spatial gust model loading,the suspension parameters change,wind attack angle and speed on the train-bridge system are analyzed by combining the time/frequency domain analysis and statistical methods.The results show that the spatial gust environment is one of the most important factors affecting safety and comfort and can make the calculation result tend to be conservative and more conducive.The response changes caused by K_(py),K_(px)and K_(sx)changes are nearly linear,while Ksy shows nonlinear characteristics and the most sensitivity.Wind attack angle at 75°and 90°has the greatest influence on the vehicle-bridge system.For ride comfort index,when pre-set wind speed(α=75°)reaches 20 m/s,the vertical acceleration firstly exceeds the limit value;when wind speed(α=90°)reaches 21.5 m/s,the lateral acceleration firstly exceeds the limit value,and the ride comfort of the vehicle cannot be guaranteed.For running safety index,when pre-set wind speed(α=75°)reaches 24.6 m/s,the wheel unloading coefficient firstly exceeds the limit;when pre-set wind speed(α=90°)reaches 24.5 m/s,the derailment coefficient firstly exceeds the limit,and the running safety cannot be guaranteed.The results can provide a suitable reference for the safe and stable operation of trains on the bridge. 展开更多
关键词 wind-train-bridge dynamic system high-speed train crosswind environment single-tower cable-stayed bridge running safety running stability
在线阅读 下载PDF
Dynamic performance of cable-stayed bridge tower with multi-stage pendulum mass damper under wind excitations—Ⅱ: Experiment 被引量:2
17
作者 郭安薪 徐幼麟 李惠 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第4期417-424,共8页
The possibility of using a multi-stage pendulum mass damper (MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part I of this... The possibility of using a multi-stage pendulum mass damper (MSPMD) to control wind-induced vibration of a single column tower of a cable-stayed bridge during construction was studied theoretically in part I of this work. In this paper, the performance of the MSPMD for reducing bridge tower vibration is studied experimentally. A MSPMD model and a tower model of the bridge with geometry scaling of 1:100 were designed and manufactured. Calibration of the MSPMD model with different wire lengths is conducted to verify the analytical model of the damper. A series of tests for the uncontrolled freestanding tower, tower with cables, and tower with MSPMD model are then performed under harmonic and white noise excitations. The experimental results show that the responses of the tower model significantly decrease with the installation of the MSPMD model, which demonstrates the effectiveness of the M SPMD to mitigate the vibration of the bridge tower. 展开更多
关键词 experimental study cable-stayed bridge single column tower multi-stage pendulum mass damper vibration control
在线阅读 下载PDF
Theoretical and experimental study on shear lag effect of partially cable-stayed bridge 被引量:1
18
作者 吴高峰 徐鸿 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第8期875-877,共3页
In order to resolve the traffic congestion problem, many cable-stayed bridges are designed with a large width to span ratio. This results in significant shear lag effect to cause nonuniform stress distribution along t... In order to resolve the traffic congestion problem, many cable-stayed bridges are designed with a large width to span ratio. This results in significant shear lag effect to cause nonuniform stress distribution along the flanges of the beam of bridge. This paper reports study on the shear lag effect of the Lanzhou Xiaoxihu Yellow River Bridge. A 3D finite element model of the bridge was developed and finite element analysis (FEA) was done to obtain the theoretical results. To evaluate the theoretical results, a scaled model was made to conduct static test in laboratory. The experiment results accorded with the results obtained by FEA. It is proved that FEA is an effective method to predict shear lag effect of bridges of this type. 展开更多
关键词 cable-stayed bridge FEA EXPERIMENTAL Shear lag effect
在线阅读 下载PDF
Shake table experimental study of cable-stayed bridges with two different design strategies of H-shaped towers 被引量:1
19
作者 Xu Yan Cui Cunyu +1 位作者 Zeng Zeng Zeng Shijie 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第2期483-493,共11页
As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years... As one of the main load-carrying components of cable-stayed bridges,bridge towers are typically required to remain elastic even when subjected to severe ground motions with a 2%-3%probability of exceedance in 50 years.To fulfill this special requirement imposed by current seismic design codes,reinforcement ratios in the bridge towers have to be kept significantly higher than if limited ductility behavior of the tower is allowed.In addition,since the foundation capacity is closely related to the moment and shear capacities of the bridge tower,a large increase in bridge construction cost for elastically designed cable-stayed bridge is inevitable.To further investigate the possibility of limited ductility bridge tower design strategies,a new 1/20-scale cable-stayed bridge model with H-shaped bridge towers designed according to strong strut-weak tower column design was tested.The shake table experimental results are compared with a previous strong tower column-weak strut designed full bridge model.A comparison of the results show that ductility design with plastic hinges located on tower columns,i.e.,strong strut-weak tower column design,is another effective seismic design strategy that results in only small residual displacement at the top of the tower column,even under very severe earthquake excitations. 展开更多
关键词 cable-stayed bridge shake table experiment limited ductility design H-shaped bridge tower seismic design
在线阅读 下载PDF
GPS Dynamic Monitoring Experiment and Result Analysis of Long-Span Cable-Stayed Bridge 被引量:1
20
作者 HUANG Shengxiang WU Wentan 《Geo-Spatial Information Science》 2006年第1期1-5,共5页
For the sake of timely appraising the working con di tion of the bridge, measuring the dynamic characteristics of the bridge structur e is very important and necessary. A GPS dynamic monitoring test was carried out in... For the sake of timely appraising the working con di tion of the bridge, measuring the dynamic characteristics of the bridge structur e is very important and necessary. A GPS dynamic monitoring test was carried out in the Wuhan Baishazhou Bridge, which is one of the longest span cable-stayed bridges having been built in China. This paper introduces the experimental imple menting scheme and data processing method. The vibration characteristics of the middle span of cable-stayed bridge are availably obtained by use of the spectra l analytic approach. The measuring results are very identical to the theoretical designed values. The research demonstrates that, with GPS receiver of the high sampling rate and suitable data processing method, the vibration characteristics of the bridge structure can be determined with high accuracy. 展开更多
关键词 long-span cable-stayed bridge GPS monitoring dynamic characteristic spectral analysis
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部