期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Seismic performance and comparison of three different I beam to box column joints 被引量:3
1
作者 Z.Saneei Nia A.Mazroi +1 位作者 M.Ghassemieh H.Pezeshki 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第4期717-729,共13页
Despite the inherently advantages of the box column, finding the best option for the I beam to the box column connection is the main challenge in using the box column as a structural member for special moment frames. ... Despite the inherently advantages of the box column, finding the best option for the I beam to the box column connection is the main challenge in using the box column as a structural member for special moment frames. In this paper, the seismic performance of urtreinforced connection, weakened connection and strengthened connection was evaluated through a comprehensive experimental program. The seismic comparisons were fabricated by assessing the strength, ductility and energy dissipation in each configuration. Three full scale tests with several connections were carried out. All the specimens were subjected to cyclic loading and prior to failure by forming a plastic hinge in the beam, all the connections managed to reach an inelastic rotation of more than 6.0% rad. The experimental and analytical results showed that the seismic performance of the strengthened connection with flange and shear plates turned out to be the most effective in the beam to the box column connection. Moreover, the normalized stress distribution of the continuity plates revealed that the possibility of the weld fracture in unreinforced connection is more than other specimens. 展开更多
关键词 box column special moment frame unreinforced connection weakened connection strengthened connection seismic comparison
在线阅读 下载PDF
THE APPROXIMATE ANALYTICAL SOLUTION FOR THE BUCKLING LOADS OF A THIN-WALLED BOX COLUMN WITH VARIABLE CROSS-SECTION
2
作者 谢用九 宁钦海 陈明伦 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1998年第5期445-456,共12页
For a thin-walled box column with variable cross-section, the three governing equations for torsional-flexural buckling are ordinary differential equations of the second or fourth order with variable coefficients, so ... For a thin-walled box column with variable cross-section, the three governing equations for torsional-flexural buckling are ordinary differential equations of the second or fourth order with variable coefficients, so it is very difficult to solve them by means of an analytic method. In this paper, polynomials are used to approximate the geometric properties of cross-section and certain coefficients of the differential equations. Based on the energy principle and the Galerkin's method, the approximate formulas for calculating the flexural and torsional buckling loads of this kind of columns are developed respectively, and numerical examples are used to verify the correctness of the solutions obtained. The results calculated in this paper provide the basis for demonstrating the stability of thin-walled box columns with variable cross-section. This paper is of practical value. 展开更多
关键词 thin-walled box column with variable cross-section torsional-flexural buckling approximate solutions for buckling loads
在线阅读 下载PDF
Research and Application on Machining Accuracy Control Technology and Installation Construction Points of Steel Structure Box Column
3
作者 LIUWei 《外文科技期刊数据库(文摘版)工程技术》 2022年第3期173-178,共6页
Through a series of steel column processing control measures, such as automatic cutting and blanking, U-shaped assembly, BOX assembly, CO2 backing weld, submerged arc automatic welding, the construction accuracy of la... Through a series of steel column processing control measures, such as automatic cutting and blanking, U-shaped assembly, BOX assembly, CO2 backing weld, submerged arc automatic welding, the construction accuracy of large steel box column is improved. Through the construction accuracy control of key process of box column on-site installation, the accurate positioning and installation of steel box column is ensured. The welding deformation problem is well solved through the verification of the solid engineering construction. This experience has a great reference value for steel box column processing and construction accuracy control. 展开更多
关键词 steel structure box column welding distortion installation of steel columns accuracy control
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部