As the environmental problems become increasingly serious,distributed electrical propulsion systems with higher aerodynamic efficiency and lower pollution emission have received extensive attention in recent years.The...As the environmental problems become increasingly serious,distributed electrical propulsion systems with higher aerodynamic efficiency and lower pollution emission have received extensive attention in recent years.The distributed electrical propulsion usually employs the new aero-propulsion integrated configuration.A simulation strategy for internal and external flow coupling based on the combination of lifting line theory and body force method is proposed.The lifting line theory and body force method as source term are embedded into the Navier-Stokes formulation.The lift and drag characteristics of the aero-propulsion coupling configuration are simulated.The results indicate that the coupling configuration has the most obvious lift augmentation at 12°angle of attack,which can provide an 11.11%increase in lift for the airfoil.At 0°angle of attack,the pressure difference on the lip parts provides the thrust component,which results in a lower drag coefficient.Additionally,the failure impact of a ducted fan at the middle or edge on aerodynamics is investigated.For the two failure conditions,the lift of the coupling configuration is decreased significantly by 27.85%and 26.14%respectively,and the lip thrust is decreased by 70.74%and 56.48%respectively.展开更多
The flow over a short intake is characterised by a strong interaction with the fan, that can only be captured when the rotor blades are modelled in the numerical simulations. In this paper, we use a coupled methodolog...The flow over a short intake is characterised by a strong interaction with the fan, that can only be captured when the rotor blades are modelled in the numerical simulations. In this paper, we use a coupled methodology to derive indications about relevant geometric variables affecting the high-incidence operation of an ultra-high bypass ratio turbofan intake with a length-to-diameter ratio of 0.35. By reproducing the effect of the fan through a body force model, we carry out a parametric study of the influence of the contraction ratio and the scarf angle at take-off conditions for a grid of 28 different three-dimensional shapes. The analysis of the selected performance metrics distributions at three angles of attack of 16., 24., and 28. reveals that a contraction ratio higher than 1.20 is needed to avoid separation at high incidence. While for an attached inlet the best performance is found with a moderate scarf angle, in presence of a developed separation the distortion level reduces as the scarf decreases up to negative values. We discuss the correspondence between the distortion indexes and the flow field, highlighting the origin of the detachment for the different geometries, according to the operating condition, and analysing the fan operation in the most distorted case. Finally, we assess the influence of modelling the rotor in the simulations, showing that its suppression effect on the separation at a given incidence depends on the intake geometric features.展开更多
基金the funding support from the Taihang Laboratory,China(No.D2024-1-0201).
文摘As the environmental problems become increasingly serious,distributed electrical propulsion systems with higher aerodynamic efficiency and lower pollution emission have received extensive attention in recent years.The distributed electrical propulsion usually employs the new aero-propulsion integrated configuration.A simulation strategy for internal and external flow coupling based on the combination of lifting line theory and body force method is proposed.The lifting line theory and body force method as source term are embedded into the Navier-Stokes formulation.The lift and drag characteristics of the aero-propulsion coupling configuration are simulated.The results indicate that the coupling configuration has the most obvious lift augmentation at 12°angle of attack,which can provide an 11.11%increase in lift for the airfoil.At 0°angle of attack,the pressure difference on the lip parts provides the thrust component,which results in a lower drag coefficient.Additionally,the failure impact of a ducted fan at the middle or edge on aerodynamics is investigated.For the two failure conditions,the lift of the coupling configuration is decreased significantly by 27.85%and 26.14%respectively,and the lip thrust is decreased by 70.74%and 56.48%respectively.
文摘The flow over a short intake is characterised by a strong interaction with the fan, that can only be captured when the rotor blades are modelled in the numerical simulations. In this paper, we use a coupled methodology to derive indications about relevant geometric variables affecting the high-incidence operation of an ultra-high bypass ratio turbofan intake with a length-to-diameter ratio of 0.35. By reproducing the effect of the fan through a body force model, we carry out a parametric study of the influence of the contraction ratio and the scarf angle at take-off conditions for a grid of 28 different three-dimensional shapes. The analysis of the selected performance metrics distributions at three angles of attack of 16., 24., and 28. reveals that a contraction ratio higher than 1.20 is needed to avoid separation at high incidence. While for an attached inlet the best performance is found with a moderate scarf angle, in presence of a developed separation the distortion level reduces as the scarf decreases up to negative values. We discuss the correspondence between the distortion indexes and the flow field, highlighting the origin of the detachment for the different geometries, according to the operating condition, and analysing the fan operation in the most distorted case. Finally, we assess the influence of modelling the rotor in the simulations, showing that its suppression effect on the separation at a given incidence depends on the intake geometric features.