Estimation and correction of the optics errors in an operational storage ring is always vital to achieve the design performance. To achieve this task, the most suitable and widely used technique, called linear optics ...Estimation and correction of the optics errors in an operational storage ring is always vital to achieve the design performance. To achieve this task, the most suitable and widely used technique, called linear optics from closed orbit(LOCO) is used in almost all storage ring based synchrotron radiation sources. In this technique, based on the response matrix fit, errors in the quadrupole strengths, beam position monitor(BPM) gains, orbit corrector calibration factors etc. can be obtained. For correction of the optics, suitable changes in the quadrupole strengths can be applied through the driving currents of the quadrupole power supplies to achieve the desired optics. The LOCO code has been used at the Indus-2 storage ring for the first time. The estimation of linear beam optics errors and their correction to minimize the distortion of linear beam dynamical parameters by using the installed number of quadrupole power supplies is discussed. After the optics correction, the performance of the storage ring is improved in terms of better beam injection/accumulation, reduced beam loss during energy ramping, and improvement in beam lifetime. It is also useful in controlling the leakage in the orbit bump required for machine studies or for commissioning of new beamlines.展开更多
Indus-2 is an Indian synchrotron light source, operating at 2.5 Ge V and generating synchrotron radiation from its bending magnets. In order to provide more intense synchrotron radiation to the synchrotron users, ther...Indus-2 is an Indian synchrotron light source, operating at 2.5 Ge V and generating synchrotron radiation from its bending magnets. In order to provide more intense synchrotron radiation to the synchrotron users, there is a plan to install five insertion devices in the Indus-2 storage ring. In the first phase of installation of insertion devices, there is a proposal to install two out- vacuum pure permanent magnet linearly polarized undulators in long straight sections of the Indus-2 storage ring. The presence of the insertion devices in the ring has inevitable effects on beam parameters like betatron tune, betatron amplitude function, closed orbit, emittance, energy spread and dynamic aperture etc. In this paper, the effect of two undulators on the above mentioned parameters of the Indus-2stored electron beam at 2.5 Ge V is presented. Moreover a correction scheme for the restoration of the betatron tune and amplitude function is also presented.展开更多
In Indus-2, by optimizing the position of the magnetic elements, using the simulated annealing algorithm, at different locations in the ring with their field errors, the effects on beam parameters have been minimized....In Indus-2, by optimizing the position of the magnetic elements, using the simulated annealing algorithm, at different locations in the ring with their field errors, the effects on beam parameters have been minimized. Closed orbit distortion and beta beat are considerably reduced by optimizing the dipole and quadrupole magnets positions in the ring. For the Indus-2 storage ring, sextupole optimization gives insignificant improvement in dynamic aperture with chromaticity-correcting sextupoles. The magnets have been placed in the ring with the optimized sequence and storage of the beam has been achieved at injection energy without energizing any corrector magnets. Magnet sorting has led to the easy beam current accumulation and the measurement of parameters such as closed orbit distortion, beta function, dispersion, dynamic aperture etc.展开更多
In this paper, the genetic algorithms are applied to the optimization problem of magnet sorting in an electron storage ring, according to which the objectives are set so that the closed orbit distortion and beta beati...In this paper, the genetic algorithms are applied to the optimization problem of magnet sorting in an electron storage ring, according to which the objectives are set so that the closed orbit distortion and beta beating can be minimized and the dynamic aperture maximized. The sorting of dipole, quadrupole and sextupole magnets is optimized while the optimization results show the power of the application of genetic algorithms in magnet sorting.展开更多
文摘Estimation and correction of the optics errors in an operational storage ring is always vital to achieve the design performance. To achieve this task, the most suitable and widely used technique, called linear optics from closed orbit(LOCO) is used in almost all storage ring based synchrotron radiation sources. In this technique, based on the response matrix fit, errors in the quadrupole strengths, beam position monitor(BPM) gains, orbit corrector calibration factors etc. can be obtained. For correction of the optics, suitable changes in the quadrupole strengths can be applied through the driving currents of the quadrupole power supplies to achieve the desired optics. The LOCO code has been used at the Indus-2 storage ring for the first time. The estimation of linear beam optics errors and their correction to minimize the distortion of linear beam dynamical parameters by using the installed number of quadrupole power supplies is discussed. After the optics correction, the performance of the storage ring is improved in terms of better beam injection/accumulation, reduced beam loss during energy ramping, and improvement in beam lifetime. It is also useful in controlling the leakage in the orbit bump required for machine studies or for commissioning of new beamlines.
文摘Indus-2 is an Indian synchrotron light source, operating at 2.5 Ge V and generating synchrotron radiation from its bending magnets. In order to provide more intense synchrotron radiation to the synchrotron users, there is a plan to install five insertion devices in the Indus-2 storage ring. In the first phase of installation of insertion devices, there is a proposal to install two out- vacuum pure permanent magnet linearly polarized undulators in long straight sections of the Indus-2 storage ring. The presence of the insertion devices in the ring has inevitable effects on beam parameters like betatron tune, betatron amplitude function, closed orbit, emittance, energy spread and dynamic aperture etc. In this paper, the effect of two undulators on the above mentioned parameters of the Indus-2stored electron beam at 2.5 Ge V is presented. Moreover a correction scheme for the restoration of the betatron tune and amplitude function is also presented.
文摘In Indus-2, by optimizing the position of the magnetic elements, using the simulated annealing algorithm, at different locations in the ring with their field errors, the effects on beam parameters have been minimized. Closed orbit distortion and beta beat are considerably reduced by optimizing the dipole and quadrupole magnets positions in the ring. For the Indus-2 storage ring, sextupole optimization gives insignificant improvement in dynamic aperture with chromaticity-correcting sextupoles. The magnets have been placed in the ring with the optimized sequence and storage of the beam has been achieved at injection energy without energizing any corrector magnets. Magnet sorting has led to the easy beam current accumulation and the measurement of parameters such as closed orbit distortion, beta function, dispersion, dynamic aperture etc.
基金Supported by National Natural Science Foundation of China(10979045,11175180,11175182)
文摘In this paper, the genetic algorithms are applied to the optimization problem of magnet sorting in an electron storage ring, according to which the objectives are set so that the closed orbit distortion and beta beating can be minimized and the dynamic aperture maximized. The sorting of dipole, quadrupole and sextupole magnets is optimized while the optimization results show the power of the application of genetic algorithms in magnet sorting.