期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Benchmark Dose Estimation for Cadmium-Induced Renal Effects Based on a Large Sample Population from Five Chinese Provinces
1
作者 KE Shen KE Qin Mei +6 位作者 JIA Wen Jing CHENG Xi Yu LI Hao ZHANG Jie Ying LUO Hui Fang HE Jin Sheng CHEN Zhi Nan 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2015年第5期383-387,共5页
A survey involving 6103 participants from five Chinese provinces was conducted to evaluate the threshold value of urinary cadmium (UCd) for renal dysfunction as benchmark dose low (BMDL). The urinary N-acetyl-13-D... A survey involving 6103 participants from five Chinese provinces was conducted to evaluate the threshold value of urinary cadmium (UCd) for renal dysfunction as benchmark dose low (BMDL). The urinary N-acetyl-13-D-glucosaminidase (UNAG) was chosen as an effect biomarker. The UCd BMDLs for UNAG ranged from 2.18μg/g creatinine (cr) to 4.26μg/g cr in the populations of different provinces. The selection of the sample population and area affect the evaluation of the BMDL. The reference level of UCd for renal effects was further evaluated based on the data of all 6103 subjects. With benchmark responses (BMR) of 10%/5%, the overall UCd BMDLs for males in the total population were 3.73/2.08 μg/g cr. The BMD was slightly lower in females, thereby indicating that females may be relatively more sensitive to Cd exposure than are males. 展开更多
关键词 benchmark Dose Estimation for Cadmium-Induced Renal Effects Based on a Large sample Population from Five Chinese Provinces BMD Cd
暂未订购
Neutron leakage spectra benchmark of a spherical polyethylene sample with a ^(252)Cf fission source
2
作者 Chang-Lin Lan Kuo-Zhi Xu +9 位作者 Yu-Ting Wei Yang-Bo Nie Xiao-Dong Pan Yan-Yan Ding Shi-Yu Zhang Hao-Nan Li Bo Gao Bo Xie Xi-Chao Ruan Shi-Long Liu 《Chinese Physics C》 2026年第3期174-185,共12页
This paper presents the development and validation of China’s first benchmark measurement system for neutron leakage time-of-flight(TOF)spectra using a ^(252)Cf spontaneous fission source and spherical polyethylene s... This paper presents the development and validation of China’s first benchmark measurement system for neutron leakage time-of-flight(TOF)spectra using a ^(252)Cf spontaneous fission source and spherical polyethylene sample.EJ-309 and CLYC scintillation detectors were used for neutron detection,and a shadow cone was employed for background suppression.Notably,the SiC detector was,for the first time on this platform,applied as the start-time signal generator in TOF spectrum measurement.The TOF spectrum covering the energy range of 0.15−8.00 MeV was measured,and the results were systematically compared with evaluated data from four major nuclear libraries:ENDF/B-Ⅷ.1,JEFF-3.3,JENDL-5,and CENDL-3.2.The comparison revealed strong agreement across the full spectrum,with calculated to experimental(C/E)deviations remaining within 5%in the high-energy region and within 13%at low energies.These results verify the system’s stability and suitability for integral experiments.The established benchmark platform provides a strong technical foundation for future neutron nuclear data validation,particularly in shielding applications and the improvement of fission-spectrum nuclear databases. 展开更多
关键词 nuclear data validation ^(252)Cf spontaneous fission source polyethylene benchmark sample SiC detector nuclear data time-of-flight technique
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部