Effects of tie beam length, width and overlap stress on settlement of foundations have been investigated. In this investigation square concrete footings have been used with dimensions (B × B × d) where (d) i...Effects of tie beam length, width and overlap stress on settlement of foundations have been investigated. In this investigation square concrete footings have been used with dimensions (B × B × d) where (d) is footing depth and (B) is footing width (1, 1.5,2 m). Width of tie beam (b) has been taken equal to 0.25, 0.30, 0.40, 0.50 and 0.75 (m). Tie beam length (L) has been taken varying from B till 3B with same footing depth = 0.50 m. Effect of overlap stress on settlement as well as effect of tie beam width and length on settlement has been determined. Also, the efficiency of tie beam length and width has been obtained. An equation is presented to compute the overlap stress zone in case of existing tie beam. It is found that the settlement increases with increasing the length of tie beam which is clear after the effect of the overlap stresses zone. The width of overlap stress zone case of existing tie beam has been found to be equal to (1.6 -1.75) B. The settlement of footings decreases with increasing tie beam width. It is found that the settlement after the effect of the overlap stress zone increases with increasing the length of tie beam.展开更多
This paper presents an experimental study investigating factors influencing the effective width of steel reinforced concrete (SRC) column-steel beam joints of building in order to calculate its resisting moment.Five 1...This paper presents an experimental study investigating factors influencing the effective width of steel reinforced concrete (SRC) column-steel beam joints of building in order to calculate its resisting moment.Five 1/2 scaled interior SRC column-steel beam joint specimens were made with considering parameters such as beam flange width,beam depth and SRC column width.One directional increasing moment was applied to the joint by acting forces to each ends of beam and the structural behavior of joint was studied.And previous design method suggested by Deierlein was reviewed and a modified equation was proposed from the analysis of test result.Test result indicated that the equation to calculate the effective width in Deierlein’s design method didn’t consider effectively the influence caused by the variation of beam depth so that a modified equation was suggested and the validation of it was confirmed in this paper.展开更多
文摘Effects of tie beam length, width and overlap stress on settlement of foundations have been investigated. In this investigation square concrete footings have been used with dimensions (B × B × d) where (d) is footing depth and (B) is footing width (1, 1.5,2 m). Width of tie beam (b) has been taken equal to 0.25, 0.30, 0.40, 0.50 and 0.75 (m). Tie beam length (L) has been taken varying from B till 3B with same footing depth = 0.50 m. Effect of overlap stress on settlement as well as effect of tie beam width and length on settlement has been determined. Also, the efficiency of tie beam length and width has been obtained. An equation is presented to compute the overlap stress zone in case of existing tie beam. It is found that the settlement increases with increasing the length of tie beam which is clear after the effect of the overlap stresses zone. The width of overlap stress zone case of existing tie beam has been found to be equal to (1.6 -1.75) B. The settlement of footings decreases with increasing tie beam width. It is found that the settlement after the effect of the overlap stress zone increases with increasing the length of tie beam.
基金supported by a grant from the Academic Research Program of Chungju National University in 2011
文摘This paper presents an experimental study investigating factors influencing the effective width of steel reinforced concrete (SRC) column-steel beam joints of building in order to calculate its resisting moment.Five 1/2 scaled interior SRC column-steel beam joint specimens were made with considering parameters such as beam flange width,beam depth and SRC column width.One directional increasing moment was applied to the joint by acting forces to each ends of beam and the structural behavior of joint was studied.And previous design method suggested by Deierlein was reviewed and a modified equation was proposed from the analysis of test result.Test result indicated that the equation to calculate the effective width in Deierlein’s design method didn’t consider effectively the influence caused by the variation of beam depth so that a modified equation was suggested and the validation of it was confirmed in this paper.