期刊文献+
共找到1,038篇文章
< 1 2 52 >
每页显示 20 50 100
Readout electronics for beam monitor in the External-Target Experiment of CSR
1
作者 Jun Liu Chao-Song Gao +9 位作者 Hu-Lin Wang Zhen Wang Xiang-Ming Sun Ran Chen Fei Yan Bi-Hui You Zi-Xuan Song Cheng-Xin Zhao Guang-Ming Huang Feng Liu 《Nuclear Science and Techniques》 2025年第5期113-125,共13页
The Cooling Storage Ring(CSR)external-target experiment(CEE)will be the first large-scale nuclear physics experiment at the Heavy Ion Research Facility in Lanzhou(HIRFL).A beam monitor has been developed to monitor th... The Cooling Storage Ring(CSR)external-target experiment(CEE)will be the first large-scale nuclear physics experiment at the Heavy Ion Research Facility in Lanzhou(HIRFL).A beam monitor has been developed to monitor the beam status and to improve the reconstruction resolution of the primary vertex.Custom-designed pixel charge sensors,named TopmetalCEEv1,are employed in the detector to locate the position of each particle.Readout electronics for the beam monitor were designed,including front-end electronics utilizing the Topmetal-CEEv1 sensors,as well as a readout and control unit that communicates with the DAQ,trigger,and clock systems.A series of tests were performed to validate the functionality and performance of the system,including basic electronic verifications and responses toαparticles and heavy-ion beams.The results show that all designed functions of the readout electronics system work well,and this system could be used for beam monitoring in the CEE experiment. 展开更多
关键词 CEE beam monitor Topmetal-CEEv1 Readout electronics
在线阅读 下载PDF
Design and tests of the prototype a beam monitor of the CSR external target experiment 被引量:6
2
作者 Hu-Lin Wang Zhen Wang +21 位作者 Chao-Song Gao Jian-Wei Liao Xiang-Ming Sun Hai-Bo Yang Cheng-Xin Zhao Jun Liu Peng Ma Zi-Li Li Bi-Hui You Ping Yang Di Guo Le Xiao Dong-Liang Zhang Yue-Zhao Zhang Sheng Dong Wan-Han Feng Yu-Xin Qiao Zheng-Yu Hu Qing-Wen Ye Zeng-Tao Guo Guang-Ming Huang Feng Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第3期137-151,共15页
A prototype beam monitor was designed to provide tracking information for heavy-ion projectiles for the cool storage ring(CSR)external target experiment(CEE)at the Heavy Ion Research Facility in Lanzhou(HIRFL).High gr... A prototype beam monitor was designed to provide tracking information for heavy-ion projectiles for the cool storage ring(CSR)external target experiment(CEE)at the Heavy Ion Research Facility in Lanzhou(HIRFL).High granularity and direct charge sensing are the main features of this device.It measures the beam position in a two-dimensional(2D)plane transverse to the beam direction on an event-by-event basis.The current design consists of two field cages inside a single vessel that operates independently and has electrical drift fields in orthogonal directions.Preliminary tests of the prototype were performed using a^(241)Am a source.The results show that a spatial resolution of less than 40μm and a time resolution of less than 600 ns can be achieved. 展开更多
关键词 CEE beam monitor Heavy ion Topmetal sensor Tracking Field cage
在线阅读 下载PDF
Compact lithium-glass neutron beam monitor for SANS at CSNS 被引量:2
3
作者 Ke Zhou Jian-Rong Zhou +6 位作者 Yu-Shou Song Xiao-Juan Zhou Zhao-Yang Xie Gui-An Yang Yan-Feng Wang Yuan-Bo Chen Zhi-Jia Sun 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第9期165-170,共6页
A small-angle scattering neutron spectrometer for material research is under construction at the China Spallation Neutron Source. An intervening neutron beam monitor behind the sample is needed to measure the beam int... A small-angle scattering neutron spectrometer for material research is under construction at the China Spallation Neutron Source. An intervening neutron beam monitor behind the sample is needed to measure the beam intensity in order to reduce the measurement uncertainty caused by beam fluctuation. Considering the mobility requirement and limited space, we proposed a compact monitor using a type of lithium-glass scintillator provided by China Building Materials Academy. Its performance was studied experimentally using ^(252)Cf and ^(60)Co sources.The neutron light yield of the selected scintillator was measured to be 5:3 × 10~3 photons/neutron. The feasibility of n-gamma discrimination using the charge comparison method was verified. By using the Geant4 toolkit, themonitor was modeled with precise physical processes including neutron tracking, scintillation, and optical photon transmission. The gamma sensitivity and detection efficiency were investigated in the simulation. It was concluded that a 0.5-mm-thick lithium-glass scintillator with natural lithium is an appropriate choice to satisfy both the neutron detection efficiency and gamma elimination requirements. 展开更多
关键词 Neutron beam monitor LITHIUM GLASS ngamma DISCRIMINATION Detection efficiency
在线阅读 下载PDF
Development of heterogeneous multiprocessing digital beam position and phase monitor electronics at HIAF-iLinac
4
作者 Zhi-Xue Li Jun-Xia Wu +15 位作者 Ke-Wei Gu Fa-Fu Ni Rui-Xia Tian Guang-Yu Zhu Yong Zhang Shang-Shang Lu Li-Li Li Hong-Ming Xie Ze Du Xiao-Xuan Qiu Yuan Wei Long Jing Jia Yin Pei-Lin He Weng-Hui Li Hong-Fei Zhang 《Nuclear Science and Techniques》 2025年第4期105-118,共14页
The heavy-ion accelerator facility(HIAF)under construction in China will produce various stable and intense radioactive beams with energies ranging from MeV/u to GeV/u.The ion-linac(iLinac)accelerator,which will serve... The heavy-ion accelerator facility(HIAF)under construction in China will produce various stable and intense radioactive beams with energies ranging from MeV/u to GeV/u.The ion-linac(iLinac)accelerator,which will serve as the injector for the HIAF,is a superconducting heavy-ion accelerator containing 13 cryomodules.It will operate in either continuous wave mode or pulsed mode,with a beam current ranging from 0.01 to 1 emA.The beam position monitor(BPM)is crucial for this high-beam-power machine,which requires precise beam control and a very small beam loss of less than 1 W/m,especially inside the cryomodules of this unique beam instrument.Nearly 70 BPMs will be installed on the iLinac.New digital beam position and phase measurement(DBPPM)electronics based on a heterogeneous multiprocessing platform system-on-chip(MPSoC)has been developed to provide accurate beam trajectory and phase measurements as well as beam interlocking signals for a fast machine protection system(MPS).The DBPPM comprises an analog front-end(AFE)board in field programmable gate array(FPGA)mezzanine-connector(FMC)form factor,along with a digital signal processing board housed within a “2U 19”chassis.To mitigate radio frequency(RF)leakage effects from high-power RF systems in certain scenarios,beam signals undergo simultaneous processing at both fundamental and second-harmonic frequencies.A dynamic range from-65 dBm to 0 dBm was established to accommodate both weak beam commissioning and high-intensity operational demands.Laboratory tests demonstrated that at input power levels exceeding-45 d Bm,the phase resolution surpasses 0.05°,and the position resolution exceeds 5μm.These results align well with the stipulated measurement requirements.Moreover,the newly developed DBPPM has self-testing and self-calibration functions that are highly helpful for the systematic evaluation of numerous electronic components and fault diagnosis equipment.In addition,the DBPPM electronics implements a 2D nonlinear polynomial correction on the FPGA and can collect accurate real-time position measurements at large beam offsets.This newly developed DBPPM electronics has been applied to several Linac machines,and the results from beam measurements show high performance,good long-term stability,and high reliability.In this paper,a detailed overview of the architecture,performance,and proof-of-principle measurement of the beams is presented. 展开更多
关键词 HIAF beam position and phase monitor Digital signal processing FPGA
在线阅读 下载PDF
High-precision CSNS beam monitor system conceptual design based on SiC
5
作者 Ye He Xingchen Li +20 位作者 Zijun Xu Ming Qi Congcong Wang Chengwei Wang Hai Lu Xiaojun Nie Ruirui Fan Hantao Jing Weiming Song Keqi Wang Kai Liu Peilian Liu Hui Li Zaiyi Li Chenxi Fu Xiyuan Zhang Xiaoshen Kang Zhan Li Weiguo Lu Suyu Xiao Xin Shi 《Radiation Detection Technology and Methods》 CSCD 2024年第4期1594-1603,共10页
Purpose A high-precision beam monitor system based on silicon carbide PIN sensor is designed for the 1.6 GeV proton beam of China Spallation Neutron Source.The conceptual design of the beam monitor system is composed ... Purpose A high-precision beam monitor system based on silicon carbide PIN sensor is designed for the 1.6 GeV proton beam of China Spallation Neutron Source.The conceptual design of the beam monitor system is composed of front-end electronics with SiC PIN sensor and readout system.Method The charge collection efficiency of the SiC PIN sensor after proton radiation is studied with 80 MeV proton beam.98%charge will be collected by the SiC PIN sensor after the system running one year,which can meet requirements of beam monitoring.Research on the performance of the front-end electronics and readout system is completed for better data acquisition.The front-end electronics is studied to figure out the effect of feedback resistor.The readout system can deal with signal with sampling rate of 5 GHz,and the data acquisition rate is 1 Hz.Results The uncertainty of proton beam fluence is below 0.68%in the beam monitor system.Conclusion The results reveal that the beam monitor system can be used for the 1.6 GeV proton beam of China Spallation Neutron Source. 展开更多
关键词 beam monitor system SiC PIN Proton radiation
原文传递
Diagnostic Method for Beam Position Monitor Based on Clustering by Fast Search and Find of Density Peaks
6
作者 姜瑞涛 杨星 +1 位作者 邓又铭 冷用斌 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第3期457-462,共6页
Beam position monitors(BPMs)are important to monitor the beam moving steadily.Keeping the beam's normal motion is an important mission for Shanghai Synchrotron Radiation Facility.Effective diagnostic analysis is a... Beam position monitors(BPMs)are important to monitor the beam moving steadily.Keeping the beam's normal motion is an important mission for Shanghai Synchrotron Radiation Facility.Effective diagnostic analysis is an important way to accomplish this task.This paper develops a new method based on clustering analysis to diagnose the healthy of BPMs with basic running data,i.e.,the β oscillation of X and Y directions and noise data.The analysis results showed that all beam position monitors(140 BPMs)can be classified into three groups:normal group,worse performance group,and fault group,respectively.In addition,the abnormal BPMs(including worse performance)could be marked.The new method showed its ability to handle faulty BPMs and it could instruct daily maintenance.On the other hand,it will be a useful supplement for data analysis in accelerator physics. 展开更多
关键词 synchrotron radiation beam position monitor(BPM) βoscillation beam position monitor noise beam position monitor troubleshooting
原文传递
Neutron beam monitor based on a boron-coated GEM 被引量:6
7
作者 周健荣 孙志嘉 +7 位作者 刘贲 王艳凤 杨桂安 周良 许虹 董静 杨雷 李仪 《Chinese Physics C》 SCIE CAS CSCD 2011年第7期668-674,共7页
A new thermal neutron beam monitor with a Gas Electron Multiplier (GEM) is developed to meet the needs of the next generation of neutron facilities. A prototype chamber has been constructed with two 100 mm×100 ... A new thermal neutron beam monitor with a Gas Electron Multiplier (GEM) is developed to meet the needs of the next generation of neutron facilities. A prototype chamber has been constructed with two 100 mm×100 mm GEM foils. Enriched boron-10 is coated on one surface of the aluminum cathode plate as the neutron convertor. 96 channel pads with an area of 8 mm×8 mm each are used for fast signal readout. In order to study the basic characteristics of a boron-coated GEM, several irradiation tests were carried out with of source ^239pu and neutron source ^241Am(Be). The signal induced by the neutron source has a high signal-to-noise ratio. A clear image obtained from of source ^239pu is presented, which shows that the neutron beam monitor based on a boron-coated GEM has a good two-dimensional imaging ability. 展开更多
关键词 boron-coated GEM neutron beam monitor spallation neutron source
原文传递
Simulation study on the boron-coated GEM neutron beam monitor 被引量:3
8
作者 WANG YanFeng SUN ZhiJia +4 位作者 ZHOU JianRong YANG GuiAn XU Hong WANG Tuo CHEN YuanBo 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2013年第10期1897-1902,共6页
A Monte Carlo method of the 3D GEM simulation is introduced.The physical process of the neutron detection is described with the Geant4 code and the Garfield code.The results of the optimized electric-fields,the emitte... A Monte Carlo method of the 3D GEM simulation is introduced.The physical process of the neutron detection is described with the Geant4 code and the Garfield code.The results of the optimized electric-fields,the emitted ions spectrum,the electrons transverse diffusion and the signal width are presented.Moreover,the preliminary result with a CF-252 neutron source is reported.These are useful in designing detector structures and to provide an optimized option for the development of the boron-coated GEM neutron beam monitor. 展开更多
关键词 GEM neutron beam monitor Garfield code Geant4 code
原文传递
RESIDUAL GAS IONIZATION BEAM PROFILE MONITOR ON 40MeV H^— BEAM TRANSPORT LINE
9
作者 徐伟鹏 E.Takasaki 《Nuclear Science and Techniques》 SCIE CAS CSCD 1995年第2期75-80,共6页
The monitor is composed of a pair of electrodes,a single stage of microchannel plate,a phosphor screen,a CCD camera and a PC computer,To obtain a good uniform collecting field,forming electrodes system is used instead... The monitor is composed of a pair of electrodes,a single stage of microchannel plate,a phosphor screen,a CCD camera and a PC computer,To obtain a good uniform collecting field,forming electrodes system is used instead of that with a resistive divider,The readout system is performed by the phosphor screen and the CCD camera because the spatial resolution is not limited by the mechanical structure like the anode strip type and such video display system is very useful for beam studies and operation of the 40MeV linac,Besides,the design and test results are described in detail. 展开更多
关键词 On-line measurement systems beam monitors Hydrogen 1 minus beams
在线阅读 下载PDF
Strip line beam position monitor for HLS LINAC 被引量:4
10
作者 LI Ji-Hao SUN Bao-Gen HE Duo-Hui LU Ping WANG Yong WANG Jun-Hua JIN Kai CAO Yong ZHENG Pu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2005年第5期257-259,共3页
The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the or... The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the original interceptive fluorescent target. This paper gives out the theoretical analysis and bench test result of the strip line BPM. The BPM has a characteristic impedance of (50±5)?, a reflection coefficient of less than –4 dB, a band-width of 400 MHz, a coupling coefficient of less than -15 dB, and a sensitivity of 1.16 dB/mm. Additionally, the strip line BPM has a good linearity. 展开更多
关键词 HLS LINAC BPM 时域 频域 电极 灵敏性 直线性 加速器
在线阅读 下载PDF
GATE simulation based feasibility studies of in-beam PET monitoring in ^(12)C beam cancer therapy 被引量:2
11
作者 WU Jing LIU Yaqiang MA Tianyu WEI Qingyang WANG Shi CHENG Jianping 《Nuclear Science and Techniques》 SCIE CAS CSCD 2010年第5期275-280,共6页
In comparison with conventional radiotherapy techniques,12C beam therapy has its significant advantage in cancer treatment because the radiation dose are mostly concentrated near the Bragg peak region and damage to no... In comparison with conventional radiotherapy techniques,12C beam therapy has its significant advantage in cancer treatment because the radiation dose are mostly concentrated near the Bragg peak region and damage to normal tissues along the beam path is thus greatly reduced.In-beam PET provides a way to monitor dose distribution inside human body since several kinds of positron-emitting nuclei are produced through the interaction between 12C beam and body matters.In this work,we study the quantitative relationship between the spatial location of the Bragg peak and the spatial distribution of positrons produced by positron-emitting nuclei.Monte Carlo package GATE is used to simulate the interactions between the incident 12C beam of different energies(337.5,270.0 and 195.0 MeV/u) and various target matters(water,muscle and spine bone).Several data post-processing operations are performed on the simulated positron-emitting nuclei distribution data to mimic the impacts of positron generation and finite spatial resolution of a typical PET imaging system.Simulation results are compared to published experimental data for verification.In all the simulation cases,we find that 10C and 11C are two dominant positron-emitting nuclei,and there exists a significant correlation between the spatial distributions of deposited energy and positrons.Therefore,we conclude that it is possible to determine the location of Bragg peak with 1 mm accuracy using current PET imaging systems by detecting the falling edge of the positron distribution map in depth direction. 展开更多
关键词 放射治疗 癌症治疗 模拟 聚酯 正电子发射 Bragg峰 监测 辐射剂量
在线阅读 下载PDF
Alignment of beam position monitors in cryomodule of CADS injector Ⅱ 被引量:3
12
作者 Jian-Dong Yuan Yuan He +7 位作者 Bin Zhang Jun-Hui Zhang Jun-Xia Wu Yong Zhang Feng-Feng Wang Jun-Jie Yao Guo-Zhen Sun Yu-Qin Wan 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第6期95-100,共6页
Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in c... Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in cryogenic situations.In this paper,to check the offset from the mechanical to electrical center in low temperature(77 K),Fourier's law and finite element method are used to simulate cryo-deformation.Laser tracker and micro-alignment telescope are employed in combined BPM calibration,installation and monitoring.The calibration error is<0.02 mm,and the installation and monitoring precision are 0.06 mm and 0.01 mm,respectively.The monitored cryo-deformation agrees well with the simulation results.These indicate that the combined alignment can improve performance of the BPM system.All these guaranteed the success of running the 9.55 MeV@2.14 mA cw protons. 展开更多
关键词 beam POSITION monitorS ALIGNMENT Fourier’s LAW Cryomodule CADS ANSYS
在线阅读 下载PDF
A real-time beam loss monitoring system for storage ring of SSRF 被引量:1
13
作者 CAI Jun XU Xunjiang +6 位作者 XIA Xiaobin HOU Lei ZENG Ming WANG Jianhua WANG Guanghong LIU Xin XU Jiaqiang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2011年第1期5-8,共4页
In this paper we report the real-time beam loss monitoring (BLM) system at the storage ring of SSRF.The BLM-XS detectors and Ethernet data acquisition system are used in this system.Some applications and experiments o... In this paper we report the real-time beam loss monitoring (BLM) system at the storage ring of SSRF.The BLM-XS detectors and Ethernet data acquisition system are used in this system.Some applications and experiments of the BLM system are also presented.The BLM system provides dynamic information of beam loss for the storage ring,and is helpful to ensure the facility commissioning,investigate the problems of machine,optimize the machine parameters and further increase the beam lifetime. 展开更多
关键词 监控系统 储存环 光源 上海 亏损 实时 数据采集系统 BLM
在线阅读 下载PDF
Dual-cavity beam arrival time monitor design for the Shanghai soft X-ray FEL facility 被引量:2
14
作者 Shan-Shan Cao Ren-Xian Yuan +1 位作者 Jian Chen Yong-Bin Leng 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第5期14-21,共8页
Free electron lasers provide high-power and ultrashort pulses with extreme brightness. In order to improve a facility's capabilities and explore the possibility of performing high-resolution time-resolved experime... Free electron lasers provide high-power and ultrashort pulses with extreme brightness. In order to improve a facility's capabilities and explore the possibility of performing high-resolution time-resolved experiments, a beam arrival time resolution under 100 fs is required. In this article, a novel beam arrival time monitor(BAM)equipped with two cavities has been designed and a beam flight time measurement scheme based on the BAM prototype has been proposed to estimate phase jitter in the signal measurement system. The two BAM cavities work at different frequencies and the frequency difference is designed to be 35 MHz. Therefore, a self-mixing intermediate frequency signal can be generated using the two cavities. The measured beam flight time shows a temporal deviation of 37 fs(rms). 展开更多
关键词 beam ARRIVAL TIME monitor Dual-cavities beam flight TIME SELF-MIXING
在线阅读 下载PDF
Design and measurement of signal processing system for cavity beam position monitor 被引量:3
15
作者 WANG Baopeng LENG Yongbin +3 位作者 YU Luyang ZHOU Weimin YUAN Renxian CHEN Zhichu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第2期1-6,共6页
In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of r... In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target. 展开更多
关键词 信号处理系统 位置分辨率 在线测量 设计目标 显示器 光束 MATLAB平台 信号处理算法
在线阅读 下载PDF
Beam position monitor troubleshooting by using principal component analysis in Shanghai Synchrotron Radiation Facility 被引量:1
16
作者 陈之初 冷用斌 +2 位作者 袁任贤 阎映炳 赖龙伟 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第2期7-12,共6页
Beam position monitors(BPMs)have been widely used in all kinds of measurement systems,feedback systems and other areas in particle accelerator field these days.The malfunction of a single BPM can cause serious consequ... Beam position monitors(BPMs)have been widely used in all kinds of measurement systems,feedback systems and other areas in particle accelerator field these days.The malfunction of a single BPM can cause serious consequences such as the failure of the orbit feedback and the transverse feedback.A troubleshooting has been made to prevent the defective BPMs from affecting the accuracy and stability of the storage ring in Shanghai Synchrotron Radiation Facility(SSRF).Different types of malfunctions have been successfully identified by using the idea of principal component analysis(PCA). 展开更多
关键词 上海同步辐射装置 主成分分析法 光位置检测器 故障排除 反馈系统 粒子加速器 BPM 测量系统
在线阅读 下载PDF
Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy 被引量:9
17
作者 Rong-Cheng Han Yong-Jiang Li Yue-Hu Pu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第2期1-10,共10页
The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or p... The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems.In this study,Boag’s theory was applied to a proton pencil beam scanning system.The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area.This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency.It was determined that collection efficiency is positively correlated with applied voltage,beam size,and beam energy,but negatively correlated with beam current intensity.Additionally,it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen. 展开更多
关键词 Collection efficiency monitor ionization chamber Pencil beam scanning Proton therapy
暂未订购
Beam position monitors as precise phase pickups for beam energy measurement at the Compact Pulsed Hadron Source
18
作者 Min-Wen Wang Qing-Zi Xing +5 位作者 Shu-Xin Zheng Zhong-Ming Wang Meng-Tong Qiu Xia-Ling Guan Xue-Wu Wang Wen-Hui Huang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第2期1-9,共9页
The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ... The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value. 展开更多
关键词 beam energy Time of flight beam position monitor PHASE PICKUP
在线阅读 下载PDF
The control and monitor system for the BESⅢ ETOF/MRPC beam test
19
作者 钱森 宁哲 +10 位作者 付在伟 陈晓辉 孙勇杰 杨帅 贾茹 张家文 衡月昆 李澄 李家才 祁鸣 郑阳恒 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第1期14-18,共5页
A test system is developed for the BESIII ETOF/MRPC beam tests of data acquisition, environment monitoring and automatic control. The software framework is based on the CAMAC bus, VME bus and Serial Port,which are res... A test system is developed for the BESIII ETOF/MRPC beam tests of data acquisition, environment monitoring and automatic control. The software framework is based on the CAMAC bus, VME bus and Serial Port,which are responsible for communications with the detectors. The monitor system works well in the beam test. 展开更多
关键词 监控系统 MRPC 试验控制 PC梁 CAMAC总线 测试系统 VME总线 数据采集
在线阅读 下载PDF
Beam Characteristics at Low Dose Monitor Unit Settings for Vero4DRT
20
作者 Hideharu Miura Shuichi Ozawa +3 位作者 Shintaro Tsuda Masahiro Hayata Kiyoshi Yamada Yasushi Nagata 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期284-289,共6页
The stability of delivery of low monitor unit (MU) setting is important especially for step-and-shoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off acco... The stability of delivery of low monitor unit (MU) setting is important especially for step-and-shoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off according to the number of the segments. This study evaluates the dose linearity and profile flatness/symmetry under low MU settings for Vero4DRT, a new linear-accelerator based irradiation system that currently implements step-and-shoot IMRT. To evaluate the dose linearity and flatness/symmetry, the point doses and beam profiles were measured as functions of MU and dose rates. The accuracy of dose delivery depended on the dose rate. Under all dose rates, the dose was linear within 1% above 5 MU and within 2% above 3 MU. The beam symmetry was degraded in-line compared with crossline, although both profiles were symmetric within 2% at all dose settings. The profile flatness was also within 2% above 5 MU at any dose rate and showed no significant variation among the low MU settings. To ensure stable beam delivery without increasing the treatment time of Vero4DRT, we recommend a delivery of 5 MU per segment at a dose rate of 500 MU/min. 展开更多
关键词 Vero4DRT Step-and-Shoot IMRT Low monitor UNIT beam Characteristic
暂未订购
上一页 1 2 52 下一页 到第
使用帮助 返回顶部