期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Design of Automatic Batch Calibration and Correction System for IMU
1
作者 Lihua Zhu Qifan Yun +1 位作者 Zhiqiang Wu Cheire Cheng 《Computers, Materials & Continua》 SCIE EI 2022年第4期1489-1501,共13页
Thanks to its light weight,low power consumption,and low price,the inertial measurement units(IMUs)have been widely used in civil and military applications such as autopilot,robotics,and tactical weapons.The calibrati... Thanks to its light weight,low power consumption,and low price,the inertial measurement units(IMUs)have been widely used in civil and military applications such as autopilot,robotics,and tactical weapons.The calibration is an essential procedure before the IMU is put in use,which is generally used to estimate the error parameters such as the bias,installation error,scale factor of the IMU.Currently,the manual one-by-one calibration is still the mostly used manner,which is low in efficiency,time-consuming,and easy to introduce mis-operation.Aiming at this issue,this paper designs an automatic batch calibration method for a set of IMUs.The designed automatic calibration master controller can control the turntable and the data acquisition system at the same time.Each data acquisition front-end can complete data acquisition of eight IMUs one time.And various scenarios of experimental tests have been carried out to validate the proposed design,such as the multi-position tests,the rate tests and swaying tests.The results illustrate the reliability of each function module and the feasibility automatic batch calibration.Compared with the traditional calibration method,the proposed design can reduce errors caused by the manual calibration and greatly improve the efficiency of IMU calibration. 展开更多
关键词 MEMS inertial measurement unit batch calibration automatic calibration
在线阅读 下载PDF
Simultaneous determination of naphazoline and pyridoxine in eye drops using excitation–emission matrix fluorescence coupled with second-order calibration method based on alternating trilinear decomposition algorithm 被引量:2
2
作者 Hui Xia Hai-Long Wu +3 位作者 Hui-Wen Gu Xiao-Li Yin Huan Fang Ru-Qin Yu 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第12期1446-1449,共4页
A novel method is developed for the direct determination of naphazoline hydrochloride(NAP) and pyridoxine hydrochloride(VB6) in commercial eye drops. By using excitation–emission matrix(EEM)fluorescence coupled... A novel method is developed for the direct determination of naphazoline hydrochloride(NAP) and pyridoxine hydrochloride(VB6) in commercial eye drops. By using excitation–emission matrix(EEM)fluorescence coupled with second-order calibration method based on the alternating trilinear decomposition(ATLD) algorithm, the proposed approach can achieve quantitative analysis successfully even in the presence of unknown and uncalibrated interferences. The method shows good linearity for NAP and VB6 with correlation coefficients greater than 0.99. The results were in good agreement with the labeled contents. To further confirm the feasibility and reliability of the proposed method, the same batch samples were analyzed by multiple reaction monitoring(MRM) based on LC–MS/MS method.T-test demonstrated that there are no significant differences between the prediction results of the two methods. The satisfactory results obtained in this work indicate that the use of the second-order calibration method coupled with the EEM is a promising tool for industrial quality control and pharmaceutical analysis due to its advantages of high sensitivity, low-cost and simple implementation. 展开更多
关键词 calibration excitation satisfactory labeled interpolation pharmaceutical normalized alternating batch scatter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部