Currently, the high-speed serial fiber-optic ring net communication is a main method for performing the distributed control network topology and control mode. Because of a network transmission delay inherent in the to...Currently, the high-speed serial fiber-optic ring net communication is a main method for performing the distributed control network topology and control mode. Because of a network transmission delay inherent in the topology, synchronization between nodes has become a critical issue which needs to be studied. The existing synchronization methods largely depend on the complex communication protocol. Therefore, this paper has proposed a method of automatic measurement and compensation of synchronization delay, and analyzed its operating principle and implementation procedure in detail. The results obtained from the experiments prove the proposed method to be correct, effective and practicable.展开更多
Generator synchronization is an important and frequent operation in rural small hydropower station. In order to ensure that generator can be paralleled in the grid automatically, efficiently, and stably in the rural s...Generator synchronization is an important and frequent operation in rural small hydropower station. In order to ensure that generator can be paralleled in the grid automatically, efficiently, and stably in the rural small hydropower station whose parallel in operation still needs to be accomplished manually. This paper described an automatic quasi-synchronizing device, based on 89C52 Single-chip Microcomputer (SCM). Its hardware includes three modules and its software is structuralized. The device structure is simple, and its reliability is high and the maintenance is easy. Besides, convenient Human Machine Interface (HMI) makes the parameter setting simple and flexible展开更多
The synchronizer is a key component of automatic mechanical transmission(AMT)equipped in electric vehicles,but the inertial lock-ring synchronizer(ILRS)commonly used there is not suitable especially for pure electric ...The synchronizer is a key component of automatic mechanical transmission(AMT)equipped in electric vehicles,but the inertial lock-ring synchronizer(ILRS)commonly used there is not suitable especially for pure electric vehicles without a clutch because of big shift impact.To make the shifting process rapid and smooth,a new synchronizer named pressure-controllable friction ring synchronizer(PCFRS)was designed.Initially,the inevitable shortcoming of ILRS was verified by simulation and test.Furthermore,the mechanical characteristics and advantages of the new synchronizer over ILRS were analyzed.Then,the formulations describing the dynamic transmission based on the working mechanism of the PCFRS were established.Finally,the shifting simulation results with PCFRS and ILRS based on the same operating conditions were compared and analyzed.The research shows that the PCFRS can meet the main shifting evaluation index of an AMT without complex control methods,as well as it takes only 0.2406 s to finish the comfortable and zero-speed-difference shifting.The shifting quality of PCFRS is better than that of the ILRS.It lays a foundation for using the new synchronizer as a part of clutchless AMTs equipped in pure electric vehicles.展开更多
Wavelet forced de-noising algorithm is suitable for denoising of unsteady drilling fluid pulse signal, including baseline drift rectification and two-stage de-noising processing of frame synchronization signal and ins...Wavelet forced de-noising algorithm is suitable for denoising of unsteady drilling fluid pulse signal, including baseline drift rectification and two-stage de-noising processing of frame synchronization signal and instruction signal. Two-stage de-noising processing can reduce the impact of baseline drift and determine automatic peak detection threshold range for signal recognition by distinguishing different features of frame synchronization pulse and instruction pulse. Rising and falling edge relative protruding threshold is defined for peak detection in signal recognition, which can make full use of the degree of the signal peak change and detect peaks flexibly with rising and falling edge relative protruding threshold combination. A synchronous decoding method was designed to reduce position uncertainty of the frame synchronization pulse and eliminate the accumulative error of time base drift, which determines the first instruction pulse position according to position of the frame synchronization pulse and decodes subsequent instruction pulse by taking current instruction pulse as new bit synchronization pulse. Special tool software was developed to tune algorithm parameters, which has a decoding success rate of about 95% for the universal coded signals. For the special coded signals with check byte, decoding success rate using the automatic threshold adjustment algorithm is as high as 99%.展开更多
NTP is nowadays the most widely used distributed network time protocol, which aims at synchronizing the clocks of computers in a network and keeping the accuracy and validation of the time information which is transmi...NTP is nowadays the most widely used distributed network time protocol, which aims at synchronizing the clocks of computers in a network and keeping the accuracy and validation of the time information which is transmitted in the network. Without automatic configuration mechanism, the stability and flexibility of the synchronization network built upon NTP protocol are not satisfying. P2P’s resource discovery mechanism is used to look for time sources in a synchronization network, and according to the network environment and node’s quality, the synchronization network is constructed dynamically.展开更多
In this paper, with the non-salient pole permanent magnet linear synchronous motor (PMLSM)being cited, by using Fourier transform method and "slot-by-slot", "pole -by-pole" current approach, a 3D e...In this paper, with the non-salient pole permanent magnet linear synchronous motor (PMLSM)being cited, by using Fourier transform method and "slot-by-slot", "pole -by-pole" current approach, a 3D electromagnetic field model of PMLSM is established. Special attention is paid to its structure and the influence of longitudinal and transverse end effect. The distribution of electromagnetic field of PMLSM can be obtained directly and promptly by using FFT algorithm. It can also be used for the analysis of other LSM.展开更多
Through analyzing the special starting process and the factors which affect the starting torque of the low-speed synchronous motor, a testing method of the starting torque is proposed, and the defects of the existing ...Through analyzing the special starting process and the factors which affect the starting torque of the low-speed synchronous motor, a testing method of the starting torque is proposed, and the defects of the existing hand-test method is analyzed. Moreover, an automatic testing apparatus of this special kind of motors is introduced.展开更多
Reliable connection of turbine generators in complex main wiring structures to the power grid through a plurality of switches is a new key problem,referred to as multipoint automatic synchronization(MPAS),in automatic...Reliable connection of turbine generators in complex main wiring structures to the power grid through a plurality of switches is a new key problem,referred to as multipoint automatic synchronization(MPAS),in automatic control systems(ACS).In this paper,different methods of voltage-frequency and phase-difference control are analyzed,and a control methodology based on active frequency tracking(AFT)is presented.Through the establishment of the multi-point automatic synchronization model and the analysis of the governor transfer function with this control method,the important control parameters and automatic process control sequence are summarized.The correctness and effectiveness of the designed methodology are inspected through on-site testing,and the importance of the function and selection of parameters are also explored.展开更多
为适应大容量同步发电机组并网点母线电压波动增加对自动电压调节器(automatic voltage regulator,AVR)系统响应能力的更高要求,提出一种基于含探索网络的双延迟深度确定性策略梯度(twin delayed deep deterministic policy gradient wi...为适应大容量同步发电机组并网点母线电压波动增加对自动电压调节器(automatic voltage regulator,AVR)系统响应能力的更高要求,提出一种基于含探索网络的双延迟深度确定性策略梯度(twin delayed deep deterministic policy gradient with Explorer network,TD3EN)算法的同步发电机励磁电压控制方法。首先,通过传递函数对同步发电机励磁调压子系统进行建模;然后建立TD3EN算法探索网络、动作网络和评价网络,并设置相应参数;接着利用TD3EN算法训练智能体,通过探索网络探索动作空间,并根据评价网络更新动作网络参数,使其为AVR提供控制信号;将训练完成的智能体接入AVR系统,实现对发电机机端电压的控制。仿真结果表明,所提方法提高了AVR系统响应调节指令和应对电压暂降的能力。展开更多
As synchronous generators(SGs)are gradually displaced by renewable energy sources(RESs),the frequency stability of power systems deteriorates because RESs,represented by utility-scale solar and wind power sources,do n...As synchronous generators(SGs)are gradually displaced by renewable energy sources(RESs),the frequency stability of power systems deteriorates because RESs,represented by utility-scale solar and wind power sources,do not provide the inertial response,primary frequency response,secondary frequency response,and tertiary frequency regulation.As a result,the remaining SGs may not be sufficient to maintain the power balance and frequency stability.The concept and control strategies of virtual synchronous generators(VSGs)enable the inverter-based wind and solar power sources to emulate the outer characteristics of traditional SGs and participate in the active power and frequency control of power systems.This paper focuses on the automatic generation control(AGC)with virtual synchronous renewables(VSRs).First,the VSR strategy that enables the RESs to participate in AGC is introduced.Second,based on the interval representation of uncertainty,the output of RES is transformed into two portions,i.e.,the dispatchable portion and the stochastic portion.In the dispatchable portion,the RESs can participate in AGC jointly with SGs.Accordingly,a security-constrained economic dispatch(SCED)model is built considering the RESs operating in VSR mode.Third,the solution strategy that employs the slack variables to acquire deterministic constraints is introduced.Finally,the proposed SCED model is solved based on the 6-bus and 39-bus systems.The results show that,compared with the maximum power point tracking(MPPT)mode,VSRs can participate in the active power and frequency control jointly with SGs,increase the maximum penetration level of RESs,and decrease the operating cost.展开更多
文摘Currently, the high-speed serial fiber-optic ring net communication is a main method for performing the distributed control network topology and control mode. Because of a network transmission delay inherent in the topology, synchronization between nodes has become a critical issue which needs to be studied. The existing synchronization methods largely depend on the complex communication protocol. Therefore, this paper has proposed a method of automatic measurement and compensation of synchronization delay, and analyzed its operating principle and implementation procedure in detail. The results obtained from the experiments prove the proposed method to be correct, effective and practicable.
文摘Generator synchronization is an important and frequent operation in rural small hydropower station. In order to ensure that generator can be paralleled in the grid automatically, efficiently, and stably in the rural small hydropower station whose parallel in operation still needs to be accomplished manually. This paper described an automatic quasi-synchronizing device, based on 89C52 Single-chip Microcomputer (SCM). Its hardware includes three modules and its software is structuralized. The device structure is simple, and its reliability is high and the maintenance is easy. Besides, convenient Human Machine Interface (HMI) makes the parameter setting simple and flexible
基金Supported by National Natural Science Foundation of China(Grant No.51775478)Natural Science Foundation of Hebei Province(Grant Nos.E2020203078,E2020203174)+1 种基金Open Project of State Key Laboratory of Mechanical Behavior and System Safety of Traffic Engineering Structures(Grant No.KF2021-11)Graduate Innovation Funding Project of Hebei Province(Grant No.CXZZSS2021063)。
文摘The synchronizer is a key component of automatic mechanical transmission(AMT)equipped in electric vehicles,but the inertial lock-ring synchronizer(ILRS)commonly used there is not suitable especially for pure electric vehicles without a clutch because of big shift impact.To make the shifting process rapid and smooth,a new synchronizer named pressure-controllable friction ring synchronizer(PCFRS)was designed.Initially,the inevitable shortcoming of ILRS was verified by simulation and test.Furthermore,the mechanical characteristics and advantages of the new synchronizer over ILRS were analyzed.Then,the formulations describing the dynamic transmission based on the working mechanism of the PCFRS were established.Finally,the shifting simulation results with PCFRS and ILRS based on the same operating conditions were compared and analyzed.The research shows that the PCFRS can meet the main shifting evaluation index of an AMT without complex control methods,as well as it takes only 0.2406 s to finish the comfortable and zero-speed-difference shifting.The shifting quality of PCFRS is better than that of the ILRS.It lays a foundation for using the new synchronizer as a part of clutchless AMTs equipped in pure electric vehicles.
基金Supported by the China National Science and Technology Major Project(2016ZX05020005-001)
文摘Wavelet forced de-noising algorithm is suitable for denoising of unsteady drilling fluid pulse signal, including baseline drift rectification and two-stage de-noising processing of frame synchronization signal and instruction signal. Two-stage de-noising processing can reduce the impact of baseline drift and determine automatic peak detection threshold range for signal recognition by distinguishing different features of frame synchronization pulse and instruction pulse. Rising and falling edge relative protruding threshold is defined for peak detection in signal recognition, which can make full use of the degree of the signal peak change and detect peaks flexibly with rising and falling edge relative protruding threshold combination. A synchronous decoding method was designed to reduce position uncertainty of the frame synchronization pulse and eliminate the accumulative error of time base drift, which determines the first instruction pulse position according to position of the frame synchronization pulse and decodes subsequent instruction pulse by taking current instruction pulse as new bit synchronization pulse. Special tool software was developed to tune algorithm parameters, which has a decoding success rate of about 95% for the universal coded signals. For the special coded signals with check byte, decoding success rate using the automatic threshold adjustment algorithm is as high as 99%.
文摘NTP is nowadays the most widely used distributed network time protocol, which aims at synchronizing the clocks of computers in a network and keeping the accuracy and validation of the time information which is transmitted in the network. Without automatic configuration mechanism, the stability and flexibility of the synchronization network built upon NTP protocol are not satisfying. P2P’s resource discovery mechanism is used to look for time sources in a synchronization network, and according to the network environment and node’s quality, the synchronization network is constructed dynamically.
文摘In this paper, with the non-salient pole permanent magnet linear synchronous motor (PMLSM)being cited, by using Fourier transform method and "slot-by-slot", "pole -by-pole" current approach, a 3D electromagnetic field model of PMLSM is established. Special attention is paid to its structure and the influence of longitudinal and transverse end effect. The distribution of electromagnetic field of PMLSM can be obtained directly and promptly by using FFT algorithm. It can also be used for the analysis of other LSM.
文摘Through analyzing the special starting process and the factors which affect the starting torque of the low-speed synchronous motor, a testing method of the starting torque is proposed, and the defects of the existing hand-test method is analyzed. Moreover, an automatic testing apparatus of this special kind of motors is introduced.
文摘Reliable connection of turbine generators in complex main wiring structures to the power grid through a plurality of switches is a new key problem,referred to as multipoint automatic synchronization(MPAS),in automatic control systems(ACS).In this paper,different methods of voltage-frequency and phase-difference control are analyzed,and a control methodology based on active frequency tracking(AFT)is presented.Through the establishment of the multi-point automatic synchronization model and the analysis of the governor transfer function with this control method,the important control parameters and automatic process control sequence are summarized.The correctness and effectiveness of the designed methodology are inspected through on-site testing,and the importance of the function and selection of parameters are also explored.
文摘为适应大容量同步发电机组并网点母线电压波动增加对自动电压调节器(automatic voltage regulator,AVR)系统响应能力的更高要求,提出一种基于含探索网络的双延迟深度确定性策略梯度(twin delayed deep deterministic policy gradient with Explorer network,TD3EN)算法的同步发电机励磁电压控制方法。首先,通过传递函数对同步发电机励磁调压子系统进行建模;然后建立TD3EN算法探索网络、动作网络和评价网络,并设置相应参数;接着利用TD3EN算法训练智能体,通过探索网络探索动作空间,并根据评价网络更新动作网络参数,使其为AVR提供控制信号;将训练完成的智能体接入AVR系统,实现对发电机机端电压的控制。仿真结果表明,所提方法提高了AVR系统响应调节指令和应对电压暂降的能力。
基金supported by the Research and Application of Key Technologies of Flexible Power Supply System Under Various Emergency Scenarios(No.5442PD210001)。
文摘As synchronous generators(SGs)are gradually displaced by renewable energy sources(RESs),the frequency stability of power systems deteriorates because RESs,represented by utility-scale solar and wind power sources,do not provide the inertial response,primary frequency response,secondary frequency response,and tertiary frequency regulation.As a result,the remaining SGs may not be sufficient to maintain the power balance and frequency stability.The concept and control strategies of virtual synchronous generators(VSGs)enable the inverter-based wind and solar power sources to emulate the outer characteristics of traditional SGs and participate in the active power and frequency control of power systems.This paper focuses on the automatic generation control(AGC)with virtual synchronous renewables(VSRs).First,the VSR strategy that enables the RESs to participate in AGC is introduced.Second,based on the interval representation of uncertainty,the output of RES is transformed into two portions,i.e.,the dispatchable portion and the stochastic portion.In the dispatchable portion,the RESs can participate in AGC jointly with SGs.Accordingly,a security-constrained economic dispatch(SCED)model is built considering the RESs operating in VSR mode.Third,the solution strategy that employs the slack variables to acquire deterministic constraints is introduced.Finally,the proposed SCED model is solved based on the 6-bus and 39-bus systems.The results show that,compared with the maximum power point tracking(MPPT)mode,VSRs can participate in the active power and frequency control jointly with SGs,increase the maximum penetration level of RESs,and decrease the operating cost.