The insertion loss (IL) of a T-type attenuator is theoretically analyzed. A T-type RF ( radio frequency) CMOS ( complementary metal-oxide-semiconductor ) attenuator is designed as an on-off keying(OOK) modulat...The insertion loss (IL) of a T-type attenuator is theoretically analyzed. A T-type RF ( radio frequency) CMOS ( complementary metal-oxide-semiconductor ) attenuator is designed as an on-off keying(OOK) modulator in a time-hopping ultra wide-band (TH-UWB)communication with a carrier frequency of 4 GHz. In the topology of the OOK modulator circuit, there are three parts, an oscillator with an oscillating frequency of 4 GHz, a T-type attenuator constructed by RF CMOS transistors, and an output impedance matching network with a L-type LC structure. The modulator is controlled by a time-hopping pulse position modulation(TH-PPM) signal. The envelope of the modulated signal varies with the amplitude of the controlling signal. Meanwhile, an output matching network is also designed to match a 50 Ω load. In 0. 18 μm RF CMOS technology, a modulator is designed and simulated. The implemented modulator chip has 65 mV of the output amplitude at a 50 fl load from a 1.8 V supply, and the return loss ( S11 ) at the output port is less than - 10 dB. The chip size is 0. 7 mm × 0. 8 mm, and the power consumption is 12. 3 mW.展开更多
In this study,polyacrylic acid(PAA)films were employed as a model system,and a series of PAA films with tunable water wettability was systematically prepared by varying molecular weight and curing temperature.Using at...In this study,polyacrylic acid(PAA)films were employed as a model system,and a series of PAA films with tunable water wettability was systematically prepared by varying molecular weight and curing temperature.Using attenuated total reflectance Fourier-transform infrared spectroscopy(ATR-FTIR),the molecular configurations of surface carboxyl groups(COOH),free carboxyl(COOH_(f))and hydrogen-bonded carboxyl(COOH_(HB),were directly correlated with the polar component of surface energy(γ^(s,p)).By decomposing theγ^(s,p)values of the PAA thin films as a sum of the contributions of COOH_(f)and COOH_(H B),the intrinsic polar component of surface energy of COOH_(H B)(γ_(H B)^(s,p*))was quantified for the first time as 8.34 mN/m,significantly lower than that of COOH_(f)(γ_(f)^(s,p*)=34 mN/m).This result highlights that hydrogen bonding markedly reduces theγ^(s,p),providing a rational explanation for the relatively large water contact angle observed on PAA thin films.Furthermore,it establishes a thermodynamic basis for estimating the fraction of surface COOH_(H B)groups(f H B)from wettability measurements.Further extension of the model to carboxyl-terminated self-assembled monolayers(COOH-SAMs)revealed that surface COOH density(ΣCOOH)critically regulates wetting behavior:whenΣCOOH ranges from 4.30 to 5.25 nm^(-2),COOH groups predominantly exist in a free state and facilitate effective hydration layers,thereby promoting superhydrophilicity.Overall,this study not only establishes a unified thermodynamic framework linking surface COOH configurations to macroscopic wettability,but also validates its universality by extending it to COOH-SAMs systems,thereby providing a unified theoretical framework for the controllable design of hydrophilicity in various COOH-functionalized surfaces.展开更多
Artificial intelligence(AI)is revolutionizing medical imaging,particularly in chronic liver diseases assessment.AI technologies,including machine learning and deep learning,are increasingly integrated with multiparame...Artificial intelligence(AI)is revolutionizing medical imaging,particularly in chronic liver diseases assessment.AI technologies,including machine learning and deep learning,are increasingly integrated with multiparametric ultrasound(US)techniques to provide more accurate,objective,and non-invasive evaluations of liver fibrosis and steatosis.Analyzing large datasets from US images,AI enhances diagnostic precision,enabling better quantification of liver stiffness and fat content,which are essential for diagnosing and staging liver fibrosis and steatosis.Combining advanced US modalities,such as elastography and doppler imaging with AI,has demonstrated improved sensitivity in identifying different stages of liver disease and distinguishing various degrees of steatotic liver.These advancements also contribute to greater reproducibility and reduced operator dependency,addressing some of the limitations of traditional methods.The clinical implications of AI in liver disease are vast,ranging from early detection to predicting disease progression and evaluating treatment response.Despite these promising developments,challenges such as the need for large-scale datasets,algorithm transparency,and clinical validation remain.The aim of this review is to explore the current applications and future potential of AI in liver fibrosis and steatosis assessment using multiparametric US,highlighting the technological advances and clinical relevance of this emerging field.展开更多
Although traditional gamma-gamma density(GGD)logging technology is widely utilized,its potential environmental risks have prompted the development of more environmentally friendly neutron-gamma density(NGD)logging tec...Although traditional gamma-gamma density(GGD)logging technology is widely utilized,its potential environmental risks have prompted the development of more environmentally friendly neutron-gamma density(NGD)logging technology.However,NGD measurements are influenced by both neutron and gamma radiations.In the logging environment,variations in the formation composition indicate different elemental compositions,which affect the neutron-gamma reaction cross-sections and gamma generation.Compared to traditional gamma sources such as Cs-137,these changes significantly affect the generation and transport of neutron-induced inelastic gamma rays and hinder accurate measurements.To address this,a novel method is proposed that incorporates the mass attenuation coefficient function to account for the effects of various lithologies and pore contents on gamma-ray attenuation,thereby achieving more accurate density measurements by clarifying the transport processes of inelastic gamma rays with varying energies and spatial distributions in varied logging environments.The proposed method avoids the complex correction of neutron transport and is verified through Monte Carlo simulations for its applicability across various lithologies and pore contents,demonstrating absolute density errors that are less than 0.02 g/cm^(3)in clean formations and indicating good accuracy.This study clarifies the NGD mechanism and provides theoretical guidance for the application of NGD logging methods.Further studies will be conducted on extreme environmental conditions and tool calibration.展开更多
Hydraulic pumps are a positive displacement pump whose working principle causes inherent output flow pulsation.Flow pulsation produces pressure pulsation when encountering liquid resistance.Pressure pulsation spreads ...Hydraulic pumps are a positive displacement pump whose working principle causes inherent output flow pulsation.Flow pulsation produces pressure pulsation when encountering liquid resistance.Pressure pulsation spreads in the pipeline and causes vibration,noise,damage,and even pipeline rupture and major safety accidents.With the development of airborne hydraulic systems with high pressure,power,and flow rate,the hazards of vibration and noise caused by pressure pulsation are also amplified,severely restricting the application and development of hydraulic systems.In this review paper,the mechanism,harm,and suppression method of pressure pulsation in hydraulic systems are analyzed.Then,the classification and characteristics of pulsation attenuators according to different working principles are described.Furthermore,the critical technology of simulation design,matching method with airborne piston pumps,and preliminary design method of pulsation attenuators are proposed.Finally,the development trend of pulsation attenuators is prospected.This paper provides a reference for the research and application of pressure pulsation attenuators.展开更多
The power consumption of a variable optical attenuator(VOA) array based on a silica planar lightwave circuit was investigated. The thermal field profile of the device was optimized using the finite-element analysis....The power consumption of a variable optical attenuator(VOA) array based on a silica planar lightwave circuit was investigated. The thermal field profile of the device was optimized using the finite-element analysis. The simulation results showed that the power consumption reduces as the depth of the heat-insulating grooves is deeper, the up-cladding is thinner,the down-cladding is thicker, and the width of the cladding ridge is narrower. The materials component and thickness of the electrodes were also optimized to guarantee the driving voltage under 5 V. The power consumption was successfully reduced to as low as 155 mW at an attenuation of 30 dB in the experiment.展开更多
文摘The insertion loss (IL) of a T-type attenuator is theoretically analyzed. A T-type RF ( radio frequency) CMOS ( complementary metal-oxide-semiconductor ) attenuator is designed as an on-off keying(OOK) modulator in a time-hopping ultra wide-band (TH-UWB)communication with a carrier frequency of 4 GHz. In the topology of the OOK modulator circuit, there are three parts, an oscillator with an oscillating frequency of 4 GHz, a T-type attenuator constructed by RF CMOS transistors, and an output impedance matching network with a L-type LC structure. The modulator is controlled by a time-hopping pulse position modulation(TH-PPM) signal. The envelope of the modulated signal varies with the amplitude of the controlling signal. Meanwhile, an output matching network is also designed to match a 50 Ω load. In 0. 18 μm RF CMOS technology, a modulator is designed and simulated. The implemented modulator chip has 65 mV of the output amplitude at a 50 fl load from a 1.8 V supply, and the return loss ( S11 ) at the output port is less than - 10 dB. The chip size is 0. 7 mm × 0. 8 mm, and the power consumption is 12. 3 mW.
文摘In this study,polyacrylic acid(PAA)films were employed as a model system,and a series of PAA films with tunable water wettability was systematically prepared by varying molecular weight and curing temperature.Using attenuated total reflectance Fourier-transform infrared spectroscopy(ATR-FTIR),the molecular configurations of surface carboxyl groups(COOH),free carboxyl(COOH_(f))and hydrogen-bonded carboxyl(COOH_(HB),were directly correlated with the polar component of surface energy(γ^(s,p)).By decomposing theγ^(s,p)values of the PAA thin films as a sum of the contributions of COOH_(f)and COOH_(H B),the intrinsic polar component of surface energy of COOH_(H B)(γ_(H B)^(s,p*))was quantified for the first time as 8.34 mN/m,significantly lower than that of COOH_(f)(γ_(f)^(s,p*)=34 mN/m).This result highlights that hydrogen bonding markedly reduces theγ^(s,p),providing a rational explanation for the relatively large water contact angle observed on PAA thin films.Furthermore,it establishes a thermodynamic basis for estimating the fraction of surface COOH_(H B)groups(f H B)from wettability measurements.Further extension of the model to carboxyl-terminated self-assembled monolayers(COOH-SAMs)revealed that surface COOH density(ΣCOOH)critically regulates wetting behavior:whenΣCOOH ranges from 4.30 to 5.25 nm^(-2),COOH groups predominantly exist in a free state and facilitate effective hydration layers,thereby promoting superhydrophilicity.Overall,this study not only establishes a unified thermodynamic framework linking surface COOH configurations to macroscopic wettability,but also validates its universality by extending it to COOH-SAMs systems,thereby providing a unified theoretical framework for the controllable design of hydrophilicity in various COOH-functionalized surfaces.
文摘Artificial intelligence(AI)is revolutionizing medical imaging,particularly in chronic liver diseases assessment.AI technologies,including machine learning and deep learning,are increasingly integrated with multiparametric ultrasound(US)techniques to provide more accurate,objective,and non-invasive evaluations of liver fibrosis and steatosis.Analyzing large datasets from US images,AI enhances diagnostic precision,enabling better quantification of liver stiffness and fat content,which are essential for diagnosing and staging liver fibrosis and steatosis.Combining advanced US modalities,such as elastography and doppler imaging with AI,has demonstrated improved sensitivity in identifying different stages of liver disease and distinguishing various degrees of steatotic liver.These advancements also contribute to greater reproducibility and reduced operator dependency,addressing some of the limitations of traditional methods.The clinical implications of AI in liver disease are vast,ranging from early detection to predicting disease progression and evaluating treatment response.Despite these promising developments,challenges such as the need for large-scale datasets,algorithm transparency,and clinical validation remain.The aim of this review is to explore the current applications and future potential of AI in liver fibrosis and steatosis assessment using multiparametric US,highlighting the technological advances and clinical relevance of this emerging field.
基金supported by the National Natural Science Foundation of China(U23B20151 and 52171253).
文摘Although traditional gamma-gamma density(GGD)logging technology is widely utilized,its potential environmental risks have prompted the development of more environmentally friendly neutron-gamma density(NGD)logging technology.However,NGD measurements are influenced by both neutron and gamma radiations.In the logging environment,variations in the formation composition indicate different elemental compositions,which affect the neutron-gamma reaction cross-sections and gamma generation.Compared to traditional gamma sources such as Cs-137,these changes significantly affect the generation and transport of neutron-induced inelastic gamma rays and hinder accurate measurements.To address this,a novel method is proposed that incorporates the mass attenuation coefficient function to account for the effects of various lithologies and pore contents on gamma-ray attenuation,thereby achieving more accurate density measurements by clarifying the transport processes of inelastic gamma rays with varying energies and spatial distributions in varied logging environments.The proposed method avoids the complex correction of neutron transport and is verified through Monte Carlo simulations for its applicability across various lithologies and pore contents,demonstrating absolute density errors that are less than 0.02 g/cm^(3)in clean formations and indicating good accuracy.This study clarifies the NGD mechanism and provides theoretical guidance for the application of NGD logging methods.Further studies will be conducted on extreme environmental conditions and tool calibration.
基金Supprted by National Natural Science Foundation of China(Grant No.51775013)。
文摘Hydraulic pumps are a positive displacement pump whose working principle causes inherent output flow pulsation.Flow pulsation produces pressure pulsation when encountering liquid resistance.Pressure pulsation spreads in the pipeline and causes vibration,noise,damage,and even pipeline rupture and major safety accidents.With the development of airborne hydraulic systems with high pressure,power,and flow rate,the hazards of vibration and noise caused by pressure pulsation are also amplified,severely restricting the application and development of hydraulic systems.In this review paper,the mechanism,harm,and suppression method of pressure pulsation in hydraulic systems are analyzed.Then,the classification and characteristics of pulsation attenuators according to different working principles are described.Furthermore,the critical technology of simulation design,matching method with airborne piston pumps,and preliminary design method of pulsation attenuators are proposed.Finally,the development trend of pulsation attenuators is prospected.This paper provides a reference for the research and application of pressure pulsation attenuators.
基金Project supported by the National High Technology Research and Development Program of China(Grant No.2015AA016902)the National Nature Science Foundation of China(Grant Nos.61435013,61405188,and 61627820)
文摘The power consumption of a variable optical attenuator(VOA) array based on a silica planar lightwave circuit was investigated. The thermal field profile of the device was optimized using the finite-element analysis. The simulation results showed that the power consumption reduces as the depth of the heat-insulating grooves is deeper, the up-cladding is thinner,the down-cladding is thicker, and the width of the cladding ridge is narrower. The materials component and thickness of the electrodes were also optimized to guarantee the driving voltage under 5 V. The power consumption was successfully reduced to as low as 155 mW at an attenuation of 30 dB in the experiment.