This paper presents an investigation on a voltage and frequency controller (VFC), which functions as an improved elec-tronic load controller (IELC) for parallel operated isolated asynchronous generators (IAGs) in an a...This paper presents an investigation on a voltage and frequency controller (VFC), which functions as an improved elec-tronic load controller (IELC) for parallel operated isolated asynchronous generators (IAGs) in an autonomous hydro power generation system. In such type of hydro scheme whole generating system is isolated from the grid and supply electricity to the remote communities. The single point operation of these generators is realized, in such a manner that excitation capacitors, speeds, load, voltage, currents of generators remain constant under various operating conditions. The proposed controller consists of a 3-leg IGBT (Insulated Gate Bipolar Transistor) based voltage source converter (VSC) and a DC chopper with an auxiliary load at the DC bus of the VSC. The IELC controls the reactive and active powers simultaneously for controlling the voltage and frequency under varying consumer loads. Along with voltage and frequency control through single point operation of IAGs driven by uncontrolled pico hydro turbines, the IELC meets the power quality standard an IEEE-519 and it keeps the total harmonic distortion (THD) of the terminal voltage and currents within the limit of 5%. Here the proposed electrical system along with its controller is modeled in MATLAB along with Simulink and PSB (Power System Block-set) toolboxes. Simulation results are presented to demonstrate the capability of proposed controller for an isolated generating system.展开更多
This paper investigates the function of doubly-fed asynchronous machine(DASM)with emphasis placed on its ability to the stabilization of the power system including wind generators.P(active power)and Q(reactive power)c...This paper investigates the function of doubly-fed asynchronous machine(DASM)with emphasis placed on its ability to the stabilization of the power system including wind generators.P(active power)and Q(reactive power)compensation from DASM can be regulated independently through secondary-excitation controlling.Simulation results by power system computer aided design(PSCAD)show that DASM can restore the wind-generator system to a normal operating condition rapidly even following severe transmission-line failures.Comparison studies have also been performed between wind turbine pitch control and proposed method.展开更多
This paper proposes a tube-based method for the asynchronous observation problem of discrete-time switched linear systems in the presence of amplitude-bounded disturbances.Sufficient stability conditions of the nomina...This paper proposes a tube-based method for the asynchronous observation problem of discrete-time switched linear systems in the presence of amplitude-bounded disturbances.Sufficient stability conditions of the nominal observer error system under mode-dependent persistent dwell-time(MPDT)switching are first established. Taking the disturbances into account, a novel asynchronous MPDT robust positive invariant(RPI) set and an asynchronous MPDT generalized RPI(GRPI)set are determined for the difference system between the nominal and disturbed observer error systems. Further, the global uniform asymptotical stability of the observer error system is established in the sense of converging to the asynchronous MPDT GRPI set, i.e., the cross section of the tube of the observer error system. Finally, the proposed results are validated on a space robot manipulator example.展开更多
In this paper modelling and analysis in autonomous mode of dual three-phase induction generator (DTPIG) with a new algorithm have been done. We develop the steady state model of a dual three-phase self-excited inducti...In this paper modelling and analysis in autonomous mode of dual three-phase induction generator (DTPIG) with a new algorithm have been done. We develop the steady state model of a dual three-phase self-excited induction generator for stand-alone renewable generation dispensing with the segregating real and imaginary components of the complex impedance of the induction generator. The obtained admittance yields the adequate magnetizing reactance and the frequency. These two key parameters are then used to compute the self-excitation process requirements in terms of the prime mover speed, the capacitance and the load impedance on the one hand and to predict the generator steady state performance parameters on the other. Steady state performances and characteristics of different configurations are clearly examined and compared. The analytical results are found to be in good agreement with experimental results.展开更多
对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1...对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1~1.25)Xd;在P-Q坐标与R-X坐标的转换公式中,U值应由"失磁保护动作滞后于低励限制线(UEL)"原则来确定,不应主观选择0.95UN。展开更多
In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for ...In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for wind farms, is excited on the rotor circuit by a slip-frequency current injected to the rotor, from an exciter mounted on the same shaft of the machine. The resulting rotating magnetic field rotates at synchronous speed;as such the generated power has a constant frequency independent of the shaft speed. Effects of the excitation voltage magnitude and phase angle on the active and reactive power are studied, when the machine runs at constant speed. It has been shown that by controlling the excitation voltage magnitude and phase angle would control the mode of operation of the machine;motor mode or generator mode. Furthermore, the effects of the shaft speed on the active and reactive power at constant excitation voltage magnitude and constant phase angle are also investigated.展开更多
This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the hig...This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the high voltage circuit breaker during its close-open operating cycle. Using real time measurements of currents/voltages and angles during the close-opening cycle of high voltage generator circuit breaker and the impact of the dc component of current in context of interrupting large magnitude of current from the circuit breaker. In addition, the paper describes a study case model and the results of simulations performed using the software EMTP-ATP of an actual incident that occurred during the inadvertent synchronization of a large 339 MW, 24 kV generator to the grid.展开更多
In order to enhance the stability of single-phase microgrid,virtual synchronous generator(VSG)control method is investigated in this paper.Its electromagnetic model and electromechanical model are established to illus...In order to enhance the stability of single-phase microgrid,virtual synchronous generator(VSG)control method is investigated in this paper.Its electromagnetic model and electromechanical model are established to illustrate the performance of VSG.Considering the 2 nd fluctuation of fundamental-frequency in the output power,an instantaneous power calculation strategy is proposed based on the intrinsic frequency of single-phase VSG.Besides,a virtual power calculation method is presented to achieve islanded/grid-connected seamless transition.Stability analysis and comparison simulation results demonstrate the correctness of the presented power calculation method.At last,the effectiveness of the proposed approach is verified by comparison experiments of islanded/gridconnected operations in a 500 VA single-phase inverter.展开更多
针对现有配电网有源电压消弧方法未充分考虑线路电压降落以及分布式电源接入的影响,发生单相接地故障时无法保证故障点电压为0,存在无法可靠消弧的问题,提出了一种考虑分布式电源接入的配电网有源电压消弧技术。首先,在接入分布式电源...针对现有配电网有源电压消弧方法未充分考虑线路电压降落以及分布式电源接入的影响,发生单相接地故障时无法保证故障点电压为0,存在无法可靠消弧的问题,提出了一种考虑分布式电源接入的配电网有源电压消弧技术。首先,在接入分布式电源的基础上,考虑线路的电压降落,推导消弧电压理论计算公式,提出改进有源电压消弧方法。其次,提出一种基于馈线终端设备(feeder terminal unit, FTU)量测数据的数据驱动测距方法,能够在故障发生后准确计算出故障距离,为消弧线圈的控制提供数据。最后,通过仿真证明所提方法相较于传统有源电压消弧方法,能够更好地控制故障点电压为0。展开更多
文摘This paper presents an investigation on a voltage and frequency controller (VFC), which functions as an improved elec-tronic load controller (IELC) for parallel operated isolated asynchronous generators (IAGs) in an autonomous hydro power generation system. In such type of hydro scheme whole generating system is isolated from the grid and supply electricity to the remote communities. The single point operation of these generators is realized, in such a manner that excitation capacitors, speeds, load, voltage, currents of generators remain constant under various operating conditions. The proposed controller consists of a 3-leg IGBT (Insulated Gate Bipolar Transistor) based voltage source converter (VSC) and a DC chopper with an auxiliary load at the DC bus of the VSC. The IELC controls the reactive and active powers simultaneously for controlling the voltage and frequency under varying consumer loads. Along with voltage and frequency control through single point operation of IAGs driven by uncontrolled pico hydro turbines, the IELC meets the power quality standard an IEEE-519 and it keeps the total harmonic distortion (THD) of the terminal voltage and currents within the limit of 5%. Here the proposed electrical system along with its controller is modeled in MATLAB along with Simulink and PSB (Power System Block-set) toolboxes. Simulation results are presented to demonstrate the capability of proposed controller for an isolated generating system.
文摘This paper investigates the function of doubly-fed asynchronous machine(DASM)with emphasis placed on its ability to the stabilization of the power system including wind generators.P(active power)and Q(reactive power)compensation from DASM can be regulated independently through secondary-excitation controlling.Simulation results by power system computer aided design(PSCAD)show that DASM can restore the wind-generator system to a normal operating condition rapidly even following severe transmission-line failures.Comparison studies have also been performed between wind turbine pitch control and proposed method.
基金supported in part by the National Defense Basic Scientific Research Program of China(JCKY2018603C015)Cultivation Plan of Major Research Program of Harbin Institute of Technology(ZDXMPY20180101)
文摘This paper proposes a tube-based method for the asynchronous observation problem of discrete-time switched linear systems in the presence of amplitude-bounded disturbances.Sufficient stability conditions of the nominal observer error system under mode-dependent persistent dwell-time(MPDT)switching are first established. Taking the disturbances into account, a novel asynchronous MPDT robust positive invariant(RPI) set and an asynchronous MPDT generalized RPI(GRPI)set are determined for the difference system between the nominal and disturbed observer error systems. Further, the global uniform asymptotical stability of the observer error system is established in the sense of converging to the asynchronous MPDT GRPI set, i.e., the cross section of the tube of the observer error system. Finally, the proposed results are validated on a space robot manipulator example.
文摘In this paper modelling and analysis in autonomous mode of dual three-phase induction generator (DTPIG) with a new algorithm have been done. We develop the steady state model of a dual three-phase self-excited induction generator for stand-alone renewable generation dispensing with the segregating real and imaginary components of the complex impedance of the induction generator. The obtained admittance yields the adequate magnetizing reactance and the frequency. These two key parameters are then used to compute the self-excitation process requirements in terms of the prime mover speed, the capacitance and the load impedance on the one hand and to predict the generator steady state performance parameters on the other. Steady state performances and characteristics of different configurations are clearly examined and compared. The analytical results are found to be in good agreement with experimental results.
文摘对2007年版《IEEE Guide for AC Generator Protection》中失磁保护定值整定的几个问题提出不同意见。明确指出:发电机失磁故障必有滑差(s),其平均异步阻抗Xd(js)Xd(s=0),失磁保护中的阻抗元件下端定值为-Xd,已有足够余度,不应该是-(1.1~1.25)Xd;在P-Q坐标与R-X坐标的转换公式中,U值应由"失磁保护动作滞后于低励限制线(UEL)"原则来确定,不应主观选择0.95UN。
文摘In this paper, we present the steady state analysis of a double-fed induction generator (DFIG) adopted for wind power generation. The three-phase induction machine connected to the network, to work as a generator for wind farms, is excited on the rotor circuit by a slip-frequency current injected to the rotor, from an exciter mounted on the same shaft of the machine. The resulting rotating magnetic field rotates at synchronous speed;as such the generated power has a constant frequency independent of the shaft speed. Effects of the excitation voltage magnitude and phase angle on the active and reactive power are studied, when the machine runs at constant speed. It has been shown that by controlling the excitation voltage magnitude and phase angle would control the mode of operation of the machine;motor mode or generator mode. Furthermore, the effects of the shaft speed on the active and reactive power at constant excitation voltage magnitude and constant phase angle are also investigated.
文摘This paper analyses the synchronization problem of a generator onto power system without satisfying synchronization condition. The main focus of the paper is on the impact of the dc component of the current in the high voltage circuit breaker during its close-open operating cycle. Using real time measurements of currents/voltages and angles during the close-opening cycle of high voltage generator circuit breaker and the impact of the dc component of current in context of interrupting large magnitude of current from the circuit breaker. In addition, the paper describes a study case model and the results of simulations performed using the software EMTP-ATP of an actual incident that occurred during the inadvertent synchronization of a large 339 MW, 24 kV generator to the grid.
基金supported by the National Basic Research Program of China(973 Program)(No.2013CB02708201)
文摘In order to enhance the stability of single-phase microgrid,virtual synchronous generator(VSG)control method is investigated in this paper.Its electromagnetic model and electromechanical model are established to illustrate the performance of VSG.Considering the 2 nd fluctuation of fundamental-frequency in the output power,an instantaneous power calculation strategy is proposed based on the intrinsic frequency of single-phase VSG.Besides,a virtual power calculation method is presented to achieve islanded/grid-connected seamless transition.Stability analysis and comparison simulation results demonstrate the correctness of the presented power calculation method.At last,the effectiveness of the proposed approach is verified by comparison experiments of islanded/gridconnected operations in a 500 VA single-phase inverter.
文摘针对现有配电网有源电压消弧方法未充分考虑线路电压降落以及分布式电源接入的影响,发生单相接地故障时无法保证故障点电压为0,存在无法可靠消弧的问题,提出了一种考虑分布式电源接入的配电网有源电压消弧技术。首先,在接入分布式电源的基础上,考虑线路的电压降落,推导消弧电压理论计算公式,提出改进有源电压消弧方法。其次,提出一种基于馈线终端设备(feeder terminal unit, FTU)量测数据的数据驱动测距方法,能够在故障发生后准确计算出故障距离,为消弧线圈的控制提供数据。最后,通过仿真证明所提方法相较于传统有源电压消弧方法,能够更好地控制故障点电压为0。