期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
On the behaviour of artificial head transfer system applied to acoustic evaluation researches for halls
1
作者 XU Yong WANG Binglin(School of Architecture. Tsinghua University. Beijing 100084) 《Chinese Journal of Acoustics》 1993年第3期235-244,共10页
The author has made tests for an artificial head transfer system which is modelled on a Chinese male on its main physical behaviour such as frequency responses, frequency response differences between the front and the... The author has made tests for an artificial head transfer system which is modelled on a Chinese male on its main physical behaviour such as frequency responses, frequency response differences between the front and the rear incidences, as will as on its important hearing behaviour such as localization, the perception of distance and room dimensions. The results verify that this kind of artificial head transfer system can be used as one of effective tools of acoustic evaluation researches for halls. 展开更多
关键词 Acoustic evaluation artificial head Hall acoustics.
原文传递
The Effect of Total Hip Replacement and Artificial Femoral Head Replacement in the Treatment of Elderly Femoral Neck Fractures
2
作者 KANG Changzhou 《外文科技期刊数据库(文摘版)医药卫生》 2020年第2期070-072,共5页
Objective: to analyze the effect of total hip replacement and artificial femoral head replacement in the treatment of elderly femoral neck fracture. Methods: Fifty cases of elderly femoral neck fracture from January 2... Objective: to analyze the effect of total hip replacement and artificial femoral head replacement in the treatment of elderly femoral neck fracture. Methods: Fifty cases of elderly femoral neck fracture from January 2018 to January 2019 in our hospital were selected. Patients were randomly divided into two groups with 25 cases in each group by random number table. Patients in the femoral head group were treated with artificial femoral head replacement, while patients in the total hip group were treated with total hip replacement. The drainage volume, bleeding, total operation time, evaluation scores of QOL scale before and after treatment, Harris hip joint status score and complication rate were compared between the two groups. Results: the operation time, bleeding and drainage volume of the total hip group were higher than those of the femoral head group, P < 0.05. There was no significant difference in complications between the two groups (P > 0.05). After treatment, evaluation scores of QOL scale and Harris hip joint status score of the patients were higher than those of the femoral head group, P > 0.05. Conclusion: comparing total hip replacement and artificial femoral head replacement in the treatment of elderly femoral neck fracture, the trauma of artificial femoral head replacement is relatively simple and less bleeding, but in the long term, total hip replacement can improve the hip joint function and quality of life of patients better. 展开更多
关键词 total hip replacement artificial femoral head replacement elderly femoral neck fracture EFFECT
暂未订购
A Sound Quality Objective Evaluation Method Based on Auditory Peripheral Simulation Model 被引量:1
3
作者 Yinhan Gao~1,Jun Xie~2,Jie Liang~1,Xin Chang~3,Baojun Wu~2 1.Experimental Centre of Testing Science,Jilin University,Changchun 130022,P.R.China 2.College of Instrumentation & Electrical Engineering,Jilin University,Changchun 130061,P.R.China 3.Laboratory of Applications and Computations in Electromagnetics and Optics,Department of Electrical Engineering, University of Washington,WA 98195-2500,USA 《Journal of Bionic Engineering》 SCIE EI CSCD 2010年第2期199-208,共10页
Based on auditory peripheral simulation model, a new Sound Quality Objective Evaluation (SQOE) method is presented,which can be used to model and analyze the impacts of head, shoulder and other parts of human body on ... Based on auditory peripheral simulation model, a new Sound Quality Objective Evaluation (SQOE) method is presented,which can be used to model and analyze the impacts of head, shoulder and other parts of human body on sound wave trans-mission.This method employs the artificial head technique, in which the head related transfer function was taken into account tothe outer ear simulation phase.First, a bionic artificial head was designed as the outer ear model with considering the outersound field in view of theory and physical explanations.Then the auditory peripheral simulation model was built, which mimicsthe physiological functions of the human hearing, simulating the acoustic signal transfer process and conversion mechanismsfrom the free field to the peripheral auditory system.Finally, performance comparison was made between the proposed SQOEmethod and ArtemiS software, and the verifications of subjective and objective related analysis were made.Results show thatthe proposed method was economical, simple, and with good evaluation quality. 展开更多
关键词 sound quality objective evaluation auditory peripheral simulation model artificial head head related transfer function
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部