Deep brain stimulation(DBS),including optical stimulation and electrical stimulation,has been demonstrated considerable value in exploring pathological brain activity and developing treatments for neural disorders.Adv...Deep brain stimulation(DBS),including optical stimulation and electrical stimulation,has been demonstrated considerable value in exploring pathological brain activity and developing treatments for neural disorders.Advances in DBS microsystems based on implantable microelectrode array(MEA)probes have opened up new opportunities for closed-loop DBS(CL-DBS)in situ.This technology can be used to detect damaged brain circuits and test the therapeutic potential for modulating the output of these circuits in a variety of diseases simultaneously.Despite the success and rapid utilization of MEA probe-based CL-DBS microsystems,key challenges,including excessive wired communication,need to be urgently resolved.In this review,we considered recent advances in MEA probe-based wireless CL-DBS microsystems and outlined the major issues and promising prospects in this field.This technology has the potential to offer novel therapeutic options for psychiatric disorders in the future.展开更多
A neuronal signal detecting circuit and a neuronal signal stimulating circuit designed for a monolithic integrated MEA(micro-electrode array) system are described. As a basic cell of the circuits, an OPA( operation...A neuronal signal detecting circuit and a neuronal signal stimulating circuit designed for a monolithic integrated MEA(micro-electrode array) system are described. As a basic cell of the circuits, an OPA( operational amplifier) is designed with low power, low noise, small size and high gain. The detecting circuit has a chip area of 290 μm × 400 μm, a power dissipation of 2.02 mW, an equivalent input noise of 17.72 nV/ Hz, a gain of 60. 5 dB, and an output voltage from - 2. 48 to + 2. 5 V. The stimulating circuit has a chip area of 130 μm × 290 μm, a power dissipation of 740 μW, and an output voltage from - 2. 5 to 2. 04 V. The parameters show that two circuits are suitable for a monolithic integrated MEA system. The detecting circuit and MEA have been fabricated. The test results show that the detecting circuit works well.展开更多
An investigation was made into the argon plasma jet that expanded in a low-pressure vacuum chamber. The spatial distributions of the parameters of the plasma jet with different supplied powers were measured using a te...An investigation was made into the argon plasma jet that expanded in a low-pressure vacuum chamber. The spatial distributions of the parameters of the plasma jet with different supplied powers were measured using a ten-channel Langmuir probe array. The chemical species in the plasma jet were identified by emission spectroscopy. The electron excitation temperatures at two positions, 10 cm and 50 cm downstream from the nozzle exit were calculated, respectively, by the Boltzmann plot method.展开更多
In this article, the design idea of a 57-pin Langmuir probe array is presented, together with some experimental results. The manufacture technique of the probe array is discussed. Two-dimensional distributions of the ...In this article, the design idea of a 57-pin Langmuir probe array is presented, together with some experimental results. The manufacture technique of the probe array is discussed. Two-dimensional distributions of the plasma density, the floating potential and their fluctuations in the poloidal cross section are obtained. The blobs, which move radially and poloidally, cause great particle and energy transport. The charge neutralization by the poloidal movement of particles greatly decreases the vertical electric field in the helimak plasma. This leads to a confinement time which is two orders of magnitude larger than the theoretical prediction.展开更多
A novel electromagnetic probe array(EMPA) diagnostic, which consists of a magnetic probe array and an electrostatic probe array, has recently been developed on EAST. The EMPA is fixed near the first wall at horizontal...A novel electromagnetic probe array(EMPA) diagnostic, which consists of a magnetic probe array and an electrostatic probe array, has recently been developed on EAST. The EMPA is fixed near the first wall at horizontal port P. The magnetic probe array of the EMPA consists of 24 identical magnetic probes, each of them capable of measuring toroidal, poloidal and radial magnetic fluctuations simultaneously, providing additional toroidal magnetic fluctuation measurements compared with the regular magnetic probes on EAST. With a higher sampling rate and self-resonant frequency, the EMPA magnetic probes can provide higher frequency magnetic fluctuation measurements. The magnetic probe array of the EMPA is composed of two parallel layers of magnetic probes with a radial distance of 63 mm, and each layer of magnetic probes is arranged in four poloidal rows and three toroidal columns. The compact arrangement of the EMPA magnetic probe array largely improves the toroidal mode number measurement ability from-8≤ n≤ 8 to-112≤ n≤ 112, and also improves the high poloidal wave number measurement ability of magnetic fluctuations compared with the regular high frequency magnetic probes on EAST. The electrostatic probe array of the EMPA consists of two sets of four-tip probes and a single-tip probe array with three poloidal rows and four toroidal columns. It complements the electrostatic parameter measurements behind the main limiter and near the first wall in EAST. The engineering details of the EMPA diagnostic, including the mechanical system, the electrical system, the acquisition and control system, and the effective area calibration, are presented. The preliminary applications of the EMPA in L-mode and H-mode discharges on EAST have demonstrated that the EMPA works well for providing information on the magnetic and electrostatic fluctuations and can contribute to deeper physical analysis in future EAST experiments.展开更多
The accurate knowledge of the thrust vector eccentricity and beam divergence characteristics of Hall thrusters are of significant engineering value for the beneficial integration and successful application of Hall thr...The accurate knowledge of the thrust vector eccentricity and beam divergence characteristics of Hall thrusters are of significant engineering value for the beneficial integration and successful application of Hall thrusters on spacecraft.For the characteristics of the plume bipolar diffusion due to the annular discharge channel of the Hall thruster,a Gaussian-fitted method for thrust vector deviation angle and beam divergence of Hall thrusters based on dual Faraday probe array planes was proposed in respect of the Hall thruster beam characteristics.The results show that the ratios of the deviation between the maximum and minimum values of the beam divergence angle and the thrust vector eccentricity angle using a Gaussian fit to the optimized Faraday probe dual plane to the mean value are 1.4%and 11.5%,respectively.The optimized thrust vector eccentricity angle obtained has been substantially improved,by approximately 20%.The beam divergence angle calculated using a Gaussian fitting to the optimized Faraday probe dual plane is approximately identical to the non-optimized one.The beam divergence and thrust vector eccentricity angles for different anode mass flow rates were obtained by averaging the beam divergence and thrust vector eccentricity angles calculated by the dual-plane,Gaussian-fitted ion current density method for different cross-sections.The study not only allows for an immediate and effective tool for determining the design of thrust vector adjustment mechanisms of spacecraft with different power Hall thrusters but also for characterizing the 3D spatial distribution of the Hall thruster plume.展开更多
The working principle of the pipeline intelligent pig and the structure of ultrasonic probe array used to detect defects in oil/gas pipeline are introduced. The effects of the array' s radial position in pipe on defe...The working principle of the pipeline intelligent pig and the structure of ultrasonic probe array used to detect defects in oil/gas pipeline are introduced. The effects of the array' s radial position in pipe on defect resolution are analyzed. The causes leading to radial positioning error are investigated. An algo- rithm for the radial self-positioning is presented. The experimental results show that the radial self-positioning algorithm can eliminate the array' s space position error effectively and improve the defect resolution.展开更多
A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair ...A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.展开更多
A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC...A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC) imaging is proposed to detect corrosion. The testresults show that this system has the advantage of fast scanning speed, different imaging mode andquantitative detection, it has a broad application in the aviation nondestructive testing.展开更多
Qualitative and quantitative analysis of trace heavy metals in aqueous environment are rapidly assuming significance along with the rapid development of industry.In this paper,gold microelectrode array(MEA)plated with...Qualitative and quantitative analysis of trace heavy metals in aqueous environment are rapidly assuming significance along with the rapid development of industry.In this paper,gold microelectrode array(MEA)plated with mercury film was used for simultaneous voltammetric detection of zinc,cadmium,lead and copper ions in water.The electrochemical behavior and the actual surface area of the MEA were investigated by cyclic voltammetry in K_(3)[Fe(CN)_(6)].Electrochemical impedance spectrum(EIS)was utilized to examine the deposition of mercury on the electrode surface.Based on anodic stripping voltammetry,mercury filmAu MEA was applied to the detection of heavy metals in artificial analyte,where good calibrate linearity was obtained for cadmium,lead and copper ions,but with zinc exhibiting poor linearity.展开更多
A manual inspection of large-diameter tubular joints is difficult. As a result a scanner with three degrees of freedom ( DOFs) was developed based on the scanning principle of ultrasonic phased array. The weld traci...A manual inspection of large-diameter tubular joints is difficult. As a result a scanner with three degrees of freedom ( DOFs) was developed based on the scanning principle of ultrasonic phased array. The weld tracing is realized by a 2DOF motion of scanner. The pose of ultrasonic probe is controlled by the third one. The control strategy is put forward based on a programmable multi-axis controller. Four kinds of scanning modes can be implemented simultaneously employing this ultrasonic inspection system. Experiments on reference blocks of tubular joints reveal that the automatic ultrasonic phased array inspection system has the same inspection accuracy as a manual ultrasonic inspection. This system is superior to the manual ultrasonic system in terms of reliability and repeatability. The artificial dejects of weld at tubular joint can be detected accurately with the presented inspection system.展开更多
We have develoPed a simPle and economical method f0r Chlamydia trachomatisdetecting, called microtiter plate hybridization (PCR-MPH), which may replace stan-dard PCR. This method is similar to that of an ELISA. Brithe...We have develoPed a simPle and economical method f0r Chlamydia trachomatisdetecting, called microtiter plate hybridization (PCR-MPH), which may replace stan-dard PCR. This method is similar to that of an ELISA. Brithe, the PCR productslabeled at the 5'termini with biotin were hybridized with probes immobilized on a mi-crotiter well, and the bound PCR products were detected by streptavidin-c0njugatedenzymes followed by color development. Two inprovements have been made in immobi-lizing the probe to the microtiter wells, in terms of increasing both immobility and hy-bridization deciency. One is that singleustranded (ss )DNA, without the complemen-tary strand, is used. The other is that instead of a single copy, a tandem array of theprobe is used for immobilization and hybridization. Using of ssDNA containing abouta 5O-rePeat array of a relevant sequence as an immobilized probe, the sensitivity in-creased 1O-fold over that of a single oligonucleotide unit. We also found that the hy-brldizatlon condltions such as time, temPerature, and solution composition could be simplthed. The advantages of this microtiter plate-hybridization method for routinepathogens detecting are a short time assay, easy processing of large numbers of sansples, and the potential for automation.展开更多
The gut microbiota and the associated metabolism play a pivotal role in maintaining human health,yet their assessment is challenging due to their inherent diversity,variety,and complexity.Herein,we developed a multich...The gut microbiota and the associated metabolism play a pivotal role in maintaining human health,yet their assessment is challenging due to their inherent diversity,variety,and complexity.Herein,we developed a multichannel sensor array based on a single fluorescent probe,allowing for rapid and robust profiling gut microbiota and their key metabolites including cysteine(Cys),glutathione(GSH),and homocysteine(Hcy).The assay leverages the single fluorescent probe that is with multiple binding sites and the cross-reactive sensing principle to specifically recognize different biological thiols.By analyzing the pattern of biological thiols,the assay is capable of rapidly identifying six gut-derived bacteria including probiotics,neutral,and pathogenic strains based on fluorescent fingerprints within 5 min,and also discriminating bacteria and their mixtures with different composition.Using the assay that enables the simultaneous measurement of multiple gut-derived bacteria and their metabolites,the designed array achieved an accuracy of 0.99 when discriminating colorectal cancer(CRC)patient feces samples from healthy individuals.Remarkably,the as-prepared sensor array can also be used to identify various stages of CRC.The simplicity,rapidness,and cost-effectiveness of our approach render it a robust platform for the analysis of gut microbiota.展开更多
Buried channel array transistors enable fast and high-density integrated devices.The depth of the PN junction and carrier dynamics at the depletion layer in silicon wafers have a crucial influence on their performance...Buried channel array transistors enable fast and high-density integrated devices.The depth of the PN junction and carrier dynamics at the depletion layer in silicon wafers have a crucial influence on their performance and reliability.Therefore,rapid and non-contact/non-destructive inspection tools are necessary to accelerate the semiconductor industry.Despite the great efforts in this field,realizing a technique to probe the junction depth and carrier dynamics at the PN junction inside wafers remains challenging.Herein,we propose a new approach to access PN junctions embedded in wafers using terahertz(THz)emission spectroscopy.THz emission measurements and simulations demonstrate that the amplitude and polarity of THz emissions reflect the junction depth and carrier dynamics at the PN junctions.It allows us to evaluate the junction depth non-destructively with nanometer-scale accuracy,surpassing the limits of traditional techniques.Laser-induced THz emission spectroscopy is a promising method for the sensitive and non-contact/non-destructive evaluation of Si wafers and will benefit the modern semiconductor industry.展开更多
Background: Wolf-Hirschhorn syndrome (WHS) is a contiguous gene syndrome that is typically caused by a deletion of the distal portion of the short arm of chromosome 4. However, there are few reports about the featu...Background: Wolf-Hirschhorn syndrome (WHS) is a contiguous gene syndrome that is typically caused by a deletion of the distal portion of the short arm of chromosome 4. However, there are few reports about the features of Chinese WHS patients. This study aimed to characterize the clinical and molecular cytogenetic features of Chinese WHS patients using the combination of multiplex ligation-dependent probe amplification (MLPA) and array comparative genomic hybridization (array CGH). Methods: Clinical information was collected from ten patients with WHS. Genomic DNA was extracted from the peripheral blood of the patients. The deletions were analyzed by MLPA and array CGH. Results: All patients exhibited the core clinical symptoms of WHS, including severe growth delay, a Greek warrior helmet facial appearance, differing degrees of intellectual disability, and epilepsy or electroencephalogram anomalies. The 4p deletions ranged from 2.62 Mb to 17.25 Mb in size and included LETM1, WHSC1, and FGFR3. Conclusions: The combined use of MLPA and array CGH is an effective and specific means to diagnose WHS and allows for the precise identification of the breakpoints and sizes of deletions. The deletion of genes in the WHS candidate region is closely correlated with the core WHS phenotype.展开更多
In this study,interface shapes of horizontal oil–water two-phase flow are predicted by using Young-Laplace equation model and minimum energy model.Meanwhile,the interface shapes of horizontal oil–water twophase flow...In this study,interface shapes of horizontal oil–water two-phase flow are predicted by using Young-Laplace equation model and minimum energy model.Meanwhile,the interface shapes of horizontal oil–water twophase flow in a 20 mm inner diameter pipe are measured by a novel conductance parallel-wire array probe(CPAP).It is found that,for flow conditions with low water holdup,there is a large deviation between the model-predicted interface shape and the experimentally measured one.Since the variation of pipe wetting characteristics in the process of fluid flow can lead to the changes of the contact angle between the fluid and the pipe wall,the models mentioned above are modified by considering dynamic contact angle.The results indicate that the interface shapes predicted by the modified models present a good consistence with the ones measured by CPAP.展开更多
The edge plasma characteristics are studied by both a movable array of Much/Reynolds stress/Langmuir 10-probes in the boundary region and the fixed flush probe arrays on the 4 divertor neutralization plates at the sam...The edge plasma characteristics are studied by both a movable array of Much/Reynolds stress/Langmuir 10-probes in the boundary region and the fixed flush probe arrays on the 4 divertor neutralization plates at the same toroidal crosssection in the HL-2A tokamak. The dependence of the Reynolds stress on poloidal flow in the edge plasma is analysed. The result indicates that the sheared poloidal flow in tokamak plasma can be induced by the radial gradient of Reynolds stress. In the divertor experiments of HL-2A, the profiles of the electron temperature, density and floating potential on divertor plates are measured by the flush probe arrays. The edge electron temperature in divertor configuration is higher than that in limiter configuration. The temperature asymmetry between outer and inner target plates is observed. The result of magnetic surface reconstructed from 18 Mirnov coils signals is presented. Both the particle recycling and the impurity flux in the bulk plasma during divertor discharges are discussed. Neutral gas pressure in divertor chamber, measured by fast ionization gauge during divertor discharge, is given.展开更多
In ultrasonic phased-array testing, most probes are rigid with fixed elements. However, when testing a cambered piece, a rigid probe cannot be used directly, but an ultrasonic chock or coupling media must be used, w...In ultrasonic phased-array testing, most probes are rigid with fixed elements. However, when testing a cambered piece, a rigid probe cannot be used directly, but an ultrasonic chock or coupling media must be used, which adds cost and reduces the accuracy. The objective of this research was to improve the tests of cambered pieces. A flexible ultrasonic phased-array probe was developed to do the flexible phased- array testing. The key technologies in the flexible phased-array probe include the probe design and the phased-array control. A new method was developed to design the flexible probe according to the curvature of the piece and the test depth. The method includes the calculation of the element’s height (he), the relative rotation angle (ωe), the distance between the adjoining elements (de), and the element’s effective testing range. A flexible ultrasonic phased-array probe has been developed using this method.展开更多
基金supported by the National Natural Science Foundation of China(Nos.T2293730,T2293731,62121003,61960206012,61973292,62171434,61975206,and 61971400)the National Key Research and Development Program of China(Nos.2022YFC2402501 and 2022YFB3205602)+1 种基金the Major Program of Scientific and Technical Innovation 2030(No.2021ZD02016030)the Scientific Instrument Developing Project of the Chinese Academy of Sciences(No.GJJSTD20210004).
文摘Deep brain stimulation(DBS),including optical stimulation and electrical stimulation,has been demonstrated considerable value in exploring pathological brain activity and developing treatments for neural disorders.Advances in DBS microsystems based on implantable microelectrode array(MEA)probes have opened up new opportunities for closed-loop DBS(CL-DBS)in situ.This technology can be used to detect damaged brain circuits and test the therapeutic potential for modulating the output of these circuits in a variety of diseases simultaneously.Despite the success and rapid utilization of MEA probe-based CL-DBS microsystems,key challenges,including excessive wired communication,need to be urgently resolved.In this review,we considered recent advances in MEA probe-based wireless CL-DBS microsystems and outlined the major issues and promising prospects in this field.This technology has the potential to offer novel therapeutic options for psychiatric disorders in the future.
基金The National Natural Science Foundation of China (No.90307013,90707005)the Natural Science Foundation of Jiangsu Province(No. BK2008032)Open Foundation of State Key Laboratory of Bio-Electronics of Southeast University
文摘A neuronal signal detecting circuit and a neuronal signal stimulating circuit designed for a monolithic integrated MEA(micro-electrode array) system are described. As a basic cell of the circuits, an OPA( operational amplifier) is designed with low power, low noise, small size and high gain. The detecting circuit has a chip area of 290 μm × 400 μm, a power dissipation of 2.02 mW, an equivalent input noise of 17.72 nV/ Hz, a gain of 60. 5 dB, and an output voltage from - 2. 48 to + 2. 5 V. The stimulating circuit has a chip area of 130 μm × 290 μm, a power dissipation of 740 μW, and an output voltage from - 2. 5 to 2. 04 V. The parameters show that two circuits are suitable for a monolithic integrated MEA system. The detecting circuit and MEA have been fabricated. The test results show that the detecting circuit works well.
文摘An investigation was made into the argon plasma jet that expanded in a low-pressure vacuum chamber. The spatial distributions of the parameters of the plasma jet with different supplied powers were measured using a ten-channel Langmuir probe array. The chemical species in the plasma jet were identified by emission spectroscopy. The electron excitation temperatures at two positions, 10 cm and 50 cm downstream from the nozzle exit were calculated, respectively, by the Boltzmann plot method.
基金supported by National Natural Science Foundation of China(No.11105144)the Fundamental Research Funds for the Central Universities of China(No.WK2030040022)
文摘In this article, the design idea of a 57-pin Langmuir probe array is presented, together with some experimental results. The manufacture technique of the probe array is discussed. Two-dimensional distributions of the plasma density, the floating potential and their fluctuations in the poloidal cross section are obtained. The blobs, which move radially and poloidally, cause great particle and energy transport. The charge neutralization by the poloidal movement of particles greatly decreases the vertical electric field in the helimak plasma. This leads to a confinement time which is two orders of magnitude larger than the theoretical prediction.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China (Nos. 2019YFE03030000 and 2022YFE03020004)National Natural Science Foundation of China (Nos. 12105187, 11905250 and 11975275)+1 种基金the China Postdoctoral Science Foundation (No. 2021M702245)the Users with Excellence Program of Hefei Science Center, CAS (No. 2021HSC-UE014)。
文摘A novel electromagnetic probe array(EMPA) diagnostic, which consists of a magnetic probe array and an electrostatic probe array, has recently been developed on EAST. The EMPA is fixed near the first wall at horizontal port P. The magnetic probe array of the EMPA consists of 24 identical magnetic probes, each of them capable of measuring toroidal, poloidal and radial magnetic fluctuations simultaneously, providing additional toroidal magnetic fluctuation measurements compared with the regular magnetic probes on EAST. With a higher sampling rate and self-resonant frequency, the EMPA magnetic probes can provide higher frequency magnetic fluctuation measurements. The magnetic probe array of the EMPA is composed of two parallel layers of magnetic probes with a radial distance of 63 mm, and each layer of magnetic probes is arranged in four poloidal rows and three toroidal columns. The compact arrangement of the EMPA magnetic probe array largely improves the toroidal mode number measurement ability from-8≤ n≤ 8 to-112≤ n≤ 112, and also improves the high poloidal wave number measurement ability of magnetic fluctuations compared with the regular high frequency magnetic probes on EAST. The electrostatic probe array of the EMPA consists of two sets of four-tip probes and a single-tip probe array with three poloidal rows and four toroidal columns. It complements the electrostatic parameter measurements behind the main limiter and near the first wall in EAST. The engineering details of the EMPA diagnostic, including the mechanical system, the electrical system, the acquisition and control system, and the effective area calibration, are presented. The preliminary applications of the EMPA in L-mode and H-mode discharges on EAST have demonstrated that the EMPA works well for providing information on the magnetic and electrostatic fluctuations and can contribute to deeper physical analysis in future EAST experiments.
基金the Key Laboratory Funds for Science and Technology on Vacuum Technology and Physics Laboratory(No.HTKJ2022KL510002)the Military Test Instruments Program(No.2006ZCTF0054)。
文摘The accurate knowledge of the thrust vector eccentricity and beam divergence characteristics of Hall thrusters are of significant engineering value for the beneficial integration and successful application of Hall thrusters on spacecraft.For the characteristics of the plume bipolar diffusion due to the annular discharge channel of the Hall thruster,a Gaussian-fitted method for thrust vector deviation angle and beam divergence of Hall thrusters based on dual Faraday probe array planes was proposed in respect of the Hall thruster beam characteristics.The results show that the ratios of the deviation between the maximum and minimum values of the beam divergence angle and the thrust vector eccentricity angle using a Gaussian fit to the optimized Faraday probe dual plane to the mean value are 1.4%and 11.5%,respectively.The optimized thrust vector eccentricity angle obtained has been substantially improved,by approximately 20%.The beam divergence angle calculated using a Gaussian fitting to the optimized Faraday probe dual plane is approximately identical to the non-optimized one.The beam divergence and thrust vector eccentricity angles for different anode mass flow rates were obtained by averaging the beam divergence and thrust vector eccentricity angles calculated by the dual-plane,Gaussian-fitted ion current density method for different cross-sections.The study not only allows for an immediate and effective tool for determining the design of thrust vector adjustment mechanisms of spacecraft with different power Hall thrusters but also for characterizing the 3D spatial distribution of the Hall thruster plume.
文摘The working principle of the pipeline intelligent pig and the structure of ultrasonic probe array used to detect defects in oil/gas pipeline are introduced. The effects of the array' s radial position in pipe on defect resolution are analyzed. The causes leading to radial positioning error are investigated. An algo- rithm for the radial self-positioning is presented. The experimental results show that the radial self-positioning algorithm can eliminate the array' s space position error effectively and improve the defect resolution.
基金The National Natural Science Foundation of China(No. 61076118, 90307013, 90707005)the Natural Science Foundation of Jiangsu Province (No. BK2008032)Special Foundation and Open Foundation of the State Key Laboratory of Bioelectronics of Southeast University
文摘A microelectrode array(MEA) is presented, which is composed of 60 independent electrodes with 59 working ones and one reference one, and they are divided into 30 pairs. Except for the reference electrode, each pair consists of one stimulating electrode and one recording electrode. Supported by the peripheral circuits, four electrode states to study the bioelectrical signal of biological tissue or slice cultured in-vitro on the surface of the electrodes can be realized through each pair of electrodes. The four electrode states are stimulation, recording, stimulation and recording simultaneously, and isolation. The state of each pair of working electrodes can be arbitrarily controlled according to actual needs. The MEAs are fabricated in printed circuit board (PCB) technology. The total area of the PCB-based MEA is 49 mm × 49 mm. The impedance measurement of MEA is carried out in 0.9% sodium chloride solution at room temperature by means of 2-point measurements with an Agilent LCR meter, and the test signal for the impedance measurement is sinusoidal (AC voltage 50 mV, sweeping frequency 20 Hz to 10 kHz). The electrode impedance is between 200 and 3 kΩ while the frequency is between 500 and 1 000 Hz. The electrode impedance magnitude is inversely proportional to the frequency. Experiments of toad sciatic nerve in-vitro stimulation and recording and signal regeneration between isolated toad sciatic nerves are carried out on the PCB-based MEA. The results show that the MEA can be used for bioelectrical signal stimulation, recording, stimulation and recording simultaneously, and isolation of biological tissues or slices in-vitro.
文摘A theory model is established to describe the voltage-current responsefunction. The peak amplitude and the zero-crossing time of the transient signal is extracted as theimaging features, array pulsed eddy current (PEC) imaging is proposed to detect corrosion. The testresults show that this system has the advantage of fast scanning speed, different imaging mode andquantitative detection, it has a broad application in the aviation nondestructive testing.
基金This work has been supported by grants from the National Basic Research Program of China(973 program),Grant No.2009CB320303.
文摘Qualitative and quantitative analysis of trace heavy metals in aqueous environment are rapidly assuming significance along with the rapid development of industry.In this paper,gold microelectrode array(MEA)plated with mercury film was used for simultaneous voltammetric detection of zinc,cadmium,lead and copper ions in water.The electrochemical behavior and the actual surface area of the MEA were investigated by cyclic voltammetry in K_(3)[Fe(CN)_(6)].Electrochemical impedance spectrum(EIS)was utilized to examine the deposition of mercury on the electrode surface.Based on anodic stripping voltammetry,mercury filmAu MEA was applied to the detection of heavy metals in artificial analyte,where good calibrate linearity was obtained for cadmium,lead and copper ions,but with zinc exhibiting poor linearity.
文摘A manual inspection of large-diameter tubular joints is difficult. As a result a scanner with three degrees of freedom ( DOFs) was developed based on the scanning principle of ultrasonic phased array. The weld tracing is realized by a 2DOF motion of scanner. The pose of ultrasonic probe is controlled by the third one. The control strategy is put forward based on a programmable multi-axis controller. Four kinds of scanning modes can be implemented simultaneously employing this ultrasonic inspection system. Experiments on reference blocks of tubular joints reveal that the automatic ultrasonic phased array inspection system has the same inspection accuracy as a manual ultrasonic inspection. This system is superior to the manual ultrasonic system in terms of reliability and repeatability. The artificial dejects of weld at tubular joint can be detected accurately with the presented inspection system.
文摘We have develoPed a simPle and economical method f0r Chlamydia trachomatisdetecting, called microtiter plate hybridization (PCR-MPH), which may replace stan-dard PCR. This method is similar to that of an ELISA. Brithe, the PCR productslabeled at the 5'termini with biotin were hybridized with probes immobilized on a mi-crotiter well, and the bound PCR products were detected by streptavidin-c0njugatedenzymes followed by color development. Two inprovements have been made in immobi-lizing the probe to the microtiter wells, in terms of increasing both immobility and hy-bridization deciency. One is that singleustranded (ss )DNA, without the complemen-tary strand, is used. The other is that instead of a single copy, a tandem array of theprobe is used for immobilization and hybridization. Using of ssDNA containing abouta 5O-rePeat array of a relevant sequence as an immobilized probe, the sensitivity in-creased 1O-fold over that of a single oligonucleotide unit. We also found that the hy-brldizatlon condltions such as time, temPerature, and solution composition could be simplthed. The advantages of this microtiter plate-hybridization method for routinepathogens detecting are a short time assay, easy processing of large numbers of sansples, and the potential for automation.
基金supported by the National Natural Science Foundation of China(22376057,22274048,22274045,22074100,22274047,22104033)the Foundation of the Science&Technology Department of Hunan Province(2021ZJ1123,2023JJ30394)support from China Postdoctoral Science Foundation(2023M731053)。
文摘The gut microbiota and the associated metabolism play a pivotal role in maintaining human health,yet their assessment is challenging due to their inherent diversity,variety,and complexity.Herein,we developed a multichannel sensor array based on a single fluorescent probe,allowing for rapid and robust profiling gut microbiota and their key metabolites including cysteine(Cys),glutathione(GSH),and homocysteine(Hcy).The assay leverages the single fluorescent probe that is with multiple binding sites and the cross-reactive sensing principle to specifically recognize different biological thiols.By analyzing the pattern of biological thiols,the assay is capable of rapidly identifying six gut-derived bacteria including probiotics,neutral,and pathogenic strains based on fluorescent fingerprints within 5 min,and also discriminating bacteria and their mixtures with different composition.Using the assay that enables the simultaneous measurement of multiple gut-derived bacteria and their metabolites,the designed array achieved an accuracy of 0.99 when discriminating colorectal cancer(CRC)patient feces samples from healthy individuals.Remarkably,the as-prepared sensor array can also be used to identify various stages of CRC.The simplicity,rapidness,and cost-effectiveness of our approach render it a robust platform for the analysis of gut microbiota.
基金M.T.acknowledges support by JSPS KAKENHI Grant No.JP23H00184F.M.acknowledges support in part by Grantin-Aid for JSPS Fellows Grant No.23KJ1475 and Program for Leading Graduate Schools:“Interactive Materials Science Cadet Program”.
文摘Buried channel array transistors enable fast and high-density integrated devices.The depth of the PN junction and carrier dynamics at the depletion layer in silicon wafers have a crucial influence on their performance and reliability.Therefore,rapid and non-contact/non-destructive inspection tools are necessary to accelerate the semiconductor industry.Despite the great efforts in this field,realizing a technique to probe the junction depth and carrier dynamics at the PN junction inside wafers remains challenging.Herein,we propose a new approach to access PN junctions embedded in wafers using terahertz(THz)emission spectroscopy.THz emission measurements and simulations demonstrate that the amplitude and polarity of THz emissions reflect the junction depth and carrier dynamics at the PN junctions.It allows us to evaluate the junction depth non-destructively with nanometer-scale accuracy,surpassing the limits of traditional techniques.Laser-induced THz emission spectroscopy is a promising method for the sensitive and non-contact/non-destructive evaluation of Si wafers and will benefit the modern semiconductor industry.
文摘Background: Wolf-Hirschhorn syndrome (WHS) is a contiguous gene syndrome that is typically caused by a deletion of the distal portion of the short arm of chromosome 4. However, there are few reports about the features of Chinese WHS patients. This study aimed to characterize the clinical and molecular cytogenetic features of Chinese WHS patients using the combination of multiplex ligation-dependent probe amplification (MLPA) and array comparative genomic hybridization (array CGH). Methods: Clinical information was collected from ten patients with WHS. Genomic DNA was extracted from the peripheral blood of the patients. The deletions were analyzed by MLPA and array CGH. Results: All patients exhibited the core clinical symptoms of WHS, including severe growth delay, a Greek warrior helmet facial appearance, differing degrees of intellectual disability, and epilepsy or electroencephalogram anomalies. The 4p deletions ranged from 2.62 Mb to 17.25 Mb in size and included LETM1, WHSC1, and FGFR3. Conclusions: The combined use of MLPA and array CGH is an effective and specific means to diagnose WHS and allows for the precise identification of the breakpoints and sizes of deletions. The deletion of genes in the WHS candidate region is closely correlated with the core WHS phenotype.
基金supported by the National Natural Science Foundation of China(Grant Nos.41974139,41504104,11572220,51527805)Natural Science Foundation of Tianjin,China(19JCYBJC18400)。
文摘In this study,interface shapes of horizontal oil–water two-phase flow are predicted by using Young-Laplace equation model and minimum energy model.Meanwhile,the interface shapes of horizontal oil–water twophase flow in a 20 mm inner diameter pipe are measured by a novel conductance parallel-wire array probe(CPAP).It is found that,for flow conditions with low water holdup,there is a large deviation between the model-predicted interface shape and the experimentally measured one.Since the variation of pipe wetting characteristics in the process of fluid flow can lead to the changes of the contact angle between the fluid and the pipe wall,the models mentioned above are modified by considering dynamic contact angle.The results indicate that the interface shapes predicted by the modified models present a good consistence with the ones measured by CPAP.
文摘The edge plasma characteristics are studied by both a movable array of Much/Reynolds stress/Langmuir 10-probes in the boundary region and the fixed flush probe arrays on the 4 divertor neutralization plates at the same toroidal crosssection in the HL-2A tokamak. The dependence of the Reynolds stress on poloidal flow in the edge plasma is analysed. The result indicates that the sheared poloidal flow in tokamak plasma can be induced by the radial gradient of Reynolds stress. In the divertor experiments of HL-2A, the profiles of the electron temperature, density and floating potential on divertor plates are measured by the flush probe arrays. The edge electron temperature in divertor configuration is higher than that in limiter configuration. The temperature asymmetry between outer and inner target plates is observed. The result of magnetic surface reconstructed from 18 Mirnov coils signals is presented. Both the particle recycling and the impurity flux in the bulk plasma during divertor discharges are discussed. Neutral gas pressure in divertor chamber, measured by fast ionization gauge during divertor discharge, is given.
基金Supported by the Major Research Project of the "985" Fund of Tsinghua University (No. 012-081100501)
文摘In ultrasonic phased-array testing, most probes are rigid with fixed elements. However, when testing a cambered piece, a rigid probe cannot be used directly, but an ultrasonic chock or coupling media must be used, which adds cost and reduces the accuracy. The objective of this research was to improve the tests of cambered pieces. A flexible ultrasonic phased-array probe was developed to do the flexible phased- array testing. The key technologies in the flexible phased-array probe include the probe design and the phased-array control. A new method was developed to design the flexible probe according to the curvature of the piece and the test depth. The method includes the calculation of the element’s height (he), the relative rotation angle (ωe), the distance between the adjoining elements (de), and the element’s effective testing range. A flexible ultrasonic phased-array probe has been developed using this method.