As a new direct metal prototyping technology,the hybrid plasma and laser deposition manufacturing(PLDM)is proposed in this paper.In order to figure out the characteristics of plasma arc beam and mould in the PLDM proc...As a new direct metal prototyping technology,the hybrid plasma and laser deposition manufacturing(PLDM)is proposed in this paper.In order to figure out the characteristics of plasma arc beam and mould in the PLDM process of high temperature alloy,the high speed CCD camera is used to obtain the picture around the plasma arc.Afterwards the sketch of picture is clearly obtained.And the effect of laser parameter,such as average power,pulse width,pulse repetition frequency and the angle between laser beam and plasma arc beam on the plasma arc appearance,is studied experimentally.The results show that the modality of plasma arc beam is markedly influenced by laser beam.And the improvements of shape precision and surface state of the layer deposited by PLDM are confirmed.展开更多
An inverse problem of elastica of a variable-arclength beam subjected to a concentrated load is investigated. The beam is fixed at one end, and can slide freely over a hinge support at the other end. The inverse probl...An inverse problem of elastica of a variable-arclength beam subjected to a concentrated load is investigated. The beam is fixed at one end, and can slide freely over a hinge support at the other end. The inverse problem is to determine the value of the load when the deflection of the action point of the load is given. Based on the elasitca equations and the elliptic integrals, a set of nonlinear equations for the inverse problem are derived, and an analytical solution by means of iterations and Quasi-Newton method is presented. From the results, the relationship between the loads and deflections of the loading point is obtained.展开更多
The arc regulation method is applied to the high-current ion source for high-power hydrogen ion beam extraction for the first time. The characteristics of the arc and beam, including the probe ion saturation current, ...The arc regulation method is applied to the high-current ion source for high-power hydrogen ion beam extraction for the first time. The characteristics of the arc and beam, including the probe ion saturation current, the arc power and the beam current, are studied with feedback control. The results show that the arc regulation method can be successfully applied to ion beam extraction. This lays a sound foundation for the testing of a new ion source and the operation of a conditioned ion source for neutral beam injector devices.展开更多
There is increasing interest in the clinical use of flattening filter-free(FFF) beams.In this study,we aimed to investigate the dosimetric characteristics of volumetric modulated arc radiotherapy(VMAT) with FFF beams ...There is increasing interest in the clinical use of flattening filter-free(FFF) beams.In this study,we aimed to investigate the dosimetric characteristics of volumetric modulated arc radiotherapy(VMAT) with FFF beams for nasopharyngeal carcinoma(NPC).Ten NPC patients were randomly selected to undergo a RapidArc plan with either FFF beams(RA-FFF) or conventional beams(RA-C).The doses to the planning target volumes(PTVs),organs at risk(OARs),and normal tissues were compared.The technical delivery parameters for RapidArc plans were also assessed to compare the characteristics of FFF and conventional beams.Both techniques delivered adequate doses to PTVs.For PTVs,RA-C delivered lower maximum and mean doses and improved conformity and homogeneity compared with RA-FFF.Both techniques provided similar maximum doses to the optic nerves and lenses.For the brain stem,spinal cord,larynx,parotid glands,oral cavity,and skin,RA-FFF showed significant dose increases compared to RA-C.The dose to normal tissue was lower in RA-FFF.The monitor units(MUs) were(536 ± 46) MU for RA-FFF and(501± 25) MU for RA-C.The treatment duration did not significantly differbetween plans.Although both treatment plans could meet clinical needs,RA-C is dosimetrically superior to RA-FFF for NPC radiotherapy.展开更多
A series of experiments was carried out so as to elucidate the effect of the phase transformation in the cooling process on welding distortion and residual stress generated by laser beam welding (LBW) and laser-arc hy...A series of experiments was carried out so as to elucidate the effect of the phase transformation in the cooling process on welding distortion and residual stress generated by laser beam welding (LBW) and laser-arc hybrid welding (HYBW) on the high strength steel (HT780). Then, the experiments were simulated by 3D thermal elasticplastic analysis with FEM (Finite Element Method) which was performed with using the idealized mechanical properties considering the transformation superplasticity. From the results, the effects of the phase transformation on welding distortion and residual stress generated by LBW and HYBW were elucidated. Furthermore, the generality of the idealization of the mechanical properties was verified.展开更多
Diagnostic neutral beam (DNB), combined with spectral diagnostics, is employed to measure the ion temperature in HT-7. The factors affecting the extracted beam are studied in the experiment for the high performance ...Diagnostic neutral beam (DNB), combined with spectral diagnostics, is employed to measure the ion temperature in HT-7. The factors affecting the extracted beam are studied in the experiment for the high performance diagnostic neutral beam. A 6.5 A extracted hydrogen current at 43 keV of 100 ms was obtained after optimization. The extracted beam has a proton ratio as high as 40%, and can penetrate into the core plasma after neutralization to measure the ion temperature effectively.展开更多
基金This work was supported by the National Natural Science Foundation of China(Grant No.50474053)the State High-Technology Development Program of China(Grant No.2003AA421150).
文摘As a new direct metal prototyping technology,the hybrid plasma and laser deposition manufacturing(PLDM)is proposed in this paper.In order to figure out the characteristics of plasma arc beam and mould in the PLDM process of high temperature alloy,the high speed CCD camera is used to obtain the picture around the plasma arc.Afterwards the sketch of picture is clearly obtained.And the effect of laser parameter,such as average power,pulse width,pulse repetition frequency and the angle between laser beam and plasma arc beam on the plasma arc appearance,is studied experimentally.The results show that the modality of plasma arc beam is markedly influenced by laser beam.And the improvements of shape precision and surface state of the layer deposited by PLDM are confirmed.
基金The project supported by the National Natural Science Foundation of China(10272011)
文摘An inverse problem of elastica of a variable-arclength beam subjected to a concentrated load is investigated. The beam is fixed at one end, and can slide freely over a hinge support at the other end. The inverse problem is to determine the value of the load when the deflection of the action point of the load is given. Based on the elasitca equations and the elliptic integrals, a set of nonlinear equations for the inverse problem are derived, and an analytical solution by means of iterations and Quasi-Newton method is presented. From the results, the relationship between the loads and deflections of the loading point is obtained.
基金supported by the National Magnetic Confinement Fusion Science Program of China(No.2013GB101000)partly supported by National Natural Science Foundation of China(No.11075183)the Knowledge Innovation Program of the Chinese Academy of Sciences(Study of the physical characteristics of arc power feedback control for the high current ion source)
文摘The arc regulation method is applied to the high-current ion source for high-power hydrogen ion beam extraction for the first time. The characteristics of the arc and beam, including the probe ion saturation current, the arc power and the beam current, are studied with feedback control. The results show that the arc regulation method can be successfully applied to ion beam extraction. This lays a sound foundation for the testing of a new ion source and the operation of a conditioned ion source for neutral beam injector devices.
文摘There is increasing interest in the clinical use of flattening filter-free(FFF) beams.In this study,we aimed to investigate the dosimetric characteristics of volumetric modulated arc radiotherapy(VMAT) with FFF beams for nasopharyngeal carcinoma(NPC).Ten NPC patients were randomly selected to undergo a RapidArc plan with either FFF beams(RA-FFF) or conventional beams(RA-C).The doses to the planning target volumes(PTVs),organs at risk(OARs),and normal tissues were compared.The technical delivery parameters for RapidArc plans were also assessed to compare the characteristics of FFF and conventional beams.Both techniques delivered adequate doses to PTVs.For PTVs,RA-C delivered lower maximum and mean doses and improved conformity and homogeneity compared with RA-FFF.Both techniques provided similar maximum doses to the optic nerves and lenses.For the brain stem,spinal cord,larynx,parotid glands,oral cavity,and skin,RA-FFF showed significant dose increases compared to RA-C.The dose to normal tissue was lower in RA-FFF.The monitor units(MUs) were(536 ± 46) MU for RA-FFF and(501± 25) MU for RA-C.The treatment duration did not significantly differbetween plans.Although both treatment plans could meet clinical needs,RA-C is dosimetrically superior to RA-FFF for NPC radiotherapy.
文摘A series of experiments was carried out so as to elucidate the effect of the phase transformation in the cooling process on welding distortion and residual stress generated by laser beam welding (LBW) and laser-arc hybrid welding (HYBW) on the high strength steel (HT780). Then, the experiments were simulated by 3D thermal elasticplastic analysis with FEM (Finite Element Method) which was performed with using the idealized mechanical properties considering the transformation superplasticity. From the results, the effects of the phase transformation on welding distortion and residual stress generated by LBW and HYBW were elucidated. Furthermore, the generality of the idealization of the mechanical properties was verified.
基金supported by National Natural Science Foundation of China (No.10875146)
文摘Diagnostic neutral beam (DNB), combined with spectral diagnostics, is employed to measure the ion temperature in HT-7. The factors affecting the extracted beam are studied in the experiment for the high performance diagnostic neutral beam. A 6.5 A extracted hydrogen current at 43 keV of 100 ms was obtained after optimization. The extracted beam has a proton ratio as high as 40%, and can penetrate into the core plasma after neutralization to measure the ion temperature effectively.