期刊文献+
共找到52篇文章
< 1 2 3 >
每页显示 20 50 100
239Pu alpha spectrum analysis based on PIPS detector response function and variations with vacuum and distance 被引量:7
1
作者 Rui Shi Xian-Guo Tuo +3 位作者 Huai-Liang Li Jian-Bo Yang Yi Cheng Hong-Long Zheng 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第1期20-26,共7页
Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors tha... Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors that collectively cause the alpha spectrum to exhibit a well-known low-energy tail.Therefore,the estabUshment of an alpha spectrum detector response function from the perspective of a signaling system must consider the various factors mentioned above.The detector response function is the convolution of an alphaparticle pulse function,two exponential functions,and a Gaussian function,followed by calculation of the parameters of the detector response function using the weighted leastsquares fitting method as proposed in this paper.In our experiment,^(239)Pu alpha spectra were measured by a highresolution,passivated implanted planar silicon(PIPS)detector at 10 levels of vacuum and 10 source-detector distances.The spectrum-fitting results were excellent as evaluated by reduced Chi-square(x^2) and correlation coefficients.Finally,the variation of parameters with vacuum level and source-detector distance was studied.Results demonstrate that σ,τ_1,and τ_2 exhibit no obvious trend of variation with vacuum in the range 2000-20,000 mTorr,and at a confidence level of 95%,the values of τ_1 and τ_2 decline in a similar fashion with source-detector distance by the power exponential function,while the value of a declines linearly. 展开更多
关键词 alpha spectrum detector response function WEIGHTED least SQUARES PIPS detector
在线阅读 下载PDF
Determination of Alpha Particles Concentration in Toothpaste Using CR-39 Track Detector
2
作者 Fouad A. Majeed Inaam H. Kadhim +1 位作者 Ali O. Muhsen Khalid H. Abass 《Detection》 2015年第2期9-13,共5页
The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi m... The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples. 展开更多
关键词 alpha CONCENTRATION CR-39 detector FISSION TRACK Technique TOOTHPASTE
暂未订购
Optical Properties of CR-39 Track Etch Detectors Irradiated by Alpha Particles with Different Energies
3
作者 Mostafa Fawzy Eissa 《材料科学与工程(中英文版)》 2011年第1期26-31,共6页
关键词 径迹探测器 光学特性 径迹蚀刻 粒子辐照 能量通量 CR 阿尔法 光学性质
在线阅读 下载PDF
A New Method to Determine the Maximum Value of the Track Length of Alpha Particle in CR-39 Detector
4
作者 Hussein A. Ahmed A. Mohammed A. Said Ahmad 《Materials Sciences and Applications》 2015年第2期145-151,共7页
The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the ... The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program. 展开更多
关键词 Maximum Value of TRACK LENGTH CR-39 Range of alpha Particle Nuclear TRACK detector (NTD)
暂未订购
氡子体活度浓度测量系统的研究
5
作者 冯佳璐 何正忠 +2 位作者 王可欣 敖韬 刘宇凡 《核电子学与探测技术》 北大核心 2025年第3期334-342,共9页
氡是天然内照射的主要来源,氡的危害主要来自氡子体,因此,准确测量环境中氡子体活度浓度对评价氡暴露危害尤为重要。依托南华大学氡实验室,设计了一款氡子体活度浓度测量系统,该系统通过采样装置将氡子体气溶胶取样至滤膜,采用PIPS探测... 氡是天然内照射的主要来源,氡的危害主要来自氡子体,因此,准确测量环境中氡子体活度浓度对评价氡暴露危害尤为重要。依托南华大学氡实验室,设计了一款氡子体活度浓度测量系统,该系统通过采样装置将氡子体气溶胶取样至滤膜,采用PIPS探测器直接测量滤膜收集的氡子体α衰变信息,通过α能峰计数计算氡子体活度浓度值。对能峰重叠因子、滤膜过滤效率及自吸收因子三个系统关键参数进行测量,经过整体性能测试,达到设计要求。测试结果表明,测量系统对^(241)Am源与不同氡子体的峰位变化率均小于1%,可以实现不同氡子体活度浓度的可靠测量。该系统重量轻,携带方便,可搭载在其他装备上,方便在复杂环境下使用。 展开更多
关键词 氡室 氡子体 PIPS探测器 α能谱法 滤膜
在线阅读 下载PDF
自适应Alpha-beta修正的线谱检测后置处理方法 被引量:5
6
作者 戴文舒 陈新华 +1 位作者 孙长瑜 余华兵 《电子与信息学报》 EI CSCD 北大核心 2014年第10期2419-2424,共6页
矩形包络的单频信号时域频率方差等于频域有效带宽,且频率方差为信噪比的函数,在信噪比下降时,线谱方位权值计算误差变大,频率方差线谱检测器丢失目标。传统Alpha-beta滤波的增益恒定,不能有效修正频率估计。该文提出后置处理方法,将每... 矩形包络的单频信号时域频率方差等于频域有效带宽,且频率方差为信噪比的函数,在信噪比下降时,线谱方位权值计算误差变大,频率方差线谱检测器丢失目标。传统Alpha-beta滤波的增益恒定,不能有效修正频率估计。该文提出后置处理方法,将每个方位下多次求得的功率谱叠加后得到功率谱-频率曲线作为该方位下各频率对应的增益。当频率观测值对应的增益大时,新息在递推过程中占的比重大,当频率观测值对应的增益小时,预测值在递推过程中起的作用大,对滤波后频率估计值计算方差来修正方位谱输出。仿真和实验处理结果证明在低信噪比情况下,修正后的线谱检测后置处理算法抗干扰性强,能够实现弱线谱的提取,同时压低了干扰背景。 展开更多
关键词 水声信号处理 线谱检测 频率方差 alpha-beta滤波 后置处理
在线阅读 下载PDF
快速土壤α能谱测氡技术的应用研究
7
作者 刘建伟 董湘龙 丁卫撑 《核电子学与探测技术》 北大核心 2025年第9期1400-1405,共6页
土壤氡气测量作为一种重要的地球物理勘探技术,在地质领域具有重要的应用价值。本文通过对比分析多种氡气测量技术,探讨了野外场地对氡气测量技术的主要要求及其影响因素。研究中采用了一种高自动化、快速测量的土壤α能谱氡气测量技术... 土壤氡气测量作为一种重要的地球物理勘探技术,在地质领域具有重要的应用价值。本文通过对比分析多种氡气测量技术,探讨了野外场地对氡气测量技术的主要要求及其影响因素。研究中采用了一种高自动化、快速测量的土壤α能谱氡气测量技术,该仪器针对多点测量需求进行了优化。经测试与应用验证,由于采用双通道交替工作,现场零等待,工作效率最短为6~8分钟/测点。该技术在工程地质勘察、铀矿勘查、地下水勘探及其他矿产资源勘查等多个领域具有广泛的应用前景,为地质勘查工作提供了一种高效、经济且可靠的原位测量手段。 展开更多
关键词 氡气测量 土壤测氡 地球物理勘探 测氡仪 α能谱
在线阅读 下载PDF
Effect of Au/Ni/4H–SiC Schottky junction thermal stability on performance of alpha particle detection 被引量:1
8
作者 Xin Ye Xiao-Chuan Xia +5 位作者 Hong-Wei Liang Zhuo Li He-Qiu Zhang Guo-Tong Du Xing-Zhu Cui Xiao-Hua Liang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第8期482-486,共5页
Au/Ni/n-type 4H-SiC Schottky alpha particle detectors are fabricated and annealed at temperatures between 400℃ and 700 ℃ to investigate the effects of thermal stability of the Schottky contact on the structural and ... Au/Ni/n-type 4H-SiC Schottky alpha particle detectors are fabricated and annealed at temperatures between 400℃ and 700 ℃ to investigate the effects of thermal stability of the Schottky contact on the structural and electrical properties of the detectors. At the annealing temperature of 500 ℃, the two nickel silicides (i.e., Ni31Sil2 and Ni2Si) are formed at the interface and result in the formation of an inhomogeneous Schottky barrier. By increasing the annealing temperature, the Ni31Sil2 transforms into the more stable Ni2Si. The structural evolution of the Schottky contact directly affects the electrical properties and alpha particle energy resolutions of the detectors. A better energy resolution of 2.60% is obtained for 5.48-MeV alpha particles with the detector after being annealed at 600 ℃. As a result, the Au/Ni/n-type 4H-SiC Schottky detector shows a good performance after thermal treatment at temperatures up to 700℃. 展开更多
关键词 alpha particle detector silicon carbide thermal stability Schottky barrier
原文传递
Development of alpha surface contamination monitor based on THGEM for contamination distribution 被引量:3
9
作者 Si-Min Xiao Zhi-Ping Luo +5 位作者 Qian Liu Guo-Jun Yuan Hong-Chao Pang Yang Liu Jin-Feng Huang Shi Chen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第10期48-54,共7页
In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(T... In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(THGEM)has several advantages,including fast response time and good spatial resolution.Based on new THGEMs,a two-dimensional imaging detector was developed for alpha detection,with a position resolution greater than 3 mm.The detector design and test results are described in this paper.Fast radiation imaging SCMs,with a 40mm×40 mm sensitive area,are currently under development. 展开更多
关键词 THGEM detector Surface CONTAMINATION distribution alpha particle POSITION RESOLUTION Imaging detector
在线阅读 下载PDF
在量化阵列框架下的对称Alpha稳定信号检测的预处理方法 被引量:1
10
作者 陆炫宇 许凯嘉 +1 位作者 张国勇 王军 《信号处理》 CSCD 北大核心 2019年第8期1425-1431,共7页
本文主要研究了淹没在对称α稳态噪声下的信号相关检测的最优和次优的预测处理方法。使用量化阵列模型的等价处理函数和对相关运算的高斯近似,通过最大化相关器的输出信噪比,建立了约束泛函优化问题。由于量化阵列的泛函优化问题很难得... 本文主要研究了淹没在对称α稳态噪声下的信号相关检测的最优和次优的预测处理方法。使用量化阵列模型的等价处理函数和对相关运算的高斯近似,通过最大化相关器的输出信噪比,建立了约束泛函优化问题。由于量化阵列的泛函优化问题很难得到解析解,本文将预处理函数离散化,并证明离散后的优化问题是凸二次规划问题,从而可通过凸优化的方法求解。本文提出了一种基于排序方法的自适应门限的软限幅检测器,相比现有的检测器,仅仅需要估计噪声参数α。仿真结果表明,提出的量化阵列系统等价的预处理函数逼近最大似然检测器,提出的软限幅检测器达到了近似最优的性能,有利于实时处理α稳态信号。 展开更多
关键词 随机共振 量化阵列 非高斯 预处理 凸优化 Α稳定分布 软限幅检测器
在线阅读 下载PDF
高氡浓度地震监测泉在标准仪器校准方法中的应用研究
11
作者 李娜 祖丽皮牙·艾尼瓦尔 +2 位作者 李新勇 任宏微 黄建明 《内陆地震》 2024年第3期250-257,共8页
基于水氡浓度为20000~100000 Bq·m^(-3)的新09泉、新10泉和新15泉,利用国际刻度参考装置Alpha GUARD测氡仪及其水氡测量组件,开展标准仪器传递校准实验研究,校准K值相对误差分别为3.60%、-0.81%及2.09%。实验结果与氡气固体源校准... 基于水氡浓度为20000~100000 Bq·m^(-3)的新09泉、新10泉和新15泉,利用国际刻度参考装置Alpha GUARD测氡仪及其水氡测量组件,开展标准仪器传递校准实验研究,校准K值相对误差分别为3.60%、-0.81%及2.09%。实验结果与氡气固体源校准结果对比表明,水氡浓度在20000 Bq·m^(-3)以上水样可以通过标准仪器校准新方法检验,且利用不同水氡浓度的泉水不会影响校准结果准确性。新疆地球物理观测中心可利用高氡浓度的日常监测泉,将Alpha GUARD测氡仪作为标准仪器对FD-125型氡钍分析仪进行校准,从而替代固体氡源校准。本研究为地震监测氡观测的校准新方法操作技术规程及推广试用提供了数据支撑。 展开更多
关键词 地震监测 水氡 K值 标定方法 alpha GUARD测氡仪
在线阅读 下载PDF
Comparative Alpha Tracks Counting Using an Optical Microscope and a Spark Counter
12
作者 Dabo S. I. Agba Ponaho Kezo Issa Konaté 《Detection》 2023年第2期7-18,共12页
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ... In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements. 展开更多
关键词 LR 115 detector Optical Microscope Spark Counter alpha Track Density Calibration Factor Radon Concentration
在线阅读 下载PDF
伴随粒子中子检测系统发展及应用 被引量:1
13
作者 叶龙建 张东东 +1 位作者 杨振 陈宇航 《核技术》 EI CAS CSCD 北大核心 2024年第2期1-14,共14页
基于快中子技术的无损检测方法能够在不对检测物造成影响的情况下,发现其隐藏的危险品。利用D-T反应时伴随中子产生的反冲α粒子对有效中子进行标记,可大幅提高中子探测信噪比,同时通过空间分辨α粒子还可以获得被检测对象特征元素的空... 基于快中子技术的无损检测方法能够在不对检测物造成影响的情况下,发现其隐藏的危险品。利用D-T反应时伴随中子产生的反冲α粒子对有效中子进行标记,可大幅提高中子探测信噪比,同时通过空间分辨α粒子还可以获得被检测对象特征元素的空间信息,所以基于伴随α粒子的中子检测方法在安检领域具有重要的应用前景。本文简单介绍了基于伴随α粒子中子检测方法的原理和系统组成,并对系统的中子管、α粒子探测器和γ探测器等关键部件进行了介绍,接着介绍了目前世界上正在研究的伴随α粒子中子检测系统及其进展,最后对这种检测方法进行了展望。 展开更多
关键词 安全检测 伴随粒子 中子管 α粒子探测器 Γ探测器
原文传递
不同探源距下^(241)Am的α谱模拟与解析
14
作者 潘蓝天 李瑞 +4 位作者 范磊 黄欣杰 陈祥磊 王轶 刘兴宇 《辐射防护》 CAS CSCD 北大核心 2024年第S01期24-27,共4页
本文研究了^(241)Am的α能谱,并对其产生过程进行了分析。在此基础上,推导了探测器响应函数,并针对^(241)Am的α能谱,基于指数函数卷积高斯函数建立了探测器响应函数模型。采用加权非线性最小二乘法获取模型参数,并使用Reχ^(2)评估拟... 本文研究了^(241)Am的α能谱,并对其产生过程进行了分析。在此基础上,推导了探测器响应函数,并针对^(241)Am的α能谱,基于指数函数卷积高斯函数建立了探测器响应函数模型。采用加权非线性最小二乘法获取模型参数,并使用Reχ^(2)评估拟合优度。利用该模型对Geant4模拟得到的^(241)Am的α能谱进行重建,并研究了探测器与源之间的距离对拟合效果的影响。本文为搭建基于PIPS探测器的α谱仪和算法设计提供了理论指导。 展开更多
关键词 α能谱 探测器响应函数 加权非线性最小二乘法 Geant4模拟
在线阅读 下载PDF
基于Micromegas的紧凑型轻量化时间投影室研制
15
作者 靳尚泰 陈雷 +18 位作者 李沛玉 庄晓 张昀昱 卢志永 邓桂华 胡守扬 郭佳承 周静 孙鹏飞 宋金兴 赵明锐 贾世海 智宇 吝守龙 许天驹 王浩祯 蒋涛 赵永刚 李笑梅 《航天器环境工程》 CSCD 2024年第6期707-713,共7页
为实现紧凑、轻量的目标,采用128路二维条读出的光刻一体化微结构探测器作为时间投影室的核心读出探测器,并对该探测器的工作条件和性能进行研究。该时间投影室的灵敏体积为10cm×10cm×8 cm,总质量小于2.5 kg,探测器雪崩区厚度... 为实现紧凑、轻量的目标,采用128路二维条读出的光刻一体化微结构探测器作为时间投影室的核心读出探测器,并对该探测器的工作条件和性能进行研究。该时间投影室的灵敏体积为10cm×10cm×8 cm,总质量小于2.5 kg,探测器雪崩区厚度为100μm。为在保证时间投影室密封性的同时减小其总质量,采用双重嵌套结构低物质量腔室和法兰环式设计。通过引入共模扼流环减小探测器成像中的噪声幅度,消除成像中的噪点以及各路信号的周期性噪声。当腔室中工作气体为93%Ar+7%CO_(2),流速到达0.6 L/min时,测得α粒子的径迹。测试结果与Geant4软件的模拟结果显示出较好的一致性,验证了该时间投影室具有较佳的粒子径迹探测能力。 展开更多
关键词 光刻一体化微结构探测器 时间投影室 Α粒子 径迹成像
在线阅读 下载PDF
高效液相色谱法测定香附中α-香附酮的含量
16
作者 何桂英 邓竹君 +3 位作者 郑好 涂雨佳 岳玲燕 罗恩莉 《实验室检测》 2024年第5期18-21,共4页
目的通过高效液相色谱法(High Performance Liquid Chromatography,HPLC)探索香附中α-香附酮的提取方式和含量的测定方法,达到方法准确可靠简便易操作的目的。方法采用高效液相色谱法。色谱柱为Agilent Eclipse Plus,十八烷基硅烷键合... 目的通过高效液相色谱法(High Performance Liquid Chromatography,HPLC)探索香附中α-香附酮的提取方式和含量的测定方法,达到方法准确可靠简便易操作的目的。方法采用高效液相色谱法。色谱柱为Agilent Eclipse Plus,十八烷基硅烷键合硅胶色谱柱,150×4.6 mm,5μm,流动相为:甲醇—水(70:30),紫外-可见分光检测器;流速为1.0 mL/min;检测波长为240 nm;柱温为35℃。结果香附在0.02314-0.46287 mg/mL线性范围内呈良好线性关系,R2=1,平均回收率99.84%,RSD(Relative Standard Deviation)=0.09%。结论该方法操作简便,灵敏度高,重复性好,准确、可靠,可用于测定香附α-香附酮的含量,并有效控制香附的质量。 展开更多
关键词 香附 Α-香附酮 紫外-可见分光检测器 高效液相色谱法
在线阅读 下载PDF
4H-SiC肖特基二极管α探测器研究 被引量:4
17
作者 陈雨 范晓强 +5 位作者 蒋勇 吴健 白立新 柏松 陈刚 李理 《核电子学与探测技术》 CAS CSCD 北大核心 2013年第1期57-61,共5页
碳化硅(SiC)是一种具有优良物理性能的宽禁带半导体材料,可作为探测器的优良探测介质。用241Am源5.486 MeV的α粒子研究4H-SiC肖特基二极管α探测器的能量分辨率和信号相对上升时间等特性。在真空室中,使SiC探测器暴露在α粒子下,SiC探... 碳化硅(SiC)是一种具有优良物理性能的宽禁带半导体材料,可作为探测器的优良探测介质。用241Am源5.486 MeV的α粒子研究4H-SiC肖特基二极管α探测器的能量分辨率和信号相对上升时间等特性。在真空室中,使SiC探测器暴露在α粒子下,SiC探测器输出良好的响应信号。SiC二极管对5.486 MeVα粒子的能量分辨率最佳可达3.4%;经前置放大器FH1047输出和示波器观测,脉冲幅度随偏压增加而稳定在(35.39±0.21)mV;脉冲上升时间随偏压增加而稳定在(137.87±9.44)ns。4H-SiC肖特基二极管对α粒子响应良好,可用于α粒子强度测量。结合SiC耐辐照、耐高温等特性,进一步改进后有望制成分辨率更高、上升时间更快、耐辐照的新型α探测器和中子探测器。 展开更多
关键词 α探测器 肖特基二极管 4H—SiC
在线阅读 下载PDF
珠海市大气环境中氡浓度的测定 被引量:12
18
作者 陈迪云 陈智营 胡瑞英 《环境科学》 EI CAS CSCD 北大核心 1999年第6期94-97,共4页
采用固体径迹探测器累积氡测定方法对珠海市不同地质背景、不同的建筑风格的房屋室内、外地面水平氡浓度进行了测定⒚结果表明,珠海市室内、外空气中氡浓度的平均值分别为:1642 Bq/m 3 和752 Bq/m 3,居全国各... 采用固体径迹探测器累积氡测定方法对珠海市不同地质背景、不同的建筑风格的房屋室内、外地面水平氡浓度进行了测定⒚结果表明,珠海市室内、外空气中氡浓度的平均值分别为:1642 Bq/m 3 和752 Bq/m 3,居全国各大城市之首,仅次于我国的个旧地区,但大多数住房的室内氡浓度都低于200 Bq/m 3⒚研究发现秋冬季的室外氡浓度高于春夏季的室外氡浓度,而室内氡浓度的变化情况则相反,春夏季高于秋冬季;室内氡浓度随楼层的升高而呈降低的趋势⒚地下水多为强氡水。 展开更多
关键词 氡浓度 固体径迹探测器 大气环境
在线阅读 下载PDF
α/β粒子在不同类型探测器上的能量响应及其等效因子的一致性 被引量:6
19
作者 林炳兴 李光宪 林立雄 《辐射防护》 CAS CSCD 北大核心 2011年第5期292-299,322,共9页
通过测量不同类型探测器或同一类型探测器不同台(路)对不同能量α/β放射性粒子的计数效率和等效因子,比较它们之间等效因子的一致性,探讨各类型探测装置在总放射性测量中的适应性。结果显示,常用的3种探测器即复合有机闪烁体、流气式... 通过测量不同类型探测器或同一类型探测器不同台(路)对不同能量α/β放射性粒子的计数效率和等效因子,比较它们之间等效因子的一致性,探讨各类型探测装置在总放射性测量中的适应性。结果显示,常用的3种探测器即复合有机闪烁体、流气式正比计数器、金硅面垒半导体探测器对总α和总β粒子的计数效率-粒子能量关系总体上一致,总α计数效率与能量呈指数关系,总β计数效率与能量呈对数关系,低能β出现偏转。3种探测器能量响应比对的实验结果显示,复合有机闪烁体和流气式正比计数器两者的α和β等效因子具有良好的一致性,而金硅面垒半导体探测器对α测量的等效因子与前两种探测器相似,但是对β粒子的能量响应有显著差异,低能β等效因子明显偏低,因此金硅面垒半导体探测器不宜于总放射性测量和食品卫生检验。 展开更多
关键词 α/β粒子 探测器 能量响应 等效因子
在线阅读 下载PDF
α粒子测量仪器现状与发展趋势 被引量:12
20
作者 杨明太 《核电子学与探测技术》 CAS CSCD 北大核心 2011年第11期1198-1201,共4页
综述了可用于α粒子测量的常用α探测器(气体探测器、闪烁探测器和半导体探测器)、特种α探测器(原子核乳胶和固体径迹探测器)、α强度测量仪(闪烁计数仪、α活度测量仪、α表面污染仪和低本底α测量仪)、α能谱测量仪和α磁谱仪的主要... 综述了可用于α粒子测量的常用α探测器(气体探测器、闪烁探测器和半导体探测器)、特种α探测器(原子核乳胶和固体径迹探测器)、α强度测量仪(闪烁计数仪、α活度测量仪、α表面污染仪和低本底α测量仪)、α能谱测量仪和α磁谱仪的主要性能指标及其现状,并对其发展趋势与应用前景进行了展望。 展开更多
关键词 α探测器 α测量仪 综述
在线阅读 下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部