期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Reduction of photoreceptor cell packing density in low or moderative myopia detected with adaptive optics scanning laser ophthalmoscopy
1
作者 Lin-Yi Lei Yue Zhao +2 位作者 Tang-Ren Cai Si-Guo Feng Jin Yao 《International Journal of Ophthalmology(English edition)》 2025年第4期683-690,共8页
AIM:To assess the variations in photoreceptor cell packing density(PCPD)across the retina among young healthy individuals with emmetropia,low and moderate myopia.METHODS:High-resolution adaptive optics scanning laser ... AIM:To assess the variations in photoreceptor cell packing density(PCPD)across the retina among young healthy individuals with emmetropia,low and moderate myopia.METHODS:High-resolution adaptive optics scanning laser ophthalmoscopy(AOSLO)systems were utilized for retinal imaging with a large sampling window of 700μm×700μm.The study cohort included 14 emmetropic[spherical equivalent(SE)ranged+0.5 to-0.5 D],15 low myopic(SE ranged-0.5 to-3 D)and 21 moderate myopic(SE ranged-3 to-6 D)healthy young adults.Photoreceptors at 3°temporal,6°superior and inferior 6°were captured.Statistical analysis was then performed to obtain PCPD and cell spacing.RESULTS:The average age of participants was 22.54±2.86(ranged 20–30y)with no difference among 3 groups.At 3°temporal,the emmetropic group exhibited the highest PCPD of 15186.16±2050.54 cells/mm^(2),while the low and moderate myopic groups had PCPD of 14009.15±1073.01 and 13466.92±1121.71 cells/mm2,respectively.At 3°temporal,the emmetropic group also had the smallest cell spacing at 6.66±0.26 mm,compared to 6.85±0.26 and 6.91±0.28 mm for the low and moderate myopic groups,respectively.Compared to the emmetropic group,at 3°temporal,the myopic groups showed significantly reduced PCPD(low myopia:P=0.032;moderate myopia:P=0.001).At 6°inferior,the moderate myopic group exhibited a significant decrease in PCPD(P=0.013),while at 6°superior,there were no significant statistical differences in PCPD for the low and moderate myopic groups(P>0.05).In comparison to the emmetropic group,only the moderate myopic group showed significantly increased cell spacing at all three positions(temporal 3°:P=0.011,superior 6°:P=0.046,inferior 6°:P=0.013).Correlation analysis revealed a positive correlation between PCPD and axial length changes(P<0.05).CONCLUSION:Reduced PCPD and increased cell spacing strongly correlated with refractive error in mild to moderate myopic eyes,especially at 6°inferior to the fovea and the decreased PCPD in the macular region of myopic patients may be associated with increased axial lengthinduced retinal stretching. 展开更多
关键词 adaptive optics scanning laser ophthalmoscopy photoreceptor cell packing density FOVEA refractive error MYOPIA
原文传递
Automated cone photoreceptor cell identication in confocal adaptive optics scanning laser ophthalmoscope images based on object detection 被引量:6
2
作者 Yiwei Chen Yi He +4 位作者 Jing Wang Wanyue Li Lina Xing Xin Zhang Guohua Shi 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2022年第1期103-109,共7页
Cone photoreceptor cell identication is important for the early diagnosis of retinopathy.In this study,an object detection algorithm is used for cone cell identication in confocal adaptive optics scanning laser ophtha... Cone photoreceptor cell identication is important for the early diagnosis of retinopathy.In this study,an object detection algorithm is used for cone cell identication in confocal adaptive optics scanning laser ophthalmoscope(AOSLO)images.An effectiveness evaluation of identication using the proposed method reveals precision,recall,and F_(1)-score of 95.8%,96.5%,and 96.1%,respectively,considering manual identication as the ground truth.Various object detection and identication results from images with different cone photoreceptor cell distributions further demonstrate the performance of the proposed method.Overall,the proposed method can accurately identify cone photoreceptor cells on confocal adaptive optics scanning laser ophthalmoscope images,being comparable to manual identication. 展开更多
关键词 Biomedical image processing retinal imaging adaptive optics scanning laser ophthalmoscope object detection.
原文传递
Programmable Adaptive Security Scanning for Networked Microgrids 被引量:4
3
作者 Zimin Jiang Zefan Tang +1 位作者 Peng Zhang Yanyuan Qin 《Engineering》 SCIE EI 2021年第8期1087-1100,共14页
Communication-dependent and software-based distributed energy resources(DERs)are extensively integrated into modern microgrids,providing extensive benefits such as increased distributed controllability,scalability,and... Communication-dependent and software-based distributed energy resources(DERs)are extensively integrated into modern microgrids,providing extensive benefits such as increased distributed controllability,scalability,and observability.However,malicious cyber-attackers can exploit various potential vulnerabilities.In this study,a programmable adaptive security scanning(PASS)approach is presented to protect DER inverters against various power-bot attacks.Specifically,three different types of attacks,namely controller manipulation,replay,and injection attacks,are considered.This approach employs both software-defined networking technique and a novel coordinated detection method capable of enabling programmable and scalable networked microgrids(NMs)in an ultra-resilient,time-saving,and autonomous manner.The coordinated detection method efficiently identifies the location and type of power-bot attacks without disrupting normal NM operations.Extensive simulation results validate the efficacy and practicality of the PASS for securing NMs. 展开更多
关键词 Networked microgrids Programmable adaptive security scanning Coordinated detection Software defined networking
在线阅读 下载PDF
Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update 被引量:7
4
作者 Bing Zhang Ni Li +2 位作者 Jie Kang Yi He Xiao-Ming Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第11期1751-1758,共8页
Adaptive optics scanning laser ophthalmoscopy(AOSLO) has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics(AO) and AO-SLO. Then it co... Adaptive optics scanning laser ophthalmoscopy(AOSLO) has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics(AO) and AO-SLO. Then it compares AO-SLO with conventional imaging methods(fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography) and other AO techniques(adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherence tomography). Furthermore, an update of current research situation in AO-SLO is made based on different fundus structures as photoreceptors(cones and rods), fundus vessels, retinal pigment epithelium layer, retinal nerve fiber layer, ganglion cell layer and lamina cribrosa. Finally, this review indicates possible research directions of AO-SLO in future. 展开更多
关键词 adaptive optics scanning laser ophthalmoscopy retina fundus imaging
原文传递
Bimorph deformable mirror based adaptive optics scanning laser ophthalmoscope for retina imaging in vivo 被引量:5
5
作者 王媛媛 何益 +4 位作者 魏凌 李喜琪 杨金生 周虹 张雨东 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第12期43-47,共5页
A bimorph deformable mirror (DM) with a large stroke of more than 30 μm using 35 actuators is presented and characterized for an adaptive optics (AO) confocal scanning laser ophthalmoscope application. Facilitate... A bimorph deformable mirror (DM) with a large stroke of more than 30 μm using 35 actuators is presented and characterized for an adaptive optics (AO) confocal scanning laser ophthalmoscope application. Facilitated with a Shack-Hartmann wavefront sensor, the bimorph DM-based AO operates closed-loop AO corrections for hu- man eyes and reduces wavefront aberrations in most eyes to below 0.1 μm rms. Results from living eyes, including one exhibiting ~5D of myopia and ~2D of astigmatism along with notable high-order aberrations, reveal a prac- tical efficient aberration correction and demonstrate a great benefit for retina imaging, including improving resolution, increasing brightness, and enhancing the contrast of images. 展开更多
关键词 Bimorph deformable mirror based adaptive optics scanning laser ophthalmoscope for retina imaging in vivo DM AO
原文传递
Automated superpixels-based identification and mosaicking of cone photoreceptor cells for adaptive optics scanning laser ophthalmoscope 被引量:3
6
作者 Yiwei Chen Yi He +4 位作者 Jing Wang Wanyue Li Lina Xing Feng Gao Guohua Shi 《Chinese Optics Letters》 SCIE EI CAS CSCD 2020年第10期48-52,共5页
An automated superpixels identification/mosaicking method is presented for the analysis of cone photoreceptor cells with the use of adaptive optics scanning laser ophthalmoscope(AO-SLO) images. This is an image overse... An automated superpixels identification/mosaicking method is presented for the analysis of cone photoreceptor cells with the use of adaptive optics scanning laser ophthalmoscope(AO-SLO) images. This is an image oversegmentation method used for the identification and mosaicking of cone photoreceptor cells in AO-SLO images.It includes image denoising, estimation of the cone photoreceptor cell number, superpixels segmentation, merging of superpixels, and final identification and mosaicking processing steps. The effectiveness of the presented method was confirmed based on its comparison with a manual method in terms of precision, recall, and F1-score of 77.3%, 95.2%, and 85.3%, respectively. 展开更多
关键词 biomedical optics retinal imaging adaptive optics scanning laser ophthalmoscope cone photo-receptor cell superpixels
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部