期刊文献+
共找到104篇文章
< 1 2 6 >
每页显示 20 50 100
THE OPTIMAL ACTIVITY DISTRIBUTION IN NONISOTHERMAL PELLETS
1
作者 吴华 袁权 朱葆琳 《Chinese Journal of Chemical Engineering》 SCIE EI CAS 1985年第1期166-179,共14页
The nonisothermal effectiveness fcator for reaction with kinetics r=kc^m/(l+Kc)~a can be improved bycatalysts with nonuniform activity distribution.The optimal distribution function in one-dimensional modelwith which ... The nonisothermal effectiveness fcator for reaction with kinetics r=kc^m/(l+Kc)~a can be improved bycatalysts with nonuniform activity distribution.The optimal distribution function in one-dimensional modelwith which the effectiveness factor can be maximized is a δ-function which means that the activity of thecatalyst should be concentrated on a layer with negligible thickness in a precise locationfrom the centerof pellets.The general equations for predicting the value ofand maximum effectiveness factor as a functionof thermodynamic,kinetic and transport parameters are derived and they can be given explicitly in the case ofa=O,m=a or isothermal reaction.An active layer with definite thickness and a deviation from the optimal locationboth decrease thevalue of the effectiveness factor.It has been shown numerically that the effectiveness factor decreases slightlywith an active layer at the inner side of x but seriously at outer side. 展开更多
关键词 THE OPTIMAL activity distribution IN NONISOTHERMAL PELLETS
在线阅读 下载PDF
Developmental Lead Exposure Alters the Distribution of Protein Kinase C Activity in the Rat Hippocampus 被引量:7
2
作者 HWEI-HSIEN CHEN TANGENG MA +1 位作者 ARTHUR S. HUME AND ING K. HO(Deportment of Pharmacology and Toxicology, University ofMississippi Medical Center, 2500 North State Street,Jackson, MS 39216, USA) 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 1998年第1期61-69,共9页
Chronic low-level lead (Pb) exposure in children is known to cause a deficit in learning and memory. In vitro studies have demonstrated that Pb altered protein kinase C (PKC) activityt Especially, hippocampal PKC has ... Chronic low-level lead (Pb) exposure in children is known to cause a deficit in learning and memory. In vitro studies have demonstrated that Pb altered protein kinase C (PKC) activityt Especially, hippocampal PKC has been correlated with performance in several learning tasks. The effects of Pb exposure on hippocampal PKC were investigated during development at various postnatal ages: postnatal day (PN) 7, 14, 28, and 56. Two-tenth % Pb acetate was administered to pregnant and lactating dams and then administered to weanling rats in drinking water. PKC activity was measured in both membrane and cytosolic fractions from the hippocampi of the controls and Pb-exposed animals. Pb-induced increase in PKC activity in the cytosolic fraction was obsereved in the PN56 rats. In contrast, PKC activity was decreased by Pb at PN7 in the membrane fraction. Furthermore, a significant decrease in the ratio of membrane to cytosolic PKC activity which is representative of PKC distribution was observed in the PN28 and PN56 Pb-exposed rats relative to the same-age controls. This study indicates that chronic Pb exposure during development influences hippocampal PKC activity and distribution. These changes may be involved in the subclinical neurotoxicity of chronic Pb exposure in young children. 展开更多
关键词 activity PB Developmental Lead Exposure Alters the distribution of Protein Kinase C activity in the Rat Hippocampus
暂未订购
Ultrafine Fraction and Aerosol Attached Activity Size Distribution of Radon Progeny in Living Room 被引量:2
3
作者 Amer Mohamed Mohamed Moustafa lotfy Abd EI-Hady Mona Moustafa Mahmoud Mostafa Yuness Abd El Fatah 《Journal of Physical Science and Application》 2012年第7期205-215,共11页
Inhalation of 222Rn progeny in the domestic environment contributes the greatest fraction of the natural radiation exposure to the public. The ultrafine activity of these progeny amounts up to about l 0 percent of the... Inhalation of 222Rn progeny in the domestic environment contributes the greatest fraction of the natural radiation exposure to the public. The ultrafine activity of these progeny amounts up to about l 0 percent of the total activity (attached and ultrafine), but is considered to yield about 50 percent of the total radiation dose. Therefore, measurements of ultrafine fraction are essential for the estimation of radiation dose. The current study presents measured data on the total equilibrium equivalent concentration (EEC) and ultrafine equilibrium equivalent concentration (EECUn), ultrafine fraction (fb), attached and unattached activity size distributions of radon progeny in the low ventilated rooms at Minia University, Minia city, Egypt. A screen diffusion battery was used for collection the ultrafine fraction and measuring the total activity concentration of radon progeny. The attached activity size distribution of 214pb is determined by using a low pressure cascade impactor. The EEC of radon progeny varied between 1.3 and 18.9 Bq/m3 with a mean value of 5.2 ± 0.48 Bq/m2. The mean activity thermodynamic diameter (AMTD) ofultrafine of radon progeny was determined to be 1.26 nm with relative mean geometric standard deviations (GSD) of 1.3. The ultrafine fraction of radon progeny, fb, has a range 0.01 to 0.21 with an average of 0.08 ± 0.03. A relative mean GSD of 2.7 was determined for attached 2Lapb at a mean active median aerodynamic diameter (AMD) of 350 nm. Based on the above experimental results, the deposition fractions have been evaluated in each air way generation through the human lung by applying a lung deposition model. The bronchial deposition efficiencies of particles in the size range of attached radon progeny were found to be lower than those of ultrafine progeny. The effect of radon progeny deposition by adult male has been also studied for various levels of physical exertion. The dose conversion factor has been discussed as a function of fb. 展开更多
关键词 AEROSOL radon progeny activity size distribution ultrafine fraction and attached fraction.
在线阅读 下载PDF
Diazinon Toxicokinetics, Tissue Distribution and Anticholinesterase Activity in the Rat
4
作者 H. X. WU CL. EVREUX-GROS AND J. DESCOTESa (Department of Pharmacology and Medical Toxicology, INSERM U80,LYON-RTH Laennec Faculty of Medicine, 69008 Lyon France) 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 1996年第4期359-369,共11页
The toxicokinetics, tissue distribution, and anticholinesteruse (antiChE ) activity of diazinon were investigated in the rat. Plasma concentrations most adequately fitted a two-compartment open model after iv adminis... The toxicokinetics, tissue distribution, and anticholinesteruse (antiChE ) activity of diazinon were investigated in the rat. Plasma concentrations most adequately fitted a two-compartment open model after iv administration of 10 mg/kg and a one-compartment model after oral administration of 80 mg/kg. Diazinon elimination half-life following iv and oral dosing was 4.70 and 2.86 h, respectively. The oral bioavailabllity was found to be low (35.5%). Hepatic extraction ratios after iv administration of 5 or 10 mg 展开更多
关键词 activity Diazinon Toxicokinetics Tissue distribution and Anticholinesterase activity in the Rat
在线阅读 下载PDF
Reactive Power Optimization Model of Active Distribution Network with New Energy and Electric Vehicles 被引量:1
5
作者 Chenxu Wang Jing Bian Rui Yuan 《Energy Engineering》 2025年第3期985-1003,共19页
Considering the uncertainty of grid connection of electric vehicle charging stations and the uncertainty of new energy and residential electricity load,a spatio-temporal decoupling strategy of dynamic reactive power o... Considering the uncertainty of grid connection of electric vehicle charging stations and the uncertainty of new energy and residential electricity load,a spatio-temporal decoupling strategy of dynamic reactive power optimization based on clustering-local relaxation-correction is proposed.Firstly,the k-medoids clustering algorithm is used to divide the reduced power scene into periods.Then,the discrete variables and continuous variables are optimized in the same period of time.Finally,the number of input groups of parallel capacitor banks(CB)in multiple periods is fixed,and then the secondary static reactive power optimization correction is carried out by using the continuous reactive power output device based on the static reactive power compensation device(SVC),the new energy grid-connected inverter,and the electric vehicle charging station.According to the characteristics of the model,a hybrid optimization algorithm with a cross-feedback mechanism is used to solve different types of variables,and an improved artificial hummingbird algorithm based on tent chaotic mapping and adaptive mutation is proposed to improve the solution efficiency.The simulation results show that the proposed decoupling strategy can obtain satisfactory optimization resultswhile strictly guaranteeing the dynamic constraints of discrete variables,and the hybrid algorithm can effectively solve the mixed integer nonlinear optimization problem. 展开更多
关键词 Active distribution network new energy electric vehicles dynamic reactive power optimization kmedoids clustering hybrid optimization algorithm
在线阅读 下载PDF
Security distance analysis of active distribution network considering energy hub demand response
6
作者 Rui Ma Qi Zhou +2 位作者 Shengyang Liu Qin Yan Mo Shi 《Global Energy Interconnection》 2025年第1期160-173,共14页
This study proposes a method for analyzing the security distance of an Active Distribution Network(ADN)by incorporating the demand response of an Energy Hub(EH).Taking into account the impact of stochastic wind-solar ... This study proposes a method for analyzing the security distance of an Active Distribution Network(ADN)by incorporating the demand response of an Energy Hub(EH).Taking into account the impact of stochastic wind-solar power and flexible loads on the EH,an interactive power model was developed to represent the EH’s operation under these influences.Additionally,an ADN security distance model,integrating an EH with flexible loads,was constructed to evaluate the effect of flexible load variations on the ADN’s security distance.By considering scenarios such as air conditioning(AC)load reduction and base station(BS)load transfer,the security distances of phases A,B,and C increased by 17.1%,17.2%,and 17.7%,respectively.Furthermore,a multi-objective optimal power flow model was formulated and solved using the Forward-Backward Power Flow Algorithm,the NSGA-II multi-objective optimization algo-rithm,and the maximum satisfaction method.The simulation results of the IEEE33 node system example demonstrate that after opti-mization,the total energy cost for one day is reduced by 0.026%,and the total security distance limit of the ADN’s three phases is improved by 0.1 MVA.This method effectively enhances the security distance,facilitates BS load transfer and AC load reduction,and contributes to the energy-saving,economical,and safe operation of the power system. 展开更多
关键词 Active distribution network Energy hub Security distance Base station load Air-conditioning load
在线阅读 下载PDF
Analyzing the Resilience of Active Distribution Networks to Hazardous Weather Considering Cyber-Physical Interdependencies
7
作者 Zhiyi Li Xutao Han +2 位作者 Mohammad Shahidehpour Ping Ju Qun Yu 《Engineering》 2025年第8期15-36,共22页
This paper provides a systematic review on the resilience analysis of active distribution networks(ADNs)against hazardous weather events,considering the underlying cyber-physical interdependencies.As cyber-physical sy... This paper provides a systematic review on the resilience analysis of active distribution networks(ADNs)against hazardous weather events,considering the underlying cyber-physical interdependencies.As cyber-physical systems,ADNs are characterized by widespread structural and functional interdependen-cies between cyber(communication,computing,and control)and physical(electric power)subsystems and thus present complex hazardous-weather-related resilience issues.To bridge current research gaps,this paper first classifies diverse hazardous weather events for ADNs according to different time spans and degrees of hazard,with model-based and data-driven methods being utilized to characterize weather evolutions.Then,the adverse impacts of hazardous weather on all aspects of ADNs’sources,physical/cyber networks,and loads are analyzed.This paper further emphasizes the importance of situational awareness and cyber-physical collaboration throughout hazardous weather events,as these enhance the implementation of preventive dispatches,corrective actions,and coordinated restorations.In addition,a generalized quantitative resilience evaluation process is proposed regarding additional considerations about cyber subsystems and cyber-physical connections.Finally,potential hazardous-weather-related resilience challenges for both physical and cyber subsystems are discussed. 展开更多
关键词 Cyber–physical interdependency Resilience analysis Active distribution network Hazardous weather event
在线阅读 下载PDF
Quantum-accelerated active distribution network planning based on coherent photonic quantum computers
8
作者 Yu Xin Haipeng Xie Wei Fu 《iEnergy》 2025年第2期107-120,共14页
Active distribution network(ADN)planning is crucial for achieving a cost-effective transition to modern power systems,yet it poses significant challenges as the system scale increases.The advent of quantum computing o... Active distribution network(ADN)planning is crucial for achieving a cost-effective transition to modern power systems,yet it poses significant challenges as the system scale increases.The advent of quantum computing offers a transformative approach to solve ADN planning.To fully leverage the potential of quantum computing,this paper proposes a photonic quantum acceleration algorithm.First,a quantum-accelerated framework for ADN planning is proposed on the basis of coherent photonic quantum computers.The ADN planning model is then formulated and decomposed into discrete master problems and continuous subproblems to facilitate the quantum optimization process.The photonic quantum-embedded adaptive alternating direction method of multipliers(PQA-ADMM)algorithm is subsequently proposed to equivalently map the discrete master problem onto a quantum-interpretable model,enabling its deployment on a photonic quantum computer.Finally,a comparative analysis with various solvers,including Gurobi,demonstrates that the proposed PQA-ADMM algorithm achieves significant speedup on the modified IEEE 33-node and IEEE 123-node systems,highlighting its effectiveness. 展开更多
关键词 Active distribution network planning coherent photonic quantum computer photonic quantum-embedded adaptive ADMM algorithm quantum computing
在线阅读 下载PDF
EFFECTS OF EXTERNAL DONOR ON ACTIVE CENTER DISTRIBUTION OF SUPPORTED ZIEGLER-NATTA CATALYST 被引量:1
9
作者 范志强 M.CarmelaSacchi PaoloLocatelli 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1997年第3期217-225,共9页
The composition distribution (CD) and microisotacticity distribution (ID) of propene/1-hexene copolymer synthesized by MgCl2/DIBP/TiCl4 (DIBP: diisobutyl phthalate) were determined by fractionating the copolymers acco... The composition distribution (CD) and microisotacticity distribution (ID) of propene/1-hexene copolymer synthesized by MgCl2/DIBP/TiCl4 (DIBP: diisobutyl phthalate) were determined by fractionating the copolymers according to crystallinity and characterizing the fractions by (CNMR)-C-13. The effects of two alkoxysilane donors, triethoxyphenylsilane (PTES) and dimethoxydi-tert-butylsilane (TBMS), on CD and ID of the copolymers were compared. Three main parts in the CD diagram of each copolymer were distinguished, which were correlated to active center distribution (ACD) based on three groups of different active centers. By studying the changes in l-hexene content, microisotacticity and reactivity ratio product of three typical fractions, the effects of external donor on ACD were better elucidated. It was found that TBMS shows much stronger effects on ACD than PTES. In the former system, most fractions were produced on active centers with relatively lower r(1)r(2), higher reactivity to I-hexene, and higher stereospecificity as compared to the system without external donor. It is concluded that the observed very extensive changes in ACD are mainly resulted by the formation of new types of active centers, possibly by coordination of external donor to certain positions on the catalyst. 展开更多
关键词 supported Ziegler-Natta catalyst propene/1-hexene copolymer external donor active center distribution
在线阅读 下载PDF
Radioactive Element Distribution Characteristics of Red Mud based Field Road Cement before and after Hydration 被引量:1
10
作者 王晓 MA Juntao +1 位作者 ZHANG Lei 杨久俊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第2期452-458,共7页
Red mud was firstly used as a raw material in sintering field road cement. Then, the radioactive element distribution characteristics of red mud based field road cement(RFC) before and after hydration were comparati... Red mud was firstly used as a raw material in sintering field road cement. Then, the radioactive element distribution characteristics of red mud based field road cement(RFC) before and after hydration were comparatively investigated. The experimental results indicated that the specific activity of ^(226)Ra and ^(232)Th increased after sintering process from raw material to clinker, as a result of concentrating effect on ^(226)Ra and ^(232)Th during sintering process, but the specific activity of ^(40)K decreased after sintering process as a result of volatilization effect. Radionuclide ^(226)Ra mainly distributed in RFC silicate phases(C_xS), ^(232)Th distributed more in RFC interstitial phases than RFC silicate phases(C_xS), ^(40)K mainly distributed in RFC interstitial phases. With increasing hydration ages of RFC pastes, the specific activity of ^(226)Ra kept increasing, ^(232)Th remained consistency all the same and ^(40)K declined. The radioactivity of RFC was in the recommended safe limit of Chinese National Standards GB6566-2010 during its preparation and application process. 展开更多
关键词 red mud distribution radioactivity specific activity cement hydration
原文传递
DEPENDENCE OF THE DISTRIBUTION OF ACTIVE CENTERS ON MONOMER IN SUPPORTED ZIEGLER-NATTA CATALYSTS
11
作者 范志强 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2008年第5期605-610,共6页
Distribution of active centers(ACD)of ethylene or 1-hexene homopolymerization and ethylene-1-hexene copolymerization with a MgCl_2/TiCl_4 type Z-N catalyst were studied by deconvolution of the polymer molecular weight... Distribution of active centers(ACD)of ethylene or 1-hexene homopolymerization and ethylene-1-hexene copolymerization with a MgCl_2/TiCl_4 type Z-N catalyst were studied by deconvolution of the polymer molecular weight distribution into multiple Flory components.Each Flory component is thought to be formed by a certain type of active center. ACD of ethylene-1-hexene copolymer with very low 1-hexene incorporation was compared with that of ethylene homopolymer to see the effect of introducingα-olefin on ethyle... 展开更多
关键词 Supported Ziegler-Natta catalyst Active center distribution Monomer.
在线阅读 下载PDF
Optimal Location and Sizing of Distributed Generator via Improved Multi-Objective Particle Swarm Optimization in Active Distribution Network Considering Multi-Resource
12
作者 Guobin He Rui Su +5 位作者 Jinxin Yang Yuanping Huang Huanlin Chen Donghui Zhang Cangtao Yang Wenwen Li 《Energy Engineering》 EI 2023年第9期2133-2154,共22页
In the framework of vigorous promotion of low-carbon power system growth as well as economic globalization,multi-resource penetration in active distribution networks has been advancing fiercely.In particular,distribut... In the framework of vigorous promotion of low-carbon power system growth as well as economic globalization,multi-resource penetration in active distribution networks has been advancing fiercely.In particular,distributed generation(DG)based on renewable energy is critical for active distribution network operation enhancement.To comprehensively analyze the accessing impact of DG in distribution networks from various parts,this paper establishes an optimal DG location and sizing planning model based on active power losses,voltage profile,pollution emissions,and the economics of DG costs as well as meteorological conditions.Subsequently,multiobjective particle swarm optimization(MOPSO)is applied to obtain the optimal Pareto front.Besides,for the sake of avoiding the influence of the subjective setting of the weight coefficient,the decisionmethod based on amodified ideal point is applied to execute a Pareto front decision.Finally,simulation tests based on IEEE33 and IEEE69 nodes are designed.The experimental results show thatMOPSO can achieve wider and more uniformPareto front distribution.In the IEEE33 node test system,power loss,and voltage deviation decreased by 52.23%,and 38.89%,respectively,while taking the economy into account.In the IEEE69 test system,the three indexes decreased by 19.67%,and 58.96%,respectively. 展开更多
关键词 Active distribution network multi-resource penetration operation enhancement particle swarm optimization multi-objective optimization
在线阅读 下载PDF
Blockchain-Based Power Transaction Method for Active Distribution Network
13
作者 Fei Zeng Zhinong Wei +1 位作者 Haiteng Han Yang Chen 《Energy Engineering》 EI 2023年第5期1067-1080,共14页
A blockchain-based power transaction method is proposed for Active Distribution Network(ADN),considering the poor security and high cost of a centralized power trading system.Firstly,the decentralized blockchain struc... A blockchain-based power transaction method is proposed for Active Distribution Network(ADN),considering the poor security and high cost of a centralized power trading system.Firstly,the decentralized blockchain structure of the ADN power transaction is built and the transaction information is kept in blocks.Secondly,considering the transaction needs between users and power suppliers in ADN,an energy request mechanism is proposed,and the optimization objective function is designed by integrating cost aware requests and storage aware requests.Finally,the particle swarm optimization algorithm is used for multi-objective optimal search to find the power trading scheme with the minimum power purchase cost of users and the maximum power sold by power suppliers.The experimental demonstration of the proposed method based on the experimental platform shows that when the number of participants is no more than 10,the transaction delay time is 0.2 s,and the transaction cost fluctuates at 200,000 yuan,which is better than other comparison methods. 展开更多
关键词 Blockchain active distribution network power transaction energy request mechanism particle swarm optimization algorithm
在线阅读 下载PDF
A Critical Review of Active Distribution Network Reconfiguration:Concepts,Development,and Perspectives
14
作者 Bo Yang Rui Zhang +10 位作者 Jie Zhang Xianlong Cheng Jiale Li Yimin Zhou Yuanweiji Hu Bin He Gongshuai Zhang Xiuping Du Si Ji Yiyan Sang Zhengxun Guo 《Energy Engineering》 EI 2024年第12期3487-3547,共61页
In recent years,the large-scale grid connection of various distributed power sources has made the planning and operation of distribution grids increasingly complex.Consequently,a large number of active distribution ne... In recent years,the large-scale grid connection of various distributed power sources has made the planning and operation of distribution grids increasingly complex.Consequently,a large number of active distribution network reconfiguration techniques have emerged to reduce system losses,improve system safety,and enhance power quality via switching switches to change the system topology while ensuring the radial structure of the network.While scholars have previously reviewed these methods,they all have obvious shortcomings,such as a lack of systematic integration of methods,vague classification,lack of constructive suggestions for future study,etc.Therefore,this paper attempts to provide a comprehensive and profound review of 52 methods and applications of active distribution network reconfiguration through systematic method classification and enumeration.Specifically,these methods are classified into five categories,i.e.,traditional methods,mathematical methods,meta-heuristic algorithms,machine learning methods,and hybrid methods.A thorough comparison of the various methods is also scored in terms of their practicality,complexity,number of switching actions,performance improvement,advantages,and disadvantages.Finally,four summaries and four future research prospects are presented.In summary,this paper aims to provide an up-to-date and well-rounded manual for subsequent researchers and scholars engaged in related fields. 展开更多
关键词 Active distribution network RECONFIGURATION meta-heuristic algorithm machine learning
在线阅读 下载PDF
Robust Voltage Control for Active Distribution Networks via Safe Deep Reinforcement Learning Against State Perturbations
15
作者 Meng Tian Xiaoxu Li +3 位作者 Ziyang Zhu Zhengcheng Dong Li Gong Jingang Lai 《Protection and Control of Modern Power Systems》 2026年第1期192-207,共16页
With the prevalence of renewable distributed energy resources(DERs)such as photovoltaics(PVs),modern active distribution networks(ADNs)suffer from voltage deviation and power quality issues.However,traditional voltage... With the prevalence of renewable distributed energy resources(DERs)such as photovoltaics(PVs),modern active distribution networks(ADNs)suffer from voltage deviation and power quality issues.However,traditional voltage control methods often face a trade-off between efficiency and effectiveness,and rarely ensure robust voltage safety under typical state perturbations in practical distribution grids.In this paper,a robust model-free voltage regulation approach is proposed which simultaneously takes security and robustness into account.In this context,the voltage control problem is formulated as a constrained Markov decision process(CMDP).A safety-augmented multiagent deep deterministic policy gradient(MADDPG)algorithm is the trained to enable real-time collaborative optimization of ADNs,aiming to maintain nodal voltages within safe operational limits while minimizing total line losses.Moreover,a robust regulation loss is introduced to ensure reliable performance under various state perturbations in practical voltage controls.The proposed regulation algorithm effectively balance efficiency,safety,and robustness,and also demonstrates potential for generalizing these characteristics to other applications.Numerical studies vali-date the robustness of the proposed method under varying state perturbations on the IEEE test cases and the optimal integrated control performance when compared to other benchmarks. 展开更多
关键词 Active distribution network robust voltage control state perturbation model-free safe deep reinforcement learning
在线阅读 下载PDF
Multi-Timescale Coordinated Optimal Dispatch of Active Distribution Networks Incorporating Thermal Storage Electric Heating Clusters
16
作者 Song Zhang Yang Yu +1 位作者 Shuguang Li Xue Li 《Energy Engineering》 2026年第3期459-480,共22页
Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energ... Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energy and load forecasting in active distribution networks(ADN),this paper proposes a multi-timescale coordinated optimal dispatch strategy that incorporates TSEH clusters.It utilizes the thermal storage characteristics and short-term regulation capabilities of TSEH,along with the rapid and gradual response characteristics of resources in active distribution grids,to develop a coordinated optimization dispatch mechanism for day-ahead,intraday,and real-time stages.It provides a coordinated optimized dispatch technique across several timescales for active distribution grids,taking into account the integration of TSEH clusters.The proposed method is validated on a modified IEEE 33-node system.Simulation results demonstrate that the participation of TSEH in collaborative optimization significantly reduces the total system operating cost by 8.71%compared to the scenario without TSEH.This cost reduction is attributed to a 10.84%decrease in interaction costs with the main grid and a 47.41%reduction in network loss costs,validating effective peak shaving and valley filling.The multi-timescale framework further enhances economic efficiency,with overall operating costs progressively decreasing by 3.91%(intraday)and 4.59%(real-time),and interaction costs further reduced by 5.34%and 9.25%,respectively.Moreover,the approach enhances system stability by effectively suppressing node voltage fluctuations and ensuring all voltages remain within safe operating limits during real-time operation.Therefore,the proposed approach achieves rational coordination of diverse resources,significantly improving the economic efficiency and stability of ADNs. 展开更多
关键词 Active distribution network thermal storage electric heating distributed energy resources rolling optimization multiple time scales
在线阅读 下载PDF
Low-carbon Joint Planning for Distribution Network Considering Carbon Emission Flow and Uncertainties from Photovoltaic Power Generation
17
作者 Yanlin Li Zhigang Lu +4 位作者 Jiangfeng Zhang Xiaoqiang Guo Xueping Li Xiangxing Kong Jiangyong Zhang 《CSEE Journal of Power and Energy Systems》 2026年第1期411-423,共13页
In order to cope with the global environmental crisis caused by energy generation and achieve carbon neutrality,it is imperative to promote a new power system dominated by renewable energy sources(RESs).This paper foc... In order to cope with the global environmental crisis caused by energy generation and achieve carbon neutrality,it is imperative to promote a new power system dominated by renewable energy sources(RESs).This paper focuses on the uncertainty of RESs and the distribution characteristics of carbon emission flows(CEFs),and studies the low-carbon operation and power system planning problem.Firstly,this paper extends the uncertainty of RES to the meteorological field and establishes meteorological robust constraints of photovoltaic(PV)generation.Based on the CEF theory,the carbon transmission trajectory is accurately delineated to improve the operation of power system.Considering further constraints from the power flow,CEF,and component operation characteristics of the active distribution network(ADN),this paper formulates a low-carbon joint planning model of ADN with PV,battery energy storage system(BESS),and distributed gas generator(DGG),taking into account economy and carbon reduction.In the case study,the low-carbon planning and operation scheme are analyzed in detail across multiple dimensions including time and space.The solution results show that the planning model can effectively leverage the low-carbon performance of PV and BESS,and improve the distribution of CEF.Through case comparison,the model can also efficiently reduce the total cost of the system and enhance carbon emission reduction benefits by 35.10 to 41.04%. 展开更多
关键词 Carbon emission flow joint planning of active distribution network low-carbon operation meteorological robust constraint uncertainty of RES
原文传递
A Pilot Protection Method for Active Distribution Networks Based on Improved Fréchet Distance
18
作者 Xiang Li Guibin Zou +3 位作者 Chenghan Zhou Xincheng Zheng Xinyi Du Zhe Lu 《Protection and Control of Modern Power Systems》 2026年第2期1-15,共15页
The integration of inverter-interfaced distributed generations(IIDGs)has modified the fault characteristics of active distribution networks(ADNs),substantially affecting the range,sensitivity,and reliability of conven... The integration of inverter-interfaced distributed generations(IIDGs)has modified the fault characteristics of active distribution networks(ADNs),substantially affecting the range,sensitivity,and reliability of conventional single-ended protection.Conventional current differential protection and existing waveform similarity-based protection methods suffer from poor tolerance to transition resistance and rely on simulations or field experiences for setting threshold values.To address these problems,this paper proposes a pilot protection method based on improved Fréchet distance by analyzing the differences in amplitude-phase characteristics of short-circuit currents during internal and external faults in ADNs with IIDGs.This method fully considers the physical significance of applying Fréchet distance to power-frequency current waveforms,offering a short operating time,high tolerance to transition resistance,and strong resistance to synchronization errors.Furthermore,a compensation criterion based on the positive-sequence current amplitude of the virtual T-connected branch is established to handle the impact of multiple unmeasurable T-connected branches.PSCAD simulations verify the effectiveness of the proposed method under different fault conditions and demonstrate its improvement over existing methods.Finally,a real-time digital simulator(RTDS)-based hardware test platform is used to further verify the developed differential relay prototypes based on the proposed method. 展开更多
关键词 Active distribution network Fréchet distance pilot protection T-connected branches
在线阅读 下载PDF
North-South Asymmetry of the Interplanetary Magnetic Field Magnitude and the Geomagnetic Indices
19
作者 Mohammed Ali El-Borie Ali Abdel-Moniem Abdel-Halim Shady Yousry El-Monier 《International Journal of Astronomy and Astrophysics》 2016年第1期14-22,共9页
Data of the daily interplanetary magnetic field (IMF), and the geomagnetic indices (aa, Ap, Kp, and DST) have been used to examine the asymmetry between the solar field north and south of the heliospheric current shee... Data of the daily interplanetary magnetic field (IMF), and the geomagnetic indices (aa, Ap, Kp, and DST) have been used to examine the asymmetry between the solar field north and south of the heliospheric current sheet, over the period (1975-2013). It important to note that during the positive polarity epochs: (T) refers to Toward the South of the heliospheric current sheet (Southern Hemisphere), and (A) refers to Away from North of the heliospheric current sheet (Northern Hemisphere). While, during the negative polarity epochs the opposite will be happened. The present study finds no clear indication of the presence of north-south asymmetry in the field magnitude, and also there is no magnetic solar cycle dependence that is evident. During the considered period, the north-south asymmetry for the considered parameters reaches maximum values around the declining phase or near to the minimum of the solar cycle. The geomagnetic indices have a clear asymmetry during the positive solar magnetic polarity period (qA > 0) and have a northern dominance during cycles (22 & 23) and southern dominance during cycles (21 & 24). From the power spectrum density, the considered parameters showed significant peaks which appeared in the north-south asymmetry but the 10.7 yr solar cycle was absent. In addition, the main periodicity of the asymmetry may be 5.2, 4.0 and 3.3 years that exist in the parameters with higher confidence levels. Finally, one can conclude that the asymmetry of the interplanetary parameters and the geomagnetic indices may provide multiple causes for producing the observed asymmetric modulations of cosmic rays. 展开更多
关键词 Geomagnetic Indices Interplanetary Magnetic Field North-South Asymmetry Solar activity distribution
在线阅读 下载PDF
Smart Transformer/Large Flexible Transformer 被引量:7
20
作者 Rongwu Zhu Markus Andresen +5 位作者 Marius Langwasser Marco Liserre Joao Pecas Lopes Carlos Moreira Justino Rodrigues Mario Couto 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期264-274,共11页
Solid-state transformer-based smart transformer(ST)can provide the dc connectivity and advanced services to improve the grid performance and to increase the penetration of the power electronics interfaced resources(e.... Solid-state transformer-based smart transformer(ST)can provide the dc connectivity and advanced services to improve the grid performance and to increase the penetration of the power electronics interfaced resources(e.g.,distributed generators and electric vehicle charging stations)in modern electricity distribution grids.Since the ST is a new and effective paradigm of the electricity grid evolution to well understand the ST,this paper systematically presents the basic architecture and the typical control schemes of the ST and then the advanced services that ST can provide to improve the electricity grids performances in terms of the power flow control,power quality improvement,active damping and active contribution to improve distribution grid resilience by means of enabling autonomous microgrids operation as well as launching a restoration procedure following a general blackout. 展开更多
关键词 Smart Transformer voltage control power quality active distribution grid black start
在线阅读 下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部