期刊文献+
共找到78篇文章
< 1 2 4 >
每页显示 20 50 100
COMPARISON AND EVALUATION OF CURRENT REFERENCE GENERATION STRATEGIES FOR ACTIVE POWER FILTERS IN THREE-PHASE FOUR-WIRE SYSTEMS
1
作者 陈东华 郭涛 +1 位作者 谢少军 周波 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2005年第4期298-306,共9页
For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous act... For three phase four-wire active power filters (APFs), several typical power theories and corresponding current reference generation strategies are induced, p-q, d-q, unify power factor (UPF) and instantaneous active current (IAC) methods are analyzed and compared with each other. The interpretation of active and reactive currents in non-sinusoidal and unbalanced three-phase four-wire systems is given based on the generalized instantaneous reactive power theory. The performance and the characteristic are evaluated, and the application conditions of current reference generation strategies are concluded. Simulation results under different source voltages and loads verify the evaluation result. 展开更多
关键词 active power filters instantaneous reactive power current reference three-phase four wire power
在线阅读 下载PDF
Design and analysis of dual-mode structure repetitive control based hybrid current regulation scheme for active power filters
2
作者 邹志翔 王政 程明 《Journal of Southeast University(English Edition)》 EI CAS 2013年第4期407-413,共7页
An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structu... An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structure repetitive control (DMRC) so that it can offer superior steady-state performance and good transient features. Unlike the conventional schemes, the proposed scheme-based APF can compensate both the odd and the even order harmonics in grid. The detailed design criteria and the stability analysis of the proposed hybrid current controller are presented. Moreover, an improved structure which incorporates the proposed hybrid controller and the resonant controller for tracking specific order harmonics is given. The relationships between the resonant controller and different repetitive control schemes are discussed. Experimental results verify the effectiveness and advantages of the proposed hybrid control scheme. 展开更多
关键词 active power filter dual-mode structure repetitive control (DMRC) current control harmonic compensation resonant controller
在线阅读 下载PDF
Invertebrate community characteristics in biologically active carbon filter 被引量:6
3
作者 Xiaowei Li Yufeng Yang +2 位作者 Lijun Liu Jinsong Zhang Qing Wang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第5期648-655,共8页
Biologically active carbon (BAC) system was set up in a water plant of South China during January to December 2007,to study the invertebrate community characteristics of BAC filter.Thirty-seven invertebrate species ... Biologically active carbon (BAC) system was set up in a water plant of South China during January to December 2007,to study the invertebrate community characteristics of BAC filter.Thirty-seven invertebrate species were found,of which 28 belonging to rotifers.Filter operation could lead to an output of invertebrates in high abundances with the filtrate,and the maximum density could reach 5608 individuals/m 3.Average abundances in the effluent water increased in 27-33 folds in comparison to the influent water during the sampling period.Invertebrate community succession had the following trend:filter-feeding animals → small benthic invertebrates → large benthic and resistant invertebrates.Abundances of large-sized invertebrates (copepod adult and oligochaete) at bigger-media column were significantly higher than that at small-media column.The results implied the abundant species diversity of invertebrate in BAC filter.The relationship between invertebrate and biofilm still remain to be studied in detail. 展开更多
关键词 biologically active carbon filter INVERTEBRATE community characteristics filter media
在线阅读 下载PDF
Carrier phase shifted SPWM based on current sourced multi-modular converter for active power filter 被引量:5
4
作者 王立乔 李建林 张仲超 《Journal of Zhejiang University Science》 EI CSCD 2004年第7期861-866,共6页
A novel current-source active power filter (APF) based on multi-modular converter with carrier phase-shifted SPWM (CPS-SPWM) technique is proposed. With this technique, the effect of equivalent high switching frequenc... A novel current-source active power filter (APF) based on multi-modular converter with carrier phase-shifted SPWM (CPS-SPWM) technique is proposed. With this technique, the effect of equivalent high switching frequency con-verter is obtained with low switching frequency converter. It is very promising in current-source APF that adopt super-conducting magnetic energy storage component. 展开更多
关键词 Current sourced multi-modular converter Carrier phase shifted SPWM active power filter
在线阅读 下载PDF
Simulation Research on a SVPWM Control Algorithm for a Four-Leg Active Power Filter 被引量:5
5
作者 ZHOU Juan WU Xiao-jie GENG Yi-wen DAI Peng 《Journal of China University of Mining and Technology》 EI 2007年第4期590-594,共5页
In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg act... In this paper the topology of a four-leg shunt active-power filter (APF) is given. The APF compensates har-monic and reactive power in a three-phase four-wire system. The scheme adopted for control of the four-leg active power filter,a 3-Dimensional Pulse Width Modulation (PWM) technique,is presented. The theoretical deduction of a space vector PWM (SVPWM) algorithm is given in this paper. The paper also analyzes the distribution of the volt-age-space vector of the four-leg converter in αβγ coordinates and describes methods to determine the location of the voltage-space vector and to calculate duration time. Finally,the algorithm is implemented in simulation; the results show that the total harmonic distortion (THD) of the three phase-current waveforms is reduced. The neutral wire current,after compensation,is about 0 A showing that the topology of the four-leg shunt APF is feasible and the proposed scheme is effective. 展开更多
关键词 three-phase four-wire system shunt active power filter 3-Dimensional space vector PWM
在线阅读 下载PDF
Simulation and reliability analysis of shunt active power filter based on instantaneous reactive power theory 被引量:1
6
作者 CUI Yu-long LIU Hong +1 位作者 WANG Jing-qin SUN Shu-guang 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期416-421,共6页
This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink powe... This paper first discusses the operating principle of instantaneous reactive power theory. Then, the theory is introduced into shunt active power filter and its control scheme is studied. Finally, Matlab/Simulink power system toolbox is used to simulate the system. In the simulation model, as the most common harmonic source, 3-phase thyristor bridge rectifier circuit is constructed. The simulation results before and after the shunt active filter was switched to the system corresponding to different firing angles of the thyristors are presented and analyzed, which demonstrate the practicability and reliability of the proposed shunt active filter scheme. 展开更多
关键词 Shunt active filter Instantaneous reactive power theory HARMONIC 3-phase thyristor bridge rectifier Matlab/ Simulink
在线阅读 下载PDF
DC active power filter based on model predictive control for DC bus overvoltage suppression of accelerator grid power supply 被引量:1
7
作者 张鸿淇 朱帮友 +3 位作者 马少翔 李志恒 张明 潘垣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期1-13,共13页
The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated... The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly. 展开更多
关键词 CFETR NBI accelerator grid power supply power active filter model predictive control
在线阅读 下载PDF
A switchable dual-wavelength erbium-doped fiber laser based on saturable absorber and active optical fiber ring filter 被引量:1
8
作者 祝连庆 陈青山 +2 位作者 赵冉冉 娄小平 何巍 《Optoelectronics Letters》 EI 2014年第6期434-438,共5页
A dual-wavelength erbium-doped fiber laser(EDFL) with outstanding stability is presented. In the fiber laser system, two nested active optical fiber ring filters are configured to improve the comb spectrum performance... A dual-wavelength erbium-doped fiber laser(EDFL) with outstanding stability is presented. In the fiber laser system, two nested active optical fiber ring filters are configured to improve the comb spectrum performance, a saturable absorber is employed to form a gain grating for both filtering and frequency stabilizing, two cascaded fiber Bragg gratings(FBGs) are utilized to achieve dual-wavelength output, and a variable attenuator is arranged to adjust output power. Experimental results illustrate that the peak wavelength drift is less than 3 pm, and a good linear relationship between output power and pump power is realized. 展开更多
关键词 active filters ERBIUM Fiber lasers Fibers Saturable absorbers
原文传递
Implementation of PSOANN Optimized PI Control Algorithm for Shunt Active Filter 被引量:1
9
作者 M.Sujith S.Padma 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第3期863-888,共26页
This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI... This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI),series inductor and DC bus and nonlinear load.The proposed hybrid approach is a combination of Particle Swarm Optimization(PSO)and Artificial Neural Network(ANN)termed as PSOANN.The PI controller gain parameters of kp and ki are optimized with the help of PSOANN.The PSOANN improves the accuracy of tuning the gain parameters under steady and dynamic load conditions;thereby it reduces the values of THD within the prescribed limits of IEEE 519.The PSO optimizes the dataset of terminal voltage and DC voltage present in shunt active filter for different load condition.The optimized dataset acts as the input for the controller to predict the optimal gain with minimal error and to generate the optimized control signal for the SAF.The proposed methodology is modelled and simulated with the help of MATLAB/Simulink platform and illustrated the few test cases considered for exhibiting the performance of proposed hybrid controller.The experimental results are measured with developed laboratory prototype and compared with the simulation results to validate the effectiveness of the proposed control methodology. 展开更多
关键词 Artificial neural network particle swarm optimization shunt active filter voltage source inverter total harmonic distortions.
在线阅读 下载PDF
A novel digital control strategy of three-phase shunt active power filter under non-ideal mains voltages 被引量:1
10
作者 胡志坤 陈志文 +2 位作者 华长春 王会海 丁家峰 《Journal of Central South University》 SCIE EI CAS 2011年第6期2021-2030,共10页
A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous... A novel control strategy for three-phase shunt active power filter (SAPF) was proposed to improve its performance under non-ideal mains voltages. The approach was inspired by our finding that the classic instantaneous reactive power theory based algorithm was unsatisfactory in terms of isolating positive sequence fundamental active components exactly under non-ideal mains voltages. So, a modified ip-iq reference current calculation method was presented. With usage of the new method, not only the positive sequence but also the fundamental active current components can be accurately isolated from load current. A deadbeat closed-loop control model is built in order to eliminate both delay error and tracking error between reference voltages and compensation voltages under unbalanced and distorted mains voltages. Computer simulation results show that the proposed strategy is effective with better tracking ability and lower total harmonic distortion (THD). The strategy is also applied to a 10 kV substation with a local electrolysis manganese plant injecting a large amount of harmonics into the power system, and is proved to be more practical and efficient. 展开更多
关键词 non-ideal mains voltage deadbeat control fundamental positive sequence active current shunt active power filter
在线阅读 下载PDF
Current control for a shunt hybrid active power filter using recursive integral PI 被引量:1
11
作者 Wei ZHAO An LUO Ke PENG Xia DENG 《控制理论与应用(英文版)》 EI 2009年第1期77-80,共4页
This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of d... This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of detection accuracy, time delay of instruction current calculation and phase displacement of output filter. Fuzzy logic based set-point weighing algorithm is combined in the control scheme to enhance its robustness and anti-interference ability. The proposed algorithm is easy to implement for engineering applications and easy to compute. Experiment results have verified the validity of the proposed controller. Furthermore, the proposed recursive integral PI algorithm can also be applied in the control of periodic current as in AC drivers. 展开更多
关键词 Power electronics Shunt hybrid active power filter Recursive integral PI Fuzzy inference
在线阅读 下载PDF
Real-Time Method for Detecting Harmonic and Reactive Currents of Single-Phase Circuits 被引量:1
12
作者 张秀峰 丁菊霞 《Journal of Southwest Jiaotong University(English Edition)》 2006年第2期135-141,共7页
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th... According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize. 展开更多
关键词 active filter HARMONIC Reactive current Real-time detection Single-phase circuit Electric-network
在线阅读 下载PDF
Coordinated Control Strategy for Harmonic Compensation of Multiple Active Power Filters 被引量:1
13
作者 Jianfeng Yang Rende Qi +1 位作者 Yang Liu Yu Ding 《Energy Engineering》 EI 2022年第2期609-620,共12页
In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of acti... In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of active power filters(APF).On the premise of proportional distribution of harmonic compensation capacity,the harmonic compensation rate of each APF is considered,and the harmonic current value of each APF to be compensated is obtained.At the same time,the communication topology is introduced.Each APF takes into account the compensation ability of other APFs.Finally,three APFs with different capacity and performance are configured at the harmonic source to suppress the same harmonic source,and the harmonic distortion rate is reduced to 1.73%.The simulation results show that the strategy can effectively improve the compensation capability of the multiple APF cascaded system to the power grid without increasing the installed capacity. 展开更多
关键词 active power filter collaborative optimization harmonic compensation rate weighting factor communication topology
在线阅读 下载PDF
A 4TH ORDER FULLY INTEGRATED ACTIVE RC COMPLEX FILTER WITH NOVEL AUTOMATIC TUNING SYSTEMS 被引量:1
14
作者 Chen Dianyu Qi Feitao Sun Weiming Qin Shicai Xiong Shaozhen 《Journal of Electronics(China)》 2007年第6期854-858,共5页
This letter introduces a 4th order active RC complex filter with 1.SMHz center frequency and 1MHz bandwidth. The total harmonic distortion of the filter is less than -60dB and the image rejection ratio is greater than... This letter introduces a 4th order active RC complex filter with 1.SMHz center frequency and 1MHz bandwidth. The total harmonic distortion of the filter is less than -60dB and the image rejection ratio is greater than 60dB. A novel technique is also proposed in this letter to automatically adjust the variation of the time constant. The advantages of the proposed method are its high precision and simplicity. Using 5bits control words, the tuning error is less than ±1.6%. 展开更多
关键词 active RC filter Complex filter Automatic tuning system
在线阅读 下载PDF
Control of an Active Filter by Duty Cycle Modulation (DCM) for the Harmonic Decontamination of a Three-Phase Electrical Network 被引量:1
15
作者 Théodore Patrice Nna Nna Salomé Ndjakomo Essiane Stève Pérabi Ngoffé 《Journal of Power and Energy Engineering》 2020年第7期1-14,共14页
This paper presents the control of the active filter by Duty Cycle Modulation (DCM) for the harmonic pollution control of a three-phase electrical system. Several research works have preceded this work, but most of th... This paper presents the control of the active filter by Duty Cycle Modulation (DCM) for the harmonic pollution control of a three-phase electrical system. Several research works have preceded this work, but most of them deal with the control by pulse-width modulation and the differences lie around the THD reduction performance, the quality of the wave obtained, the simplicity of the scheme and the cost of the control. For this purpose, we propose a very innovative approach to active filter control which aims at reducing the current THD at a lower rate than pulse-width modulation techniques improving at the same time the wave quality with a more simplified control scheme. First we present the schematic diagram of the active filter, then we present the design of the control of this active filter based on the real and imaginary instantaneous power method which uses the algebraic “Clark” transformation. The Duty Cycle Modulation controller is used to obtain the required control commands to be injected to the inverter. We then developed a simulink model of the active filter to validate this study. The simulations were performed in the Matlab/Simulink environment. The results obtained show a significant improvement on the harmonic current control techniques for the THD of 1.02% which was 26.25%, the elimination of noise in the signal and the simplicity of the control with an easier implementation than the pulse width modulation (PWM) make the Duty Cycle Modulation (DCM) control a very promising tool. 展开更多
关键词 PWM DCM active Filter INVERTER
暂未订购
Decoupling control and zero dynamics stabilization for shunt hybrid active power filter
16
作者 鲁伟 李春文 《Journal of Central South University》 SCIE EI CAS 2014年第5期1946-1955,共10页
An inverse system method based optimal control strategy was proposed for the shunt hybrid active power filter (SHAPF) to enhance its harmonic elimination performance. Based on the inverse system method, the d-axis a... An inverse system method based optimal control strategy was proposed for the shunt hybrid active power filter (SHAPF) to enhance its harmonic elimination performance. Based on the inverse system method, the d-axis and q-axis current dynamics of the SHAPF system were decoupled and linearized into two pseudolinear subsystems. Then, an optimal feedback controUer was designed for the pseudolinear system, and the stability condition of the resulting zero dynamics was presented. Under the control strategy, the current dynamics can asymptotically converge to their reference states and the zero dynamics can be bounded. Simulation results show that the proposed control strategy is robust against load variations and system parameter mismatches, its steady-state performance is better than that of the traditional linear control strategy. 展开更多
关键词 HARMONICS hybrid active power filter inverse system method optimal control zero dynamics
在线阅读 下载PDF
Lag compensation errors in active power filters based on DSP controllers
17
作者 WANG, Xuedan JIANG, Jianguo GAO, Baichen 《Mining Science and Technology》 EI CAS 2010年第2期312-316,共5页
The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the det... The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the detecting circuits of an active power filter based on DSP control.We derived a mathematical model for the compensation error starting from the error estimation when a single distortion frequency is present.This model was then extended to the case where multiple frequencies are present in the distortion.A formula for a general theory of compensation error with fixed load and fixed lag time is presented.The theoretical analysis and experimental results show that the delay time of an active power filter mainly arises from the sampling time.Lower sampling frequencies introduce larger compensation errors in the active power filter reference current. 展开更多
关键词 active power filter digital signal processing MODELING compensation error
在线阅读 下载PDF
Research on main circuit parameter coupling relationship of single-phase shunt active power filter
18
作者 ZHANG Zi-qi TIAN Ming-xing +1 位作者 SUN Li-jun GAO Yun-bo 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2020年第2期143-151,共9页
There is a certain coupling relationship among the main circuit parameters of a single-phase shunt active power filter(SAPF),which has a great influence on the reasonable selection of various parameter values.By analy... There is a certain coupling relationship among the main circuit parameters of a single-phase shunt active power filter(SAPF),which has a great influence on the reasonable selection of various parameter values.By analyzing the calculation methods of the inductance of alternating current(AC)side and the voltage and capacitance values of direct current(DC)side in the existing single/three-phase SAPF main circuit,a specific single-phase SAPF circuit parameter analytical expression was obtained.Aiming at the coupling relationship among the variables in the resulting expression,the model was optimized and analyzed in MATLAB,and a complete set of parameters design scheme was obtained,which ensure the comprehensive optimization target of the post-harmonic content below 2%is compensated under a specific load.The simulation and experimental procedures verify the correctness of the selected parameters. 展开更多
关键词 shut active power filter(SAPF) coupling relationship parameter design scheme
在线阅读 下载PDF
A Novel Starting Impulse Suppression Method for Active Power Filter Based on Slowly Rising Curve
19
作者 Jianfeng Yang Yu Ding 《Energy Engineering》 EI 2021年第6期1839-1853,共15页
With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,a... With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,and interfering with the normal operation of the power grid.Based on the requirements of harmonic suppression and power system protection,a shunt active power filter(SAPF)is proposed as an effective harmonic suppression method.However,there are problems with impulse current and impulse voltage in the starting process of SAPF.Impulse current and impulse voltage cause the power grid and switchgear to bear greater current stress and voltage stress,which seriously affect the security and reliability of the power grid and may damage the switchgear.To effectively solve the problem of impulse current and impulse voltage,the starting process of SAPF is divided into the uncontrolled rectification stage and the transition stage.The mathematical model of the DC side of APF is established.The causes of impulse current and impulse voltage in the uncontrolled rectifier and transition phases are analyzed.By introducing voltage square,a new starting impulse suppression strategy of active power filter based on the slow rising curve is proposed,fundamentally solving the problems of impulse current and impulse voltage.Simulation results verify the effectiveness and feasibility of this method. 展开更多
关键词 Shunt active power filter starting shock impulse current impulse voltage
在线阅读 下载PDF
Modeling and Controlling of an Active Power Filter Using Photovoltaic System with Reduced Energy Storage Capacitor
20
作者 Tsair-Fwu Lee Homg-Yuan Wu +1 位作者 Chieh Lee Yu Lee 《Journal of Chemistry and Chemical Engineering》 2010年第11期34-43,共10页
A novel three-phase active power filter (APF) circuit with photovoltaic (PV) system to improve the quality of service and to reduce the capacity of energy storage capacitor is presented. The energy balance concept... A novel three-phase active power filter (APF) circuit with photovoltaic (PV) system to improve the quality of service and to reduce the capacity of energy storage capacitor is presented. The energy balance concept and sampling technique were used to simplify the calculation algorithm for the required utility source current and to control the voltage of the energy storage capacitor. The feasibility was verified by using the Pspice simulations and experiments. When the APF mode was used during non-operational period, not only the utilization rate, power factor and power quality could be improved, but also the capacity of energy storage capacitor could sparing. As the results, the advantages of the APF circuit are simplicity of control circuits, low cost, and good transient response. 展开更多
关键词 active power filter sampling energy-storage capacitor harmonic current energy balance.
在线阅读 下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部