The thermal equilibrium state of the reference electrode was investigated. The results show that the temperature difference between the inside and the outside of zirconia tube was very small and the Seebeck effect can...The thermal equilibrium state of the reference electrode was investigated. The results show that the temperature difference between the inside and the outside of zirconia tube was very small and the Seebeck effect can be ignored after the sensor was dipped into liquid steel for more than 2 s. A special sensor was designed to test the relation between the EMF (electromotive force) of sensor and the thermal equilibrium state of the reference elec- trode. Based on these results, it is suggested that the peak in EMF curve was caused by the change of oxygen potential in reference electrode before the thermal equilibrium was reached. If NiO was added by 2 M- 5 M to the Cr/Cr2O3 reference electrode, the peak in EMF curve could be eliminated.展开更多
A novel electrochemical oxygen sensor has been developed by using La beta -Al2O3 as solid electrolyte and Cr+Cr2O3 as reference electrode. The sensor not only can be used as normal oxygen sensor but also as an ultra-l...A novel electrochemical oxygen sensor has been developed by using La beta -Al2O3 as solid electrolyte and Cr+Cr2O3 as reference electrode. The sensor not only can be used as normal oxygen sensor but also as an ultra-low oxygen sensor. Especially, it is very sensitive to measure ultra-low oxygen in molten metal. For estimating the accuracy of La beta -Al2O3 oxygen sensor, two series of oxygen activities in molten iron at different oxygen contents and different temperature were measured by both La beta -Al2O3 oxygen sensor and ZrO2 oxygen sensor. The theoretical values of oxygen activities in molten iron (3.30%C, in mass fraction) at 1723K and 1745K were also evaluated for comparing the measuring results of two sensors. At last, the error of measurement for La beta -Al2O3 oxygen sensor was discussed too.展开更多
The ZrO2 (9mol% Y2O3) coating was prepared evenly on the surface of MgO partially stabilized zirconia (Mg-PSZ) tube (oxygen sensor probe) by dipping the green Mg-PSZ tube in a ZrO2 (9mol% Y2O3) slurry and then co-fir...The ZrO2 (9mol% Y2O3) coating was prepared evenly on the surface of MgO partially stabilized zirconia (Mg-PSZ) tube (oxygen sensor probe) by dipping the green Mg-PSZ tube in a ZrO2 (9mol% Y2O3) slurry and then co-firing at 1750°C for 8 h. The double-cell method was employed to measure the electronic conductivity parameter and exam the reproducibility of the coated Mg- PSZ tube. The experimental results indicate that the good thermal shock resistance of the Mg-PSZ tube can be retained when the coating thickness is not more than 3.4 μm. The ZrO2 (9mol% Y2O3) coating reduces the electronic conductivity parameter remarka- bly, probably due to the lower electronic conductivity of Y2O,-stabilized ZrO2 than that of MgO-stabilized ZrO2. Moreover, the ZrO2 (9mol% Y2O3) coating can improve the reproducibility and accuracy of the Mg-PSZ tube significantly in the low oxygen measure- ment. The smooth surface feature and lower electronic conductivity of the coated Mg-PSZ tube should be responsible for this im- provement.展开更多
(Bi2O3)0.73(Y2O3)0.27 fine powders prepared by wet chemical precipitation method were cold isostatically pressed to form solid electrolyte tubes, and sintered at 900 ℃ for 10 h in the air. Their pumping oxygen ch...(Bi2O3)0.73(Y2O3)0.27 fine powders prepared by wet chemical precipitation method were cold isostatically pressed to form solid electrolyte tubes, and sintered at 900 ℃ for 10 h in the air. Their pumping oxygen characteristics in non-dehydrated Ar gas were investigated, where a ZrO2 (Y2O3 stabilized) oxygen sensor was used to measure the oxygen partial pressure Po2. The results showed that the Po2 value reached magnitudes of 1×10^-2-1×10^-10 Pa at the applied pumping oxygen voltage of 0.5 V, 1×10^-37-1×10^-27 Pa at 1.0 V and 1×10^-53-1×10^47 Pa at 2.0 V within the temperature range from 550 to 650 ℃. Moreover, no cracks were found in the tested solid electrolyte tubes. Thus, the Bi2O3-Y2O3 system might be used in solid electrolyte oxygen pump for purifying gases.展开更多
文摘The thermal equilibrium state of the reference electrode was investigated. The results show that the temperature difference between the inside and the outside of zirconia tube was very small and the Seebeck effect can be ignored after the sensor was dipped into liquid steel for more than 2 s. A special sensor was designed to test the relation between the EMF (electromotive force) of sensor and the thermal equilibrium state of the reference elec- trode. Based on these results, it is suggested that the peak in EMF curve was caused by the change of oxygen potential in reference electrode before the thermal equilibrium was reached. If NiO was added by 2 M- 5 M to the Cr/Cr2O3 reference electrode, the peak in EMF curve could be eliminated.
基金supported by National Natural Science Foundation of China under grant No.59374160.
文摘A novel electrochemical oxygen sensor has been developed by using La beta -Al2O3 as solid electrolyte and Cr+Cr2O3 as reference electrode. The sensor not only can be used as normal oxygen sensor but also as an ultra-low oxygen sensor. Especially, it is very sensitive to measure ultra-low oxygen in molten metal. For estimating the accuracy of La beta -Al2O3 oxygen sensor, two series of oxygen activities in molten iron at different oxygen contents and different temperature were measured by both La beta -Al2O3 oxygen sensor and ZrO2 oxygen sensor. The theoretical values of oxygen activities in molten iron (3.30%C, in mass fraction) at 1723K and 1745K were also evaluated for comparing the measuring results of two sensors. At last, the error of measurement for La beta -Al2O3 oxygen sensor was discussed too.
文摘The ZrO2 (9mol% Y2O3) coating was prepared evenly on the surface of MgO partially stabilized zirconia (Mg-PSZ) tube (oxygen sensor probe) by dipping the green Mg-PSZ tube in a ZrO2 (9mol% Y2O3) slurry and then co-firing at 1750°C for 8 h. The double-cell method was employed to measure the electronic conductivity parameter and exam the reproducibility of the coated Mg- PSZ tube. The experimental results indicate that the good thermal shock resistance of the Mg-PSZ tube can be retained when the coating thickness is not more than 3.4 μm. The ZrO2 (9mol% Y2O3) coating reduces the electronic conductivity parameter remarka- bly, probably due to the lower electronic conductivity of Y2O,-stabilized ZrO2 than that of MgO-stabilized ZrO2. Moreover, the ZrO2 (9mol% Y2O3) coating can improve the reproducibility and accuracy of the Mg-PSZ tube significantly in the low oxygen measure- ment. The smooth surface feature and lower electronic conductivity of the coated Mg-PSZ tube should be responsible for this im- provement.
基金the National Natural Science Foundation of China (50774018)
文摘(Bi2O3)0.73(Y2O3)0.27 fine powders prepared by wet chemical precipitation method were cold isostatically pressed to form solid electrolyte tubes, and sintered at 900 ℃ for 10 h in the air. Their pumping oxygen characteristics in non-dehydrated Ar gas were investigated, where a ZrO2 (Y2O3 stabilized) oxygen sensor was used to measure the oxygen partial pressure Po2. The results showed that the Po2 value reached magnitudes of 1×10^-2-1×10^-10 Pa at the applied pumping oxygen voltage of 0.5 V, 1×10^-37-1×10^-27 Pa at 1.0 V and 1×10^-53-1×10^47 Pa at 2.0 V within the temperature range from 550 to 650 ℃. Moreover, no cracks were found in the tested solid electrolyte tubes. Thus, the Bi2O3-Y2O3 system might be used in solid electrolyte oxygen pump for purifying gases.