期刊文献+
共找到1,345篇文章
< 1 2 68 >
每页显示 20 50 100
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
1
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault Grounding protection zero-sequence current ratio coefficient
在线阅读 下载PDF
Zero-sequence Current Suppressing Strategy for Dual Three-phase Permanent Magnet Synchronous Machines Connected with Single Neutral Point 被引量:3
2
作者 Zongwang Li Yuxuan Du +2 位作者 Jinghua Ji Tao Tao Wenxiang Zhao 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期465-472,共8页
Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM... Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM)strategy to suppress the ZSC.Five vectors are selected as basic voltage vectors in one switching period.The fundamental and harmonic planes and the zero-sequence plane are taken into consideration to synthesis the reference voltage vector.To suppress the ZSC,a non-zero zero-sequence voltage(ZSV)is generated to compensate the third harmonic back-EMF.Rather than triangular carrier modulation,the sawtooth carrier modulation strategy is used to generate asymmetric PWM signals.The modulation range is investigated to explore the variation of modulation range caused by considering the zero-sequence plane.With the proposed method,the ZSC can be considerably reduced.The simulated and experimental results are presented to validate the effectiveness of the proposed modulation strategy. 展开更多
关键词 zero-sequence current a single neutral point dual three-phase permanent-magnet synchronous machine third harmonic back-EMF
在线阅读 下载PDF
Zero-Sequence Current Suppression Strategy for Open-End Winding Permanent Magnet Synchronous Motor Based on Model Predictive Control
3
作者 LIU Huashan LI Jie YAO Fei 《Journal of Donghua University(English Edition)》 EI CAS 2020年第4期286-292,共7页
Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the ... Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the common-mode voltage and the back electromotive force(EMF)harmonic generated by the inverters produce the zero-sequence current in the zero-sequence circuit,and the zero-sequence current has great influence on the operation efficiency and stability of the motor control system.A zero-sequence current suppression strategy is presented based on model predictive current control for OW-PMSM.Through the mathematical model of OW-PMSM to establish the predictive model and the zero-sequence circuit model,the common-mode voltage under different voltage vector combinations is fully considered during vector selection and action time calculation.Then zero-sequence loop constraints are established,so as to suppress the zero-sequence current.In the end,the control strategy proposed in this paper is verified by simulation experiments. 展开更多
关键词 open-end winding permanent magnet synchronous motor(OW-PMSM) zero-sequence current HARMONIC model predictive current control common-mode voltage
在线阅读 下载PDF
SIMULATING METHOD OF MAGNETIZING INRUSH CURRENT OF POWER TRANSFORMERS USING CONCEPT OF INSTANTANEOUS POWER
4
作者 贺家李 段玉倩 《Transactions of Tianjin University》 EI CAS 1999年第1期1-6,共6页
In this paper,a new simulating method is presented,using only the normal magnetizing curve (B-H) of the transformer core material,its geometric dimensions,the no-load power loss data and the concept of instantaneous p... In this paper,a new simulating method is presented,using only the normal magnetizing curve (B-H) of the transformer core material,its geometric dimensions,the no-load power loss data and the concept of instantaneous power. At the end of this paper the simulating calculation using EMTP has been also performed for the same transformer. The comparison shows that the two sets of results are very close to each other,and proves the correctness of the new method. The new method presented in this paper is helpful to verify the correctness of the power transformer design,analyze the behavior of the transformer protection under switching and study the new transformer protection principles. 展开更多
关键词 power transformer magnetizing inrush current remnant flue
在线阅读 下载PDF
An Active Inrush Current Limiter Based on SCR Phase Shift Control for EV Charging Systems 被引量:1
5
作者 Cedric Reymond Sebastien Jacques +1 位作者 Ghafour Benabdelaziz Jean-Charles Lebunetel 《Journal of Energy and Power Engineering》 2016年第4期247-257,共11页
This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium power AC-DC converters (up to 3.7 kW) for electric vehicle charging systems... This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium power AC-DC converters (up to 3.7 kW) for electric vehicle charging systems. In particular, a strategy, based on SCR (silicon controlled rectifier) phase, shift control in a mixed rectifier bridge with diodes and thyristors, is proposed. The challenge is to help designers optimize the triggering delay of SCRs to both limit the peak value of inrush current spikes and optimize the charge duration of the DC-link capacitor. A mathematical model (Mathcad engineering tool) has been defined to point out, the interest of a variable triggering delay to control SCRs to meet the expectations described previously. Experimental measurements using an industrial evaluation board of the AC-DC converter demonstrate the robustness of the method. 展开更多
关键词 EV charger AC-DC converter inrush current limiter SCR phase shift control.
在线阅读 下载PDF
Alternative Approaches for Distinguishing between Faults and Inrush Current in Power Transformers
6
作者 Ahmed M. A. Alomar Bakr E. M. Shamseldin 《Energy and Power Engineering》 2014年第7期143-160,共18页
In this study, we will cover the basic methods used to distinguish between inrush current and fault current in power transformers. First, the nature of inrush current is presented compared to the fault current. Then t... In this study, we will cover the basic methods used to distinguish between inrush current and fault current in power transformers. First, the nature of inrush current is presented compared to the fault current. Then the nature of the magnetizing current due to energizing a power transformer at no-load is explained. The first generation of methods used to disable the protective relay system during inrush current, namely the Desensitizing and Tripping Suppressor, is introduced. The second generation, the harmonic restraint method and the waveform-based restraint method with their different versions, is explained. Then we will explore thoroughly the fictitious equivalent resistance method as an example of the third generation of model type restraining or blocking methods. Finally, a comparison between these methods and conclusion is carried out. 展开更多
关键词 Power Transformer inrush current DIFFERENTIAL RELAY
暂未订购
The Discrimination of Inrush Current from Internal Fault of Power Transformer based on EMD
7
作者 Fanyuan Zeng Qianjin Liu Chao Shi 《Energy and Power Engineering》 2013年第4期1425-1428,共4页
The method is based on that the waveform of the inrush distorts seriously, while the fault current nearly keeps sinusoid. The complicated signal can be decomposed into a finite intrinsic mode functions (IMF) by the EM... The method is based on that the waveform of the inrush distorts seriously, while the fault current nearly keeps sinusoid. The complicated signal can be decomposed into a finite intrinsic mode functions (IMF) by the EMD, then define and compute the projection area on X-axis of each IMF—, the specific gravity of SIMF—, and the maximum of —. We can get a new scheme of transformer-protection based on comparing the difference between inrush and fault current. Theoretical analysis show that the method can precisely discriminate inrush and fault current, fault clearance time is about 20ms. Moreover, it is convenient to achieve and hardly be affect by not-periodic component. 展开更多
关键词 inrush current Transformer PROTECTION HHT EMD IMF
暂未订购
Investigation and Mitigation of Transformer Inrush Current during Black Start of an Independent Power Producer Plant
8
作者 Salman Kahrobaee Marcelo C. Algrain Sohrab Asgarpoor 《Energy and Power Engineering》 2013年第1期1-7,共7页
The energizing of large power transformers has long been considered a critical event in the operation of an electric power system. When a transformer is energized by the utility, a typical inrush current could be as h... The energizing of large power transformers has long been considered a critical event in the operation of an electric power system. When a transformer is energized by the utility, a typical inrush current could be as high as ten times its rated current. This could cause many problems from mechanical stress on transformer windings to harmonics injection, and system protection malfunction. There have been numerous researches focusing on calculation and mitigation of the transformer inrush current. With the development of smart grid, distributed generation from independent power producers (IPPs) is growing rapidly. This paper investigates the inrush current due to black start of an IPP system with several parallel transformers, through a simulation model in DIgSILENT Power Factory software. The study demonstrates that a single genset is capable of energizing a group of transformers since the overall inrush current is slightly above the inrush of the transformer directly connected to the generator. In addition, a simple method is proposed to mitigate the inrush current of the transformers using an auxiliary transformer. 展开更多
关键词 BLACK START Distributed Generation inrush current MITIGATION INDEPENDENT Power PRODUCER Transformer Energizing
暂未订购
Transformer Internal and Inrush Current Fault Detection Using Machine Learning
9
作者 R.Vidhya P.Vanaja Ranjan N.R.Shanker 《Intelligent Automation & Soft Computing》 SCIE 2023年第4期153-168,共16页
Preventive maintenance in the transformer is performed through a dif-ferential relay protection system,and it protects the transformer from internal and external faults.However,the Current Transformer(CT)in the differ... Preventive maintenance in the transformer is performed through a dif-ferential relay protection system,and it protects the transformer from internal and external faults.However,the Current Transformer(CT)in the differential protec-tion system mal-operates during inrush currents.CT saturates due to magnetizing inrush currents and causes false tripping of the differential relays.Moreover,iden-tification of tripping in protection relay either due to inrush current or internal faults needs to be diagnosed.For the above problem,continuous monitoring of transformer breather and CT terminals with thermal camera helps detect the trip-ping in relay due to inrush or internal fault.The transformer’s internal fault leads to high breathing process in the transformer breather,never for inrush currents.During inrush currents,CT temperature is increased.Continuous monitoring of breather and CT of the transformer through thermal imaging and radiometric pix-els detect the causes of CT saturation and differentiates maloperation.Hybrid wavelet threshold image analytics(HWT-IA)based radiometric pixels analysis of the transformer breather and CT after de-noising provides an accurate result of about 95%for identification of the false tripping of differential protection system of transformer. 展开更多
关键词 WAVELET THRESHOLD inrush TRANSFORMER BREATHER current transformer thermal image
在线阅读 下载PDF
Analysis and suppression method of transformer no-load closing excitation inrush current
10
作者 Li Zhengming Chen Yuchen Wang Chengmin 《International English Education Research》 2014年第12期97-99,共3页
The primary winding of the transformer will generate large inrush current due to the saturation of iron core when an unloaded transformer is switched-on. The inrush current not only causes mechanical interaction force... The primary winding of the transformer will generate large inrush current due to the saturation of iron core when an unloaded transformer is switched-on. The inrush current not only causes mechanical interaction force due to which the windings are damaged, but also induces the differential protection relays to operate incorrectly. In this paper, the mathematical model of unloaded single phase transformer in switch-on is analyzed; the computation formulas of the inrush current and its interruption angle are presented. The experiment investigation of single phase transformers with different capacities shows that the inrush current measurement result is consistent with theoretical analysis. The inrush current waveform is typically a steeple top waveform with high order harmonics and damping in one direction. In the same condition, large inrush current amplitude will be induced with smaller switching angle, larger residual flux and smaller saturation flux. 展开更多
关键词 TRANSFORMER Magnetizing impedance Magnetizing inrush current Unload switched-on
在线阅读 下载PDF
柔直孤岛供电系统并网侧和应涌流诱发孤岛侧电压扰动机理及抗扰控制方法
11
作者 雷鸣 胡家睿 +1 位作者 王一振 何晋伟 《天津大学学报(自然科学与工程技术版)》 北大核心 2026年第2期135-145,共11页
针对精密制造工业园区、数据中心等大容量敏感性负荷,采用中压柔直配电技术可提供高品质供电服务.在柔直孤岛供电系统中,并网侧换流变压器发生和应涌流后诱发暂态扰动,可能引起孤岛侧换流变压器饱和以及母线电压畸变,对敏感性负荷高品... 针对精密制造工业园区、数据中心等大容量敏感性负荷,采用中压柔直配电技术可提供高品质供电服务.在柔直孤岛供电系统中,并网侧换流变压器发生和应涌流后诱发暂态扰动,可能引起孤岛侧换流变压器饱和以及母线电压畸变,对敏感性负荷高品质供电造成严重影响.针对以上问题,首先对并网侧换流变压器和应涌流引起换流器直流侧电压电流扰动的机理进行了深入分析,推导了和应涌流直流分量与换流器直流侧基频扰动的关系;随后探讨了直流侧扰动对孤岛侧换流器产生的影响,并阐述了孤岛侧换流变压器饱和以及母线电压畸变的原因.在此基础上,提出了一种孤岛侧母线电压抗扰控制方法.该方法在孤岛侧换流器电压外环和电流内环中增加基频谐振控制器,以抑制孤岛侧换流器交流输出电压中的直流分量,从而防止孤岛侧换流变饱和以及母线电压谐波畸变.所提出的抗扰控制方法无需额外增加硬件设备,具有易于实现、经济性好的优点.最后,利用MATLAB/Simulink仿真软件搭建35 kV/20 MV·A双端柔直孤岛供电系统,对理论分析的正确性和所提抗扰控制方法的有效性进行了验证,仿真结果与理论分析结果的吻合度较好.两种工况下的仿真对比结果表明,采用所提抗扰控制方法可有效抑制孤岛侧换流变压器发生饱和,母线电压总谐波畸变率可降至1%以下. 展开更多
关键词 柔性直流配电 孤岛供电 模块化多电平换流器 和应涌流 抗扰控制
在线阅读 下载PDF
基于CatBoost算法的空载变压器励磁涌流预测
12
作者 郭文 黄著 +1 位作者 周鸣中 王丹翔 《电气传动》 2026年第2期34-42,共9页
空载变压器合闸时产生的励磁涌流可能出现引起设备故障、影响电能质量和导致线路过载等问题,现阶段相控开断是抑制涌流的有效手段,断路器关合特性和剩磁是影响相控精度的主要因素。通过阐述断路器关合特性对励磁涌流的影响,并考虑关合... 空载变压器合闸时产生的励磁涌流可能出现引起设备故障、影响电能质量和导致线路过载等问题,现阶段相控开断是抑制涌流的有效手段,断路器关合特性和剩磁是影响相控精度的主要因素。通过阐述断路器关合特性对励磁涌流的影响,并考虑关合过程中灭弧室内电场变化的不均匀性对关合系数的影响,计算了不同关合系数k对应的预击穿时间。分析了剩磁对励磁涌流的影响机理,利用ATP/EMTP对不同剩磁情况下的励磁涌流做了统计仿真分析。提出一种利用Categorical Boosting(CatBoost)算法预测空载变压器励磁涌流的方法,基于CatBoost算法模型探究断路器关合系数k、机械分散性3σ、剩磁Φ_(r)和励磁涌流之间的映射关系,建立了空载变压器合闸励磁涌流预测模型,此模型可以完成不同相控条件下励磁涌流的预测,同时可以分析不同励磁涌流要求下的断路器性能参数。最后,通过实验验证了CatBoost模型的有效性,通过与其他传统算法对比,验证了其预测的准确性。 展开更多
关键词 相控 励磁涌流 关合特性 剩磁 CatBoost算法
在线阅读 下载PDF
永磁同步电机断电能量回馈的瞬态冲击电流抑制策略
13
作者 蔡孟江 曹鑫 崔强 《航空学报》 北大核心 2026年第4期292-304,共13页
在航空航天领域的磁悬浮电机系统中,悬浮系统的断电保护机制尤为重要。当高速运转的转子因突发断电而脱离主动控制时,悬浮系统中的永磁同步电机(PMSM)须立即切换至能量回馈供电工况以维持悬浮稳定性,但会因电磁耦合引发远超于额定值的... 在航空航天领域的磁悬浮电机系统中,悬浮系统的断电保护机制尤为重要。当高速运转的转子因突发断电而脱离主动控制时,悬浮系统中的永磁同步电机(PMSM)须立即切换至能量回馈供电工况以维持悬浮稳定性,但会因电磁耦合引发远超于额定值的瞬态冲击电流,易造成功率器件击穿,电机绕组绝缘受损等问题。为抑制该冲击电流,提出了一种基于馈电电压轨迹规划的冲击电流抑制策略。通过建立中点钳位(NPC)型三电平变流器驱动的PMSM馈电工况数学模型,揭示了其冲击电流的产生机理,设计了基于轨迹规划的分段给定电压方法。实验结果表明,所提策略在可控切换时间内,使空载与带载冲击电流分别降幅42%和47%。与传统“斜坡”和“S”型规划曲线比,所提基于电压轨迹规划的分段给定方法可在目标电压响应速度与冲击电流幅值抑制这2个相互制约的指标之间取得更优的平衡效果。 展开更多
关键词 永磁同步电机 三电平变流器 工况切换 冲击电流 断电能量回馈
原文传递
风扇和保险丝配合选用案例
14
作者 曾彦彬 张本军 《安全与电磁兼容》 2026年第1期91-94,共4页
风扇的主要部件是电动机,由于其转子和绕组的特性,在启动瞬间或输入电压波动时会产生冲击电流。设计风扇电路时,一般都选用保险丝放在风扇前端,以对风扇进行过流控制。若前端保险丝选用不当,未考虑冲击电流的影响,可能导致意外熔断,进... 风扇的主要部件是电动机,由于其转子和绕组的特性,在启动瞬间或输入电压波动时会产生冲击电流。设计风扇电路时,一般都选用保险丝放在风扇前端,以对风扇进行过流控制。若前端保险丝选用不当,未考虑冲击电流的影响,可能导致意外熔断,进而使散热风扇停转,引发设备持续高温甚至烧毁。因此,选择保险丝时除常规指标外,还需确保其冲击电流能量(热熔值)与后端负载相匹配。 展开更多
关键词 风扇 启动 电压波动 冲击电流 保险丝 热熔值 匹配
在线阅读 下载PDF
杯状横磁和杯状纵磁触头结构真空灭弧室合闸涌流电弧特性研究
15
作者 余勇祥 肖辉 +1 位作者 田溢华 钱伟 《高压电器》 北大核心 2026年第3期16-21,共6页
真空断路器在投切背靠背电容器组时,合闸预击穿过程中的涌流电弧会严重烧蚀真空灭弧室触头表面,被破坏的触头表面会导致分闸过程中高重击穿概率问题。合闸过程中触头自身磁场会对涌流预击穿电弧特性产生影响,是决定重击穿概率的关键因... 真空断路器在投切背靠背电容器组时,合闸预击穿过程中的涌流电弧会严重烧蚀真空灭弧室触头表面,被破坏的触头表面会导致分闸过程中高重击穿概率问题。合闸过程中触头自身磁场会对涌流预击穿电弧特性产生影响,是决定重击穿概率的关键因素。文中旨在研究杯状横纵磁场结构对真空灭弧室容性投切过程中预击穿电弧特性的影响规律。文中分别采用杯状横磁和纵磁结构的真空灭弧室触头开展实验,真空灭弧室的触头直径为48 mm,采用透明玻璃绝缘外壳,内部没有屏蔽罩以便于观察预击穿电弧,实验中利用高速摄像机观察记录涌流预击穿电弧特性。实验结果表明,同等条件下杯状纵磁场比横磁场更能有效降低预击穿涌流电弧对触头表面的烧蚀,从而能提高真空灭弧室的容性电流开断能力。这对解决真空断路器容性开断重击穿问题具有重要意义,也为真空断路器往更高电压等级发展提供技术指导和理论依据。 展开更多
关键词 真空灭弧室 背靠背电容器组 高频涌流 场致发射电流 容性电流投切
在线阅读 下载PDF
Investigation on Transformer Inrush Current in Wind Farms Connected MMC-HVDC Systems
16
作者 Hanwen Wang Yang Wang +2 位作者 Xianyong Xiao Zhiquan Ma Qunwei Xu 《Journal of Modern Power Systems and Clean Energy》 2026年第1期357-367,共11页
The transformer inrush current has been a potential threat in wind farms connected modular multilevel converter based high-voltage direct current (WF-MMC-HVDC) system due to the low overcurrent capability of power ele... The transformer inrush current has been a potential threat in wind farms connected modular multilevel converter based high-voltage direct current (WF-MMC-HVDC) system due to the low overcurrent capability of power electronic devices.To investigate this issue,this paper develops a complete harmonic state space (HSS) model of the WF-MMC-HVDC system containing saturable transformers.The severity of the inrush current is investigated under different transformer configurations and the result is compared with EMTP simulations.More importantly,key factors that influence inrush current characteristics in a WF-MMC-HVDC system are studied using the single-input single-output impedance model derived from the linearized HSS model.The results indicate that wind farms have a minor impact on the inrush current characteristics,whereas V/F controlled modular multilevel converter (MMC) reduces its output voltage during transformer energization,thereby mitigating the severity of the inrush current.The severity of the inrush current largely depends on the resonance point determined by the transmission line.In the case of offshore WF-MMC-HVDC system,long submarine cables may cause severe harmonic amplifications and even do not attenuate for a long time. 展开更多
关键词 Wind farm modular multilevel converter based high-voltage direct current(MMC-HVDC) transformer inrush current harmonic state space(HSS) harmonic resonance
原文传递
某电站升压变充电过程中铁磁谐振的分析和探讨
17
作者 谭斌忠 龙天腾 +3 位作者 王应 何泽胜 张鹏飞 邓锋 《上海大中型电机》 2026年第1期22-26,共5页
升压变铁心存在剩磁时进行充电操作,在励磁涌流和操作电压波动的激励作用下,可能会引发铁磁谐振,对升压变及其相连的电压互感器产生不利影响,降低厂站设备的供电可靠性。本文对某电站升压变充电过程中产生的铁磁谐振现象进行分析,探讨... 升压变铁心存在剩磁时进行充电操作,在励磁涌流和操作电压波动的激励作用下,可能会引发铁磁谐振,对升压变及其相连的电压互感器产生不利影响,降低厂站设备的供电可靠性。本文对某电站升压变充电过程中产生的铁磁谐振现象进行分析,探讨了引发铁磁谐振的可能原因,并提出了避免铁磁谐振产生的应对策略。 展开更多
关键词 升压变 电压互感器 铁磁谐振 剩磁 励磁涌流
在线阅读 下载PDF
纯电动客车辅助控制回路浪涌电流抑制与可靠性提升工程实践——以BMS从控单元继电器粘连故障为例
18
作者 李跃华 石耀民 《城市公共交通》 2026年第1期42-45,共4页
本文针对某型号纯电动客车运行中频繁出现的电池仓排风扇及阀门控制异常问题,开展了一项系统而深入的工程故障分析与改进研究。通过现场故障件测试、模块拆解分析以及实车电流波形捕捉,最终确定故障根源为BMS从控单元内部输出继电器的... 本文针对某型号纯电动客车运行中频繁出现的电池仓排风扇及阀门控制异常问题,开展了一项系统而深入的工程故障分析与改进研究。通过现场故障件测试、模块拆解分析以及实车电流波形捕捉,最终确定故障根源为BMS从控单元内部输出继电器的触点粘连。关键试验数据表明,该故障的诱因在于电池仓阀门负载启动瞬间产生的浪涌电流远超技术协议规定。据此从系统架构设计、器件选型与负载匹配等层面提出“取消BMS从控模块对高浪涌负载直接控制”的工程解决方案,为电驱动客车低压辅助控制系统中继电器选型、负载特性识别与可靠性设计提供了具有实践价值的参考。 展开更多
关键词 纯电动客车 BMS 从控单元 继电器粘连 浪涌电流
在线阅读 下载PDF
大型耙吸挖泥船变压器励磁涌流抑制研究
19
作者 佘青青 《船电技术》 2026年第4期39-43,共5页
本文首先阐述变压器励磁涌流产生原因及串接小容量变压器预充磁原理,针对大型耙吸挖泥船变压器数量多、分区运行特点,提出从主变压器原边接预充磁电源、副边串小容量变压器的抑制方案,该方案可保证充磁与主电源同源,且减少对主变压器及... 本文首先阐述变压器励磁涌流产生原因及串接小容量变压器预充磁原理,针对大型耙吸挖泥船变压器数量多、分区运行特点,提出从主变压器原边接预充磁电源、副边串小容量变压器的抑制方案,该方案可保证充磁与主电源同源,且减少对主变压器及配电板尺寸的影响。接着分析预充磁变压器容量整定方法,通过Simulink建模对比不同预充磁时长下的涌流幅值以优化时间。仿真验算结果表明,该方案能有效抑制此类船舶变压器励磁涌流,可为同类船舶相关设计提供参考。 展开更多
关键词 大型耙吸挖泥船 变压器 涌流抑制 SIMULINK仿真
在线阅读 下载PDF
Suppressing Dual Zero-sequence Current in Dual Three-phase Open-winding PMSM Using Multi-zero-vectors Hysteresis Control
20
作者 Qiang Zhang Wenxiang Zhao +1 位作者 Tao Tao Zongwang Li 《Chinese Journal of Electrical Engineering》 2025年第3期167-177,共11页
In a dual three-phase open-winding permanent magnet synchronous motor(DTP-OW-PMSM)system sharing a common DC bus,dual zero-sequence current(ZSC)loops are inherent,leading to increased inverter capacity usage,losses,an... In a dual three-phase open-winding permanent magnet synchronous motor(DTP-OW-PMSM)system sharing a common DC bus,dual zero-sequence current(ZSC)loops are inherent,leading to increased inverter capacity usage,losses,and degraded operational performance.To mitigate ZSC,the dual zero-sequence equivalent circuit of the DTP-OW-PMSM system is established,and zero-vector combinations with significant zero-sequence voltage amplitudes are employed.Since the two sets of ZSC loops are independent,four zero-vector combinations can be determined.A ZSC suppression strategy utilizing hysteresis controllers is proposed.Compared with the PI controller,hysteresis controllers offer wider bandwidth and simplify control parameter tuning.Additionally,180-degree decoupling streamlines vector selection for multiphase open-winding topologies.Furthermore,the modulation range of the proposed strategy is investigated.Finally,experiment in a direct-drive motor is implemented,and experimental results confirming its effectiveness. 展开更多
关键词 Dual three-phase open-winding permanent magnet synchronous motor zero-sequence current hysteresis controller zero-vector combinations
原文传递
上一页 1 2 68 下一页 到第
使用帮助 返回顶部