Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightni...Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightning electromagnetic pulses.In this study,using capacitive and resistive dividers,current probes and optical fiber transmission devices,we measured and analyzed the induced overvoltage on the overhead transmission line and the overcurrent through Surge Protective Devices(SPD) when a lightning discharge was artificially triggered nearby on August 12,2008 at Conghua Field Lightning Experiment Site.The triggered lightning discharge contained an initial current stage and eight return strokes whose peak currents ranged from 6.6kA to 26.4kA.We found that overcurrents through SPD were induced on the power line both during the initial continuous current stage and the return stroke processes.During the return strokes,the residual voltage and the current through the SPD lasted up to the ms(millisecond) range,and the overcurrents exhibited a mean waveform up to 22/69μs with a peak value of less than 2kA.Based on the observed data,simple calculations show that the corresponding single discharge energy was much greater than the values of the high voltage pulse generators commonly used in the experiments regulated for SPD.The SPD discharge current peak was not synchronous to that of the residual voltage with the former obviously lagging behind the latter.The SPD discharge current peak was well correlated with the triggered lightning current peak and the wave-front current gradient.The long duration of the SPD current is one of the major reasons why the SPD was damaged even with a big nominal discharge current.展开更多
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei...Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs.展开更多
The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type r...The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type relay is proposed. The setting of the trip time for this relay is performed by determining the shortest trip time and the longest trip time, respectively. The results of analysis show that with the new time function, the inverse-time overcurrent relay is easy to coordinate with other relays and has a comparatively shorter trip time, and that the fault happens in the protective zone.展开更多
Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM...Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM)strategy to suppress the ZSC.Five vectors are selected as basic voltage vectors in one switching period.The fundamental and harmonic planes and the zero-sequence plane are taken into consideration to synthesis the reference voltage vector.To suppress the ZSC,a non-zero zero-sequence voltage(ZSV)is generated to compensate the third harmonic back-EMF.Rather than triangular carrier modulation,the sawtooth carrier modulation strategy is used to generate asymmetric PWM signals.The modulation range is investigated to explore the variation of modulation range caused by considering the zero-sequence plane.With the proposed method,the ZSC can be considerably reduced.The simulated and experimental results are presented to validate the effectiveness of the proposed modulation strategy.展开更多
The IGBT protection techniques applied in the design of inverter are proposed.Effective protection circuits are developed according to various conditions of overcurrent.Fast overcurrent protection circuit should be us...The IGBT protection techniques applied in the design of inverter are proposed.Effective protection circuits are developed according to various conditions of overcurrent.Fast overcurrent protection circuit should be used widely, so as to ensure reliableoperation of IGBT inverter.展开更多
This paper presents an integrated protection technique for power distribution systems. A novel integrated protection scheme based on overcurrent protection technique for distribution system is described, in which a sp...This paper presents an integrated protection technique for power distribution systems. A novel integrated protection scheme based on overcurrent protection technique for distribution system is described, in which a specially designed protection relay is installed at each substation of a network and responsible for the protection of every line sections connected to the substation busbar The conventional directional overcurrent and the new adaptive accelerated protection algorithms with multiple settings are implemented into the relay to cover all the protected line sections. The paper includes studies of a typical multi section distribution network to demonstrate the principle of the scheme. Studies show that the new scheme not only offer the new protection features for individual power line section, but also provide the characteristics of integrated protection.展开更多
For the development of distributed power supply active distribution network system, the instability of the power supply side causes the system frequency to be disturbed, and harmonics, voltage fluctuations, or ferroma...For the development of distributed power supply active distribution network system, the instability of the power supply side causes the system frequency to be disturbed, and harmonics, voltage fluctuations, or ferromagnetic saturation causes resonance and other series of power quality problems;what resulting in the over-voltage and over-current can easily damage components and threaten the system's safe and stable operation. In order to solve these problems, this paper compares some harmonic detection and filtering methods, devices and methods for suppressing resonance in recent years, and combines the principle of resonance to design a nonlinear inductive circuit that can suppress resonant overcurrent according to the characteristics of nonlinear inductors. Compared with the Resistance (R) series Induct Capacitance (LC) parallel circuit composed of common inductors, the circuit described in this paper is not affected by overcurrent, and the influence of overvoltage is relatively greatly reduced. The simulate-on proves that this circuit suppresses the effects of resonant overvoltage and overcurrent.展开更多
The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integra...The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integrated protection equipment, OC protection setting table must be converted to be a microcomputer algorithm. This paper first intro-duced a method of the fitting OC protection setting table to be OC relay inverse time characteristics equations using MATLAB least square fitting. On the basis of analyzing these fitting equations, a notion, “integral limit rate” was put forward initially and a OC in-verse time digital algorithm was developed. MATLAB simulation results and a digital signal processor (DSP) based digital integrated protection equipment running test indicate that this algorithm has less calculation amount, less taking up memory, high control accuracy, implements the no-grade setting of OC delay values, suits for all kinds of low-middle mi-crocomputer system implementation.展开更多
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground...The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.展开更多
Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the ...Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the common-mode voltage and the back electromotive force(EMF)harmonic generated by the inverters produce the zero-sequence current in the zero-sequence circuit,and the zero-sequence current has great influence on the operation efficiency and stability of the motor control system.A zero-sequence current suppression strategy is presented based on model predictive current control for OW-PMSM.Through the mathematical model of OW-PMSM to establish the predictive model and the zero-sequence circuit model,the common-mode voltage under different voltage vector combinations is fully considered during vector selection and action time calculation.Then zero-sequence loop constraints are established,so as to suppress the zero-sequence current.In the end,the control strategy proposed in this paper is verified by simulation experiments.展开更多
This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be dimin...This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be diminished using electromagnetic devices, particularly the eZSB (electromagnetic zero-sequence blocking). One important characteristic of this device, which has received particular attention on this research, is its robustness and low cost of construction. Theoretical and experimental results related to the behavior of the electromagnetic blocking devices are presented. The results illustrate the consistence of the theoretical aspects related with the model in the frequency domain, as well as the performance of the blocking devices, reducing zero-sequence harmonic currents, mainly by the conjunct action of the eZSF (electromagnetic zero-sequence harmonic filter), working as a impedance coupler. In this context, aiming the evaluation of the reliability of the results obtained through mathematical modeling, experimental tests have been carried out using a low-power prototype, highlighting particular aspects related to its function as a zero-sequence harmonic blocker.展开更多
As we all know, substation operation requires knowledge of different disciplines. In order to ensure the safety of substation operation and improve its operation efficiency, the negligence of details will cause seriou...As we all know, substation operation requires knowledge of different disciplines. In order to ensure the safety of substation operation and improve its operation efficiency, the negligence of details will cause serious potential safety hazards in a specific environment or at a specific time, which may lead to safety accidents. In order to improve the overall efficiency and quality of substation operation, the overcurrent protection in complex voltage direction of Substation operation is briefly discussed.展开更多
基金A key project of China Meteorological Administration (CMATG2008Z07)Specialized Science Project for Public Welfare Industries (GYHY2007622)Key Science Project of the Guangzhou Regional Meteorological Center (GRMC2007B03)
文摘Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightning electromagnetic pulses.In this study,using capacitive and resistive dividers,current probes and optical fiber transmission devices,we measured and analyzed the induced overvoltage on the overhead transmission line and the overcurrent through Surge Protective Devices(SPD) when a lightning discharge was artificially triggered nearby on August 12,2008 at Conghua Field Lightning Experiment Site.The triggered lightning discharge contained an initial current stage and eight return strokes whose peak currents ranged from 6.6kA to 26.4kA.We found that overcurrents through SPD were induced on the power line both during the initial continuous current stage and the return stroke processes.During the return strokes,the residual voltage and the current through the SPD lasted up to the ms(millisecond) range,and the overcurrents exhibited a mean waveform up to 22/69μs with a peak value of less than 2kA.Based on the observed data,simple calculations show that the corresponding single discharge energy was much greater than the values of the high voltage pulse generators commonly used in the experiments regulated for SPD.The SPD discharge current peak was not synchronous to that of the residual voltage with the former obviously lagging behind the latter.The SPD discharge current peak was well correlated with the triggered lightning current peak and the wave-front current gradient.The long duration of the SPD current is one of the major reasons why the SPD was damaged even with a big nominal discharge current.
基金supported in part by National Key Research and Development Program of China(2016YFB0900603)Technology Projects of State Grid Corporation of China(52094017000W).
文摘Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs.
基金TheNationalNaturalScienceFoundationofChina (No .6 9774 0 2 4 )
文摘The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type relay is proposed. The setting of the trip time for this relay is performed by determining the shortest trip time and the longest trip time, respectively. The results of analysis show that with the new time function, the inverse-time overcurrent relay is easy to coordinate with other relays and has a comparatively shorter trip time, and that the fault happens in the protective zone.
基金supported in part by the National Natural Science Foundation of China under Grant 51977099。
文摘Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM)strategy to suppress the ZSC.Five vectors are selected as basic voltage vectors in one switching period.The fundamental and harmonic planes and the zero-sequence plane are taken into consideration to synthesis the reference voltage vector.To suppress the ZSC,a non-zero zero-sequence voltage(ZSV)is generated to compensate the third harmonic back-EMF.Rather than triangular carrier modulation,the sawtooth carrier modulation strategy is used to generate asymmetric PWM signals.The modulation range is investigated to explore the variation of modulation range caused by considering the zero-sequence plane.With the proposed method,the ZSC can be considerably reduced.The simulated and experimental results are presented to validate the effectiveness of the proposed modulation strategy.
文摘The IGBT protection techniques applied in the design of inverter are proposed.Effective protection circuits are developed according to various conditions of overcurrent.Fast overcurrent protection circuit should be used widely, so as to ensure reliableoperation of IGBT inverter.
文摘This paper presents an integrated protection technique for power distribution systems. A novel integrated protection scheme based on overcurrent protection technique for distribution system is described, in which a specially designed protection relay is installed at each substation of a network and responsible for the protection of every line sections connected to the substation busbar The conventional directional overcurrent and the new adaptive accelerated protection algorithms with multiple settings are implemented into the relay to cover all the protected line sections. The paper includes studies of a typical multi section distribution network to demonstrate the principle of the scheme. Studies show that the new scheme not only offer the new protection features for individual power line section, but also provide the characteristics of integrated protection.
文摘For the development of distributed power supply active distribution network system, the instability of the power supply side causes the system frequency to be disturbed, and harmonics, voltage fluctuations, or ferromagnetic saturation causes resonance and other series of power quality problems;what resulting in the over-voltage and over-current can easily damage components and threaten the system's safe and stable operation. In order to solve these problems, this paper compares some harmonic detection and filtering methods, devices and methods for suppressing resonance in recent years, and combines the principle of resonance to design a nonlinear inductive circuit that can suppress resonant overcurrent according to the characteristics of nonlinear inductors. Compared with the Resistance (R) series Induct Capacitance (LC) parallel circuit composed of common inductors, the circuit described in this paper is not affected by overcurrent, and the influence of overvoltage is relatively greatly reduced. The simulate-on proves that this circuit suppresses the effects of resonant overvoltage and overcurrent.
文摘The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integrated protection equipment, OC protection setting table must be converted to be a microcomputer algorithm. This paper first intro-duced a method of the fitting OC protection setting table to be OC relay inverse time characteristics equations using MATLAB least square fitting. On the basis of analyzing these fitting equations, a notion, “integral limit rate” was put forward initially and a OC in-verse time digital algorithm was developed. MATLAB simulation results and a digital signal processor (DSP) based digital integrated protection equipment running test indicate that this algorithm has less calculation amount, less taking up memory, high control accuracy, implements the no-grade setting of OC delay values, suits for all kinds of low-middle mi-crocomputer system implementation.
基金This paper is supported in part by the National Natural Science Foundations of China,and the Major Science and Technology Projects in Yunnan Province under Grant Nos.51667010,51807085,and 202002AF080001.
文摘The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.
基金Fundamental Research Funds for the Central Universities,China(No.2232019D3-53)Initial Research Funds for Young Teachers of Donghua University,China(104070053029)Shanghai Rising-Star Program,China(No.19QA1400400)。
文摘Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the common-mode voltage and the back electromotive force(EMF)harmonic generated by the inverters produce the zero-sequence current in the zero-sequence circuit,and the zero-sequence current has great influence on the operation efficiency and stability of the motor control system.A zero-sequence current suppression strategy is presented based on model predictive current control for OW-PMSM.Through the mathematical model of OW-PMSM to establish the predictive model and the zero-sequence circuit model,the common-mode voltage under different voltage vector combinations is fully considered during vector selection and action time calculation.Then zero-sequence loop constraints are established,so as to suppress the zero-sequence current.In the end,the control strategy proposed in this paper is verified by simulation experiments.
文摘This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be diminished using electromagnetic devices, particularly the eZSB (electromagnetic zero-sequence blocking). One important characteristic of this device, which has received particular attention on this research, is its robustness and low cost of construction. Theoretical and experimental results related to the behavior of the electromagnetic blocking devices are presented. The results illustrate the consistence of the theoretical aspects related with the model in the frequency domain, as well as the performance of the blocking devices, reducing zero-sequence harmonic currents, mainly by the conjunct action of the eZSF (electromagnetic zero-sequence harmonic filter), working as a impedance coupler. In this context, aiming the evaluation of the reliability of the results obtained through mathematical modeling, experimental tests have been carried out using a low-power prototype, highlighting particular aspects related to its function as a zero-sequence harmonic blocker.
文摘As we all know, substation operation requires knowledge of different disciplines. In order to ensure the safety of substation operation and improve its operation efficiency, the negligence of details will cause serious potential safety hazards in a specific environment or at a specific time, which may lead to safety accidents. In order to improve the overall efficiency and quality of substation operation, the overcurrent protection in complex voltage direction of Substation operation is briefly discussed.