CHARACTERISTICS ANALYSIS OF THE INDUCED OVERCURRENT GENERATED BY CLOSE TRIGGERED LIGHTNING ON THE OVERHEAD TRANSMISSION POWER LINE 被引量:8
1
作者 杨少杰 陈绍东 +5 位作者 张义军 董万胜 王建国 周蜜 王孝波 余晖 《Journal of Tropical Meteorology》 SCIE 2010年第1期59-65,共7页
Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightni... Techniques of artificially-triggered lightning have provided a significantly useful means to directly measure various physical parameters of lightning discharge and to conduct research on protection methods of lightning electromagnetic pulses.In this study,using capacitive and resistive dividers,current probes and optical fiber transmission devices,we measured and analyzed the induced overvoltage on the overhead transmission line and the overcurrent through Surge Protective Devices(SPD) when a lightning discharge was artificially triggered nearby on August 12,2008 at Conghua Field Lightning Experiment Site.The triggered lightning discharge contained an initial current stage and eight return strokes whose peak currents ranged from 6.6kA to 26.4kA.We found that overcurrents through SPD were induced on the power line both during the initial continuous current stage and the return stroke processes.During the return strokes,the residual voltage and the current through the SPD lasted up to the ms(millisecond) range,and the overcurrents exhibited a mean waveform up to 22/69μs with a peak value of less than 2kA.Based on the observed data,simple calculations show that the corresponding single discharge energy was much greater than the values of the high voltage pulse generators commonly used in the experiments regulated for SPD.The SPD discharge current peak was not synchronous to that of the residual voltage with the former obviously lagging behind the latter.The SPD discharge current peak was well correlated with the triggered lightning current peak and the wave-front current gradient.The long duration of the SPD current is one of the major reasons why the SPD was damaged even with a big nominal discharge current. 展开更多
关键词 triggered lightning overhead transmission line SPD induced overcurrent
在线阅读 下载PDF
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
2
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault Grounding protection zero-sequence current ratio coefficient
在线阅读 下载PDF
A New Proposal of Inverse-Time Characteristics for Overcurrent Relay Based on Microcomputer 被引量:1
3
作者 黄彦全 肖建 +1 位作者 蔡勇 唐磊 《Journal of Southwest Jiaotong University(English Edition)》 2004年第1期25-28,共4页
The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type r... The conventional time function of electromechanical relays is hard to coordinate with other relays. In order to promote the application of inverse-time overcurrent relays, a new time function for microprocessor-type relay is proposed. The setting of the trip time for this relay is performed by determining the shortest trip time and the longest trip time, respectively. The results of analysis show that with the new time function, the inverse-time overcurrent relay is easy to coordinate with other relays and has a comparatively shorter trip time, and that the fault happens in the protective zone. 展开更多
关键词 Dial setting Inverse-time characteristics overcurrent relays Coordination
在线阅读 下载PDF
Zero-sequence Current Suppressing Strategy for Dual Three-phase Permanent Magnet Synchronous Machines Connected with Single Neutral Point 被引量:3
4
作者 Zongwang Li Yuxuan Du +2 位作者 Jinghua Ji Tao Tao Wenxiang Zhao 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期465-472,共8页
Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM... Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM)strategy to suppress the ZSC.Five vectors are selected as basic voltage vectors in one switching period.The fundamental and harmonic planes and the zero-sequence plane are taken into consideration to synthesis the reference voltage vector.To suppress the ZSC,a non-zero zero-sequence voltage(ZSV)is generated to compensate the third harmonic back-EMF.Rather than triangular carrier modulation,the sawtooth carrier modulation strategy is used to generate asymmetric PWM signals.The modulation range is investigated to explore the variation of modulation range caused by considering the zero-sequence plane.With the proposed method,the ZSC can be considerably reduced.The simulated and experimental results are presented to validate the effectiveness of the proposed modulation strategy. 展开更多
关键词 zero-sequence current a single neutral point dual three-phase permanent-magnet synchronous machine third harmonic back-EMF
在线阅读 下载PDF
IGBT Overcurrent Protection of Welding Inverter Power Source
5
作者 殷树言 耿正 +1 位作者 邵宏 郭大勇 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1996年第1期83-89,共7页
The IGBT protection techniques applied in the design of inverter are proposed.Effective protection circuits are developed according to various conditions of overcurrent.Fast overcurrent protection circuit should be us... The IGBT protection techniques applied in the design of inverter are proposed.Effective protection circuits are developed according to various conditions of overcurrent.Fast overcurrent protection circuit should be used widely, so as to ensure reliableoperation of IGBT inverter. 展开更多
关键词 ss: IGBT overcurrent PROTECTION INVERTER
在线阅读 下载PDF
Simulation Studies of an Integrated Overcurrent Relay Protection Scheme for Distribution Systems 被引量:2
6
作者 Z.Q. Bo X.Z. Dong +1 位作者 B.H. Zhang J.H. He 《Journal of Energy and Power Engineering》 2011年第1期55-62,共8页
This paper presents an integrated protection technique for power distribution systems. A novel integrated protection scheme based on overcurrent protection technique for distribution system is described, in which a sp... This paper presents an integrated protection technique for power distribution systems. A novel integrated protection scheme based on overcurrent protection technique for distribution system is described, in which a specially designed protection relay is installed at each substation of a network and responsible for the protection of every line sections connected to the substation busbar The conventional directional overcurrent and the new adaptive accelerated protection algorithms with multiple settings are implemented into the relay to cover all the protected line sections. The paper includes studies of a typical multi section distribution network to demonstrate the principle of the scheme. Studies show that the new scheme not only offer the new protection features for individual power line section, but also provide the characteristics of integrated protection. 展开更多
关键词 overcurrent protection integrated protection centralized protection network protection digital substation powersystem simulation.
在线阅读 下载PDF
Simulation Analysis of Suppression of Resonant Overcurrent by Nonlinear Components
7
作者 Qiyang Xia Haiming Li Yong Wang 《Journal of Computer and Communications》 2018年第11期264-275,共12页
For the development of distributed power supply active distribution network system, the instability of the power supply side causes the system frequency to be disturbed, and harmonics, voltage fluctuations, or ferroma... For the development of distributed power supply active distribution network system, the instability of the power supply side causes the system frequency to be disturbed, and harmonics, voltage fluctuations, or ferromagnetic saturation causes resonance and other series of power quality problems;what resulting in the over-voltage and over-current can easily damage components and threaten the system's safe and stable operation. In order to solve these problems, this paper compares some harmonic detection and filtering methods, devices and methods for suppressing resonance in recent years, and combines the principle of resonance to design a nonlinear inductive circuit that can suppress resonant overcurrent according to the characteristics of nonlinear inductors. Compared with the Resistance (R) series Induct Capacitance (LC) parallel circuit composed of common inductors, the circuit described in this paper is not affected by overcurrent, and the influence of overvoltage is relatively greatly reduced. The simulate-on proves that this circuit suppresses the effects of resonant overvoltage and overcurrent. 展开更多
关键词 Power Quality RESONANCE NONLINEAR INDUCTANCE SUPPRESSION of overcurrent
暂未订购
MATLAB fitting for overcurrent relay and a new digital algorithm study
8
作者 张小鸣 《Journal of Coal Science & Engineering(China)》 2005年第2期90-94,共5页
The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integra... The overcurrent (OC) protection limit is set usually accorging to a OC protection setting table on digital integrated protection equipment in mine explode isolation high voltage (HV) vacuum switch. For digital integrated protection equipment, OC protection setting table must be converted to be a microcomputer algorithm. This paper first intro-duced a method of the fitting OC protection setting table to be OC relay inverse time characteristics equations using MATLAB least square fitting. On the basis of analyzing these fitting equations, a notion, “integral limit rate” was put forward initially and a OC in-verse time digital algorithm was developed. MATLAB simulation results and a digital signal processor (DSP) based digital integrated protection equipment running test indicate that this algorithm has less calculation amount, less taking up memory, high control accuracy, implements the no-grade setting of OC delay values, suits for all kinds of low-middle mi-crocomputer system implementation. 展开更多
关键词 overcurrent relay inverse time FIT integral limit
在线阅读 下载PDF
Protection of Zero-Sequence Power Variation in Mountain Wind Farm Collector Lines Based on Multi-Mode Grounding
9
作者 Hongchun Shu Yaqi Deng +3 位作者 Pulin Cao Jun Dong Hongjiang Rao Zhiqian Bo 《Energy Engineering》 EI 2022年第2期523-538,共16页
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground... The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability. 展开更多
关键词 Mountain wind farm multi-mode grounding collector line single-phase grounding fault zero-sequence power variation
在线阅读 下载PDF
Zero-Sequence Current Suppression Strategy for Open-End Winding Permanent Magnet Synchronous Motor Based on Model Predictive Control
10
作者 LIU Huashan LI Jie YAO Fei 《Journal of Donghua University(English Edition)》 EI CAS 2020年第4期286-292,共7页
Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the ... Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the common-mode voltage and the back electromotive force(EMF)harmonic generated by the inverters produce the zero-sequence current in the zero-sequence circuit,and the zero-sequence current has great influence on the operation efficiency and stability of the motor control system.A zero-sequence current suppression strategy is presented based on model predictive current control for OW-PMSM.Through the mathematical model of OW-PMSM to establish the predictive model and the zero-sequence circuit model,the common-mode voltage under different voltage vector combinations is fully considered during vector selection and action time calculation.Then zero-sequence loop constraints are established,so as to suppress the zero-sequence current.In the end,the control strategy proposed in this paper is verified by simulation experiments. 展开更多
关键词 open-end winding permanent magnet synchronous motor(OW-PMSM) zero-sequence current HARMONIC model predictive current control common-mode voltage
在线阅读 下载PDF
Electromagnetic Zero-Sequence Harmonics Blocker: Modeling and Experimental Analysis
11
作者 Luis C. Origa de Oliveira Rodrigo N. de Oliveira +1 位作者 Julio B. de Souza Stefani C. L. de Freitas 《Journal of Energy and Power Engineering》 2014年第8期1425-1431,共7页
This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be dimin... This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be diminished using electromagnetic devices, particularly the eZSB (electromagnetic zero-sequence blocking). One important characteristic of this device, which has received particular attention on this research, is its robustness and low cost of construction. Theoretical and experimental results related to the behavior of the electromagnetic blocking devices are presented. The results illustrate the consistence of the theoretical aspects related with the model in the frequency domain, as well as the performance of the blocking devices, reducing zero-sequence harmonic currents, mainly by the conjunct action of the eZSF (electromagnetic zero-sequence harmonic filter), working as a impedance coupler. In this context, aiming the evaluation of the reliability of the results obtained through mathematical modeling, experimental tests have been carried out using a low-power prototype, highlighting particular aspects related to its function as a zero-sequence harmonic blocker. 展开更多
关键词 Electromagnetic blocker zero-sequence harmonics triplens harmonics power quality
在线阅读 下载PDF
Discussion on Overcurrent Protection in Complex Voltage Direction during Substation Operation
12
作者 LYU Jinsheng 《外文科技期刊数据库(文摘版)工程技术》 2021年第10期1113-1116,共6页
As we all know, substation operation requires knowledge of different disciplines. In order to ensure the safety of substation operation and improve its operation efficiency, the negligence of details will cause seriou... As we all know, substation operation requires knowledge of different disciplines. In order to ensure the safety of substation operation and improve its operation efficiency, the negligence of details will cause serious potential safety hazards in a specific environment or at a specific time, which may lead to safety accidents. In order to improve the overall efficiency and quality of substation operation, the overcurrent protection in complex voltage direction of Substation operation is briefly discussed. 展开更多
关键词 substation operation overcurrent protection in negative pressure direction PRINCIPLE
原文传递
一种具有可调折返过流保护的LDO电路设计 被引量:1
13
作者 王晶 张瑛 +2 位作者 李玉标 罗寅 方玉明 《电子与封装》 2025年第2期62-67,共6页
基于CSMC 0.18μm BCD工艺,设计了一种具有可调折返限流功能且无须内部补偿的低压差线性稳压器(LDO)。为防止闩锁,设计了一个可通过外部单电阻调整折返点的限流结构。此外,为了降低LDO环路补偿的设计难度,设计了一种无须内部补偿的LDO... 基于CSMC 0.18μm BCD工艺,设计了一种具有可调折返限流功能且无须内部补偿的低压差线性稳压器(LDO)。为防止闩锁,设计了一个可通过外部单电阻调整折返点的限流结构。此外,为了降低LDO环路补偿的设计难度,设计了一种无须内部补偿的LDO环路。该设计的限流点为13.78 mA,短路电流为0.56 mA,在输入电压为3.4~42 V、输出电压为3V时,线性调整率不超过0.5 mV/V,且在轻载和重载情况下,相位裕度分别为89.7°和74.7°,1 kHz时电源抑制比为-65 dB。 展开更多
关键词 低压差线性稳压器 过流保护 折返限流 闩锁 无内部补偿
在线阅读 下载PDF
基于故障定位的航天器BDR过流保护优化设计
14
作者 井元良 胡梦森 +1 位作者 李海津 陈世杰 《航天器工程》 北大核心 2025年第4期58-65,共8页
针对航天器电源系统蓄电池放电调节器(BDR)过流保护需要区分故障发生位置来调整保护阈值的问题,提出一种基于故障定位的过流保护优化设计。当BDR模块内部发生短路故障时,保护开关立即在较低的阈值跳闸,将故障影响范围降至最低。当母线... 针对航天器电源系统蓄电池放电调节器(BDR)过流保护需要区分故障发生位置来调整保护阈值的问题,提出一种基于故障定位的过流保护优化设计。当BDR模块内部发生短路故障时,保护开关立即在较低的阈值跳闸,将故障影响范围降至最低。当母线发生短路故障时,保护开关在较高阈值下跳闸,为清除短路故障点提供足够的电能。通过仿真试验并搭建原理样机验证了该优化设计的有效性,即可实现准确定位短路故障,调整保护阈值,保证电源系统正常工作。 展开更多
关键词 航天器电源系统 蓄电池放电调节器 过流保护 故障定位
在线阅读 下载PDF
基于惯性同步的构网型永磁风电机组暂态控制改进策略
15
作者 张浩 李辉 +3 位作者 谭宏涛 郑杰 张振 向学位 《电力自动化设备》 北大核心 2025年第12期145-152,共8页
惯性同步控制可通过机网侧控制逻辑维持永磁风电机组构网运行,但在暂态工况下存在直流电压越限导致的惯性同步失效和暂态过流冲击问题。为此,提出一种改进的暂态控制策略,以兼顾惯性同步并网有效性与过流抑制。增加直流电压-机侧有功功... 惯性同步控制可通过机网侧控制逻辑维持永磁风电机组构网运行,但在暂态工况下存在直流电压越限导致的惯性同步失效和暂态过流冲击问题。为此,提出一种改进的暂态控制策略,以兼顾惯性同步并网有效性与过流抑制。增加直流电压-机侧有功功率下垂环路,考虑电压波动约束与功角曲线特性整定控制系数,使得机侧主动减载以维持直流电压稳定并保持惯性同步控制不失效;基于调制与限流双重约束重构等效内电势以抑制过流稳态周期分量,再结合反正切函数与电流越限边界设计自适应虚拟阻抗以抑制暂态直流分量。基于半实物实验平台验证所提策略的有效性,结果表明,在电网电压对称跌落时,所提策略可有效保障直流电压稳定和惯性同步控制有效,同时将暂态过电流限制在变流器电流上限与调制极限约束内。 展开更多
关键词 永磁风电机组 惯性同步控制 暂态稳定 过电流限制 自适应虚拟阻抗 风电
在线阅读 下载PDF
负序电流突变下基于动态热能模型的反时限保护曲线修正方案
16
作者 李振兴 安喆 +3 位作者 朱益 胡聪 翁汉琍 李振华 《电力系统保护与控制》 北大核心 2025年第18期26-38,共13页
针对发电机常规负序电流反时限保护无法准确刻画负序电流突变后保护动作时间问题,提出一种适应负序电流突变的基于动态热能模型的反时限保护曲线修正方法。首先,分析了基于新能源控制的发电机机端负序抑制策略以及在送出线路非全相期间... 针对发电机常规负序电流反时限保护无法准确刻画负序电流突变后保护动作时间问题,提出一种适应负序电流突变的基于动态热能模型的反时限保护曲线修正方法。首先,分析了基于新能源控制的发电机机端负序抑制策略以及在送出线路非全相期间的负序电流变化关系,提出应对负序电流三阶段变化的反时限保护动作方案。然后,考虑非周期分量发热、对流辐射散热,基于实时测量负序电流构建反映转子温度的动态热能模型。最后,将此模型融入负序反时限保护,利用定、转子稳态运行温度和预设负序电流刻画反时限保护动作曲线,并提出以输入实时负序电流推算转子温度为基础的反时限保护曲线修正方案。仿真实验结果表明:所构建的动态热能模型能精确刻画转子温度,基于此提出的保护曲线刻画、修正方案具有较高的准确性和较强的适应性。 展开更多
关键词 负序反时限保护 负序电流突变 动态热能模型 保护曲线修正
在线阅读 下载PDF
LCC-HVDC系统换流变压器阀侧单相接地保护的研究
17
作者 张艳霞 魏乐 《天津大学学报(自然科学与工程技术版)》 北大核心 2025年第11期1107-1123,共17页
换流器工作的非线性使得电网换相换流器型高压直流(LCC-HVDC)输电系统换流变压器阀侧绕组故障后的电流随着阀导通及换相而变化,实际工程中曾出现阀侧绕组单相接地故障后差动保护拒动情况.研究了换流变压器单相接地的分析方法和故障特性... 换流器工作的非线性使得电网换相换流器型高压直流(LCC-HVDC)输电系统换流变压器阀侧绕组故障后的电流随着阀导通及换相而变化,实际工程中曾出现阀侧绕组单相接地故障后差动保护拒动情况.研究了换流变压器单相接地的分析方法和故障特性,并依据故障特性分析了差动保护及零序过流保护的动作性能,提出一种换流变压器接地保护新方案.首先,采用时段划分法将故障后1个工频周期划分为12个时段,依据共同点对时段进行归类并按类分析了故障特性,将多时段合并得到故障后1个工频周期的网侧电流和阀侧电流表达式.然后,采用全波傅里叶算法计算差动电流及零序电流中的基波及各次谐波幅值,结果表明:由于低压桥换流变压器阀侧绕组单相接地后基波严重畸变,差动保护会因2次谐波含量大于15%而闭锁、零序过流保护因基波幅值小于整定值而拒动.为此,利用零序电流中2~6次谐波占比均大于15%反映这种故障,其与差动保护及零序过流保护互为补充,能提高换流变压器的保护性能.最后,搭建仿真模型验证了保护方案的有效性. 展开更多
关键词 换流变压器 阀侧绕组单相接地 差动保护 零序过流保护 谐波占比 接地保护
在线阅读 下载PDF
考虑暂态功角稳定的VSG低电压穿越控制策略
18
作者 李斌 高康佳 +2 位作者 焦琳峰 贾浩洋 龚祥祥 《电机与控制学报》 北大核心 2025年第7期108-118,共11页
为了同时解决虚拟同步发电机(VSG)在电网电压暂降时面临的暂态功角失稳与过电流问题,提出一种基于参数自适应调整的低电压穿越(LVRT)控制策略。以电压跌落系数作为判断系统是否发生故障的信号,一方面通过电压和阻抗自适应地调整有功功... 为了同时解决虚拟同步发电机(VSG)在电网电压暂降时面临的暂态功角失稳与过电流问题,提出一种基于参数自适应调整的低电压穿越(LVRT)控制策略。以电压跌落系数作为判断系统是否发生故障的信号,一方面通过电压和阻抗自适应地调整有功功率指令,另一方面结合电压跌落系数、角频率变化率和角频率偏差自适应地调整转动惯量和阻尼系数,以控制VSG稳定并快速恢复至稳定工作点,运用等面积定则分析VSG功角特性,从大信号角度验证策略提高了系统的稳定性。相较于现有方法,本策略创新性考虑了虚拟阻抗对暂态功角稳定性的影响,抑制过电流同时借助参数自主调节实现动态快速恢复过程。最后通过仿真和实验,对比引入不同策略对VSG的影响,结果验证了所提低电压穿越策略的正确性和有效性。 展开更多
关键词 虚拟同步发电机 自适应策略 低电压穿越 虚拟阻抗 暂态功角稳定 过电流抑制
在线阅读 下载PDF
一种具有不可恢复的过流保护电路设计
19
作者 唐俊 徐立浩 +2 位作者 王喆 张心静 李晨洋 《集成电路与嵌入式系统》 2025年第10期61-65,共5页
为满足工业设备过流保护需求,提出一种基于模块化设计的电子电路解决方案,旨在实现精准电流检测与快速保护响应。采用模块化设计架构,集成电流感应放大器、迟滞比较器和继电器协同工作。通过电流感应放大器实现0.1 mA级精度信号采集,利... 为满足工业设备过流保护需求,提出一种基于模块化设计的电子电路解决方案,旨在实现精准电流检测与快速保护响应。采用模块化设计架构,集成电流感应放大器、迟滞比较器和继电器协同工作。通过电流感应放大器实现0.1 mA级精度信号采集,利用迟滞比较器设置保护阈值,配合固态继电器执行电路通/断控制。实验结果表明:当电流超过设定阈值时,电路在10 ms内完成切断动作,且在阈值电流下降到阈值电流以下仍保持断路状态,避免误恢复。经多次循环测试验证,保护动作准确率达98.4%,有效杜绝了因多次过流对设备造成的潜在损害,为高精度电流保护提供创新方案。 展开更多
关键词 过流保护 模块化设计 电流感应放大器 切断电流通路 保持短路状态
在线阅读 下载PDF
零碳建筑产消式电气装置安全防护简析
20
作者 韩帅 《建筑电气》 2025年第9期14-18,共5页
分析零碳建筑中产消式电气装置的安全防护要求,从系统模式的转换、电击防护、热效应防护、过电流保护等方面简介常见的保护措施。分析产消式电气装置的系统接地原理,根据系统的组成架构探讨如何实现产消式电气装置的合理、安全设计。
关键词 零碳建筑 产消式电气装置 新型供配电系统 安全防护 系统接地 电击防护 热效应保护 过电流保护
在线阅读 下载PDF