期刊文献+
共找到665篇文章
< 1 2 34 >
每页显示 20 50 100
Theory and Experimental Verification on Valveless Piezoelectric Pump with Multistage Y-shape Treelike Bifurcate Tubes 被引量:8
1
作者 HUANG Jun ZHANG Jianhui +1 位作者 XUN Xianchao WANG Shouyin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第3期462-468,共7页
Among most traditional piezo water cooling systems, piezoelectric valve pumps are adopted as their driving sources. The valves in these pumps induce problems of shock and vibration and also make their structure compli... Among most traditional piezo water cooling systems, piezoelectric valve pumps are adopted as their driving sources. The valves in these pumps induce problems of shock and vibration and also make their structure complicated, which is uneasy to minimize and reduce their reliability and applicability of the whole system. In order to avoid these problems caused by valve structure, a novel valveless piezoelectric pump is developed, which integrates both functions of transforming and cooling. The pump’s Y-shape tree-like construction not only increases the efficiency of cooling but also the system reliability and applicability. Firstly, a multistage Y-shape treelike bifurcate tube is proposed, then a valveless piezoelectric pump with multistage Y-shape treelike bifurcate tubes is designed and its working principle is analyzed. Then, the theoretical analysis of flow resistance characteristics and the flow rate of the valveless piezoelectric pump are performed. Meanwhile, commercial software CFX is employed to perform the numerical simulation for the pump. Finally, this valveless piezoelectric pump is fabricated, the relationship between the flow rates and driving frequency, as well as the relationship between the back pressure and the driving frequency are experimentally investigated. The experimental results show that the maximum flow rate is 35.6 mL/min under 100 V peak-to-peak voltage (10.3 Hz) power supply, and the maximum back pressure is 55 mm H2O under 100 V (9 Hz) power supply, which validates the feasibility of the valveless piezoelectric pump with multistage Y-shape treelike bifurcate tubes. The proposed research provides certain references for the design of valveless piezoelectric pump and improves the reliability of piezo water cooling systems. 展开更多
关键词 PIEZOELECTRIC PUMP valveless y-shape tube treelike bifurcate
在线阅读 下载PDF
Analysis of the Flow Rate Characteristics of Valveless Piezoelectric Pump with Fractal-like Y-shape Branching Tubes 被引量:7
2
作者 HUANG Jun ZHANG Jianhui +1 位作者 WANG Shouyin LIU Weidong 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第3期628-634,共7页
Microchannel heat sink with high heat transfer coefficients has been extensively investigated due to its wide application prospective in electronic cooling. However, this cooling system requires a separate pump to dri... Microchannel heat sink with high heat transfer coefficients has been extensively investigated due to its wide application prospective in electronic cooling. However, this cooling system requires a separate pump to drive the fluid transfer, which is uneasy to minimize and reduces their reliability and applicability of the whole system. In order to avoid these problems, valveless piezoelectric pump with fractal-like Y-shape branching tubes is proposed. Fractal-like Y-shape branching tube used in microchannel heat sinks is exploited as no-moving-part valve of the valveless piezoelectric pump. In order to obtain flow characteristics of the pump, the relationship between tube structure and flow rate of the pump is studied. Specifically, the flow resistances of fractal-like Y-shape branching tubes and flow rate of the pump are analyzed by using fractal theory. Then, finite element software is employed to simulate the flow field of the tube, and the relationships between pressure drop and flow rate along merging and dividing flows are obtained. Finally, valveless piezoelectric pumps with fractal-like Y-shape branching tubes with different fractal dimensions of diameter distribution are fabricated, and flow rate experiment is conducted. The experimental results show that the flow rate of the pump increases with the rise of fractal dimension of the tube diameter. When fractal dimension is 3, the maximum flow rate of the valveless pump is 29.16 mL/min under 100 V peak to peak (13 Hz) power supply, which reveals the relationship between flow rate and fractal dimensions of tube diameter distribution. This paper investigates the flow characteristics of valveless piezoelectric pump with fractal-like Y-shape branching tubes, which provides certain references for valveless piezoelectric pump with fractal-like Y-shape branching tubes in application on electronic chip cooling. 展开更多
关键词 PIEZOELECTRIC PUMP valveless fractal-like y-shape branching tube
在线阅读 下载PDF
Gastrotracheal fistula:Treatment with a covered self-expanding Y-shaped metallic stent 被引量:2
3
作者 Fei Wang Hong Yu +4 位作者 Ming-Hui Zhu Quan-Peng Li Xian-Xiu Ge Jun-Jie Nie Lin Miao 《World Journal of Gastroenterology》 SCIE CAS 2015年第3期1032-1035,共4页
A 67-year-old man had a sev-ere cough and pulmonary infection for 1 wk before seeking evaluation at our hospital.He had undergone esophagectomy with gastric pull-up and radiotherapy for esophageal cancer 3 years previ... A 67-year-old man had a sev-ere cough and pulmonary infection for 1 wk before seeking evaluation at our hospital.He had undergone esophagectomy with gastric pull-up and radiotherapy for esophageal cancer 3 years previously.After admission to our hospital,gastroscopy and bronchoscopy revealed a fistulous communication between the posterior tracheal wallnear the carina and the upper residual stomach.We measured the diameter of the trachea and bronchus and determined the site and size of the fistula using multislice computed tomography and gastroscopy.A covered self-expanding Y-shaped metallic stent was implanted into the trachea and bronchus.Subsequently,the fistula was closed completely.The patient tolerated the stent well and had good palliation of his symptoms. 展开更多
关键词 Gastrotracheal FISTULA y-shaped metallic STENT ESO
暂未订购
Y-shaped block copolymers of poly(ethylene glycol) and poly(N-isopropylacrylamide) synthesized by ATRP 被引量:2
4
作者 Xin De Tang Xiao Chao Liang Nian Feng Han 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第11期1353-1356,共4页
Novel Y-shaped block copolymers of poly(ethylene glycol) and poly(N-isopropylacrylamide), PEG-b-(PNIPAM)2, were successfully synthesized through atom transfer radical polymerization (ATRP). A difunctional macr... Novel Y-shaped block copolymers of poly(ethylene glycol) and poly(N-isopropylacrylamide), PEG-b-(PNIPAM)2, were successfully synthesized through atom transfer radical polymerization (ATRP). A difunctional macroinitiator was prepared by esterification of 2,2-dichloroacetyl chloride with poly(ethylene glycol) monomethyl ether (PEG). The copolymers were obtained via the ATRP ofN-isopropylacrylamide (NIPAM) at 30℃ with CuCl/Me6TREN as a catalyst system and DMF/H2O (v/v = 3:1) mixture as solvent. The resulting copolymers were characterized by gel permeation chromatography (GPC) and ^1H NMR. These block copolymers show controllable molecular weights and narrow molecular weight distributions (PDI 〈 1.15). Their phase transition temperatures and the corresponding enthalpy changes in aqueous solution were measured by differential scanning calorimetry (DSC). As a result, the phase transition temperature of PEG45-b-(PNIPAM55)2 is higher than that of PNIPAM, however, the corresponding enthalpy change is much lower, indicating the significant influence of the macromolecular composition and architecture on the phase transition. 展开更多
关键词 y-shaped Block copolymer Poly(ethylene glycol) Poly(N-isopropylacrylamide) Atom transfer radical polymerization (ATRP)
在线阅读 下载PDF
基于Y-shaped路网的早高峰拼车定价策略
5
作者 贺冬冬 仲秋雁 曲毅 《系统工程学报》 CSCD 北大核心 2023年第5期706-722,共17页
针对交通资源配置有限导致的早高峰通勤拥堵问题,借鉴共享经济理论,引入拼车出行概念,充分考虑通勤者出行方式和Y-shaped路网特点,建立了基于通勤者出行效益的拼车定价模型.模型结合费用补偿机制,讨论了以平台利润最大化和系统负效用最... 针对交通资源配置有限导致的早高峰通勤拥堵问题,借鉴共享经济理论,引入拼车出行概念,充分考虑通勤者出行方式和Y-shaped路网特点,建立了基于通勤者出行效益的拼车定价模型.模型结合费用补偿机制,讨论了以平台利润最大化和系统负效用最小化为目标的拼车定价策略,并给出了定价策略有效的阈值条件.研究结果表明,当通勤者都参与到拼车服务中时,拼车平台利润和交通系统负效用在其相应拼车定价策略下均能达到最优值,并且以交通系统负效用最小化为目标的拼车定价策略能消除Y-shaped路网中瓶颈处的交通拥堵. 展开更多
关键词 动态拼车 y-shaped瓶颈模型 拼车定价 早高峰通勤
在线阅读 下载PDF
Evaluation of ultimate bearing capacity of Y-shaped vibro-pile
6
作者 王新泉 陈永辉 +2 位作者 林飞 卢孝益 张霆 《Journal of Central South University》 SCIE EI CAS 2008年第S2期186-194,共9页
Based on Mindlin stress solution, a numerical computational method was proposed to calculate the stresses in the ground induced by side friction and the resistance of Y-shaped vibro-pile. The improved Terzaghi's a... Based on Mindlin stress solution, a numerical computational method was proposed to calculate the stresses in the ground induced by side friction and the resistance of Y-shaped vibro-pile. The improved Terzaghi's and ЪерезанцевВГ's methods for ultimate bearing capacity evaluation were proposed by considering the stress strength induced by friction resistance at pile head level of Y-pile. A new method to calculate the ultimate bearing capacity of Y-pile was also proposed based on the assumptions of soil failure mode at the tip of Y-pile and the use of Mohr-Coulomb soil yield criterion and Vesic compressive correction coefficient with the induced stresses in the ground. Based on the comparisons with the field static load test results, it is found that the improved Terzaghi's method gives higher ultimate capacity, while the other two methods shows good agreement with the field results. 展开更多
关键词 y-shaped vibro-pile circular PILE MINDLIN stress solution ULTIMATE bearing capacity of PILE TIP static loading test
在线阅读 下载PDF
Transfer characteristics of dynamic biochemical signals in non-reversing pulsatile flows in a shallow Y-shaped microfluidic channel: signal filtering and nonlinear amplitude-frequency modulation
7
作者 Zongzheng CHEN Weimo YUAN +4 位作者 A.R.AZIZ Zhengming GAO Depei ZENG Bo LIU Kairong QIN 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2017年第10期1481-1496,共16页
The transports of the dynamic biochemical signals in the non-reversing pulsatile flows in the mixing microchannel of a Y-shaped microfluidic device are ana- lyzed. The results show that the mixing micro-channel acts a... The transports of the dynamic biochemical signals in the non-reversing pulsatile flows in the mixing microchannel of a Y-shaped microfluidic device are ana- lyzed. The results show that the mixing micro-channel acts as a low-pass filter, and the biochemical signals are nonlinearly modulated by the pulsatile flows, which depend on the biochemical signal frequency, the flow signal frequency, and the biochemical signal transporting distance. It is concluded that, the transfer characteristics of the dynamic biochemical signals, which are transported in the time-varying flows, should be carefully considered for better loading biochemical signals on the cells cultured on the bottom of the microfluidic channel. 展开更多
关键词 shallow y-shaped microfluidic channel dynamic biochemical signal non-reversing pulsatile flow nonlinear amplitude-frequency modulation Taylor-Aris disper-sion
在线阅读 下载PDF
Flow around three rectangular cylinders arranged in connected and separated Y-shape
8
作者 Zhifu Gu Yan Li 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2005年第4期336-341,共6页
Characteristics of cross flow around three rectangular cylinders with two aspect ratios of breadth to width arranged in connected and separated Y-shape at various angles of incident flow were studied by means of force... Characteristics of cross flow around three rectangular cylinders with two aspect ratios of breadth to width arranged in connected and separated Y-shape at various angles of incident flow were studied by means of force measurement in a wind tunnel. Flow visualizations with smoke-wire technique for typical cases were also given. Different types of flow patterns were formed for individual models at different angles of incident flow. From the results of fluctuating velocity measurement in the wake, features of vibration were determined. It shows that as the wind blows along the lines of one limb or rectangular cylinder of the model, oscillation is weak, whereas when the wind blows along the bisector lines of two limbs or cylinders, strong vibration is observed. It is associated with the regular vortex shedding. 展开更多
关键词 Rectangular cylinders. Vortex-induced vibration Flow visualization y-shape
在线阅读 下载PDF
Binary collision approximation for solitary waves in a Y-shaped granular chain
9
作者 陈琼 杨先清 +2 位作者 赵新印 王振辉 赵跃民 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第1期350-355,共6页
We implement a binary collision approximation to study solitary wave propagation in a two-dimensional double Y- shaped granular chain. The solitary wave was transmitted and reflected when it met the interface of the b... We implement a binary collision approximation to study solitary wave propagation in a two-dimensional double Y- shaped granular chain. The solitary wave was transmitted and reflected when it met the interface of the bifurcated branches of the Y-shaped granular chains. We obtain the analytic results of the ratios of the transmitted and reflected speeds to the incident speed of the solitary wave, the maximum force between the two neighbor beads in a solitary wave, and the total time taken by the pulse to pass through each branch. All of the analytic results are in good agreement with the experimental observations from Daraio et al. [Phys. Rev. E 82 036603 (2010)]. Moreover, we also discuss the delay effects on the arrival of split pulses, and predict the recombination of the split waves traveling in branches in the final stem of asymmetric systems. The prediction of pulse recombination is verified by our numerical results. 展开更多
关键词 y-shaped granule chain solitary wave binary collision approximation
原文传递
Influence of the Unit Y-Shaped Microchannel Geometry on the Capillary Flow
10
作者 刘旺玉 陈伟 +1 位作者 彭毅 罗远强 《Journal of Shanghai Jiaotong university(Science)》 EI 2015年第4期443-448,共6页
Fractal networks are widely applied in the field of heat and mass transfer. As one of the important parts of the fractal network, Y-shaped structure definitely has a significant impact on the performance of the whole ... Fractal networks are widely applied in the field of heat and mass transfer. As one of the important parts of the fractal network, Y-shaped structure definitely has a significant impact on the performance of the whole network. In this paper, the analytical relationship between Y-shaped microchannel geometry and its capillary flow time is established through theoretical analysis with mass continuity equation and Navier-Stokes(N-S) equations.The result reveals that the capillary flow time increases with the increase of the topology length and bifurcation angle of the Y-shaped microchannel, but decreases with the increase of the channel width. 展开更多
关键词 y-shaped microchannel fractal network capillary flow
原文传递
CFD study of flow-diffusion process in Y-shape micromixer
11
作者 陈卓 张睿琦 王晓娜 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第4期969-974,共6页
A CFD simulation was carried out to investigate the mixing process in a Y-shape micromixer with the software Fluent 6.3. The definition of the "diffusion angle" is proposed to describe the molecular diffusio... A CFD simulation was carried out to investigate the mixing process in a Y-shape micromixer with the software Fluent 6.3. The definition of the "diffusion angle" is proposed to describe the molecular diffusion process associated with the flow at low Reynolds number. The linear relationship between the diffusion angle and the Peclet number(Pe) is determined by both theoretical analysis and numerical simulation. Moreover, the simulation results reveal that the diffusion angle is only related to the Peclet number whilst it is irrelevant to the changes of Re(Reynolds number) and Sc(Schmidt number). The range of Peclet number and Reynolds number for experimental measurement are also suggested as Pe≤10000 and Re≤10. 展开更多
关键词 SIMULATION flow-diffusion process molecular diffusion y-shape micromixer
在线阅读 下载PDF
Deformation and defects in hydroforming of Y-shaped tubes
12
作者 程东明 滕步刚 +1 位作者 郭斌 苑世剑 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2008年第2期206-210,共5页
Hydroforming process of a Y-shaped stainless steel tube was investigated through numerical simulation and experiments. The forming process and reasons of typical defects were analyzed with three different loading path... Hydroforming process of a Y-shaped stainless steel tube was investigated through numerical simulation and experiments. The forming process and reasons of typical defects were analyzed with three different loading paths. Thickness distribution of formed Y-shaped tube was obtained. It is shown by numerical and experimental results that the transition regions are depressed in the forming condition of low inner pressure and wrinkles occur, while fracture occurs in the forming condition of high inner pressure. After forming, the thickness in left transition fillet region is the largest, that in fight transition fillet region is thinner, and the thinnest thickness is at the top of the protrusion. The original thickness line is below the top of the protrusion. The thinning area occurs above this line, while the thickening area is below this line. The maximum thinning rate is significantly increased as the calibration pressure increases, while the maximum thickening rate remains almost unchanged. 展开更多
关键词 HYDROFORMING y-shaped tube loading path DEFECTS thickness
在线阅读 下载PDF
Y-Shaped Intra-Scleral Fixated Lens versus Retro-Pupillary Iris Claw Lens in the Treatment of Aphakia
13
作者 Ahmed Mohamed Morshed Mahmoud Nasr Aldeeb +1 位作者 Adel Kamal Abdeen Salah Mohamed Almosalamy 《Open Journal of Ophthalmology》 2019年第2期105-124,共20页
Background: Many reasons can lead to an aphakia without adequate capsular support for implantation of a posterior chamber intraocular lens (IOL), such as intraoperative unintentional rupture of posterior capsule durin... Background: Many reasons can lead to an aphakia without adequate capsular support for implantation of a posterior chamber intraocular lens (IOL), such as intraoperative unintentional rupture of posterior capsule during phacoemulsification, planned intracapsular cataract extraction, ocular trauma and lens dislocation due to congenital and acquired causes. Purpose: To compare Y-shaped intra-scleral fixation of a posterior chamber IOL with retro pupillary fixation of an iris-claw intraocular lens (IOL) for Aphakic eyes without sufficient capsular support as respects safety, visual recovery and complications of both methods. Patients and Methods: One hundred Aphakic eyes were arbitrarily distributed between two groups. Group A included 50 eyes treated with retropupillary fixation of iris claw lens and group B included 50 eyes treated with Y-shaped intra-scleral fixation technique. Preoperative, intraoperative and postoperative data were analysed including best corrected visual acuity (BCVA), intraocular pressure (IOP), surgical time, intraoperative problems, IOL malposition and postoperative complications. Following up on patients was carried out for at least six months. Results: The mean duration of surgery was 21 ± 5.3 min in group A and was 53.4 ± 6.9 min in group B (p-value 0.05). IOL tilt was found in 0 (0%) eyes in group A and in 5 (10%) eyes in group B (p 0.05). Conclusion: The results of our study indicated that both methods are satisfactory in correcting aphakia without sufficient capsular support as regards postoperative best corrected visual acuity (BCVA);however the surgical technique of retropupillary iris claw lens is easier, shorter, with low intra- and postoperative complications and safer than those used for intra-scleral fixation of IOL. But for eyes which lack both iris and capsular support, a scleral fixation of a posterior chamber IOL remains the only option. 展开更多
关键词 APHAKIA Iris-Claw Intraocular LENS (IOL) y-shaped INTRA Scleral Fixation
暂未订购
Comparison of lag screws and double Y-shaped miniplates in the fixation of anterior mandibular fractures
14
作者 Lydia Melek 《World Journal of Methodology》 2021年第3期88-94,共7页
BACKGROUNDMandibular fractures constitute about 80.79% of maxillofacial injuries inAlexandria University, either as isolated mandibular fractures or as a part ofpanfacial fractures. The combination of symphyseal and p... BACKGROUNDMandibular fractures constitute about 80.79% of maxillofacial injuries inAlexandria University, either as isolated mandibular fractures or as a part ofpanfacial fractures. The combination of symphyseal and parasymphyseal fracturesrepresent 47.09% of the total mandibular fractures.AIMTo compare the effectiveness of lag screws vs double Y-shaped miniplates in thefixation of anterior mandibular fractures.METHODSThis study is a prospective randomized controlled clinical trial, performed onsixteen patients with anterior mandibular fractures. Patients were divided equallyinto two groups, each consisting of eight patients. Group 1: Underwent openreduction and internal fixation using two lag screws. Group 2: Underwent openreduction and internal fixation using double Y-shaped plates. The followingparameters were assessed: operating time in minutes, pain using a visual analogscale, edema, surgical wound healing for signs and symptoms of infection,occlusion status and stability, maximal mouth opening, and sensory nervefunction. Cone beam computed tomography was performed at 3 and 6 mo tomeasure bone density and assess the progression of fracture healing.RESULTSThe study included 13 males (81.3%) and 3 females (18.8%) aged 26 to 45 years(mean age was 35.69 ± 6.01 years). The cause of trauma was road traffic accidentsin 10 patients (62.5%), interpersonal violence in 3 patients (18.8%) and othercauses in 3 patients (18.8%). The fractures comprised 10 parasymphyseal fractures(62.5%) and 6 symphyseal fractures (37.5%). The values of all parameters were comparable in both groups with no statistically significant difference except forthe mean bone density at 3 mo postoperatively which was 946.38 ± 66.29 in group 1 and 830.36 ± 95.53 in group 2 (P = 0.015).CONCLUSIONBoth lag screws and double Y-shaped miniplates provide favorable means offixation for mandibular fractures in the anterior region. Fractures fixed with lagscrews show greater mean bone density at 3 mo post-operation, indicative ofhigher primary stability and faster early bone healing. Further studies with largersample sizes are required to verify these conclusions. 展开更多
关键词 Anterior mandibular fractures Symphyseal fracture Parasymphyseal fracture MINIPLATES Lag screws Double y-shaped plates
暂未订购
Investigation of Tree Structure Parameters of High-quality and High-yielding Y-shaped Pear Orchards 被引量:1
15
作者 Shuwei WEI Shaomin WANG +2 位作者 Ran DONG Kun RAN Hongwei WANG 《Agricultural Biotechnology》 CAS 2019年第2期101-103,共3页
In order to study reasonable tree structure parameters of Y-shaped pear orchards in natural conditions and at management technical level of Tai'an area, the tree structure and population structure of high-quality ... In order to study reasonable tree structure parameters of Y-shaped pear orchards in natural conditions and at management technical level of Tai'an area, the tree structure and population structure of high-quality and high-yielding Y-shaped pear orchards were investigated. The results showed that when the yield of Y-shaped 'Oshu' was 2 550 kg/667 m^2 in the early fully fruiting period, the quantity of the branches per 667 m^2 was about 54 000, and the number of short branches was the largest, accounting for 80.1% of total number of branches, followed by middle branches, long branches and developmental branches. As the yield of Y-shaped 'Qiuyue' was 2 875 kg/667 m^2 in the early fully fruiting period, the quantity of the branches per 667 m^2 was 51 000, and the number of short branches was the largest, accounting for 75.6% of total number of branches, followed by middle branches, long branches and developmental branches. When the yield of Y-shaped 'Niitaka' was 3 000 kg/667 m^2 in the early fully fruiting period, the quantity of the branches per 667 m^2 was 43 000, and the number of short branches was the largest, accounting for 82.0% of total number of branches, followed by long branches, middle branches and developmental branches. 展开更多
关键词 PEAR Y shape HIGH-QUALITY and HIGH-YIELDING TREE structure parameters
在线阅读 下载PDF
Sensitive and Specific Y-Shaped Ratio Biosensor for Detecting Serum mi R-18a:Potential Early Scanning Tool for Non-Small Cell Lung Cancer
16
作者 Fei Yu Yue Wang +2 位作者 Caiyuan Yu Wei Zhang Xuefeng Bai 《Journal of Analysis and Testing》 EI CSCD 2024年第2期237-244,共8页
miR-18a has been identified as a significantly expressed microRNA(miRNA)in non-small cell lung cancer(NSCLC)and plays a vital role in cancer cell transformation,metastasis,and carcinogenesis.Herein,a pair of binary pr... miR-18a has been identified as a significantly expressed microRNA(miRNA)in non-small cell lung cancer(NSCLC)and plays a vital role in cancer cell transformation,metastasis,and carcinogenesis.Herein,a pair of binary probes from numerous probe pairs based on single nucleotide polymorphism analyses of miR-18a and miR-18b was first designed and screened to develop a Y-shaped ratio biosensor for accurate detection of serum miR-18a in NSCLC.The special structure of the binary probes combined with the hairpin showed strong specificity for miR-18a,which was confirmed by polyacrylamide gel electrophoresis assay and square wave voltammetry assay.Furthermore,it is beneficial to immobilize single-stranded DNA(ssDNA)probes due to the large specific surface area of nanoporous gold,thereby improving the sensitivity of the biosensor.The Y-shaped ratio biosensor exhibited a wide detection range and can quantify the concentration of miR-18a in the range of 10 fmol/L–100 pmol/L,with a limit of detection of 0.211 fmol/L(S/N=3).Moreover,it exhibits excellent detection capabilities in serum samples since the biosensor showed a high selectivity toward the coexistence of miR-18a and miR-18b.Therefore,the prepared Y-shaped ratio biosensor is a highly sensitive and specific miR-18a detection tool,capable of identifying microscopic amounts of miR-18a in serum samples,providing great potential for early screening of NSCLC. 展开更多
关键词 Nanoporous gold y-shaped biosensor miR-18a NSCLC
原文传递
外踝前静脉网多段倒“Y”型静脉移植修复掌浅弓以远断掌损伤
17
作者 张钊 王燕燕 +6 位作者 高飞 潘月海 黄恒 路超 王国忠 屈志刚 毕本军 《中国修复重建外科杂志》 北大核心 2025年第5期628-632,共5页
目的探讨外踝前静脉网多段倒“Y”型静脉移植修复掌浅弓以远损伤治疗复杂断掌的临床效果。方法2018年9月—2023年7月,收治5例机器损伤导致的伴掌浅弓以远损伤断掌患者。男3例,女2例;年龄29~52岁,平均35.4岁。受伤至入院时间1~6 h,平均3.... 目的探讨外踝前静脉网多段倒“Y”型静脉移植修复掌浅弓以远损伤治疗复杂断掌的临床效果。方法2018年9月—2023年7月,收治5例机器损伤导致的伴掌浅弓以远损伤断掌患者。男3例,女2例;年龄29~52岁,平均35.4岁。受伤至入院时间1~6 h,平均3.2 h。术中切取患侧外踝前静脉网多段倒“Y”型静脉,移植于掌浅弓以远指掌侧总动脉与指固有动脉缺损处;以对侧外踝前静脉网移植重建手背静脉。1例伴手背软组织缺损,采用髂腹股沟带蒂皮瓣修复;供区直接拉拢缝合。术后给予抗感染、抗痉挛、预防血栓形成等处理。结果术后1例发生拇指指尖部分坏死,1例髂腹股沟皮瓣边缘坏死;其余手指血运良好,张力正常。腹部皮瓣供区切口Ⅰ期愈合。5例患者均获随访,随访时间8~41个月,中位时间19个月。末次随访时,患者手部外形满意;手指抓握及对掌功能恢复;本体感觉恢复,两点辨别觉5~7 mm,平均6 mm;根据中华医学会上肢部分功能评定试用标准,患肢功能获优3例、良1例、差1例。结论外踝前静脉网多段倒“Y”型静脉移植修复掌浅弓以远指掌侧总动脉及指固有动脉缺损,具有位置表浅、取材灵活、匹配度高等优势,用于复杂断掌修复重建可获得较好疗效。 展开更多
关键词 外踝前静脉网 掌浅弓 血管移植 断掌 倒Y型静脉
原文传递
三进一回Y型通风下瓦斯动态演化规律及风量二次规划研究
18
作者 梁运培 郭亚博 +4 位作者 李全贵 孙万杰 李赏 郑梦浩 王程成 《矿业安全与环保》 北大核心 2025年第3期56-64,共9页
为了研究三进一回Y型通风工作面及采空区瓦斯的动态演化规律,探索进风巷风量最优配比,以山西某矿31002工作面为研究对象建立多孔介质模型,基于Fluent实现工作面及采空区的瓦斯流场数值模拟。分析了三进一回Y型通风瓦斯流场中瓦斯浓度、... 为了研究三进一回Y型通风工作面及采空区瓦斯的动态演化规律,探索进风巷风量最优配比,以山西某矿31002工作面为研究对象建立多孔介质模型,基于Fluent实现工作面及采空区的瓦斯流场数值模拟。分析了三进一回Y型通风瓦斯流场中瓦斯浓度、气体压力、风流的基本分布规律,以及3条进风巷不同风量配比下瓦斯浓度的演化规律。通过模拟生成30组样本数据,拟合后生成风量与上隅角瓦斯浓度之间的多元非线性回归函数关系式,根据数值模拟的先验规律对目标函数进行二次规划求解,最终得到最优的风量配比。研究表明:进风巷2、3位置接近,靠近工作面区域会出现涡流,在一定程度上会导致瓦斯富集;当进风巷1的风量大于其余2条进风巷风量之和时,瓦斯富集区域主要集中于沿工作面长度约90 m处至上隅角区域,采空区靠近工作面处瓦斯浓度富集区域为90~220 m,改变进风巷2、3之间的风量配比后瓦斯浓度平均下降约0.19%;目标函数在先验规律约束下,得出3条进风巷最优风量配比为1.08∶1.23∶1.23。研究结果为工作面瓦斯超限治理、矿井瓦斯灾害防治提供了理论支撑。 展开更多
关键词 Y型通风 最优风量配比 上隅角 瓦斯流场 瓦斯超限
在线阅读 下载PDF
“Y”形切剥加内痔柱状缝扎悬吊治疗环状混合痔的临床研究
19
作者 代述东 杨顺 +4 位作者 黄付仙 武琳琳 江媛媛 刘乔 刘丹 《中外医疗》 2025年第9期46-49,58,共5页
目的 探讨“Y”形切剥加内痔柱状缝扎悬吊术(Y-shaped incision and dissection combined with internal hemorrhoid ligation and suspension,YID-IHLS)在治疗环状混合痔中的临床效果,并与传统外剥内扎术(milligan-morgan hemorrhoidec... 目的 探讨“Y”形切剥加内痔柱状缝扎悬吊术(Y-shaped incision and dissection combined with internal hemorrhoid ligation and suspension,YID-IHLS)在治疗环状混合痔中的临床效果,并与传统外剥内扎术(milligan-morgan hemorrhoidectomy,MMH)进行对比分析。方法 选取2023年9月—2024年9月都江堰市中医医院肛肠科收治的134例环状混合痔患者作为研究对象,根据患者手术方式的不同分组,每组67例。观察组采用YID-IHLS治疗,而对照组则采用MMH治疗。比较两组术后康复情况、术后症状评分及术后肛门功能。结果 观察组住院时间、创面愈合时间均短于对照组,差异均有统计学意义(P均<0.05)。术后,观察组肛门疼痛、肛门出血、创面水肿、排便情况评分均低于对照组,差异均有统计学意义(P均<0.05)。术后3个月,观察组肛门狭窄(0.37±0.09)分和控便能力评分(0.49±0.10)分低于对照组的(1.58±0.24)分、(1.09±0.14)分,差异均有统计学意义(t=38.640,28.546;P均<0.05)。结论 YID-IHLS治疗环状混合痔相较于传统MMH手术,在缩短住院时间和创面愈合时间、减轻术后症状以及改善肛门功能方面表现出显著优势。 展开更多
关键词 环状混合痔 “Y”形 悬吊 住院时间 愈合时间 并发症
暂未订购
上一页 1 2 34 下一页 到第
使用帮助 返回顶部