期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Sulfur speciation transformation during bioleaching of pyrite-containing sphalerite concentrate by thermophile Sulfolobus metallicus at 65 °C 被引量:4
1
作者 夏金兰 赵小娟 +7 位作者 梁长利 杨益 聂珍媛 汤露 马陈燕 郑雷 赵屹东 邱冠周 《Journal of Central South University》 SCIE EI CAS 2012年第7期1961-1966,共6页
Sulfur speciation transformation during bioleaching of pyrite-containing sphalerite concentrate by thermophile Sulfolobus metallicus (S. metallicus) at 65 ℃ was investigated by X-ray diffraction (XRD), diffuse re... Sulfur speciation transformation during bioleaching of pyrite-containing sphalerite concentrate by thermophile Sulfolobus metallicus (S. metallicus) at 65 ℃ was investigated by X-ray diffraction (XRD), diffuse reflectance Fourier transform infrared spectroscopy (FT-IR) and sulfur K-edge X-ray absorption near edge structure spectroscopy (XANES). The results show that the presence of S. metallicus effectively enhances the dissolution of the mineral. The yield of zinc increases from 0.5 g/L in sterile control to 2.7 g/L in bioleaching. The pyrite in the concentrate facilitates zinc dissolution in the early stage, but has hindrance role in the late stage for the formation of jarosite. Sulfur speciation analyses show that jarosite and elemental sulfur are main products in bioleaching process, and the accumulation ofjarosite is mainly responsible for the decline of leaching efficiency. 展开更多
关键词 SPHALERITE BIOLEACHING Sulfolobus metallicus sulfur K-edge X-ray absorption near edge spectroscopy xanes sulfurspeciation transformation
在线阅读 下载PDF
Total electron yield mode for XANES measurements in the energy region of 2.1-6.0 keV
2
作者 郑雷 赵屹东 +3 位作者 唐坤 马陈燕 韩勇 崔明启 《Chinese Physics C》 SCIE CAS CSCD 2011年第2期199-202,共4页
The total electron yield (TEY) mode has been developed successfully for XANES measurements at Beamline 4BTA of BSRF (Beijing Synchrotron Radiation Facility). Its performance was studied by measuring sulphur K-edge... The total electron yield (TEY) mode has been developed successfully for XANES measurements at Beamline 4BTA of BSRF (Beijing Synchrotron Radiation Facility). Its performance was studied by measuring sulphur K-edge XANES of three CdS samples (mixed with graphite powder as an electric conductor) with different concentration: 75%, 50~ and 25%. The data are collected in TEY mode and fluorescence yield (FY) mode respectively for comparison. The results demonstrate that the TEY spectra of three samples agree well with each other after the background is subtracted and normalized. The measured XANES spectra by TEY mode without bias and with 100V bias are almost identical to one another, but the signal-to-noise ratio of spectra measured without bias is better than that with 100V bias. The consistency of the self-absorption corrected FY spectra and TEY spectra are within 10% for the three samples. 展开更多
关键词 X-ray absorption near edge structure xanes spectroscopy total electron yield (TEY) fluorescence yield (FY) 4BTA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部