This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation ...This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation transfer function(MTF),and detective quantum efficiency(DQE)of the DL-FPD are evaluated numerically using a linear cascade model.In addition,both the single-crystal(SC)and polycrystalline(PC)structures of MAPbI_(3)are investigated,along with various other key parameters such as the material thickness,electric field strength,X-ray beam spectrum,and electronic readout noise.The results demonstrate that SC perovskite consistently exhibits better performance than PC perovskite owing to fewer material defects.Increasing the layer thickness may decrease the MTF,but can also enhance the sensitivity and DQE.Moreover,appropriately increasing the external electric field within the material can improve the sensitivity,MTF,and DQE.Finally,reducing the electronic readout noise can significantly enhance the DQE for low-dose imaging.This study demonstrates the potential of high-quality dual-energy X-ray imaging using direct-conversion perovskite DL-FPDs.展开更多
With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this ...With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this study,the effects of X-ray beam size and photon energy on the accuracy of critical dimension measurements were investigated.Critical dimensions measured using beams with different spot sizes showed different deviations from the expected values.Beam sizes that were either too large or too small did not improve confidence intervals.As the incident energy increased,the X-ray transmission rate increased,while the scattering cross section decreased,resulting in a gradual decrease in the signal-to-noise ratio of the diffraction peaks,which reduced the accuracy of the CD-SAXS measurements.An optimal accuracy was obtained at 12 keV with a smaller beam size.Using an effective trapezoid model,the results yielded an average pitch of 100.4±0.2 nm,width of 49.8±0.2 nm,height of 130.0±0.2 nm,and a sidewall angle below 1.1°±0.1°.These results provide crucial guidance for the future development of CD-SAXS laboratories and the construction of X-ray machines as well as robust support for research in related fields.展开更多
A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-d...A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-dimensional cusp boundary from a two-dimensional X-ray image because the detected X-ray signals will be integrated along the line of sight.In this work,a global magnetohydrodynamic code was used to simulate the X-ray images and photon count images,assuming an interplanetary magnetic field with a pure Bz component.The assumption of an elliptic cusp boundary at a given altitude was used to trace the equatorward and poleward boundaries of the cusp from a simulated X-ray image.The average discrepancy was less than 0.1 RE.To reduce the influence of instrument effects and cosmic X-ray backgrounds,image denoising was considered before applying the method above to SXI photon count images.The cusp boundaries were reasonably reconstructed from the noisy X-ray image.展开更多
This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both commo...This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification.展开更多
Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics...Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics,and free electron radiation devices.Particularly,they are promising platforms for studying thermionic emission.It is illustrated that using vdW heterostructure-based thermionic emission can enhance heat transfer in vacuum devices.As a proof of concept,the approach is demonstrated to offer a promising solution for the long-standing overheating issue in X-ray tubes.Specifically,it is shown that the saturated target temperature of a 2000 W X-ray tube can be reduced from around 1200℃ to 490℃.Additionally,it is also demonstrated that by reducing the height of the Schottky barrier formed in the vdW heterostructures,the thermionic cooling performance can be enhanced.The findings pave the way for the development of high-power X-ray tubes.展开更多
Stars getting close enough to black holes(BHs)can be torn apart by strong tidal forces,producing electromagnetic flares.To date,more than 100 tidal disruption events(TDEs)have been observed,each involving invariably n...Stars getting close enough to black holes(BHs)can be torn apart by strong tidal forces,producing electromagnetic flares.To date,more than 100 tidal disruption events(TDEs)have been observed,each involving invariably normal gaseous stars whose debris falls onto the BH,sustaining the flares over years.White dwarfs(WDs),which are the most prevalent compact stars and a million times denser-and therefore tougher-than gaseous stars,can only be disrupted by intermediate-mass black holes(IMBHs)of 10^(2)–10^(5) solar masses.WD-TDEs are considered to generate more powerful and short-lived flares,but their evidence has been lacking.Here we report observations of a fast and luminous X-ray transient EP250702a detected by Einstein Probe.Its one-day-long X-ray peak as luminous as 10^(47−49) erg s^(−1) showed strong recurrent flares with hard spectra extending to several tens of MeV gamma-rays,as detected by Fermi/GBM and Konus-Wind,indicating relativistic jet emission.The jet's X-rays dropped sharply from 3×10^(49) erg s^(−1) to around 1044 erg s^(−1) within 20 days(10 days in the source rest frame).These characteristics are inconsistent with any previously known transient phenomena.We suggest that this fast-evolving event over the unprecedentedly short timescale arises likely from disruption of a WD by an IMBH.At late times,a soft component progressively dominates the X-ray spectrum,reaching a luminosity as high as 1044 erg s^(−1),which is consistent with being extreme super-Eddington emission from an accretion disk expected to form in an IMBH-WD TDE.WD-TDEs open a new window for investigating the elusive IMBHs and their surrounding stellar environments,and they are prime sources of gravitational waves in the band of space-based interferometers.展开更多
Lead halide perovskites have emerged as promising scintillators for X-ray imaging owing to their high Xray absorption efficiency,excellent luminescence properties,and facile synthesis.However,their intrinsic ionic nat...Lead halide perovskites have emerged as promising scintillators for X-ray imaging owing to their high Xray absorption efficiency,excellent luminescence properties,and facile synthesis.However,their intrinsic ionic nature poses a fundamental challenge in simultaneously achieving high photoluminescence efficiency and environmental robustness.Here,we introduce a multilevel encapsulation strategy by sequentially coating CsPbBr_(3)quantum dots(QDs)with Cs_(4)PbBr_(6),SiO_(2),and polydimethylsiloxane(PDMS),thereby synergistically enhancing both optical performance and stability.Cs_(4)PbBr_(6)effectively passivates surface defects of CsPbBr_(3)QDs,while the SiO_(2)and PDMS layers serve as protective barriers against moisture,heat,and radiation.The resulting CsPbBr_(3)@Cs_(4)PbBr_(6)/SiO_(2)/PDMS flexible films exhibit a high photoluminescence quantum yield of 85%,outstanding mechanical flexibility,and remarkable durability under stretching,bending,and compressing.Moreover,the films retain excellent emission stability under elevated temperatures,prolonged X-ray irradiation,and extended water immersion.X-ray imaging evaluations further demonstrate a spatial resolution of 12 lp/mm,enabling distortion-free imaging of curved objects,while their superior water resistance allows for long-term underwater X-ray imaging.This work highlights the critical role of hierarchical encapsulation in balancing luminescence efficiency and environmental stability,offering a viable pathway toward practical high-performance flexible perovskite scintillators.展开更多
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl...Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.展开更多
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi...Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.展开更多
Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investig...Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investigative procedure and obtain results makes it the first imaging modality used to unravel the different causes of acute abdominal conditions in children. The safety of abdominal x-ray in children makes it attractive for use in paediatric surgical practice as part of routine work-up for undifferentiated acute abdominal conditions and also to diagnose specific causes of acute abdomen in children. Setting: Olabisi Onabanjo University Teaching Hospital, Sagamu, Ogun State. Objectives: Evaluation of the role of plain abdominal x-ray in diagnosing common acute abdominal conditions in children. Materials and method: Patients admitted to the children emergency room, paediatric surgical wards, children’s ward and neonatal ward who had plain abdominal x-ray as part of their diagnostic work-up were included in the study. They were studied prospectively between March 2011 and April 2021. Results: Three Hundred and Ninety-nine patients who had plain abdominal x-rays as part of their diagnostic work-up were studied. Males were 240 while females were 159, a male to female ratio of 1.5:1. The patients were aged between 1 day to 16 years. Differential diagnoses made with plain abdominal x-ray were intestinal obstruction in 298, perforated viscus 69 patients, intra-abdominal masses 13 patients and location of intra-abdominal foreign body 14. Intestinal obstruction cases in which plain abdominal x-ray played a role in their diagnosis and management included the following: intussusception 66, neonatal sepsis 60, malrotation 48, intestinal atresia 42, anorectal malformation 32, hirschsprung’s disease in 30 cases, pyloric stenosis 24, obstructed hernia 22, post-operative adhesions 16 and intestinal helminthiasis 12. Perforated viscus accounted for 69 indications. Out of these indications, perforated gut in intussusception 19, perforated typhoid ileitis was responsible in 13 cases, gut perforation in blunt abdominal trauma 8, perforation in strangulated hernia 11 cases, perforated gut in malrotation 7, ceacal perforation in hirschsprugs disease 6 and colonic perforation in necrotizing enterocolitis 5 cases. Conclusion: Plain abdominal x-ray remains a role to play in the differential diagnosis and management of common paediatric acute abdominal conditions.展开更多
We conducted experiments of oversensing generation of pacemaker (PM) and X-irradiation direction dependency of PM, and examined the oversensing suppression method, using 8 different types of PMs. It was found out from...We conducted experiments of oversensing generation of pacemaker (PM) and X-irradiation direction dependency of PM, and examined the oversensing suppression method, using 8 different types of PMs. It was found out from this experiment that oversensing would occur when some conditions (X-irradiation direction, X-irradiation intensity) are met. Oversensing occurred with the most low irradiation conditions (kV × mA) when PM was irradiated at 90° (vertically to C-MOS;Complementary Metal Oxide Semiconductor). The acuter the angle of irradiation is (α > 90° < α), the higher the irradiation conditions (kV × mA) at which oversensing start to occur. In plain X-ray photography, oversensing was confirmed under the irradiation conditions of (cervical spine, thoracic spine, lateral thoracic spine, rib, shoulder joint, collarbone, humerus, and chest).Once the irradiation angle and irradiation conditions (kV × mA) are available, oversensing is predictable to some extent. Our findings will help to predict oversensing generation of plain X-ray photography and suppress oversensing. Oversensing can be suppressed in most of the radiography by lowering tube current to 100 mA, but a 1.0 mm High-Density Tungsten Sheet must be put on PM in high tube voltage radiography.展开更多
[目的/意义]苹果“冰糖心”又称水心病,是一种常见的果实病害,严重的水心病果会随着储藏时间的增加发生霉变,造成食品安全隐患。为实现不同等级水心病苹果快速无损检测,本研究旨在构建有效的分级与可溶性固形物(Soluble Solids Content,...[目的/意义]苹果“冰糖心”又称水心病,是一种常见的果实病害,严重的水心病果会随着储藏时间的增加发生霉变,造成食品安全隐患。为实现不同等级水心病苹果快速无损检测,本研究旨在构建有效的分级与可溶性固形物(Soluble Solids Content,SSC)预测模型。[方法]本研究选取了230个富士苹果,其中正常、轻度、中度、重度水心苹果数量分别为113、61、47和9个,分别采集了400~1000 nm范围的反射光谱和X射线计算机断层成像(X-ray Computed Tomography,X-ray CT)数据,并测定了SSC含量。[结果和讨论]SSC随水心程度加剧呈上升趋势,重度水心苹果呈现更高的光谱反射率,X-ray CT扫描成像观察到水心区域的组织体积平均密度高于健康组织,基于三维重建算法实现不同等级水心苹果内部水心组织可视化分布。基于偏最小二乘判别分析(Partial Least Squares Discriminant Analysis,PLSDA)构建的不同水心程度苹果果实分级模型建模集和测试集准确率分别为98.7%和95.9%;构建不同水心程度苹果果实SSC回归模型,校正集决定系数(Correlation Coefficient of Calibration,R_(C)^(2))为0.962,均方根误差(Root Mean Squares Error of Calibration,RMSEC)为0.264,测试集决定系数(Correlation Coefficient of Prediction,R_(P)^(2))为0.879,均方根误差(Root Mean Squares Error of Prediction,RMSEP)为0.435。[结论]该研究构建的不同水心程度苹果果实分级模型能够实现苹果不同等级水心病的预测,构建的不同水心程度苹果果实SSC回归模型能够较好地预测苹果果实的SSC,为苹果水心病无损检测和品质评估提供了有效方法。展开更多
Idiopathic pneumomediastinum is rare in children. Few cases of patients with pneumomediastinum show negative findings on X-ray examination. Chest computed tomography (CT) was very useful for the diagnosis and evaluati...Idiopathic pneumomediastinum is rare in children. Few cases of patients with pneumomediastinum show negative findings on X-ray examination. Chest computed tomography (CT) was very useful for the diagnosis and evaluation of the extent of pneumomediastinum. We report here a case of idiopathic pneumomediastinum in a 15-year-old boy who exhibited no significant chest X-ray finding. The patient was referred to our institute for the further evaluation of pre-cordial pain and breathing difficulty. Precordial pain suddenly developed, when he was carrying a portable shrine on his shoulder (day of onset). He was admitted to another institute 3 days after onset because of worsening precordial pain. On admission, he presented with 98% saturation of hemoglobin in the peripheral blood under room air. Plain chest X-ray also revealed no abnormal findings. A half-dissolved gastrographin swallow showed no leakage of gastrographin from the pharynx and esophagus to the mediastinum, and no diverticulum within the esophagus. Plain chest CT revealed extensive emphysema around the trachea from the neck to the portion inferior to the carina of trachea. The patient was diagnosed with idiopathic pneumomediastinum because the cause was unclear. We decided to admit him to our institute under fasting conditions and rest. His symptoms improved 3 days after onset. The lesion had disap-peared 8 days after onset on chest CT. When young people experience precordial pain which increases on inspiration, we must consider pneumomediastinum in a differential diagnosis, and it is important to perform chest CT.展开更多
Indirect X-ray modulation imaging has been adopted in a number of solar missions and provided reconstructed X-ray images of solar flares that are of great scientific importance.However,the assessment of the image qual...Indirect X-ray modulation imaging has been adopted in a number of solar missions and provided reconstructed X-ray images of solar flares that are of great scientific importance.However,the assessment of the image quality of the reconstruction is still difficult,which is particularly useful for scheme design of X-ray imaging systems,testing and improvement of imaging algorithms,and scientific research of X-ray sources.Currently,there is no specified method to quantitatively evaluate the quality of X-ray image reconstruction and the point-spread function(PSF)of an X-ray imager.In this paper,we propose percentage proximity degree(PPD)by considering the imaging characteristics of X-ray image reconstruction and in particular,sidelobes and their effects on imaging quality.After testing a variety of imaging quality assessments in six aspects,we utilized the technique for order preference by similarity to ideal solution to the indices that meet the requirements.Then we develop the final quality index for X-ray image reconstruction,QuIX,which consists of the selected indices and the new PPD.QuIX performs well in a series of tests,including assessment of instrument PSF and simulation tests under different grid configurations,as well as imaging tests with RHESSI data.It is also a useful tool for testing of imaging algorithms,and determination of imaging parameters for both RHESSI and ASO-S/Hard X-ray Imager,such as field of view,beam width factor,and detector selection.展开更多
Black soil is essential for maintaining regional food security and promoting global agricultural production.Understanding the weathering process of parent material and the accumulation of organic carbon is crucial to ...Black soil is essential for maintaining regional food security and promoting global agricultural production.Understanding the weathering process of parent material and the accumulation of organic carbon is crucial to comprehending the developmental history and future trends of black soil,especially against the background of large-scale global cultivation and climate change.Although the importance of black soil formation and evolution cannot be ignored,the relevant research is still very scarce.In this study,a typical eight-meter-deep soil core was collected from the Keshan area of the Songnen Plain,Northeast China,where surface black soil developed on paleo-sediments.Using^(14)C dating,the formation age of the black soil was determined.Based on the characteristics of the geochemical composition,grain size and the magnetic susceptibility of the sediments,it was demonstrated that the black soil and its parent material originated from reworked loess.Furthermore,the mass transfer coefficient(τ)of some elements was determined,in order to explore the soil weathering process.By calculating the transported amount of alkaline and alkaline-earth elements,the weathering rate of parent material to black soil was found to be weak,at 0.16 kEq·ha^(-1)·year^(-1).Combining the results of dating and carbon density in the different layers of black soil,the accumulation rate of organic carbon was determined as follows:rapidly increasing in the initial period of 13.2-2.2 ka,reaching its maximum average value of 34.0 g·cm^(-2)·a^(-1)at 2.2-0.8 ka,then showing a decreasing trend with an average value of-77.5 g·cm^(-2)·a^(-1).Compared with regional climate change,Keshan black soil has developed under a colder and wetter climate during the Holocene.Predictably,ongoing global warming may lead to the degradation of black soils in the Songnen Plain,as well as in other regions.Our results will enrich geological knowledge of black soil formation and future evolutionary trends.展开更多
BACKGROUND In pediatric age group patients(<18 years old)treated operatively for distal radius/both bone fractures extending imaging beyond the initial postoperative period-particularly in uncomplicated cases-appea...BACKGROUND In pediatric age group patients(<18 years old)treated operatively for distal radius/both bone fractures extending imaging beyond the initial postoperative period-particularly in uncomplicated cases-appears to provide limited additional benefit.AIM To determine the necessary number of follow-up X-rays to use resources efficiently.METHODS Participants included in this study are pediatric age group patients who were treated operatively for distal radius/both bone fractures and were identified from a prospected collected data from the operating room database between the years 2009 and 2017.The data in the study included patients who had distal radius fractures and underwent fixation surgery(n=88).RESULTS When assessing the difference in the odds of conducting 1 or less X-ray compared to 2 or more X-rays in regard to the type of fixation,the only significant difference is the closed reduction fixation method.Patients who underwent closed reduction method procedure have significantly lower odds of having 2 more X-rays compared to those who didn’t have closed reduction method.Open reduction,internal fixation,and other fixation methods(close reduction and internal fixation,debridement,or epiphysiodesis)have higher odds of having two or more X-rays compared to patients who did not receive these methods;however,these odds are not statistically significant.CONCLUSION The findings of this study reveal notable absence of a statistically significant association between the frequency of postoperative X-rays and the outcome of children with distal radius fractures.展开更多
Imaging observations of solar X-ray bursts can reveal details of the energy release process and particle acceleration in flares.Most hard X-ray imagers make use of the modulation-based Fourier transform imaging method...Imaging observations of solar X-ray bursts can reveal details of the energy release process and particle acceleration in flares.Most hard X-ray imagers make use of the modulation-based Fourier transform imaging method,an indirect imaging technique that requires algorithms to reconstruct and optimize images.During the last decade,a variety of algorithms have been developed and improved.However,it is difficult to quantitatively evaluate the image quality of different solutions without a true,reference image of observation.How to choose the values of imaging parameters for these algorithms to get the best performance is also an open question.In this study,we present a detailed test of the characteristics of these algorithms,imaging dynamic range and a crucial parameter for the CLEAN method,clean beam width factor(CBWF).We first used SDO/AIA EUV images to compute DEM maps and calculate thermal X-ray maps.Then these realistic sources and several types of simulated sources are used as the ground truth in the imaging simulations for both RHESSI and ASO-S/HXI.The different solutions are evaluated quantitatively by a number of means.The overall results suggest that EM,PIXON,and CLEAN are exceptional methods for sidelobe elimination,producing images with clear source details.Although MEM_GE,MEM_NJIT,VIS_WV and VIS_CS possess fast imaging processes and generate good images,they too possess associated imperfections unique to each method.The two forward fit algorithms,VF and FF,perform differently,and VF appears to be more robust and useful.We also demonstrated the imaging capability of HXI and available HXI algorithms.Furthermore,the effect of CBWF on image quality was investigated,and the optimal settings for both RHESSI and HXI were proposed.展开更多
The main scientific payload of Macao Science Satellite-1B is a solar soft X-ray detection unit.To obtain an accurate solar X-ray spectrum,we have designed low-noise,high-throughput electronics.Solar radiation is detec...The main scientific payload of Macao Science Satellite-1B is a solar soft X-ray detection unit.To obtain an accurate solar X-ray spectrum,we have designed low-noise,high-throughput electronics.Solar radiation is detected using a low-leakage silicon drift detector(SDD),which is cooled to-30℃.The SDD output is processed using two parallel shaping amplifiers with peaking times of 315 ns and 65 ns.The amplifiers are designed using two-pole multiple-feedback active low-pass filters optimized to achieve a Bessel response.The differential output of the shaping amplifier generates a bipolar signal.The phase of the differential stage is tuned to ensure zero crossing corresponding to the peak of the shaping amplifier.A high-speed switch is inserted between the shaping amplifier and the peak-hold capacitor,and the peak value is maintained by turning off the switch.Fast and slow peak-hold circuits share a common ADC via time-division multiplexing.Both peak values are sampled for space-background rejection.Traditional pile-up detection methods cannot distinguish pulses that overlap in a fast channel.In this study,the differential of the“fast shaping”is selected,enabling the distinction of events separated by as little as 65ns,which is crucial for solar flare detection.The energy resolution is measured to be 138 eV at 5.90 keV.The centroid drift is less than 3.6 eV between-5℃ and 20℃.Compared with other solar X-ray instruments,this study demonstrates improved energy resolution with a lower peaking time,indicating a higher solar flare detection capability.展开更多
Using the new soft X-ray data from the Macao Science Satellite-1,we studied a solar flare that occurred on 22 June 2023.We found that the centroids of the Ca(around 3.9 keV)and Fe(around 6.7 keV)line features exhibit ...Using the new soft X-ray data from the Macao Science Satellite-1,we studied a solar flare that occurred on 22 June 2023.We found that the centroids of the Ca(around 3.9 keV)and Fe(around 6.7 keV)line features exhibit a rapid shift toward higher energy channels during the flare's rising phase,followed by a gradual decrease during the decay phase.Through precise energy calibration,the centroids are determined with high accuracy.Temperature and velocity are then self-consistently derived by comparing the centroids with those calculated from the synthesized line features using the latest CHIANTI atomic database(ver.10.1).The calculated maximum velocity reaches up to 710±60 km s-1,which significantly exceeds the previously reported values.Our results suggest that the entire shift of soft X-ray lines may occur during the process of chromospheric evaporation.展开更多
During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a rest...During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a restrictive link,closely associated with viscosity and the thickness of liquid slag.In contrast to two-dimensional surface observation,three-dimensional(3D)analysis method can offer a more intuitive,accurate,and comprehensive information.Therefore,this study employs a 3D X-ray microscope(3D-XRM)to obtained spatial distribution and 3D morphological characteristics of residual bubbles in mold flux under different basicity of liquid slag,different temperatures,and different holding times.The results indicate that as basicity of slag increases from 0.52 to 1.03,temperature increases from 1423 to 1573 K,the viscosity of slag decreases,the floating rate of bubbles increases.In addition,when holding time increases from 10 to 30 s,the bubbles floating distance increases,and the volume fraction and average equivalent sphere diameter of the bubbles solidified in the mold flux gradually decreases.In one word,increasing the basicity,temperature,and holding time leading to an increase in the removal rate of bubbles especially for the large.These findings of bubbles escape behavior provide valuable insights into optimizing low basicity mold flux for high-Mn high-Al steels.展开更多
基金supported in part by the National Natural Science Foundation of China(Nos.12305349,12235006,12027812)Shenzhen Science and Technology Program(No.JSGGKQTD20210831174329010)Guangdong Basic and Applied Basic Research Foundation(No.2021TQ06Y108).
文摘This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation transfer function(MTF),and detective quantum efficiency(DQE)of the DL-FPD are evaluated numerically using a linear cascade model.In addition,both the single-crystal(SC)and polycrystalline(PC)structures of MAPbI_(3)are investigated,along with various other key parameters such as the material thickness,electric field strength,X-ray beam spectrum,and electronic readout noise.The results demonstrate that SC perovskite consistently exhibits better performance than PC perovskite owing to fewer material defects.Increasing the layer thickness may decrease the MTF,but can also enhance the sensitivity and DQE.Moreover,appropriately increasing the external electric field within the material can improve the sensitivity,MTF,and DQE.Finally,reducing the electronic readout noise can significantly enhance the DQE for low-dose imaging.This study demonstrates the potential of high-quality dual-energy X-ray imaging using direct-conversion perovskite DL-FPDs.
基金supported by the National Natural Science Foundation of China(No.12175295)the National Key R&D Program of China(2021YFA1601000)the Shanghai Municipal Science and Technology Major Project。
文摘With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this study,the effects of X-ray beam size and photon energy on the accuracy of critical dimension measurements were investigated.Critical dimensions measured using beams with different spot sizes showed different deviations from the expected values.Beam sizes that were either too large or too small did not improve confidence intervals.As the incident energy increased,the X-ray transmission rate increased,while the scattering cross section decreased,resulting in a gradual decrease in the signal-to-noise ratio of the diffraction peaks,which reduced the accuracy of the CD-SAXS measurements.An optimal accuracy was obtained at 12 keV with a smaller beam size.Using an effective trapezoid model,the results yielded an average pitch of 100.4±0.2 nm,width of 49.8±0.2 nm,height of 130.0±0.2 nm,and a sidewall angle below 1.1°±0.1°.These results provide crucial guidance for the future development of CD-SAXS laboratories and the construction of X-ray machines as well as robust support for research in related fields.
基金funded by the National Natural Science Foundation of China(NNSFC)under Grant Numbers 42322408,42188101,and 42441809Additional support was provided by the Climbing Program of the National Space Science Center(NSSC,Grant No.E4PD3005)as well as the Specialized Research Fund for State Key Laboratories of China.
文摘A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-dimensional cusp boundary from a two-dimensional X-ray image because the detected X-ray signals will be integrated along the line of sight.In this work,a global magnetohydrodynamic code was used to simulate the X-ray images and photon count images,assuming an interplanetary magnetic field with a pure Bz component.The assumption of an elliptic cusp boundary at a given altitude was used to trace the equatorward and poleward boundaries of the cusp from a simulated X-ray image.The average discrepancy was less than 0.1 RE.To reduce the influence of instrument effects and cosmic X-ray backgrounds,image denoising was considered before applying the method above to SXI photon count images.The cusp boundaries were reasonably reconstructed from the noisy X-ray image.
基金Project(2023YFB4606200)supported by the National Key Research and Development Program of ChinaProject(2023-SSRF-HZ-503114-2)supported by Shanghai Synchrotron Radiation Facility,Instrument BL16U2,China。
文摘This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification.
基金supported by National Natural Science Foundation of China(61921002 and 92163204)。
文摘Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics,and free electron radiation devices.Particularly,they are promising platforms for studying thermionic emission.It is illustrated that using vdW heterostructure-based thermionic emission can enhance heat transfer in vacuum devices.As a proof of concept,the approach is demonstrated to offer a promising solution for the long-standing overheating issue in X-ray tubes.Specifically,it is shown that the saturated target temperature of a 2000 W X-ray tube can be reduced from around 1200℃ to 490℃.Additionally,it is also demonstrated that by reducing the height of the Schottky barrier formed in the vdW heterostructures,the thermionic cooling performance can be enhanced.The findings pave the way for the development of high-power X-ray tubes.
文摘Stars getting close enough to black holes(BHs)can be torn apart by strong tidal forces,producing electromagnetic flares.To date,more than 100 tidal disruption events(TDEs)have been observed,each involving invariably normal gaseous stars whose debris falls onto the BH,sustaining the flares over years.White dwarfs(WDs),which are the most prevalent compact stars and a million times denser-and therefore tougher-than gaseous stars,can only be disrupted by intermediate-mass black holes(IMBHs)of 10^(2)–10^(5) solar masses.WD-TDEs are considered to generate more powerful and short-lived flares,but their evidence has been lacking.Here we report observations of a fast and luminous X-ray transient EP250702a detected by Einstein Probe.Its one-day-long X-ray peak as luminous as 10^(47−49) erg s^(−1) showed strong recurrent flares with hard spectra extending to several tens of MeV gamma-rays,as detected by Fermi/GBM and Konus-Wind,indicating relativistic jet emission.The jet's X-rays dropped sharply from 3×10^(49) erg s^(−1) to around 1044 erg s^(−1) within 20 days(10 days in the source rest frame).These characteristics are inconsistent with any previously known transient phenomena.We suggest that this fast-evolving event over the unprecedentedly short timescale arises likely from disruption of a WD by an IMBH.At late times,a soft component progressively dominates the X-ray spectrum,reaching a luminosity as high as 1044 erg s^(−1),which is consistent with being extreme super-Eddington emission from an accretion disk expected to form in an IMBH-WD TDE.WD-TDEs open a new window for investigating the elusive IMBHs and their surrounding stellar environments,and they are prime sources of gravitational waves in the band of space-based interferometers.
基金supported by the National Natural Science Foundation of China(52250060,62274135,62288102,12504473)the China Postdoctoral Science Foundation(2025M773420,2024M764250)+1 种基金the Key Project of Ningbo Natural Science Foundation(20221JCGY01049)the Postdoctoral Fellowship Program of the China Postdoctoral Science Foundation(CPSF)(GZB20230975)。
文摘Lead halide perovskites have emerged as promising scintillators for X-ray imaging owing to their high Xray absorption efficiency,excellent luminescence properties,and facile synthesis.However,their intrinsic ionic nature poses a fundamental challenge in simultaneously achieving high photoluminescence efficiency and environmental robustness.Here,we introduce a multilevel encapsulation strategy by sequentially coating CsPbBr_(3)quantum dots(QDs)with Cs_(4)PbBr_(6),SiO_(2),and polydimethylsiloxane(PDMS),thereby synergistically enhancing both optical performance and stability.Cs_(4)PbBr_(6)effectively passivates surface defects of CsPbBr_(3)QDs,while the SiO_(2)and PDMS layers serve as protective barriers against moisture,heat,and radiation.The resulting CsPbBr_(3)@Cs_(4)PbBr_(6)/SiO_(2)/PDMS flexible films exhibit a high photoluminescence quantum yield of 85%,outstanding mechanical flexibility,and remarkable durability under stretching,bending,and compressing.Moreover,the films retain excellent emission stability under elevated temperatures,prolonged X-ray irradiation,and extended water immersion.X-ray imaging evaluations further demonstrate a spatial resolution of 12 lp/mm,enabling distortion-free imaging of curved objects,while their superior water resistance allows for long-term underwater X-ray imaging.This work highlights the critical role of hierarchical encapsulation in balancing luminescence efficiency and environmental stability,offering a viable pathway toward practical high-performance flexible perovskite scintillators.
基金supports from the National Natural Science Foundation of China(22375220,U2001214,22471302)the Guangdong Basic and Applied Basic Research Foundation(2024B1515020101)Open Project Fund from State Key Laboratory of Optoelectronic Materials and Technologies(OEMT-2024-KF-08).
文摘Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.
基金supported by the NSFC under Grant No.62474169the National Key Research and Development Program of China under Grant No.2024YFB3212200the funding from USTC under Grant Nos.WK2100000025,KY2190000003,and KY2190000006。
文摘Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.
文摘Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investigative procedure and obtain results makes it the first imaging modality used to unravel the different causes of acute abdominal conditions in children. The safety of abdominal x-ray in children makes it attractive for use in paediatric surgical practice as part of routine work-up for undifferentiated acute abdominal conditions and also to diagnose specific causes of acute abdomen in children. Setting: Olabisi Onabanjo University Teaching Hospital, Sagamu, Ogun State. Objectives: Evaluation of the role of plain abdominal x-ray in diagnosing common acute abdominal conditions in children. Materials and method: Patients admitted to the children emergency room, paediatric surgical wards, children’s ward and neonatal ward who had plain abdominal x-ray as part of their diagnostic work-up were included in the study. They were studied prospectively between March 2011 and April 2021. Results: Three Hundred and Ninety-nine patients who had plain abdominal x-rays as part of their diagnostic work-up were studied. Males were 240 while females were 159, a male to female ratio of 1.5:1. The patients were aged between 1 day to 16 years. Differential diagnoses made with plain abdominal x-ray were intestinal obstruction in 298, perforated viscus 69 patients, intra-abdominal masses 13 patients and location of intra-abdominal foreign body 14. Intestinal obstruction cases in which plain abdominal x-ray played a role in their diagnosis and management included the following: intussusception 66, neonatal sepsis 60, malrotation 48, intestinal atresia 42, anorectal malformation 32, hirschsprung’s disease in 30 cases, pyloric stenosis 24, obstructed hernia 22, post-operative adhesions 16 and intestinal helminthiasis 12. Perforated viscus accounted for 69 indications. Out of these indications, perforated gut in intussusception 19, perforated typhoid ileitis was responsible in 13 cases, gut perforation in blunt abdominal trauma 8, perforation in strangulated hernia 11 cases, perforated gut in malrotation 7, ceacal perforation in hirschsprugs disease 6 and colonic perforation in necrotizing enterocolitis 5 cases. Conclusion: Plain abdominal x-ray remains a role to play in the differential diagnosis and management of common paediatric acute abdominal conditions.
文摘We conducted experiments of oversensing generation of pacemaker (PM) and X-irradiation direction dependency of PM, and examined the oversensing suppression method, using 8 different types of PMs. It was found out from this experiment that oversensing would occur when some conditions (X-irradiation direction, X-irradiation intensity) are met. Oversensing occurred with the most low irradiation conditions (kV × mA) when PM was irradiated at 90° (vertically to C-MOS;Complementary Metal Oxide Semiconductor). The acuter the angle of irradiation is (α > 90° < α), the higher the irradiation conditions (kV × mA) at which oversensing start to occur. In plain X-ray photography, oversensing was confirmed under the irradiation conditions of (cervical spine, thoracic spine, lateral thoracic spine, rib, shoulder joint, collarbone, humerus, and chest).Once the irradiation angle and irradiation conditions (kV × mA) are available, oversensing is predictable to some extent. Our findings will help to predict oversensing generation of plain X-ray photography and suppress oversensing. Oversensing can be suppressed in most of the radiography by lowering tube current to 100 mA, but a 1.0 mm High-Density Tungsten Sheet must be put on PM in high tube voltage radiography.
文摘[目的/意义]苹果“冰糖心”又称水心病,是一种常见的果实病害,严重的水心病果会随着储藏时间的增加发生霉变,造成食品安全隐患。为实现不同等级水心病苹果快速无损检测,本研究旨在构建有效的分级与可溶性固形物(Soluble Solids Content,SSC)预测模型。[方法]本研究选取了230个富士苹果,其中正常、轻度、中度、重度水心苹果数量分别为113、61、47和9个,分别采集了400~1000 nm范围的反射光谱和X射线计算机断层成像(X-ray Computed Tomography,X-ray CT)数据,并测定了SSC含量。[结果和讨论]SSC随水心程度加剧呈上升趋势,重度水心苹果呈现更高的光谱反射率,X-ray CT扫描成像观察到水心区域的组织体积平均密度高于健康组织,基于三维重建算法实现不同等级水心苹果内部水心组织可视化分布。基于偏最小二乘判别分析(Partial Least Squares Discriminant Analysis,PLSDA)构建的不同水心程度苹果果实分级模型建模集和测试集准确率分别为98.7%和95.9%;构建不同水心程度苹果果实SSC回归模型,校正集决定系数(Correlation Coefficient of Calibration,R_(C)^(2))为0.962,均方根误差(Root Mean Squares Error of Calibration,RMSEC)为0.264,测试集决定系数(Correlation Coefficient of Prediction,R_(P)^(2))为0.879,均方根误差(Root Mean Squares Error of Prediction,RMSEP)为0.435。[结论]该研究构建的不同水心程度苹果果实分级模型能够实现苹果不同等级水心病的预测,构建的不同水心程度苹果果实SSC回归模型能够较好地预测苹果果实的SSC,为苹果水心病无损检测和品质评估提供了有效方法。
文摘Idiopathic pneumomediastinum is rare in children. Few cases of patients with pneumomediastinum show negative findings on X-ray examination. Chest computed tomography (CT) was very useful for the diagnosis and evaluation of the extent of pneumomediastinum. We report here a case of idiopathic pneumomediastinum in a 15-year-old boy who exhibited no significant chest X-ray finding. The patient was referred to our institute for the further evaluation of pre-cordial pain and breathing difficulty. Precordial pain suddenly developed, when he was carrying a portable shrine on his shoulder (day of onset). He was admitted to another institute 3 days after onset because of worsening precordial pain. On admission, he presented with 98% saturation of hemoglobin in the peripheral blood under room air. Plain chest X-ray also revealed no abnormal findings. A half-dissolved gastrographin swallow showed no leakage of gastrographin from the pharynx and esophagus to the mediastinum, and no diverticulum within the esophagus. Plain chest CT revealed extensive emphysema around the trachea from the neck to the portion inferior to the carina of trachea. The patient was diagnosed with idiopathic pneumomediastinum because the cause was unclear. We decided to admit him to our institute under fasting conditions and rest. His symptoms improved 3 days after onset. The lesion had disap-peared 8 days after onset on chest CT. When young people experience precordial pain which increases on inspiration, we must consider pneumomediastinum in a differential diagnosis, and it is important to perform chest CT.
基金supported by the National Natural Science Foundation of China(NSFC)12333010the National Key R&D Program of China 2022YFF0503002+3 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(grant No.XDB0560000)the NSFC 11921003supported by the Prominent Postdoctoral Project of Jiangsu Province(2023ZB304)supported by the Strategic Priority Research Program on Space Science,the Chinese Academy of Sciences,grant No.XDA15320000.
文摘Indirect X-ray modulation imaging has been adopted in a number of solar missions and provided reconstructed X-ray images of solar flares that are of great scientific importance.However,the assessment of the image quality of the reconstruction is still difficult,which is particularly useful for scheme design of X-ray imaging systems,testing and improvement of imaging algorithms,and scientific research of X-ray sources.Currently,there is no specified method to quantitatively evaluate the quality of X-ray image reconstruction and the point-spread function(PSF)of an X-ray imager.In this paper,we propose percentage proximity degree(PPD)by considering the imaging characteristics of X-ray image reconstruction and in particular,sidelobes and their effects on imaging quality.After testing a variety of imaging quality assessments in six aspects,we utilized the technique for order preference by similarity to ideal solution to the indices that meet the requirements.Then we develop the final quality index for X-ray image reconstruction,QuIX,which consists of the selected indices and the new PPD.QuIX performs well in a series of tests,including assessment of instrument PSF and simulation tests under different grid configurations,as well as imaging tests with RHESSI data.It is also a useful tool for testing of imaging algorithms,and determination of imaging parameters for both RHESSI and ASO-S/Hard X-ray Imager,such as field of view,beam width factor,and detector selection.
基金financially supported by the Science and Technology Innovation Foundation of the Command Center of Integrated Natural Resources Survey Center(KC20230002)the China Geological Survey Project(DD20230471,DD20220855 and DD20243282)+1 种基金the National Natural Science Foundation of China(41872100)the National Key R&D Plan(2022YFC2903402)。
文摘Black soil is essential for maintaining regional food security and promoting global agricultural production.Understanding the weathering process of parent material and the accumulation of organic carbon is crucial to comprehending the developmental history and future trends of black soil,especially against the background of large-scale global cultivation and climate change.Although the importance of black soil formation and evolution cannot be ignored,the relevant research is still very scarce.In this study,a typical eight-meter-deep soil core was collected from the Keshan area of the Songnen Plain,Northeast China,where surface black soil developed on paleo-sediments.Using^(14)C dating,the formation age of the black soil was determined.Based on the characteristics of the geochemical composition,grain size and the magnetic susceptibility of the sediments,it was demonstrated that the black soil and its parent material originated from reworked loess.Furthermore,the mass transfer coefficient(τ)of some elements was determined,in order to explore the soil weathering process.By calculating the transported amount of alkaline and alkaline-earth elements,the weathering rate of parent material to black soil was found to be weak,at 0.16 kEq·ha^(-1)·year^(-1).Combining the results of dating and carbon density in the different layers of black soil,the accumulation rate of organic carbon was determined as follows:rapidly increasing in the initial period of 13.2-2.2 ka,reaching its maximum average value of 34.0 g·cm^(-2)·a^(-1)at 2.2-0.8 ka,then showing a decreasing trend with an average value of-77.5 g·cm^(-2)·a^(-1).Compared with regional climate change,Keshan black soil has developed under a colder and wetter climate during the Holocene.Predictably,ongoing global warming may lead to the degradation of black soils in the Songnen Plain,as well as in other regions.Our results will enrich geological knowledge of black soil formation and future evolutionary trends.
文摘BACKGROUND In pediatric age group patients(<18 years old)treated operatively for distal radius/both bone fractures extending imaging beyond the initial postoperative period-particularly in uncomplicated cases-appears to provide limited additional benefit.AIM To determine the necessary number of follow-up X-rays to use resources efficiently.METHODS Participants included in this study are pediatric age group patients who were treated operatively for distal radius/both bone fractures and were identified from a prospected collected data from the operating room database between the years 2009 and 2017.The data in the study included patients who had distal radius fractures and underwent fixation surgery(n=88).RESULTS When assessing the difference in the odds of conducting 1 or less X-ray compared to 2 or more X-rays in regard to the type of fixation,the only significant difference is the closed reduction fixation method.Patients who underwent closed reduction method procedure have significantly lower odds of having 2 more X-rays compared to those who didn’t have closed reduction method.Open reduction,internal fixation,and other fixation methods(close reduction and internal fixation,debridement,or epiphysiodesis)have higher odds of having two or more X-rays compared to patients who did not receive these methods;however,these odds are not statistically significant.CONCLUSION The findings of this study reveal notable absence of a statistically significant association between the frequency of postoperative X-rays and the outcome of children with distal radius fractures.
基金supported by the National Key R&D Program of China 2022YFF0503002the National Natural Science Foundation of China(NSFC,Grant Nos.12333010 and 12233012)+2 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(grant No.XDB0560000)supported by the Prominent Postdoctoral Project of Jiangsu Province(2023ZB304)supported by the Strategic Priority Research Program on Space Science,the Chinese Academy of Sciences,grant No.XDA15320000.
文摘Imaging observations of solar X-ray bursts can reveal details of the energy release process and particle acceleration in flares.Most hard X-ray imagers make use of the modulation-based Fourier transform imaging method,an indirect imaging technique that requires algorithms to reconstruct and optimize images.During the last decade,a variety of algorithms have been developed and improved.However,it is difficult to quantitatively evaluate the image quality of different solutions without a true,reference image of observation.How to choose the values of imaging parameters for these algorithms to get the best performance is also an open question.In this study,we present a detailed test of the characteristics of these algorithms,imaging dynamic range and a crucial parameter for the CLEAN method,clean beam width factor(CBWF).We first used SDO/AIA EUV images to compute DEM maps and calculate thermal X-ray maps.Then these realistic sources and several types of simulated sources are used as the ground truth in the imaging simulations for both RHESSI and ASO-S/HXI.The different solutions are evaluated quantitatively by a number of means.The overall results suggest that EM,PIXON,and CLEAN are exceptional methods for sidelobe elimination,producing images with clear source details.Although MEM_GE,MEM_NJIT,VIS_WV and VIS_CS possess fast imaging processes and generate good images,they too possess associated imperfections unique to each method.The two forward fit algorithms,VF and FF,perform differently,and VF appears to be more robust and useful.We also demonstrated the imaging capability of HXI and available HXI algorithms.Furthermore,the effect of CBWF on image quality was investigated,and the optimal settings for both RHESSI and HXI were proposed.
基金supported by the National Natural Science Foundation of China(No.12035020)National Key Scientific Instrument and Equipment Development Projects of China(No.42327802).
文摘The main scientific payload of Macao Science Satellite-1B is a solar soft X-ray detection unit.To obtain an accurate solar X-ray spectrum,we have designed low-noise,high-throughput electronics.Solar radiation is detected using a low-leakage silicon drift detector(SDD),which is cooled to-30℃.The SDD output is processed using two parallel shaping amplifiers with peaking times of 315 ns and 65 ns.The amplifiers are designed using two-pole multiple-feedback active low-pass filters optimized to achieve a Bessel response.The differential output of the shaping amplifier generates a bipolar signal.The phase of the differential stage is tuned to ensure zero crossing corresponding to the peak of the shaping amplifier.A high-speed switch is inserted between the shaping amplifier and the peak-hold capacitor,and the peak value is maintained by turning off the switch.Fast and slow peak-hold circuits share a common ADC via time-division multiplexing.Both peak values are sampled for space-background rejection.Traditional pile-up detection methods cannot distinguish pulses that overlap in a fast channel.In this study,the differential of the“fast shaping”is selected,enabling the distinction of events separated by as little as 65ns,which is crucial for solar flare detection.The energy resolution is measured to be 138 eV at 5.90 keV.The centroid drift is less than 3.6 eV between-5℃ and 20℃.Compared with other solar X-ray instruments,this study demonstrates improved energy resolution with a lower peaking time,indicating a higher solar flare detection capability.
文摘Using the new soft X-ray data from the Macao Science Satellite-1,we studied a solar flare that occurred on 22 June 2023.We found that the centroids of the Ca(around 3.9 keV)and Fe(around 6.7 keV)line features exhibit a rapid shift toward higher energy channels during the flare's rising phase,followed by a gradual decrease during the decay phase.Through precise energy calibration,the centroids are determined with high accuracy.Temperature and velocity are then self-consistently derived by comparing the centroids with those calculated from the synthesized line features using the latest CHIANTI atomic database(ver.10.1).The calculated maximum velocity reaches up to 710±60 km s-1,which significantly exceeds the previously reported values.Our results suggest that the entire shift of soft X-ray lines may occur during the process of chromospheric evaporation.
基金financially supported by the National Natural Science Foundation of China(Nos.52274315 and 52374320)the Fundamental Research Funds for the Central Universities(Nos.FRF-TP-22-011A1 and FRF-DF22-16)。
文摘During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a restrictive link,closely associated with viscosity and the thickness of liquid slag.In contrast to two-dimensional surface observation,three-dimensional(3D)analysis method can offer a more intuitive,accurate,and comprehensive information.Therefore,this study employs a 3D X-ray microscope(3D-XRM)to obtained spatial distribution and 3D morphological characteristics of residual bubbles in mold flux under different basicity of liquid slag,different temperatures,and different holding times.The results indicate that as basicity of slag increases from 0.52 to 1.03,temperature increases from 1423 to 1573 K,the viscosity of slag decreases,the floating rate of bubbles increases.In addition,when holding time increases from 10 to 30 s,the bubbles floating distance increases,and the volume fraction and average equivalent sphere diameter of the bubbles solidified in the mold flux gradually decreases.In one word,increasing the basicity,temperature,and holding time leading to an increase in the removal rate of bubbles especially for the large.These findings of bubbles escape behavior provide valuable insights into optimizing low basicity mold flux for high-Mn high-Al steels.