期刊文献+
共找到305篇文章
< 1 2 16 >
每页显示 20 50 100
Optical characterization of X-ray polymer refractive lenses using a microfocus X-ray grating interferometer
1
作者 Dongxu Qin Lian Xue +5 位作者 Yifan Ding Ziwen Huang Lei Yang Zhaofeng Kang Keyi Wang Shuai Zhao 《Chinese Optics Letters》 2025年第4期143-148,共6页
Two-photon polymerization lithography is a technique that provides hundreds of nanometer resolution and full geometric freedom.Several X-ray polymer refractive lenses created by this technique were characterized using... Two-photon polymerization lithography is a technique that provides hundreds of nanometer resolution and full geometric freedom.Several X-ray polymer refractive lenses created by this technique were characterized using differential phase contrast imaging(DPCI)with a microfocus X-ray grating interferometer.The beam deflection angle and wavefront phase shift of the X-ray beam through the lens were obtained.Comparative tests using synchrotron radiation sources showed that the system could measure the surface shape of X-ray refractive lenses with an accuracy of 0.4μm.This study is important for improving the fabrication process and focusing performance of X-ray refractive lenses. 展开更多
关键词 differential phase contrast imaging x-ray polymer refractive lens microfocus x-ray grating interferometer optical characterization
原文传递
Signal estimation bias in x-ray dark-field imaging using dual phase grating interferometer
2
作者 Zhi-Li Wang Zun Zhang +1 位作者 Heng Chen Xin Ge 《Chinese Physics B》 2025年第3期550-558,共9页
In x-ray dark-field imaging using dual phase grating interferometer,multi-contrast signals are extracted from a set of acquired phase-stepping data by using the least-squares fitting algorithm.The extracted mean inten... In x-ray dark-field imaging using dual phase grating interferometer,multi-contrast signals are extracted from a set of acquired phase-stepping data by using the least-squares fitting algorithm.The extracted mean intensity,amplitude and visibility signals may be intrinsically biased.However,it is still unclear how large these biases are and how the data acquisition parameters influence the biases in the extracted signals.This work set out to address these questions.Analytical expressions of the biases of the extracted signals were theoretically derived by using a second-order Taylor series expansion.Extensive numerical simulations were performed to validate the theoretical results.It is illustrated that while the estimated mean intensity signal is always unbiased,the estimated amplitude and visibility signals are both positively biased.While the biases of the estimated amplitude signals are proportional to the inverse of the total number of phase steps,the biases of the estimated visibility signals are inversely proportional to the product of the total number of phase steps and the mean number of photons counted per phase step.Meanwhile,it is demonstrated that the dependence of the biases on the mean visibility is quite different from that of Talbot-Lau interferometer due to the difference in the intensity model.We expect that these results can be useful for data acquisition optimizations and interpretation of x-ray dark-field images. 展开更多
关键词 x-ray imaging dual phase grating interferometer dark-field imaging signal bias
原文传递
Research on a compact and high sensitivity gas pressure sensor based on fiber Fabry-Pérot interferometer and Bragg grating
3
作者 LIU Qinpeng XING Meihua +2 位作者 YANG Di LIU Bo YAN Cheng 《Optoelectronics Letters》 2025年第6期321-327,共7页
A compact and highly sensitive gas pressure and temperature sensor based on Fabry-Pérot interferometer(FPI)and fiber Bragg grating(FBG)is proposed and demonstrated experimentally in this paper.The theoretical mod... A compact and highly sensitive gas pressure and temperature sensor based on Fabry-Pérot interferometer(FPI)and fiber Bragg grating(FBG)is proposed and demonstrated experimentally in this paper.The theoretical model for pressure and temperature sensing is established.Building on this foundation,a novel micro silicon cavity sensor structure sensitive to pressure is devised downstream of an FBG.The concept of separate measurement and the mechanisms enhancing pressure sensitivity are meticulously analyzed,and the corresponding samples are fabricated.The experimental results indicate that the pressure sensitivity of the sensor is-747.849 nm/MPa in 0—100 k Pa and its linearity is 99.7%and it maintains good stability in 150 min.The sensor offers the advantages of compact size,robust construction,easy fabrication,and high sensitivity,making it potentially valuable for micro-pressure application. 展开更多
关键词 fiber bragg grating fbg gas pressure sensor temperature sensor separate measurement fiber Bragg grating fiber Fabry P rot interferometer theoretical model pressure temperature sensing micro silicon cavity sensor structure
原文传递
Theory and verification of moiréfringes for x-ray three-phase grating interferometer 被引量:1
4
作者 单雨征 葛永帅 +5 位作者 杨君 郭大育 蔡学宝 刘晓珂 侯晓文 郭金川 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期532-540,共9页
Dual-phase and three-phase grating x-ray interference is a promising new technique for grating-based x-ray differential phase contrast imaging.Dual-phase grating interferometers have been relatively completely studied... Dual-phase and three-phase grating x-ray interference is a promising new technique for grating-based x-ray differential phase contrast imaging.Dual-phase grating interferometers have been relatively completely studied and discussed.In this paper,the corresponding imaging fringe formula of the three-phase grating interferometer is provided.At the same time,the similarities and differences between the three-phase grating interferometer and the dual-phase grating interferometer are investigated and verified,and that the three-phase grating interferometer can produce large-period moiréfringes without using the analyzing grating is demonstrated experimentally.Finally,a simple method of designing three-phase grating and multi-grating imaging systems from geometric optics based on the thin-lens theory of gratings is presented.These theoretical formulas and experimental results provide optimization tools for designing three-phase grating interferometer systems. 展开更多
关键词 x-ray phase contrast phase grating moiréfringe
原文传递
X-ray phase-sensitive microscope imaging with a grating interferometer:Theory and simulation
5
作者 Jiecheng Yang Peiping Zhu +2 位作者 Dong Liang Hairong Zheng Yongshuai Ge 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第9期652-657,共6页
A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imagin... A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imaging and the improved image contrast.By using this theory,several key parameters of phase contrast imaging can be predicted,for instance,the fringe visibility and period,and the conversion condition from the differential phase imaging(DPI)to the phase difference imaging(PDI).Additionally,numerical simulations are performed with certain x-ray optical components and imaging geometry.Comparison with the available experimental measurement[Appl.Phys.Lett.113063105(2018)]demonstrates the accuracy of this developed quantitative analysis method of x-ray phase-sensitive microscope imaging. 展开更多
关键词 x-ray phase contrast imaging x-ray microscope grating interferometer
原文传递
Experimental research on the feature of an x-ray Talbot–Lau interferometer versus tube accelerating voltage 被引量:3
6
作者 王圣浩 Margie P.Olbinado +7 位作者 Atsushi Momose 韩华杰 胡仁芳 王志立 高昆 张凯 朱佩平 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期673-678,共6页
X-ray Talbot-Lau interferometer has been used most widely to perform x-ray phase-contrast imaging with a con- ventional low-brilliance x-ray source, and it yields high-sensitivity phase and dark-field images of sample... X-ray Talbot-Lau interferometer has been used most widely to perform x-ray phase-contrast imaging with a con- ventional low-brilliance x-ray source, and it yields high-sensitivity phase and dark-field images of samples producing low absorption contrast, thus beating tremendous potential for future clinical diagnosis. In this work, by changing the accel- erating voltage of the x-ray tube from 35 kV to 45 kV, x-ray phase-contrast imaging of a test sample is performed at each integer value of the accelerating voltage to investigate the characteristic of an x-ray Talbot-Lau interferometer (located in the Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Japan) versus tube voltage. Ex- perimental results and data analysis show that within a range this x-ray Talbot-Lau interferometer is not sensitive to the accelerating voltage of the tube with a constant fringe visibility of ~ 44%. This x-ray Talbot-Lau interferometer research demonstrates the feasibility of a new dual energy phase-contrast x-ray imaging strategy and the possibility to collect a refraction spectrum. 展开更多
关键词 x-ray Talbot-Lau interferometer x-ray imaging PHASE-CONTRAST tube accelerating voltage x-ray tube
原文传递
Analysis of period and visibility of dual phase grating interferometer 被引量:2
7
作者 Jun Yang Jian-Heng Huang +4 位作者 Yao-Hu Lei Jing-Biao Zheng Yu-Zheng Shan Da-Yu Guo Jin-Chuan Guo 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第5期749-755,共7页
Dual phase grating interferometer may simultaneously achieve large field of view and high x-ray dose efficiency.Here,we develop a simple theoretical method to better understand the imaging process of the dual phase gr... Dual phase grating interferometer may simultaneously achieve large field of view and high x-ray dose efficiency.Here,we develop a simple theoretical method to better understand the imaging process of the dual phase grating interferometer.The derivation process of fringe period and the optimal visibility conditions of the dual phase grating interferometer are given in detail.Then,we theoretically prove that the fringe period and optimal visibility conditions of the dual phase grating interferometer include that of the Talbot interferometer.By comparing our experimental results with those of other researchers,we find that when the positions of phase gratings are far away from the positions where the fringe visibility is optimal,the fringe period of the dualπ-phase grating interferometer is twice the theoretical results under the illumination of polychromatic x-ray.This conclusion may explain the contradictory research results of dual phase grating interferometer among different researchers. 展开更多
关键词 phase contrast grating interferometer fringe period fringe visibility
原文传递
Quantitative coherence analysis of dual phase grating x-ray interferometry with source grating 被引量:1
8
作者 Zhi-Li Wang Rui-Cheng Zhou +4 位作者 Li-Ming Zhao Kun Ren Wen Xu Bo Liu Heng Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期595-600,共6页
Dual phase grating x-ray interferometry is compatible with common imaging detectors,and abandons the use of an absorption analyzer grating to reduce the radiation dose.When using x-ray tubes,an absorbing source gratin... Dual phase grating x-ray interferometry is compatible with common imaging detectors,and abandons the use of an absorption analyzer grating to reduce the radiation dose.When using x-ray tubes,an absorbing source grating must be introduced into the dual phase grating interferometer.In order to attain a high fringe visibility,in this work we conduct a quantitative coherence analysis of dual phase grating interferometry to find how the source grating affects the fringe visibility.Theoretical analysis shows that with the generalized Lau condition satisfied,the fringe visibility is influenced by the duty cycle of the source grating and the transmission through the grating bar.And the influence of the source grating profile on the fringe visibility is independent of the phase grating type.Numerical results illustrate that the maximum achievable fringe visibility decreases significantly with increasing transmission in the grating bar.Under a given transmission,one can always find an optimal duty cycle to maximize the fringe visibility.These results can be used as general guidelines for designing and optimizing dual phase grating x-ray interferometers for potential applications. 展开更多
关键词 x-ray imaging phase contrast grating interferometer fringe visibility
原文传递
Interferometers Utilizing Reversible X-ray-induced Chemical Changes in Poly(N-isopropylacrylamide)Microgels 被引量:1
9
作者 Ya-Jie Wang Ping Zhang +2 位作者 Michael J Serpe Hong Chen Liang Hu 《Chinese Journal of Polymer Science》 SCIE EI CAS CSCD 2024年第12期1915-1924,I0008,共11页
Photonic materials,which react to light,have garnered interest due to their capability to exhibit adjustable structural colors.Typically,light targets the UV,visible,or near-IR spectrums.In this study,microgel-based p... Photonic materials,which react to light,have garnered interest due to their capability to exhibit adjustable structural colors.Typically,light targets the UV,visible,or near-IR spectrums.In this study,microgel-based photonic materials that are capable of reversibly responding to Xrays have been engineered.To accomplish this,azobenzene(Azo)-containing poly(N-isopropylacrylamide)(pNiPAm)-based microgels are synthesized.Subsequently,ZnS scintillator and Cr/Au are applied on each side of the poly(methyl methacrylate(PMMA)substrate.Subsequently,the Azo MG monolayer is deposited onto the Au surface,followed by the deposition of an additional layer of Cr/Au.This process generates ZnS/PMMA/Cr/Au/Azo MG/Cr/Au or ZnS/Au-Azo MG-Au structure.Functioning as a typical interferometer,ZnS/Au-Azo MG-Au demonstrates tunable colors based on the separation distance between the two Au layers.The ZnS scintillator can absorb and convert X-rays into Uv light,initiating the transition of the Azo groups from a trans to a cis state.Consequently,this transition causes the Azo MG to swell.As Azo MG swells,the distance between the two Au layers increases,resulting in a red-shift of approximately 350 nm in the optical signal of the ZnS/Au-Azo MG-Au interferometer.Remarkably,this X-ray responsivity of the interferometer is reversible,as it returns to its initial state after being stored in the dark for 24 h.To demonstrate its capabilities,the ZnS/Au-Azo MG-Au interferometer successfully releases a drug when triggered by X-ray stimulation,thus validating its potential.The microgel-based interferometers hold significant promise for applications in chemoradiotherapy,radiobiology,and actuators in space. 展开更多
关键词 N-ISOPROPYLACRYLAMIDE Microgels interferometerS x-rays SCINTILLATORS
原文传递
Optical Fiber Bragg Grating Michelson Interferometer
10
作者 江毅 江天府 刘莉 《Journal of Beijing Institute of Technology》 EI CAS 2006年第4期448-450,共3页
A new Michelson interferometer based on fiber Bragg grating(FBG) is demonstrated. FBCs are used as reflectors, and the laser is replaced by a broadband source as input light in this interferometer. To demodulate the... A new Michelson interferometer based on fiber Bragg grating(FBG) is demonstrated. FBCs are used as reflectors, and the laser is replaced by a broadband source as input light in this interferometer. To demodulate the signals, a 3 × 3 coupler is used as a splitter. By combining with software demodulation, the outer interference can be obtained from the outputs of the interferometer. This kind of interferometer can also be wavelength-multiplexed easily by composing a series Michelson interferometer. The experiment results show that the clear interference fringe can be obtained by adjusting the path difference to make it less than interference length of FBG. The signals are also demodulated. 展开更多
关键词 Michelson interferometer fiber Bragg grating 3×3 coupler
在线阅读 下载PDF
Present Status of EUV Interferometer Development at the Research Center for Soft X-ray Microscopy
11
作者 Masaki Yamamoto, Tadashi Hatano, Minaji Furudate (Research Center for Soft X-ray Microscopy, Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Japan) 《光学精密工程》 EI CAS CSCD 2001年第5期405-410,共6页
A new interferometer for extreme ultraviolet (EUV) radiation with a laser produced plasma (LPP) laboratory source is under construction. The LPP source is operated with a Sn solid rod target on which pulsed YAG laser ... A new interferometer for extreme ultraviolet (EUV) radiation with a laser produced plasma (LPP) laboratory source is under construction. The LPP source is operated with a Sn solid rod target on which pulsed YAG laser is focused to produce high temperature plasma emitting EUV radiation. The source is equipped with a newly designed debris stopper protecting a condenser multilayer mirror from the particle debris of the target. The condenser mirror focuses the light onto an EUV beam-splitter to form transmitted and reflected paths for producing interference fringes of a sharing type. The optical configuration is of a common path based on a triangular path type with a focusing at the beam-splitter, which is enabled to produce fringes by a low coherence radiation with a standard optical quality beam-splitter. The fringes are recorded by an imaging plate with pixels as small as 25μm. The dynamic range of linearity in detection of the EUV light was found to be more than 10 4 with sensitivity of 10 4 photons/pixel, enough for the purpose of interferogram recording, possibly with one laser shot. 展开更多
关键词 soft x-ray interferometerS MULTILAYER mirrors FIGURE error imaging optics
在线阅读 下载PDF
Comparative analysis of phase extraction methods based on phase-stepping and shifting curve in grating interferometry 被引量:2
12
作者 刘小松 李恩荣 +8 位作者 朱佩平 刘宜晋 张凯 王志立 洪友丽 张慧滔 袁清习 黄万霞 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第4期173-179,共7页
Two phase extraction methods which are based separately on phase-stepping and shifting curve are mainly used in phase-sensitive imaging in gating interferometry to determine the x-ray phase shift induced by an object ... Two phase extraction methods which are based separately on phase-stepping and shifting curve are mainly used in phase-sensitive imaging in gating interferometry to determine the x-ray phase shift induced by an object in the beam. In this paper, the authors perform a full comparative analysis and present the main virtues and limitations of these two methods according to the theoretical analysis of the grating interferometry. 展开更多
关键词 x-ray phase sensitive imaging grating interferometer phase-stepping shifting curve
原文传递
Characteristic analysis of a novel F-P interferometer based on a pair of FBGs with built-in LPFGs 被引量:7
13
作者 王春宝 张伟刚 +2 位作者 阮隽 尚佳彬 颜爱东 《Optoelectronics Letters》 EI 2012年第2期84-88,共5页
The transmission characteristics of a Fabry-Perot (F-P) interferometer based on a fiber Bragg grating (FBG) pair with a built-in long-period fiber grating (LPFG) are theoretically analyzed, and the shift of tran... The transmission characteristics of a Fabry-Perot (F-P) interferometer based on a fiber Bragg grating (FBG) pair with a built-in long-period fiber grating (LPFG) are theoretically analyzed, and the shift of transmission interference fringe as a function of environmental refractive index is acquired. The influence of the lengths of F-P cavity, LPFG and FBG on the transmission characteristics of the proposed interferometer has been numerieaUy investigated, and the simulation results indicate that the sensitivity of refractive index reaches 2.27 × 10-6 for an optical spectrum analyzer (OSA) with a resolution of 1 pm. 展开更多
关键词 Fiber Bragg gratings interferometerS Spectrum analyzers
原文传递
Design of Time-Resolved Shifted Dual Transmission Grating Spectrometer for the X-Ray Spectrum Diagnostics 被引量:1
14
作者 王保清 易涛 +6 位作者 王传珂 朱效立 李廷帅 李晋 刘慎业 江少恩 丁永坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第7期781-785,共5页
A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which... A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which has two sub transmission gratings with different line densities, of 2000 lines/mm and 5000 lines/mm. The axes of the two sub transmission gratings in SDTG are horizontally and vertically shifted a certain distance to measure a broad range of 0.1-5 keV time-resolved X-ray spectra. The SDTG has been calibrated with a soft X-ray beam of the synchrotron radiation facility and its diffraction efficiency is also measured. The designed SDTGS can take full use of the space on a record panel and improve the precision for measuring spatial and temporal spectrum simultaneously. It will be a promising application for accurate diagnosis of the soft X-ray spectrum in inertial confinement fusion. 展开更多
关键词 shifted dual transmission grating spectrometer grating x-ray spectra diag-nosis of the soft x-ray spectrum
在线阅读 下载PDF
Theory and method of dual-energy x-ray grating phase-contrast imaging
15
作者 Feng Rong Yan Gao +2 位作者 Cui-Juan Guo Wei Xu Wei Xu 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第10期597-602,共6页
The principle of dual-energy x-ray grating phase-contrast imaging(DEPCI) is clarified by using the theory of x-ray interference and Fresnel diffraction. A new method of retrieving phase from the two interferograms is ... The principle of dual-energy x-ray grating phase-contrast imaging(DEPCI) is clarified by using the theory of x-ray interference and Fresnel diffraction. A new method of retrieving phase from the two interferograms is proposed for DEPCI,and its feasibility is verified via simulation. Finally, the proposed method applied to DEPCI experiment demonstrates the effectiveness of the method. This paper lays the theoretical foundation for performance optimization of DEPCI and the further integration of DEPCI and computed tomography. 展开更多
关键词 x-ray imaging DUAL-ENERGY ANALYZER grating PHASE RETRIEVAL
原文传递
Non-destructive study of fruits using grating-based X-ray imaging
16
作者 Sheng-Xiang Wang Ren-Fang Hu +5 位作者 Kun Gao Faiz Wali Gui-Bin Zan Da-Jiang Wang Zhi-Yun Pan Shi-Qiang Wei 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第2期57-60,共4页
Grating-based X-ray imaging can make use of conventional tube sources to provide absorption, refraction and scattering contrast images from a single set of projection images efficiently. In this paper, a fresh cherry ... Grating-based X-ray imaging can make use of conventional tube sources to provide absorption, refraction and scattering contrast images from a single set of projection images efficiently. In this paper, a fresh cherry tomato and a dried umeboshi are imaged by using X-ray Talbot–Lau interferometer. The seed distribution in the scattering image of the cherry tomato, and the wrinkles of epicarp in the refraction image of the umeboshi, are shown distinctly. The refraction and scattering images provide more information on subtle features than the absorption image. Also, the contrast-to-noise ratio values show distinguishing capacity of the three kinds of imaging techniques. The results confirm that grating-based X-ray imaging is of great potential in non-destructive fruit testing. 展开更多
关键词 NON-DESTRUCTIVE TESTING x-ray imaging Talbot–Lau interferometer FRUIT TESTING
在线阅读 下载PDF
Single-shot grating-based x-ray differential phase contrast imaging with a modified analyzer grating
17
作者 卫晨希 吴朝 +6 位作者 Faiz Wali 魏文彬 鲍园 骆荣辉 王磊 刘刚 田扬超 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期501-507,共7页
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa... X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging. 展开更多
关键词 x-ray phase contrast imaging single-shot decent resolution staggered grating computed tomography
原文传递
Development of an HCN dual laser for the interferometer on EAST
18
作者 李根 魏学朝 +7 位作者 刘海庆 申俊杰 揭银先 连辉 曾龙 邹志勇 张际波 王守信 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第8期37-42,共6页
A two-color continuous wave(CW) discharge-pumped far-infrared(FIR) hydrogen cyanide(HCN) laser was developed as the source of an interferometer for measuring the line-averaged electron density in the Experimenta... A two-color continuous wave(CW) discharge-pumped far-infrared(FIR) hydrogen cyanide(HCN) laser was developed as the source of an interferometer for measuring the line-averaged electron density in the Experimental Advanced Superconducting Tokamak(EAST). The output power of the dual laser system was about 120 m W from each laser on the 337 μm(0.89 THz)line. The polarization of each output beam was fixed using thin tungsten filaments and oscillated in the EH11 mode. Different megahertz intermediate frequencies(IF) and a slight frequency offset(~1 MHz) were generated in this system to replace the traditional rotating grating with~10 k Hz IF, and this can improve the time resolution of the interferometer significantly. The experimental result showed that different IF signals were obtained by successfully adjusting the cavity length. In particular, the beat frequency was captured at ~1.3 MHz by a Schottky mixer when the length of the resonant cavities was changed by 5 μm by an automatic adjustment system. In order to study the character of IF, a long time record of the IF signal was carried out,and the IF signal could be stabilized for a few minutes in the range of 2 MHz to 3 MHz. A realtime IF stability control system was initially designed for long pulse discharge experiments on the EAST. The ~MHz frequency response and good phase sensitivity of the dual laser HCN interferometer will allow the system to track fast density profiles and resolve fast MHD events,such as tearing/neoclassical tearing, disruptions, etc. 展开更多
关键词 EAST interferometer Schottky pumped mixer captured tungsten grating resonant rotating
在线阅读 下载PDF
ASE Noise Characterization of an All-Fiber Sagnac Interferometer via LAN for Remote Sensing
19
作者 Abraham Sierra-Calderon Jose Carlos Rodriguez-Novelo +3 位作者 Manuel May-Alarcon Jaime Rafael Ek-Ek Jose Alfredo Alvarez-Chavez Herman Leonard Offerhaus 《Open Journal of Applied Sciences》 2018年第12期554-575,共22页
The spectral noise characteristic and relative intensity noise of an all-fibre Sagnac interferometer consisting of pump source, a WDM, a piece of Er-doped fibre, a fibre Bragg grating (FBG), an optical circulator and ... The spectral noise characteristic and relative intensity noise of an all-fibre Sagnac interferometer consisting of pump source, a WDM, a piece of Er-doped fibre, a fibre Bragg grating (FBG), an optical circulator and a 50/50 coupler, were studied over a 75C-degree range. At the probing end, a high-birefringence piece of fibre and a Peltier were employed for temperature variation. Spectral and temperature response of the noise reduction due to temperature variation was performed remotely using an Arduino micro-controller and a DS18B20 digital sensor and fed into a local area network. Optical and thermal charac-terization of the system has also been undertaken. 展开更多
关键词 Amplified SPONTANEOUS Emission Noise SAGNAC interferometer Optical FIBRE Sensor ERBIUM-DOPED FIBRE Amplifier FIBRE BRAGG grating
在线阅读 下载PDF
A tension insensitive PbS fiber temperature sensor based on Sagnac interferometer
20
作者 付兴虎 张江鹏 +4 位作者 杨凯丽 董艳华 文建湘 付广伟 毕卫红 《Optoelectronics Letters》 EI 2017年第2期135-137,共3页
In this paper, a tension insensitive Pb S fiber temperature sensor based on Sagnac interferometer is proposed and demonstrated. The sensing mechanism of tension and temperature is analyzed. The relationships between t... In this paper, a tension insensitive Pb S fiber temperature sensor based on Sagnac interferometer is proposed and demonstrated. The sensing mechanism of tension and temperature is analyzed. The relationships between the interference spectrum, temperature and tension are analyzed, respectively. The experimental temperature range is 36—70 °C. The experimental results show that the interference spectrum is red shifted, and its sensitivity is 53.89 pm/°C. In tension experiment, the tension range is 0—1 400 με. The experimental results show that there is no wavelength shift in the interference spectrum. The sensor is immune to tension cross-sensitivity compared with other sensors. It can be used for temperature testing in aerospace, chemistry and pharmacy. 展开更多
关键词 interferometer insensitive pharmacy aerospace shifted temper schematic Bragg grating coupler
原文传递
上一页 1 2 16 下一页 到第
使用帮助 返回顶部