期刊文献+
共找到176篇文章
< 1 2 9 >
每页显示 20 50 100
A Novel Angiotensin I Converting Enzyme Inhibitory Peptide from the Milk Casein:Virtual Screening and Docking Studies 被引量:6
1
作者 WANG Zhan-li ZHANG Sai-sai +2 位作者 WANG Wei FENG Feng-qin SHAN Wei-guang 《Agricultural Sciences in China》 CAS CSCD 2011年第3期463-467,共5页
Angiotensin I converting enzyme (ACE) plays an important physiological role in the regulation of hypertension. In this study, we applied virtual screening to discover a novel angiotensin I converting enzyme inhibito... Angiotensin I converting enzyme (ACE) plays an important physiological role in the regulation of hypertension. In this study, we applied virtual screening to discover a novel angiotensin I converting enzyme inhibitory peptides from milk casein. One potential hit was identified based on docking scores, subsequently confirmed by activity studies in vitro (IC50=20.85 μmol L-1). The proposed peptide in this study contains a unique sequence, Lys-Val-Leu-Ile-Leu-Ala. Moreover, we performed the docking studies to understand the binding mode between the enzyme and peptide hit. 展开更多
关键词 novel angiotensin I converting enzyme inhibitory peptide virtual screening DOCKING
在线阅读 下载PDF
Ultra-stable CsPbBr3 Perovskite Nanosheets for X-Ray Imaging Screen 被引量:6
2
作者 Liangling Wang Kaifang Fu +3 位作者 Ruijia Sun Huqiang Lian Xun Hu Yuhai Zhang 《Nano-Micro Letters》 SCIE EI CAS CSCD 2019年第3期263-270,共8页
Wet chemistry methods,including hot-injection and precipitation methods,have emerged as major synthetic routes for high-quality perovskite nanocrystals in backlit display and scintillation applications.However,low che... Wet chemistry methods,including hot-injection and precipitation methods,have emerged as major synthetic routes for high-quality perovskite nanocrystals in backlit display and scintillation applications.However,low chemical yield hinders their upscale production for practical use.Meanwhile,the labile nature of halide-based perovskite poses a major challenge for long-term storage of perovskite nanocrystals.Herein,we report a green synthesis at room temperature for gram-scale production of CsPbBr3 nanosheets with minimum use of solvent,saving over 95% of the solvent for the unity mass nanocrystal production.The perovskite colloid exhibits record stability upon long-term storage for up to 8 months,preserving a photoluminescence quantum yield of 63% in solid state.Importantly,the colloidal nanosheets show self-assembly behavior upon slow solidification,generating a crack-free thin film in a large area.The uniform film was then demonstrated as an efficient scintillation screen for X-ray imaging.Our findings bring a scalable tool for synthesis of high-quality perovskite nanocrystals,which may inspire the industrial optoelectronic application of large-area perovskite film. 展开更多
关键词 CsPbBr3 PEROVSKITE NANOSHEETS SELF-ASSEMBLY x-ray imaging screen
在线阅读 下载PDF
A new method of detecting interferogram in differential phase-contrast imaging system based on special structured x-ray scintillator screen 被引量:6
3
作者 刘鑫 郭金川 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期193-197,共5页
An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and ... An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented. 展开更多
关键词 differential phase contrast x-ray scintillator screen phase retrieval
原文传递
Screening and early diagnosis of osteoporosis through X-ray and ultrasound based techniques 被引量:5
4
作者 Paola Pisani Maria Daniela Renna +5 位作者 Francesco Conversano Ernesto Casciaro Maurizio Muratore Eugenio Quarta Marco Di Paola Sergio Casciaro 《World Journal of Radiology》 CAS 2013年第11期398-410,共13页
Effective prevention and management of osteoporosis would require suitable methods for population screenings and early diagnosis. Current clinicallyavailable diagnostic methods are mainly based on the use of either X-... Effective prevention and management of osteoporosis would require suitable methods for population screenings and early diagnosis. Current clinicallyavailable diagnostic methods are mainly based on the use of either X-rays or ultrasound(US). All X-ray based methods provide a measure of bone mineral density(BMD), but it has been demonstrated that other structural aspects of the bone are important in determining fracture risk, such as mechanical features and elastic properties, which cannot be assessed using densitometric techniques. Among the most commonly used techniques, dual X-ray absorptiometry(DXA) is considered the current 'gold standard' for osteoporosis diagnosis and fracture risk prediction. Unfortunately, as other X-ray based techniques, DXA has specific limitations(e.g., use of ionizing radiation, large size of the equipment, high costs, limited availability) that hinder its application for population screenings and primary care diagnosis. This has resulted in an increasing interest in developing reliable pre-screening tools for osteoporosis such as quantitative ultrasound(QUS) scanners, which do not involve ionizing radiation exposure and represent a cheaper solution exploiting portable and widely available devices. Furthermore, the usefulness of QUS techniques in fracture risk prediction has been proven and, with the last developments, they are also becoming a more and more reliable approach for assessing bone quality. However, the US assessment of osteoporosis is currently used only as a pre-screening tool, requiring a subsequent diagnosis confirmation by means of a DXA evaluation. Here we illustrate the state of art in the early diagnosis of this 'silent disease' and show up recent advances for its prevention and improved management through early diagnosis. 展开更多
关键词 Diagnosis of OSTEOPOROSIS screenING TECHNIQUES x-ray BASED methods Quantitative ULTRASOUND Peripheral sites Bone mineral density
暂未订购
Enhancing the performance of photovoltaic cells by using down-converting KCaGd(PO_4)_2:Eu^(3+) phosphors 被引量:6
5
作者 陈彦吉 黄琬妤 陈登铭 《Journal of Rare Earths》 SCIE EI CAS CSCD 2011年第9期907-910,共4页
The goal of this work is aimed to improve the power conversion efficiency of single crystalline silicon-based photovoltaic (PV) cells by using the solar spectral conversion principle, which employed a down-convertin... The goal of this work is aimed to improve the power conversion efficiency of single crystalline silicon-based photovoltaic (PV) cells by using the solar spectral conversion principle, which employed a down-converting phosphor to convert a high-energy ultraviolet photon to the less energetic red-emitting photons to improve the spectral response of Si solar cells. In this study, the surface of silicon solar cells was coated with a red-emitting KCaGd(PO4)2:Eu3+ phosphor by using the screen-printing technique. In addition to the investigation on the microstructure using scanning electron microscopy (SEM), we measured the short circuit current (Isc), open circuit voltage (Voc), and power conversion efficiency (η) of spectral-conversion cells and compared with those of bare solar cells as a reference. Preliminary experimental results revealed that in an optimized PV cell, an enhancement of (0.64+0.01)% (from 16.03% to 16.67%) in Δη of a Si-based PV cell was achieved. 展开更多
关键词 solar cells down-converting phosphor KCaGd(PO4)2:Eu3+ screen-printing rare earths
原文传递
Population-based X-ray gastric cancer screening in Hiroshima prefecture, Japan
6
作者 Nhu Thi Hanh Vu Yuji Urabe +2 位作者 Duc Trong Quach Shiro Oka Toru Hiyama 《World Journal of Clinical Oncology》 2024年第2期271-281,共11页
BACKGROUND X-ray gastric cancer(GC)screening has been shown to decrease mortality.Population-based X-ray GC screening has been performed in Hiroshima Prefe-cture,Japan,since 1983 but time trends and the efficacy of th... BACKGROUND X-ray gastric cancer(GC)screening has been shown to decrease mortality.Population-based X-ray GC screening has been performed in Hiroshima Prefe-cture,Japan,since 1983 but time trends and the efficacy of the method over 39 years have not been assessed.METHODS This was a population-based retrospective study.The data were derived from aggregated data of the Hiroshima Regional Health Medical Promotion Organization,including the number and rate of participants and those requiring esophagogastroduodenoscopies(EGDs),the number and rate of participants diagnosed as having GC,and the positive predictive value of the abnormal findings detected by X-ray and confirmed by EGDs.The number and rate of esophageal cancers were also collected.Further,the cost of detecting one GC was evaluated.RESULTS The number of participants has decreased during the last four decades,from 39925 in 1983 to 12923 in 2021.The rate of those requiring EGDs decreased significantly in recent years(P<0.001).The number of participants diagnosed as having GC has also declined,from 76 to 10 cases.However,the rate of cases diagnosed as GC among the participants remained around 0.1%.The positive predictive value increased significantly in recent years except during 1983-1991.The number and rate of accidentally detected esophageal cancers have risen recently,from 0%in 2008 to 0.02%in 2021,one-fifth of the diagnosis rate of GC.One GC diagnosis costs approximately 4200000 Japanese Yen(30000 United States Dollars)for the X-ray screenings and EGDs.CONCLUSION X-ray GC screening in Hiroshima has been efficient,but one challenge is the cost.Esophageal cancers may also need to be considered because they have gradually increased in recent years. 展开更多
关键词 POPULATION Retrospective studies x-ray Gastric cancer screenING
暂未订购
Current issues and future perspectives of gastric cancer screening 被引量:49
7
作者 Chisato Hamashima 《World Journal of Gastroenterology》 SCIE CAS 2014年第38期13767-13774,共8页
Gastric cancer remains the second leading cause of cancer death worldwide. About half of the incidence of gastric cancer is observed in East Asian countries, which show a higher mortality than other countries. The eff... Gastric cancer remains the second leading cause of cancer death worldwide. About half of the incidence of gastric cancer is observed in East Asian countries, which show a higher mortality than other countries. The effectiveness of 3 new gastric cancer screening techniques, namely, upper gastrointestinal endoscopy, serological testing, and &#x0201c;screen and treat&#x0201d; method were extensively reviewed. Moreover, the phases of development for cancer screening were analyzed on the basis of the biomarker development road map. Several observational studies have reported the effectiveness of endoscopic screening in reducing mortality from gastric cancer. On the other hand, serologic testing has mainly been used for targeting the high-risk group for gastric cancer. To date, the effectiveness of new techniques for gastric cancer screening has remained limited. However, endoscopic screening is presently in the last trial phase of development before their introduction to population-based screening. To effectively introduce new techniques for gastric cancer screening in a community, incidence and mortality reduction from gastric cancer must be initially and thoroughly evaluated by conducting reliable studies. In addition to effectiveness evaluation, the balance of benefits and harms must be carefully assessed before introducing these new techniques for population-based screening. 展开更多
关键词 Gastric cancer screening MORTALITY Upper gastrointestinal endoscopy Upper gastrointestinal x-ray Serum pepsinogen test Helicobacter pylori antibody
暂未订购
Comparing upper gastrointestinal X-ray and endoscopy for gastric cancer diagnosis in Korea 被引量:7
8
作者 Hoo-Yeon Lee Eun-Cheol Park +2 位作者 Jae Kwan Jun Kui Son Choi Myung-Il Hahm 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第2期245-250,共6页
AIM:To compare the cost and accuracy of upper gastrointestinal(GI)X-ray and upper endoscopy for diagnosis of gastric cancer using data from the 2002-2004 Korean National Cancer Screening Program(NCSP). METHODS:The stu... AIM:To compare the cost and accuracy of upper gastrointestinal(GI)X-ray and upper endoscopy for diagnosis of gastric cancer using data from the 2002-2004 Korean National Cancer Screening Program(NCSP). METHODS:The study population included 1 503 646 participants in the 2002-2004 stomach cancer screening program who underwent upper GI X-ray or endoscopy.The accuracy of screening was defined as the probability of detecting gastric cancer.We calculated the probability by merging data from the NCSP and the Korea Central Cancer Registry.We estimated the direct costs of the medical examination and the tests for up- per GI X-ray,upper endoscopy,and biopsy. RESULTS:The probability of detecting gastric cancervia upper endoscopy was 2.9-fold higher than via upper GI X-ray.The unit costs of screening using upper GI X-ray and upper endoscopy were$32.67 and$34.89, respectively.In 2008,the estimated cost of identifying one case of gastric cancer was$53094.64 using upper GI X-ray and$16 900.43 using upper endoscopy.The cost to detect one case of gastric cancer was the same for upper GI X-ray and upper endoscopy at a cost ratio of 1:3.7. CONCLUSION:Upper endoscopy is slightly more costly to perform,but the cost to detect one case of gastric cancer is lower. 展开更多
关键词 Gastric cancer Mass screening ENDOSCOPY Early diagnosis x-ray diagnosis
暂未订购
BL19U2:Small-angle X-ray scattering beamline for biological macromolecules in solution at SSRF 被引量:6
9
作者 Yi-Wen Li Guang-Feng Liu +4 位作者 Hong-Jin Wu Ping Zhou Chun-Xia Hong Na Li Feng-Gang Bian 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2020年第12期32-40,共9页
The BL19U2 at the Shanghai Synchrotron Radiation Facility is a small-angle X-ray scattering beamline dedicated to structural studies pertaining to biological macromolecules in solution.The beamline has been officially... The BL19U2 at the Shanghai Synchrotron Radiation Facility is a small-angle X-ray scattering beamline dedicated to structural studies pertaining to biological macromolecules in solution.The beamline has been officially opened to users in March 2015,and since then,a series of technological innovations has been developed to optimize beamline performance,thereby significantly improving the data collection efficiency and broadening the application scope of biological small-angle X-ray scattering.BL19U2 is ideal for the high-throughput screening of weakly scattered proteins,protein assemblies,nucleic acids,inorganic nanomaterials,and organic drug molecules.This paper describes the design and overview of the BL19U2 beamline.Versatile sample environments at the experimental station and some recent scientific highlights are presented. 展开更多
关键词 Shanghai synchrotron radiation facility Biological small-angle x-ray scattering High-throughput screening Biological macromolecules
在线阅读 下载PDF
A Study on Cascade R-CNN-Based Dangerous Goods Detection Using X-Ray Image 被引量:1
10
作者 Sang-Hyun Lee 《Computers, Materials & Continua》 SCIE EI 2022年第11期4245-4260,共16页
X-ray inspection equipment is divided into small baggage inspection equipment and large cargo inspection equipment.In the case of inspection using X-ray scanning equipment,it is possible to identify the contents of go... X-ray inspection equipment is divided into small baggage inspection equipment and large cargo inspection equipment.In the case of inspection using X-ray scanning equipment,it is possible to identify the contents of goods,unauthorized transport,or hidden goods in real-time by-passing cargo through X-rays without opening it.In this paper,we propose a system for detecting dangerous objects in X-ray images using the Cascade Region-based Convolutional Neural Network(Cascade R-CNN)model,and the data used for learning consists of dangerous goods,storage media,firearms,and knives.In addition,to minimize the overfitting problem caused by the lack of data to be used for artificial intelligence(AI)training,data samples are increased by using the CP(copy-paste)algorithm on the existing data.It also solves the data labeling problem by mixing supervised and semi-supervised learning.The four comparative models to be used in this study are Faster Regionbased Convolutional Neural Networks Residual2 Network-101(Faster R-CNN_Res2Net-101)supervised learning,Cascade R-CNN_Res2Net-101_supervised learning,Cascade Region-based Convolutional Neural Networks Composite Backbone Network V2(CBNetV2)Network-101(Cascade R-CNN_CBNetV2Net-101)_supervised learning,and Cascade RCNN_CBNetV2-101_semi-supervised learning which are then compared and evaluated.As a result of comparing the performance of the four models in this paper,in case of Cascade R-CNN_CBNetV2-101_semi-supervised learning,Average Precision(AP)(Intersection over Union(IoU)=0.5):0.7%,AP(IoU=0.75):1.0%than supervised learning,Recall:0.8%higher. 展开更多
关键词 Cascade R-CNN model faster R-CNN model x-ray screening equipment Res2Net supervised learning semi-supervised learning
在线阅读 下载PDF
Differential screening captopril responsive genes in the heart of spontaneously hypertensive rats
11
作者 祝之明 刘玉清 +3 位作者 许有元 孟宪敏 赵斌 祝善俊 《Journal of Medical Colleges of PLA(China)》 CAS 2000年第1期29-31,共3页
Objective: To determine whether administiation of captopril, an ACE inhibitor, can induce unique gene expression in hearts from spontaneously hypertensive rats (SHR). Methods: Differential screening was used to isolat... Objective: To determine whether administiation of captopril, an ACE inhibitor, can induce unique gene expression in hearts from spontaneously hypertensive rats (SHR). Methods: Differential screening was used to isolate captopril response genes through a human fetal cDNA library, and reverse northern blot technique was applied to analyze gene expression. Results: Administration of captopril in SHR significantly lowered blood pressure, heart rate (HR), and the ratio of heart to body weight was compared with untreated SHR. Three captopril responsive cDNA sequences (expreed sequence tags, ESTs) were identified. One ESTs were highly homologous to human mitochondria gene and other 2 were novel and unknown genes. Conclusion: The benefit of captopril may be mediated, at least in part, by having an effect on the expression of a specific gene involved in cardiac remodeling and function in essential hypertension. 展开更多
关键词 CAPTOPRIL HEART differential screening hypertension ANGIOTENSIN converting ENZYME inhibitor
暂未订购
Asymptomatic Screening of Clients on Opioid Substitution Therapy for Tuberculosis: An Experience from India
12
作者 Banuru Muralidhara Prasad Mandeep Singh +4 位作者 Mukesh Gupta Thekkur K. Pruthu Rajeev Kumar Parmesh C. Bhatnagar Sarabjit Singh Chadha 《Journal of Tuberculosis Research》 2019年第3期131-134,共4页
Clients on Opioid Substitution Therapy (OST) may be at risk of TB. We screened for tuberculosis in asymptomatic OST clients using Chest-X-ray (CXR) and sputum from those with CXR suggestive of TB were tested using Xpe... Clients on Opioid Substitution Therapy (OST) may be at risk of TB. We screened for tuberculosis in asymptomatic OST clients using Chest-X-ray (CXR) and sputum from those with CXR suggestive of TB were tested using Xpert MTB/Rif. Among 472 who underwent CXR, 0.1% had CXR suggestive of TB. The number needed to screen was 118 clients for one CXR suggestive of TB. All four clients with CXR suggestive of TB underwent MTB/Rif assay and one was diagnosed with TB. The TB patient was asymptomatic and could have been missed through the passive approach. We recommend further studies to explore ACF among OST clients. 展开更多
关键词 OST TUBERCULOSIS Active Case Finding screenING CHEST x-ray
暂未订购
Using Prostatic Fluid Levels of Some Trace Elements and Their Combinations in Non-Invasive and Highly Accurate Screening for Prostate Cancer
13
作者 Vladimir Zaichick 《Journal of Cancer Therapy》 2020年第1期1-17,共17页
Objective: Prostate specific antigen (PSA) does not provide the high reliability and precision that is required for an accurate screening for prostate cancer?(PCa). The aim of our study was to search for a simple, rap... Objective: Prostate specific antigen (PSA) does not provide the high reliability and precision that is required for an accurate screening for prostate cancer?(PCa). The aim of our study was to search for a simple, rapid, direct, preferably non-invasive, and highly accurate biomarker and procedure for the screening for PCa. Method: The levels of trace elements (TE) Br, Fe, Rb, Sr,?and Zn were prospectively evaluated in expressed prostatic fluid (EPF). Also?Zn/Br, Zn/Fe, Zn/Rb, Zn/Sr concentration ratios as well as ZnRb and (ZnRb)/Fe concentration combinations were calculated for EPF samples, obtained from 38 apparently healthy males and from 33, 51, and 24 patients with chronic prostatitis, benign prostatic hyperplasia, and PCa, respectively. Measurements were performed using an energy dispersive X-ray fluorescent (EDXRF) microanalysis. Results: It was found that in the EPF of cancerous prostates the levels of Rb, Zn, Zn/Br, Zn/Fe, Zn/Sr, ZnRb, and (ZnRb)/Fe were significantly lower in comparison with those in the EPF of normal, inflamed, and hyperplastic prostates. For example, in comparison hyperplastic?with cancerous prostates p values obtained using Student’s t-test and?Wilcoxon-Mann-Whitney U-test were Conclusions: The levels of TE and their combinations in EPF, obtained by EDXRF, is a fast, reliable, andnon-invasive diagnostic tool that can be successfully used by local, non- urologist physicians at the point-of-care to provide a highly effective PCa screening and as an additional confirmatory test before a prostate gland biopsy. 展开更多
关键词 UROLOGY screening Prostate Cancer EXPRESSED PROSTATIC Fluid Trace Element Content Energy-Dispersive x-ray Fluorescent Analysis
暂未订购
Most Intense X-Ray Lines of the Helium Isoelectronic Sequence for Plasmas Diagnostic
14
作者 Ibrahima Sakho 《Journal of Modern Physics》 2020年第4期487-501,共15页
We report accurate wavelengths for the three most intense lines (resonance line: 1s2 1S0 - 1s2p 1P1, intercombination line: 1s2 1S0 - 1s2p 3P1 and forbidden line: 1s2 1S0 - 1s2s 3S1) along with wavelengths for the 1s2... We report accurate wavelengths for the three most intense lines (resonance line: 1s2 1S0 - 1s2p 1P1, intercombination line: 1s2 1S0 - 1s2p 3P1 and forbidden line: 1s2 1S0 - 1s2s 3S1) along with wavelengths for the 1s2 1S0 - 1snp1P1 and 1S0 - 1snp3P2 (2 ≤ n ≤ 25) transitions in He-like systems (Z = 2 – 13). The first spectral lines that belong to the above transitions are established in the framework of the Screening Constant per Unit Nuclear Charge method. The results obtained agree excellently with various experimental and theoretical literature data. The uncertainties in wavelengths between the present calculations and the available literature data are less than 0.004&Aring;. A host of new data listed in this paper may be of interest in astrophysical and laboratory plasmas diagnostic. 展开更多
关键词 HE-LIKE Systems SEMI-EMPIRICAL screening Constant Per Unit Nuclear Charge Excited States x-ray Spectra
在线阅读 下载PDF
黄骅港大宗散货码头煤炭堆场工程设计要点 被引量:1
15
作者 刘元平 刘春峰 +1 位作者 陈伟良 陈凯凯 《水运工程》 2025年第5期71-79,共9页
针对如何充分利用不规则地形满足多功能需求和优化工程投资等问题,进行黄骅港大宗散货码头煤炭堆场设计研究。通过对工程整体的功能分析,分别采用堆场同侧进出实现不规则地形的充分利用;采用交叉双尾车实现与斗轮堆取料机相连带式输送... 针对如何充分利用不规则地形满足多功能需求和优化工程投资等问题,进行黄骅港大宗散货码头煤炭堆场设计研究。通过对工程整体的功能分析,分别采用堆场同侧进出实现不规则地形的充分利用;采用交叉双尾车实现与斗轮堆取料机相连带式输送机的双向运行;采用智能控制变频驱动技术实现带式输送机不同输送能力的需求;采用在堆料机上设置滚轴筛实现煤炭筛分功能等,满足了各项功能的需求,使该工程达到预期的效果。 展开更多
关键词 煤炭堆场 堆场同侧进出 交叉双尾车 变频器 筛分堆料机
在线阅读 下载PDF
高效轧制棒线材一键切换控制研究与应用
16
作者 侯栋 郭新文 +1 位作者 陈虎明 丁建军 《冶金设备管理与维修》 2025年第3期63-64,共2页
针对南北线复合生产线切换效率低的问题,提出一键切换控制系统的技术改造方案。通过构建主电源切换柜、优化变频器参数切换逻辑、实现PLC系统互联互通及WINCC(西门子监控系统)画面智能切换,将切换时间由120min缩短至15min。系统采用2套... 针对南北线复合生产线切换效率低的问题,提出一键切换控制系统的技术改造方案。通过构建主电源切换柜、优化变频器参数切换逻辑、实现PLC系统互联互通及WINCC(西门子监控系统)画面智能切换,将切换时间由120min缩短至15min。系统采用2套变频器控制3台主电机的灵活配置,在保障安全互锁的前提下显著提升产线作业率,为连铸坯直接轧制工艺提供技术支撑。 展开更多
关键词 棒线材轧制 一键切换 变频器参数 PLC通讯 WINCC画面
在线阅读 下载PDF
基于PLC和触摸屏的变频器远方/就地切换多段速控制 被引量:1
17
作者 邹玉超 《自动化应用》 2025年第15期55-57,62,共4页
介绍了一种基于西门子S7-1200 PLC与TP1500系列触摸屏的G120变频器远方/就地多段速控制方案。该方案采用Profinet通信,实现PLC对变频器的远方多段速控制,同时通过数字量输入接口实现变频器的就地多段速控制。详细阐述了控制要求、总体... 介绍了一种基于西门子S7-1200 PLC与TP1500系列触摸屏的G120变频器远方/就地多段速控制方案。该方案采用Profinet通信,实现PLC对变频器的远方多段速控制,同时通过数字量输入接口实现变频器的就地多段速控制。详细阐述了控制要求、总体控制方案设计、变频器参数设定、就地控制与远方控制的实现方式,以及HMI监控画面组态与主要控制程序设计等关键环节。 展开更多
关键词 可编程逻辑控制器 变频器 触摸屏 多段速
在线阅读 下载PDF
基于S7-1200PLC实现扶梯系统设计
18
作者 车前 《开封大学学报》 2025年第3期74-77,共4页
介绍了S7-1200PLC、MM420变频器和西门子精智T700触摸屏在交流电机高低速控制中的应用。自动扶梯的功率相对较高,因此在无人乘梯时低速运行,有人乘梯时则以额定功率高速运行。通过触摸屏,可对自动扶梯运行频率及扶梯上的人数进行监控。... 介绍了S7-1200PLC、MM420变频器和西门子精智T700触摸屏在交流电机高低速控制中的应用。自动扶梯的功率相对较高,因此在无人乘梯时低速运行,有人乘梯时则以额定功率高速运行。通过触摸屏,可对自动扶梯运行频率及扶梯上的人数进行监控。应用结果证明,该方案调速灵活、方便、可靠。 展开更多
关键词 自动扶梯 PLC 变频器 触摸屏
在线阅读 下载PDF
基于PLC变频器和触摸屏控制的全自动洗衣机控制系统设计
19
作者 苏林 《模具制造》 2025年第12期47-49,共3页
随着工业自动化技术和智能家居的快速发展,全自动洗衣机作为现代家庭、酒店、医院等场所的必备的清洁电器,其控制系统的性能、可靠性和用户体验直接决定了产品的市场竞争力。设计了一种基于PLC、变频器和触摸屏的全自动洗衣机智能控制系... 随着工业自动化技术和智能家居的快速发展,全自动洗衣机作为现代家庭、酒店、医院等场所的必备的清洁电器,其控制系统的性能、可靠性和用户体验直接决定了产品的市场竞争力。设计了一种基于PLC、变频器和触摸屏的全自动洗衣机智能控制系统,通过工业自动化技术实现了洗涤过程的精准化、高效化和用户友好化。该系统以三菱PLC为核心控制器,采用三菱变频器动态调节电机转速,实现多段速柔性洗涤,结合昆仑通态触摸屏,实现洗涤过程的自动化控制及实时监控。 展开更多
关键词 PLC 变频器 触摸屏 全自动洗衣机
在线阅读 下载PDF
九开关变换器无电流传感器改进模型预测控制
20
作者 郭伽 贾天亮 甄然 《计算机仿真》 2025年第9期382-389,共8页
九开关变换器采用有限集模型预测控制驱动双永磁同步电机时,其开关状态相对普通逆变器较多,计算量较大,不利于在线计算。由于需要电流传感器采集定子电流,增加了系统的成本。提出了一种无电流传感器的改进有限集模型预测双电机控制方法... 九开关变换器采用有限集模型预测控制驱动双永磁同步电机时,其开关状态相对普通逆变器较多,计算量较大,不利于在线计算。由于需要电流传感器采集定子电流,增加了系统的成本。提出了一种无电流传感器的改进有限集模型预测双电机控制方法。首先通过电压矢量筛选,减少了每周期需要遍历的开关状态,降低了计算量。其次,基于开关函数和电机的数学模型构建了电流观测器,通过采集直流侧电压和转速信息对电流进行观测,用一个电压传感器代替四个电流传感器,降低了成本,提高了电路的集成度。另外改进了目标函数,引入了空间矢量距离函数,降低了开关损耗。通过仿真的方法,验证了上述控制方法的正确性和有效性。 展开更多
关键词 九开关变换器 模型预测控制 电压矢量筛选 电流观测
在线阅读 下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部