This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation ...This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation transfer function(MTF),and detective quantum efficiency(DQE)of the DL-FPD are evaluated numerically using a linear cascade model.In addition,both the single-crystal(SC)and polycrystalline(PC)structures of MAPbI_(3)are investigated,along with various other key parameters such as the material thickness,electric field strength,X-ray beam spectrum,and electronic readout noise.The results demonstrate that SC perovskite consistently exhibits better performance than PC perovskite owing to fewer material defects.Increasing the layer thickness may decrease the MTF,but can also enhance the sensitivity and DQE.Moreover,appropriately increasing the external electric field within the material can improve the sensitivity,MTF,and DQE.Finally,reducing the electronic readout noise can significantly enhance the DQE for low-dose imaging.This study demonstrates the potential of high-quality dual-energy X-ray imaging using direct-conversion perovskite DL-FPDs.展开更多
With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this ...With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this study,the effects of X-ray beam size and photon energy on the accuracy of critical dimension measurements were investigated.Critical dimensions measured using beams with different spot sizes showed different deviations from the expected values.Beam sizes that were either too large or too small did not improve confidence intervals.As the incident energy increased,the X-ray transmission rate increased,while the scattering cross section decreased,resulting in a gradual decrease in the signal-to-noise ratio of the diffraction peaks,which reduced the accuracy of the CD-SAXS measurements.An optimal accuracy was obtained at 12 keV with a smaller beam size.Using an effective trapezoid model,the results yielded an average pitch of 100.4±0.2 nm,width of 49.8±0.2 nm,height of 130.0±0.2 nm,and a sidewall angle below 1.1°±0.1°.These results provide crucial guidance for the future development of CD-SAXS laboratories and the construction of X-ray machines as well as robust support for research in related fields.展开更多
The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality....The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.Synthetic aperture x-ray ghost imaging(SAXGI)is invented to achieve megapixel XGI with limited measurements,which is expected to implement XGI simultaneously with large field of view and low radiation exposure.In this paper,we experimentally investigate the effect of measurements reduction on the spatial resolution and image quality of SAXGI with standard sample and biomedical specimen.The results with a resolution chart demonstrated that at 360 measurements,SAXGI successfully retrieved the sample image of 1960×1960 pixels with spatial resolution of 4μm.With measurement reduction,the spatial resolution deteriorates but the sparser structures are still discernable.Even with measurements reduced to 10,a spatial resolution of 10μm can still be achieved by SAXGI.A biomedical sample of a fish specimen is employed to evaluate the method and the fish image of 2000×1000 pixels with an SSIM of 0.962 is reconstructed by SAXGI with 770measurements,corresponding to an accumulative exposure reduction of more than 2 times.With the measurements reduced to 10 which corresponds to 1/160 of the accumulative radiation exposure for conventional radiology,bulky structure like the fish skeleton can still be definitely discerned and the SSIM for the reconstructed image still retained 0.9179.Results of this paper demonstrate that measurements reduction is practicable for the radiation exposure reduction of the sample,which implicates that SAXGI with limited measurements is an efficient solution for low dose radiology.展开更多
A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-d...A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-dimensional cusp boundary from a two-dimensional X-ray image because the detected X-ray signals will be integrated along the line of sight.In this work,a global magnetohydrodynamic code was used to simulate the X-ray images and photon count images,assuming an interplanetary magnetic field with a pure Bz component.The assumption of an elliptic cusp boundary at a given altitude was used to trace the equatorward and poleward boundaries of the cusp from a simulated X-ray image.The average discrepancy was less than 0.1 RE.To reduce the influence of instrument effects and cosmic X-ray backgrounds,image denoising was considered before applying the method above to SXI photon count images.The cusp boundaries were reasonably reconstructed from the noisy X-ray image.展开更多
This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both commo...This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification.展开更多
This paper presents a programmable frequency scan algorithm based on harmonic balance.The core idea involves treating systems under perturbation as nonlinear time-periodic(NTP)systems.Steady-state harmonics are first ...This paper presents a programmable frequency scan algorithm based on harmonic balance.The core idea involves treating systems under perturbation as nonlinear time-periodic(NTP)systems.Steady-state harmonics are first solved via Newton-Raphson iteration through a set of nonlinear equations,and then input-output variables are selected to estimate the linear transfer function of the original NTP system without perturbations.The applications and insights of the proposed algorithm are discussed,particularly in guiding existing frequency scan algorithms,which are restricted by time-domain signal generation or measurement.This improvement is achieved through linear stability analysis of NTP systems with perturbations.展开更多
Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfur...Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfurization were analyzed.When the total aluminum content in the steel increased from 6 to 1100 ppm,the CaS content in CaO–Al_(2)O_(3) particles increased from 2.1wt%to 84.84wt%after the reaction for 90 s.Furthermore,when the silicon content in the steel increased from 0.01wt%to 2.20wt%,the CaS content in CaO–Al_(2)O_(3) particles increased from 1.53wt%to 79.01wt%after the reaction for 90 s.This indicates that the increase in the aluminum and silicon contents of the steel promoted the desulfurization of CaO–Al_(2)O_(3) particles.A kinetic model was established to predict the CaO–Al_(2)O_(3) particles composition,and the diffusion coefficient of sulfur in CaO–Al_(2)O_(3) particles was 9.375×10^(−10)m^(2)·s^(−1) at 1600℃,which provided a new method for the calculation of diffusion coefficient.展开更多
Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics...Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics,and free electron radiation devices.Particularly,they are promising platforms for studying thermionic emission.It is illustrated that using vdW heterostructure-based thermionic emission can enhance heat transfer in vacuum devices.As a proof of concept,the approach is demonstrated to offer a promising solution for the long-standing overheating issue in X-ray tubes.Specifically,it is shown that the saturated target temperature of a 2000 W X-ray tube can be reduced from around 1200℃ to 490℃.Additionally,it is also demonstrated that by reducing the height of the Schottky barrier formed in the vdW heterostructures,the thermionic cooling performance can be enhanced.The findings pave the way for the development of high-power X-ray tubes.展开更多
Objective:To explore the application effect of digital intraoral scanning impression technique in oral implant restoration for periodontitis patients and analyze its impact on patients’Visual Analogue Scale(VAS)score...Objective:To explore the application effect of digital intraoral scanning impression technique in oral implant restoration for periodontitis patients and analyze its impact on patients’Visual Analogue Scale(VAS)scores.Methods:A total of 80 periodontitis patients who received implant restoration in our hospital from May 2023 to May 2025 were selected as research subjects.They were randomly divided into an observation group and a control group using a random number table method,with 40 cases in each group.The observation group used the digital intraoral scanning impression technique to obtain impressions,while the control group used the traditional silicone rubber impression technique.The impression-taking time,the number of prostheses try-ins,implant survival rate,periodontal health indicators(probing depth,gingival index,bleeding index),and VAS scores(pain during treatment and comfort after restoration)were compared between the two groups.Results:The observation group was superior to the control group in terms of impression-taking time,the number of prostheses try-ins,and implant survival rate(p<0.05).Six months after restoration,the improvement in periodontal health indicators in the observation group was significantly better than that in the control group(p<0.05).In addition,the pain VAS score of the observation group during treatment was lower than that of the control group,and the comfort VAS score after restoration was higher than that of the control group(p<0.05).Conclusion:Digital intraoral scanning impression technology can effectively enhance the efficiency and success rate of implant restoration in periodontitis patients,improve periodontal health,alleviate patients’discomfort during treatment,and increase post-restoration comfort,demonstrating high clinical application value.展开更多
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi...Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.展开更多
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl...Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.展开更多
Rice panicle phenotyping is required in rice breeding for high yield and grain quality.To fully evaluate spikelet and kernel traits without threshing and hulling,using X-ray and RGB scanning,we developed an integrated...Rice panicle phenotyping is required in rice breeding for high yield and grain quality.To fully evaluate spikelet and kernel traits without threshing and hulling,using X-ray and RGB scanning,we developed an integrated rice panicle phenotyping system and a corresponding image analysis pipeline.We compared five methods of counting spikelets and found that Faster R-CNN achieved high accuracy(R~2 of 0.99)and speed.Faster R-CNN was also applied to indica and japonica classification and achieved 91%accuracy.The proposed integrated panicle phenotyping method offers benefit for rice functional genetics and breeding.展开更多
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not mee...Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples.展开更多
Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities o...Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities of supersaturated solid solution (SSS) of Zn-Al alloy and α' phase formed by quenching would reduce with the increase of Zn content and the precipitation of η-Zn phases even when aging at ambient temperature, so that the exothermic precipitation peak in DSC curve would disappear. The activation energy of the η-Zn precipitation and the reaction enthalpy were calculated and measured. The kinetics of α' decomposition or η-Zn formation was determined by XRD. The microstructure change during aging was observed by TEM.展开更多
Large areas of muddy sediments on the coastal shelves of China provide important samples for studying climate and ecological changes. Analysis of a large number of such samples, which is essential for systematic study...Large areas of muddy sediments on the coastal shelves of China provide important samples for studying climate and ecological changes. Analysis of a large number of such samples, which is essential for systematic study on environmental information recorded in mud areas because of complicated sedimentary environment and variable sedimentary rate, requires a fast and economical method. In this study, we investigated the potential of X-ray fluorescence core scanner (XRFS), a fast analytical instrument for measuring the elemental concentrations of muddy sediments, and observed a significant correlation between the element concentrations of muddy sediments determined by regular X-ray fluorescence spectrometer (XRF) and XRFS, respectively. The correlations are mainly determined by excitation energy of elements, but also influenced by solubility of element ions. Furthermore, we found a striking link between A1 concentrations and marine-originated organic carbon (MOC), a proxy of marine primary productivity. This indicates that MOC is partly controlled by sedimentary characteristics. Therefore, XRFS method has a good potential in fast analysis of a large number of muddy sediment samples, and it can also be used to calibrate MOC in ecological study of coastal seas.展开更多
The X-ray fluorescence(XRF)core scanning method is widely applied in studies of sedimentary paleoenvironments due to its convenient pretreatment,nondestructive characteristics,fast execution,continuous scanning,and hi...The X-ray fluorescence(XRF)core scanning method is widely applied in studies of sedimentary paleoenvironments due to its convenient pretreatment,nondestructive characteristics,fast execution,continuous scanning,and high resolution.XRF core scanning for sediments is commonly used in the studies on the South China Sea.This study compares XRF-scanned intensities and measured inductively coupled plasma(ICP)elemental contents of core CS11 in the northeast South China Sea deep basin.The results show that the analyzed elements can be separated into three classes.Class I includes elements with high correlation coefficients,such as Ca,Sr,and Zr;Class II contains elements with average correlation coefficients,such as Fe,Mn,Ti,and Cu;and Class III comprises elements with low correlation coefficients,such as K,Ni,Zn,Rb,and Al.In the South China Sea deep basin,pore water,compaction,and grain size have weak effects on the elemental intensities and contents of short core sediments.Hence,for elements with high correlation coefficients,a linear relationship model can be established by the least-squares method,in which the converted XRF intensities are approximately equal to the measured ICP contents.Based on the established log-ratio calibration model,the resulting ln(K/Ca),ln(Ti/Ca),ln(Fe/Ca),and ln(Zr/Ca)values generally display the same variation trends as the measured curves.The elemental contents and ratios produced by the linear model via the least-squares method and the log-ratio calibration model are expected to provide high-resolution data support for future paleoenvironmental research on the South China Sea deep basin.展开更多
As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not...As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not only helps assess the disease at the time of diagnosis but also aids evaluation of response to management,it is critical to examine the role of different modalities currently in use,such as baseline X-rays and computed tomography scans carefully.In this article,we will draw attention to the critical findings for the radiologist.Further,we will look at point of care ultrasound,an increasingly a popular tool in diagnostic medicine,as a component of COVID-19 management.展开更多
The three-dimensional(3 D) structures of pores directly affect the CH4 flow.Therefore,it is very important to analyze the3 D spatial structure of pores and to simulate the CH4 flow with the connected pores as the carr...The three-dimensional(3 D) structures of pores directly affect the CH4 flow.Therefore,it is very important to analyze the3 D spatial structure of pores and to simulate the CH4 flow with the connected pores as the carrier.The result shows that the equivalent radius of pores and throats are 1-16 μm and 1.03-8.9 μm,respectively,and the throat length is 3.28-231.25 μm.The coordination number of pores concentrates around three,and the intersection point between the connectivity function and the X-axis is 3-4 μm,which indicate the macro-pores have good connectivity.During the single-channel flow,the pressure decreases along the direction of CH4 flow,and the flow velocity of CH4 decreases from the pore center to the wall.Under the dual-channel and the multi-channel flows,the pressure also decreases along the CH4 flow direction,while the velocity increases.The mean flow pressure gradually decreases with the increase of the distance from the inlet slice.The change of mean flow pressure is relatively stable in the direction horizontal to the bedding plane,while it is relatively large in the direction perpendicular to the bedding plane.The mean flow velocity in the direction horizontal to the bedding plane(Y-axis) is the largest,followed by that in the direction horizontal to the bedding plane(X-axis),and the mean flow velocity in the direction perpendicular to the bedding plane is the smallest.展开更多
The layout and characteristics of the hard X-ray spectroscopy beamline(BL11B)at the Shanghai synchrotron radiation facility are described herein.BL11B is a bending-magnet beamline dedicated to conventional and millise...The layout and characteristics of the hard X-ray spectroscopy beamline(BL11B)at the Shanghai synchrotron radiation facility are described herein.BL11B is a bending-magnet beamline dedicated to conventional and millisecond-scale quick-scanning X-ray absorption fine structures.It is equipped with a cylindrical collimating mirror,a double-crystal monochromator comprising Si(111)and Si(311),a channel-cut quick-scanning Si(111)monochromator,a toroidal focusing mirror,and a high harmonics rejection mirror.It can provide 5-30 keV of X-rays with a photon flux of~5×10^(11)photons/s and an energy resolution of~1.31×10^(-4)at 10 keV.The performance of the beamline can satisfy the demands of users in the fields of catalysis,materials,and environmental science.This paper presents an overview of the beamline design and a detailed description of its performance and capabilities.展开更多
Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic ...Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic and inorganic components at nanometer level and is ideal for mapping over small areas to obtain a detailed analysis of structural variations. Thin sections of eggshells were scanned from the shell membrane (inner) to the cuticle (outer) surface. The data collected was used to produce two-dimensional maps showing microscopic changes within the different layers of the eggshell. The structural alterations ap- parently could have implications at the macroscopic level of the resulting eggshell. As the organic matrix is embedded within the eggshell this may contribute to the variations observed in calcite crystal form and texture, Structural information obtained about a biomaterial at different length scales is important in relating the structure to its functional properties. This knowledge and the principles behind the formation of biomaterials could be used in the attempt of bioengineering new systems.展开更多
基金supported in part by the National Natural Science Foundation of China(Nos.12305349,12235006,12027812)Shenzhen Science and Technology Program(No.JSGGKQTD20210831174329010)Guangdong Basic and Applied Basic Research Foundation(No.2021TQ06Y108).
文摘This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation transfer function(MTF),and detective quantum efficiency(DQE)of the DL-FPD are evaluated numerically using a linear cascade model.In addition,both the single-crystal(SC)and polycrystalline(PC)structures of MAPbI_(3)are investigated,along with various other key parameters such as the material thickness,electric field strength,X-ray beam spectrum,and electronic readout noise.The results demonstrate that SC perovskite consistently exhibits better performance than PC perovskite owing to fewer material defects.Increasing the layer thickness may decrease the MTF,but can also enhance the sensitivity and DQE.Moreover,appropriately increasing the external electric field within the material can improve the sensitivity,MTF,and DQE.Finally,reducing the electronic readout noise can significantly enhance the DQE for low-dose imaging.This study demonstrates the potential of high-quality dual-energy X-ray imaging using direct-conversion perovskite DL-FPDs.
基金supported by the National Natural Science Foundation of China(No.12175295)the National Key R&D Program of China(2021YFA1601000)the Shanghai Municipal Science and Technology Major Project。
文摘With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this study,the effects of X-ray beam size and photon energy on the accuracy of critical dimension measurements were investigated.Critical dimensions measured using beams with different spot sizes showed different deviations from the expected values.Beam sizes that were either too large or too small did not improve confidence intervals.As the incident energy increased,the X-ray transmission rate increased,while the scattering cross section decreased,resulting in a gradual decrease in the signal-to-noise ratio of the diffraction peaks,which reduced the accuracy of the CD-SAXS measurements.An optimal accuracy was obtained at 12 keV with a smaller beam size.Using an effective trapezoid model,the results yielded an average pitch of 100.4±0.2 nm,width of 49.8±0.2 nm,height of 130.0±0.2 nm,and a sidewall angle below 1.1°±0.1°.These results provide crucial guidance for the future development of CD-SAXS laboratories and the construction of X-ray machines as well as robust support for research in related fields.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2022YFA1603601,2021YFF0601203,and 2021YFA1600703)。
文摘The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.Synthetic aperture x-ray ghost imaging(SAXGI)is invented to achieve megapixel XGI with limited measurements,which is expected to implement XGI simultaneously with large field of view and low radiation exposure.In this paper,we experimentally investigate the effect of measurements reduction on the spatial resolution and image quality of SAXGI with standard sample and biomedical specimen.The results with a resolution chart demonstrated that at 360 measurements,SAXGI successfully retrieved the sample image of 1960×1960 pixels with spatial resolution of 4μm.With measurement reduction,the spatial resolution deteriorates but the sparser structures are still discernable.Even with measurements reduced to 10,a spatial resolution of 10μm can still be achieved by SAXGI.A biomedical sample of a fish specimen is employed to evaluate the method and the fish image of 2000×1000 pixels with an SSIM of 0.962 is reconstructed by SAXGI with 770measurements,corresponding to an accumulative exposure reduction of more than 2 times.With the measurements reduced to 10 which corresponds to 1/160 of the accumulative radiation exposure for conventional radiology,bulky structure like the fish skeleton can still be definitely discerned and the SSIM for the reconstructed image still retained 0.9179.Results of this paper demonstrate that measurements reduction is practicable for the radiation exposure reduction of the sample,which implicates that SAXGI with limited measurements is an efficient solution for low dose radiology.
基金funded by the National Natural Science Foundation of China(NNSFC)under Grant Numbers 42322408,42188101,and 42441809Additional support was provided by the Climbing Program of the National Space Science Center(NSSC,Grant No.E4PD3005)as well as the Specialized Research Fund for State Key Laboratories of China.
文摘A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-dimensional cusp boundary from a two-dimensional X-ray image because the detected X-ray signals will be integrated along the line of sight.In this work,a global magnetohydrodynamic code was used to simulate the X-ray images and photon count images,assuming an interplanetary magnetic field with a pure Bz component.The assumption of an elliptic cusp boundary at a given altitude was used to trace the equatorward and poleward boundaries of the cusp from a simulated X-ray image.The average discrepancy was less than 0.1 RE.To reduce the influence of instrument effects and cosmic X-ray backgrounds,image denoising was considered before applying the method above to SXI photon count images.The cusp boundaries were reasonably reconstructed from the noisy X-ray image.
基金Project(2023YFB4606200)supported by the National Key Research and Development Program of ChinaProject(2023-SSRF-HZ-503114-2)supported by Shanghai Synchrotron Radiation Facility,Instrument BL16U2,China。
文摘This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification.
基金supported by China Southern Power Grid Corporation(036000KC23090005(GDKJXM20231027)).
文摘This paper presents a programmable frequency scan algorithm based on harmonic balance.The core idea involves treating systems under perturbation as nonlinear time-periodic(NTP)systems.Steady-state harmonics are first solved via Newton-Raphson iteration through a set of nonlinear equations,and then input-output variables are selected to estimate the linear transfer function of the original NTP system without perturbations.The applications and insights of the proposed algorithm are discussed,particularly in guiding existing frequency scan algorithms,which are restricted by time-domain signal generation or measurement.This improvement is achieved through linear stability analysis of NTP systems with perturbations.
基金supported by the National Key R&D Program of China(No.2023YFB3709900)the National Nature Science Foundation of China(No.U22A20171)+1 种基金the China Baowu Low Carbon Metallurgy Innovation Foundation(No.BWLCF202315)the High Steel Center(HSC)at North China University of Technology and University of Science and Technology Beijing,China.
文摘Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfurization were analyzed.When the total aluminum content in the steel increased from 6 to 1100 ppm,the CaS content in CaO–Al_(2)O_(3) particles increased from 2.1wt%to 84.84wt%after the reaction for 90 s.Furthermore,when the silicon content in the steel increased from 0.01wt%to 2.20wt%,the CaS content in CaO–Al_(2)O_(3) particles increased from 1.53wt%to 79.01wt%after the reaction for 90 s.This indicates that the increase in the aluminum and silicon contents of the steel promoted the desulfurization of CaO–Al_(2)O_(3) particles.A kinetic model was established to predict the CaO–Al_(2)O_(3) particles composition,and the diffusion coefficient of sulfur in CaO–Al_(2)O_(3) particles was 9.375×10^(−10)m^(2)·s^(−1) at 1600℃,which provided a new method for the calculation of diffusion coefficient.
基金supported by National Natural Science Foundation of China(61921002 and 92163204)。
文摘Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics,and free electron radiation devices.Particularly,they are promising platforms for studying thermionic emission.It is illustrated that using vdW heterostructure-based thermionic emission can enhance heat transfer in vacuum devices.As a proof of concept,the approach is demonstrated to offer a promising solution for the long-standing overheating issue in X-ray tubes.Specifically,it is shown that the saturated target temperature of a 2000 W X-ray tube can be reduced from around 1200℃ to 490℃.Additionally,it is also demonstrated that by reducing the height of the Schottky barrier formed in the vdW heterostructures,the thermionic cooling performance can be enhanced.The findings pave the way for the development of high-power X-ray tubes.
文摘Objective:To explore the application effect of digital intraoral scanning impression technique in oral implant restoration for periodontitis patients and analyze its impact on patients’Visual Analogue Scale(VAS)scores.Methods:A total of 80 periodontitis patients who received implant restoration in our hospital from May 2023 to May 2025 were selected as research subjects.They were randomly divided into an observation group and a control group using a random number table method,with 40 cases in each group.The observation group used the digital intraoral scanning impression technique to obtain impressions,while the control group used the traditional silicone rubber impression technique.The impression-taking time,the number of prostheses try-ins,implant survival rate,periodontal health indicators(probing depth,gingival index,bleeding index),and VAS scores(pain during treatment and comfort after restoration)were compared between the two groups.Results:The observation group was superior to the control group in terms of impression-taking time,the number of prostheses try-ins,and implant survival rate(p<0.05).Six months after restoration,the improvement in periodontal health indicators in the observation group was significantly better than that in the control group(p<0.05).In addition,the pain VAS score of the observation group during treatment was lower than that of the control group,and the comfort VAS score after restoration was higher than that of the control group(p<0.05).Conclusion:Digital intraoral scanning impression technology can effectively enhance the efficiency and success rate of implant restoration in periodontitis patients,improve periodontal health,alleviate patients’discomfort during treatment,and increase post-restoration comfort,demonstrating high clinical application value.
基金supported by the NSFC under Grant No.62474169the National Key Research and Development Program of China under Grant No.2024YFB3212200the funding from USTC under Grant Nos.WK2100000025,KY2190000003,and KY2190000006。
文摘Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors.
基金supports from the National Natural Science Foundation of China(22375220,U2001214,22471302)the Guangdong Basic and Applied Basic Research Foundation(2024B1515020101)Open Project Fund from State Key Laboratory of Optoelectronic Materials and Technologies(OEMT-2024-KF-08).
文摘Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses.
基金supported by the National Key Research and Development Program of China(2016YFD0100101-18)the National Natural Science Foundation of China(31770397,31701317)the Fundamental Research Funds for the Central Universities(2662017PY058)。
文摘Rice panicle phenotyping is required in rice breeding for high yield and grain quality.To fully evaluate spikelet and kernel traits without threshing and hulling,using X-ray and RGB scanning,we developed an integrated rice panicle phenotyping system and a corresponding image analysis pipeline.We compared five methods of counting spikelets and found that Faster R-CNN achieved high accuracy(R~2 of 0.99)and speed.Faster R-CNN was also applied to indica and japonica classification and achieved 91%accuracy.The proposed integrated panicle phenotyping method offers benefit for rice functional genetics and breeding.
基金Supported by the Basic Scientific Fund for National Public Research Institutes of China(Nos.GY02-2011T10,2015P07)the Qingdao Talent Program(No.13-CX-20)+1 种基金the National Natural Science Foundation of China(Nos.31100567,41176061)the National Natural Science Foundation for Creative Groups(No.41521064)
文摘Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples.
文摘Decomposition processes of the quenched Zn-Al alloys were studied by differential scanning calorimetry (DSC), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the stabilities of supersaturated solid solution (SSS) of Zn-Al alloy and α' phase formed by quenching would reduce with the increase of Zn content and the precipitation of η-Zn phases even when aging at ambient temperature, so that the exothermic precipitation peak in DSC curve would disappear. The activation energy of the η-Zn precipitation and the reaction enthalpy were calculated and measured. The kinetics of α' decomposition or η-Zn formation was determined by XRD. The microstructure change during aging was observed by TEM.
基金supported by the National Basic Research Program of China(2010CB428902)National Natural Science Foundation of China(40876088)
文摘Large areas of muddy sediments on the coastal shelves of China provide important samples for studying climate and ecological changes. Analysis of a large number of such samples, which is essential for systematic study on environmental information recorded in mud areas because of complicated sedimentary environment and variable sedimentary rate, requires a fast and economical method. In this study, we investigated the potential of X-ray fluorescence core scanner (XRFS), a fast analytical instrument for measuring the elemental concentrations of muddy sediments, and observed a significant correlation between the element concentrations of muddy sediments determined by regular X-ray fluorescence spectrometer (XRF) and XRFS, respectively. The correlations are mainly determined by excitation energy of elements, but also influenced by solubility of element ions. Furthermore, we found a striking link between A1 concentrations and marine-originated organic carbon (MOC), a proxy of marine primary productivity. This indicates that MOC is partly controlled by sedimentary characteristics. Therefore, XRFS method has a good potential in fast analysis of a large number of muddy sediment samples, and it can also be used to calibrate MOC in ecological study of coastal seas.
基金This study was jointly supported by the National Natural Science Foundation of China(Nos.41576058 and 41976192)the Project of China Geological Survey(No.DD20191010)+2 种基金the Shandong Provincial Natural Science Foundation of China(No.ZR2020MD061)the Open Foundation of the State Key Laboratory of Loess and Quaternary Geology(Nos.SKLLQG1707 and SKLLQG1805)the Strategic Priority Research Program of Chinese Academy of Sciences(No.XDB40000000).
文摘The X-ray fluorescence(XRF)core scanning method is widely applied in studies of sedimentary paleoenvironments due to its convenient pretreatment,nondestructive characteristics,fast execution,continuous scanning,and high resolution.XRF core scanning for sediments is commonly used in the studies on the South China Sea.This study compares XRF-scanned intensities and measured inductively coupled plasma(ICP)elemental contents of core CS11 in the northeast South China Sea deep basin.The results show that the analyzed elements can be separated into three classes.Class I includes elements with high correlation coefficients,such as Ca,Sr,and Zr;Class II contains elements with average correlation coefficients,such as Fe,Mn,Ti,and Cu;and Class III comprises elements with low correlation coefficients,such as K,Ni,Zn,Rb,and Al.In the South China Sea deep basin,pore water,compaction,and grain size have weak effects on the elemental intensities and contents of short core sediments.Hence,for elements with high correlation coefficients,a linear relationship model can be established by the least-squares method,in which the converted XRF intensities are approximately equal to the measured ICP contents.Based on the established log-ratio calibration model,the resulting ln(K/Ca),ln(Ti/Ca),ln(Fe/Ca),and ln(Zr/Ca)values generally display the same variation trends as the measured curves.The elemental contents and ratios produced by the linear model via the least-squares method and the log-ratio calibration model are expected to provide high-resolution data support for future paleoenvironmental research on the South China Sea deep basin.
文摘As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not only helps assess the disease at the time of diagnosis but also aids evaluation of response to management,it is critical to examine the role of different modalities currently in use,such as baseline X-rays and computed tomography scans carefully.In this article,we will draw attention to the critical findings for the radiologist.Further,we will look at point of care ultrasound,an increasingly a popular tool in diagnostic medicine,as a component of COVID-19 management.
基金financially supported by the National Key Research and Development Plan(No.2018YFB0605601)the National Natural Science Foundation of China(No.41972168)。
文摘The three-dimensional(3 D) structures of pores directly affect the CH4 flow.Therefore,it is very important to analyze the3 D spatial structure of pores and to simulate the CH4 flow with the connected pores as the carrier.The result shows that the equivalent radius of pores and throats are 1-16 μm and 1.03-8.9 μm,respectively,and the throat length is 3.28-231.25 μm.The coordination number of pores concentrates around three,and the intersection point between the connectivity function and the X-axis is 3-4 μm,which indicate the macro-pores have good connectivity.During the single-channel flow,the pressure decreases along the direction of CH4 flow,and the flow velocity of CH4 decreases from the pore center to the wall.Under the dual-channel and the multi-channel flows,the pressure also decreases along the CH4 flow direction,while the velocity increases.The mean flow pressure gradually decreases with the increase of the distance from the inlet slice.The change of mean flow pressure is relatively stable in the direction horizontal to the bedding plane,while it is relatively large in the direction perpendicular to the bedding plane.The mean flow velocity in the direction horizontal to the bedding plane(Y-axis) is the largest,followed by that in the direction horizontal to the bedding plane(X-axis),and the mean flow velocity in the direction perpendicular to the bedding plane is the smallest.
文摘The layout and characteristics of the hard X-ray spectroscopy beamline(BL11B)at the Shanghai synchrotron radiation facility are described herein.BL11B is a bending-magnet beamline dedicated to conventional and millisecond-scale quick-scanning X-ray absorption fine structures.It is equipped with a cylindrical collimating mirror,a double-crystal monochromator comprising Si(111)and Si(311),a channel-cut quick-scanning Si(111)monochromator,a toroidal focusing mirror,and a high harmonics rejection mirror.It can provide 5-30 keV of X-rays with a photon flux of~5×10^(11)photons/s and an energy resolution of~1.31×10^(-4)at 10 keV.The performance of the beamline can satisfy the demands of users in the fields of catalysis,materials,and environmental science.This paper presents an overview of the beamline design and a detailed description of its performance and capabilities.
文摘Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic and inorganic components at nanometer level and is ideal for mapping over small areas to obtain a detailed analysis of structural variations. Thin sections of eggshells were scanned from the shell membrane (inner) to the cuticle (outer) surface. The data collected was used to produce two-dimensional maps showing microscopic changes within the different layers of the eggshell. The structural alterations ap- parently could have implications at the macroscopic level of the resulting eggshell. As the organic matrix is embedded within the eggshell this may contribute to the variations observed in calcite crystal form and texture, Structural information obtained about a biomaterial at different length scales is important in relating the structure to its functional properties. This knowledge and the principles behind the formation of biomaterials could be used in the attempt of bioengineering new systems.