Objective: To study the effects of heparin-coated stent (Wiktor-I) on recovering the balance between endothelin- 1(ET- 1) and calcitonin gene-related peptide (CGRP) both in the plasma of coronary sinus and peripheral ...Objective: To study the effects of heparin-coated stent (Wiktor-I) on recovering the balance between endothelin- 1(ET- 1) and calcitonin gene-related peptide (CGRP) both in the plasma of coronary sinus and peripheral vein after stent implantation. Methods: The patients with coronary artery disease (n=30) were divided into non-coated stent (NCS) group (n=16) and heparin-coated stent (HCS) group (n=14). Circulating ET-1 and CGRP levels were measured by radioimmunoassay (RIA) in the 2 groups at the paired sampling sites, namely the coronary sinus (Cs) and peripheral vein (Pv). The ratio of ET/CGRP was also calculated to reflect the balance of ET and CORP. Results: In NCS group plasma ET-1 concentrations exhibited 2 peaks at 0 mm and 12 h after stent implantation, CORP levels were highly consistent with that of ET-1, and the ratio of ET/CGRP increased markedly at post-PTCA 5 mm, persisting until post-stent 12 h. While in HCS group ET-1 levels and the ratio of ET/CGRP were decreased dramatically compared with that of NCS group at 5 min,10 mm and 12 h post-stent (P<0.05, P<0.01 and P<0.05, respectively=. There was no remarkable difference of CGRP levels between the 2 groups. Conclusions: Heparin-coated stent can decrease the post-stent circulating ET-1 levels and recover the balance between ET-1 and CGRP.展开更多
文摘Objective: To study the effects of heparin-coated stent (Wiktor-I) on recovering the balance between endothelin- 1(ET- 1) and calcitonin gene-related peptide (CGRP) both in the plasma of coronary sinus and peripheral vein after stent implantation. Methods: The patients with coronary artery disease (n=30) were divided into non-coated stent (NCS) group (n=16) and heparin-coated stent (HCS) group (n=14). Circulating ET-1 and CGRP levels were measured by radioimmunoassay (RIA) in the 2 groups at the paired sampling sites, namely the coronary sinus (Cs) and peripheral vein (Pv). The ratio of ET/CGRP was also calculated to reflect the balance of ET and CORP. Results: In NCS group plasma ET-1 concentrations exhibited 2 peaks at 0 mm and 12 h after stent implantation, CORP levels were highly consistent with that of ET-1, and the ratio of ET/CGRP increased markedly at post-PTCA 5 mm, persisting until post-stent 12 h. While in HCS group ET-1 levels and the ratio of ET/CGRP were decreased dramatically compared with that of NCS group at 5 min,10 mm and 12 h post-stent (P<0.05, P<0.01 and P<0.05, respectively=. There was no remarkable difference of CGRP levels between the 2 groups. Conclusions: Heparin-coated stent can decrease the post-stent circulating ET-1 levels and recover the balance between ET-1 and CGRP.