期刊文献+
共找到63篇文章
< 1 2 4 >
每页显示 20 50 100
Enhanced Mechanical Properties of Friction Stir Welded 5083Al-H19 Joints with Additional Water Cooling 被引量:19
1
作者 B.B.Wang F.F.Chen +3 位作者 F.Liu W.G.Wang P.Xue Z.Y.Ma 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2017年第9期1009-1014,共6页
3-mm-thick 5083Al-H19 rolled plates were friction stir welded(FSW) at tool rotation rates of 800 and200 rpm with and without additional water cooling. With decreasing the rotation rate and applying water cooling, soft... 3-mm-thick 5083Al-H19 rolled plates were friction stir welded(FSW) at tool rotation rates of 800 and200 rpm with and without additional water cooling. With decreasing the rotation rate and applying water cooling, softening in the FSW joint was significantly reduced. At a low rotation rate of 200 rpm with additional water cooling, almost no obvious softening was observed in the FSW joint, and therefore a FSW5083Al-H19 joint with nearly equal strength to the base material(BM) was obtained. Furthermore, the grains in the nugget zone were considerably refined with reducing the heat input and ultrafine equiaxed grains of about 800 nm were obtained in the lowest heat input condition. This work provides an effective method to achieve high property FSW joints of precipitate-hardened and work-hardened Al alloys. 展开更多
关键词 Friction stir welding Aluminum alloy water cooling Microstructure Mechanical property
原文传递
Application of a water cooling treatment and its effect on coal-based reduction of high-chromium vanadium and titanium iron ore 被引量:3
2
作者 Song-tao Yang Mi Zhou +3 位作者 Tao Jiang Shan-fei Guan Wei-jun Zhang Xiang-xin Xue 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第12期1353-1359,共7页
A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), ... A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), S removal ratio (Rs), and P removal ratio (Rp) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350℃ were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved the η, Rs, and Rp in the coal-based reduction of V-Ti-Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70 μm at 1350℃, which is substantially larger than the minimum particle size required (20 μm) for magnetic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V-Ti-Cr iron ore followed by magnetic separation. 展开更多
关键词 MAGNETITE ore reduction water cooling METALLIZATION magnetic separation
在线阅读 下载PDF
Probe design for measuring total temperature of combustor outlet based on water cooling 被引量:1
3
作者 ZHAO Kai LI Feng +2 位作者 LU Fuguo ZHOU Tao YANG Hongyu 《航空动力学报》 EI CAS CSCD 北大核心 2018年第9期2084-2092,共9页
To obtain the outlet temperature of combustor,a kind of high-temperature and water cooling thermocouple was designed.The main factors affecting the results of thermocouple measurement were analyzed after numerical sim... To obtain the outlet temperature of combustor,a kind of high-temperature and water cooling thermocouple was designed.The main factors affecting the results of thermocouple measurement were analyzed after numerical simulation.Results showed that the high-temperature water cooling thermocouple can achieve high temperature measurement under the condition of 2 400 K.With the increase of the distance between the water cooling structure and the stagnation cover,the temperature measurement result was more accurate,and the increase in the area ratio of the inlet and outlet of the stagnation cover within a reasonable range can make the measurement results more accurate.The surface emissivity of the measuring point had a great influence on the radiation error.The pressure and flow rate of cooling water can be effectively reduced after adding zirconia coating onto the surface of the rake body. 展开更多
关键词 PROBE total temperature combustion chamber water cooling THERMOCOUPLE
原文传递
An Experimental Study on Water Curtain Cooling and Infrared Concealment Effects
4
作者 Nenglin Yuan Meinan Liu +1 位作者 Yitao Zou Hong Shi 《哈尔滨工程大学学报(英文版)》 2025年第3期567-579,共13页
The water curtain spray system of the ship helps reduce surface thermal load and lowers thermal infrared radiation, notably enhancing the stealth and survivability of naval ships. The performance of the water curtain ... The water curtain spray system of the ship helps reduce surface thermal load and lowers thermal infrared radiation, notably enhancing the stealth and survivability of naval ships. The performance of the water curtain spray system is largely influenced by the density of the nozzles and their installation height. Therefore, a test platform was established to investigate these critical influencing factors, employing an orthogonal design methodology for the experimental study. Specifically, the study evaluated the effects of varying distances to the steel plate target and different injection heights on the cooling performance of the system. Results demonstrate that using one nozzle per 4 square meters of the ship's surface area effectively lowers the surface temperature, bringing it closer to the ambient background temperature. This nozzle configuration creates irregular infrared heat patterns, which complicate the task for infrared detectors to discern the ship's outline, thus enhancing its infrared stealth. Additionally, maintaining the nozzle installation height within 0.6 m to prevent the temperature difference between the steel plate and the background temperature from exceeding 4 K. Moreover, as the infrared imaging distance increases from 3 to 9 m, the temperature difference measured by the thermocouple and the infrared imager increases by 141.27%. Furthermore, with the increase in infrared imaging distance, the infrared temperature of the target steel plate approaches the background temperature, indicating improved detectability. These findings have significantly enhanced the stealth capabilities of naval ships, maximizing their immunity to infrared-guided weapon attacks. Moreover, their importance in improving the survivability of ships on the water surface cannot be underestimated. 展开更多
关键词 Ship water curtain stealth water curtain nozzles water curtain cooling Infrared shielding Infrared stealth
在线阅读 下载PDF
Water cooling radiator for solid state power supply in fast-axial-flow C02 laser 被引量:3
5
作者 Heng ZHAO Bo LI +2 位作者 Wenjin WANG Yi HU Youqing WANG 《Frontiers of Optoelectronics》 EI CSCD 2016年第4期585-591,共7页
Two different flow channel configurations on thermal resistances associated with the behavior of cooling of power device were studied in this paper. ANSYS Icepak 14.0 has been adopted as a numerical simulation tool. T... Two different flow channel configurations on thermal resistances associated with the behavior of cooling of power device were studied in this paper. ANSYS Icepak 14.0 has been adopted as a numerical simulation tool. The simulation results from this study showed that the shapes of channels in cooling radiator play an important role in the thermal management of water cooling radiation system. The optimal channel design could improve the heat- dissipating efficiency by 80% in water cooling radiation system. The result also indicated that the thermal resistance of heat sinks decreased with the volumetric flow rate and the number of cylindrical columns in the flow channel. Experimental results were obtained under certain channel configurations and volume rates. Moreover, the results of numerical simulation can be explained well by the experimental results. 展开更多
关键词 heat spreader water cooling turbulencegenerator Icepak software
原文传递
Technical Research on Process Optimization of Cooling Tower in Circulating Water System
6
作者 LIANG Jin 《外文科技期刊数据库(文摘版)工程技术》 2021年第7期269-271,共5页
Since the treatment of circulating water will directly affect the discharge of chemical enterprises, the treatment of circulating water is an important link in the development of chemical enterprises, and the cooling ... Since the treatment of circulating water will directly affect the discharge of chemical enterprises, the treatment of circulating water is an important link in the development of chemical enterprises, and the cooling tower is the decisive factor to determine the temperature of circulating water. Therefore, it is necessary to analyze the problems existing in the cooling tower, and put forward corresponding countermeasures for the problems existing in the operation of circulating water cooling tower, so as to explore a reasonable solution. 展开更多
关键词 energy consumption circulating water cooling tower OPTIMIZATION
原文传递
Optimization of circulating cooling water systems based on chance constrained programming 被引量:5
7
作者 Bo Liu Yufei Wang Xiao Feng 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期167-178,共12页
Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained u... Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained under deterministic conditions may not be stable and economical. This paper studies the optimization of circulating cooling water systems under uncertain circumstance. To improve the reliability of the system and reduce the water and energy consumption, the influence of different uncertain parameters is taken into consideration. The chance constrained programming method is used to build a model under uncertain conditions, where the confidence level indicates the degree of constraint violation. Probability distribution functions are used to describe the form of uncertain parameters. The objective is to minimize the total cost and obtain the optimal cooling network configuration simultaneously.An algorithm based on Monte Carlo method is proposed, and GAMS software is used to solve the mixed integer nonlinear programming model. A case is optimized to verify the validity of the model. Compared with the deterministic optimization method, the results show that when considering the different types of uncertain parameters, a system with better economy and reliability can be obtained(total cost can be reduced at least 2%). 展开更多
关键词 Circulating cooling water system UNCERTAINTY Chance constrained programming DESIGN OPTIMIZATION SIMULATION
在线阅读 下载PDF
Effect of chloride ions on 316L stainless steel in cyclic cooling water 被引量:5
8
作者 Zuojia LIU Xuequn CHENG +1 位作者 Shengjie LU Xiaogang LI 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2010年第6期431-438,共8页
The effect of Cl^- on the 316L stainless steel in simulated cooling water has been studied using polarization curves, electrochemical impedance spectroscopy (EIS), Mott- Schottky plot and scanning electron microsco... The effect of Cl^- on the 316L stainless steel in simulated cooling water has been studied using polarization curves, electrochemical impedance spectroscopy (EIS), Mott- Schottky plot and scanning electron microscopy (SEM) techniques. Cl^- concentrations vary from 200 to 900 mg/L. Results reveal that the corrosion resistance increases with the decrease of Cl^- concentration in simulated cooling water. The increase of Cl^- concentration leads to the shift of the corrosion potential towards the positive direction. Mott-Schottky curves show that in the passive film, Cr2Oa and FeO at the inner layer exhibit P-type but Fe2O3 and CrOa (CrO4^2-) N-type semiconductive properties. The SEM/EDX data demonstrate that elements such as Fe, O, C, Si and Cl as well as the presence of calcium and aluminum are presented on the surface of the metal. 展开更多
关键词 Polarization curve EIS Mott-Schottky plot SEM/EDX Simulated cyclic cooling water
原文传递
Effect of temperature, chloride ions and sulfide ions on the electrochemical properties of 316L stainless steel in simulated cooling water 被引量:3
9
作者 李金波 翟文 +1 位作者 郑茂盛 朱杰武 《Journal of Pharmaceutical Analysis》 SCIE CAS 2008年第1期33-37,60,共6页
The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarizati... The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days’ immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve’s change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6 mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times. 展开更多
关键词 stainless steel TEMPERATURE chloride ions sulfide ions simulated cooling water
在线阅读 下载PDF
Application of Cooling Water in Controlled Runout Table Cooling on Hot Strip Mill 被引量:2
10
作者 LIUZheng-dong IVSamarasekera 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2004年第3期15-23,共9页
The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to ... The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to study the heat transfer by water jet impingement boiling during runout,apilot facility was constructed at the University of British Columbia.On this pilot facility,the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters,such as cooling water temperature,water jet impingement velocity,initial strip temperature,water flow rate,water nozzle diameter and array of water nozzles,on the heat transfer of heated strip.The results obtained contribute to the optimization of cooling water during runout. 展开更多
关键词 cooling water controlled runout table hot strip mill
在线阅读 下载PDF
Hydroxyl carboxylate based non-phosphorus corrosion inhibition process for reclaimed water pipeline and downstream recirculating cooling water system 被引量:5
11
作者 Jun Wang Dong Wang Deyin Hou 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第1期13-21,共9页
A combined process was developed to inhibit the corrosion both in the pipeline of reclaimed water supplies(PRWS) and in downstream recirculating cooling water systems(RCWS)using the reclaimed water as makeup. Hydr... A combined process was developed to inhibit the corrosion both in the pipeline of reclaimed water supplies(PRWS) and in downstream recirculating cooling water systems(RCWS)using the reclaimed water as makeup. Hydroxyl carboxylate-based corrosion inhibitors(e.g.,gluconate, citrate, tartrate) and zinc sulfate heptahydrate, which provided Zn^2+ as a synergistic corrosion inhibition additive, were added prior to the PRWS when the phosphate(which could be utilized as a corrosion inhibitor) content in the reclaimed water was below 1.7 mg/L, and no additional corrosion inhibitors were required for the downstream RCWS.Satisfactory corrosion inhibition was achieved even if the RCWS was operated under the condition of high numbers of concentration cycles. The corrosion inhibition requirement was also met by the appropriate combination of PO4^3- and Zn^2+ when the phosphate content in the reclaimed water was more than 1.7 mg/L. The process integrated not only water reclamation and reuse, and the operation of a highly concentrated RCWS, but also the comprehensive utilization of phosphate in reclaimed water and the application of non-phosphorus corrosion inhibitors. The proposed process reduced the operating cost of the PRWS and the RCWS, and lowered the environmental hazard caused by the excessive discharge of phosphate. Furthermore, larger amounts of water resources could be conserved as a result. 展开更多
关键词 Hydroxyl carboxylate Reclaimed water Pipeline Corrosion Recirculating cooling water system Non-phosphorus
原文传递
CFD Analysis and Optimization of a Diesel Engine Cooling Water Jacket 被引量:2
12
作者 Shunshun Qin Chengfen Xie +3 位作者 Song Li Qi Yang Jianwei Chen Ke Sun 《Fluid Dynamics & Materials Processing》 EI 2022年第3期647-659,共13页
The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.... The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail. 展开更多
关键词 Diesel engine cooling water jacket CFD
在线阅读 下载PDF
Effects of Nutrients on Biofouling Formation and Preponderant Bacteria Diversity in Recirculating Cooling Water System 被引量:2
13
作者 Ma Tao Liu Fang +1 位作者 Zhang Guizhi Zhao Chaocheng (College of Chemistry and Chemical Engineering,China University of Petroleum,Qingdao 266555) 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2010年第4期57-62,共6页
A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation an... A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation and preponderant bacteria diversity in the recirculatiug cooling water system. Carbon source was demonstrated to be the most significant determinant affecting the biofouling formation. A minimum biofouling outcome was obtained when BOD2, NHa+-N and TP were 25, 10, and 1 mg/L, respectively. Then the preponderant bacteria strains in biofouling mass under two typical culture conditions (negative and favorable) were identified applying both traditional biochemical methods and further molecular biology technology with phylogenetic affiliation analysis, which indicated that Enterobacteriaceae Enterobacter, Micrococcaceae Staphylococcus, Bacillaceae Bacillus, Enterobacteriaceae Proteus, Neisseriaceae Neisseria and Pseudomonadaceae Pseudomonas were dominant under negative condition, while Enterobacteriaceae Klebsiella, Enterobacteriaceae Enterobacter and Microbacterium - under favorable one. 展开更多
关键词 recirculating cooling water BIOFOULING numerical analysis polymerase chain reaction
暂未订购
Influence of CO_(2) inleakage on the slight-alkalization of generator internal cooling water 被引量:1
14
作者 Tianping Wang Xuxiang Jia +1 位作者 Yu Wang Chunsong Ye 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第8期91-97,共7页
The slight-alkalization of generator internal cooling water(GICW)is widely used to inhibit the corrosion of hollow copper conductor and thereby ensure the safe operation of the generator.CO_(2) inleakage is increasing... The slight-alkalization of generator internal cooling water(GICW)is widely used to inhibit the corrosion of hollow copper conductor and thereby ensure the safe operation of the generator.CO_(2) inleakage is increasingly identified as a potential security risk for GICW system.In this paper,the influence of CO_(2) inleakage on the slight-alkalization of GICW was theoretically discussed.Based on the equilibriums of the CO_(2)-NaOH-H_(2)O system,CO_(2) inleakage saturation was derived to quantify the amount of the dissolved CO_(2) in GICW.This parameter can be directly calculated with the measured conductivity and the[Na+]of GICW.The influence of CO_(2) inleakage on the slight-alkalization conditioning of GICW and the measurement of its water quality parameters were then analyzed.The more severe the inleakage,the narrower the water quality operation ranges of GICW,resulting in the more difficult the slight-alkalization conditioning of GICW.The temperature calibrations of the conductivity and the pH value of GICW show nonlinear correlations with the amount of CO_(2) inleakage and the NaOH dosage.This study provides insights into the influence of CO_(2) inleakage on the slight-alkalization of GICW,which can serve as the theoretical basis for the actual slight-alkalization when CO_(2) inleakage occurs. 展开更多
关键词 Generator internal cooling water(GICW) Hollow copper conductor CO_(2)inleakage Slight-alkalization Temperature calibration
在线阅读 下载PDF
Laccase Immobilized on Mesoporous Silica Materials and Its Corrosion Inhibition Performance in Circulating Cooling Water System 被引量:2
15
作者 Liu Fang Lü Yucui +3 位作者 Zhong Huiyun Zhang Shuang Fan Fengtao Zhao Chaocheng 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2015年第4期8-19,共12页
Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter... Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter is 2.55 nm, while the specific surface area is 1 088.9 m2/g. Mesoporous SiO_2 microspheres adsorb glutaraldehyde and immobilize laccase by means of the aldehyde group in glutaral which can react with the amidogen of laccase. The immobilization conditions were optimized at a glutaraldehyde concentration of 0.75%, a crosslinking time of 8 h, a laccase concentration of 0.04 L/L and an immobilization time of 10 h. When diesel leakage concentration was 80 mg/L, the highest corrosion inhibition efficiency of immobilized laccase reached 49.23%, which was slightly lower than the corrosion inhibition efficiency of free laccase(59%). The diesel degradation ratio could reach up to 45%. It has been proved that the immobilized laccase could degrade diesel to inhibit corrosion. 展开更多
关键词 diesel leakage circulating cooling water mesoporous SiO_2 microspheres laccase immobilization corrosion inhibition
在线阅读 下载PDF
Calculation of Mass Concrete Temperature Containing Cooling Water Pipe Based on Substructure and Iteration Algorithm
16
作者 Heng Zhang Chao Su +2 位作者 Zhizhong Song Zhenzhong Shen Huiguang Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期813-826,共14页
Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for... Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development. 展开更多
关键词 Fourier equation cooling water pipe mass concrete iteration algorithm
在线阅读 下载PDF
Effects of air-atomized water spray cooling device structure on the quenching process,microstructure,and properties of wear-resistant steel
17
作者 WEN Shibo WU Jianfeng ZHU Jianhua 《Baosteel Technical Research》 CAS 2022年第2期35-41,共7页
With its high strength and hardness, wear-resistant steel has become an important material in the field of construction machinery manufacturing.Given that quenching technology is a crucial component of wear-resistant ... With its high strength and hardness, wear-resistant steel has become an important material in the field of construction machinery manufacturing.Given that quenching technology is a crucial component of wear-resistant steel production, the selection of the cooling method to be used during this process is important.In this study, the feasibility of quenching wear-resistant steel by air-atomized water spray cooling was studied, and the cooling rate, microstructure, and hardness of wear-resistant steel under various cooling device structures were analyzed.The results reveal that the air-atomized water spray cooling method is an effective technique in quenching wear-resistant steel.Furthermore, martensite and uniform hardness were obtained by the air-atomized water spray cooling technique.As the space between the nozzles in each row in the device increased, the cooling rate was reduced during quenching.Meanwhile, the martensite content decreased, and more carbides were observed in the martensitic structure.A mixture comprising self-tempered martensite and bainite was formed at a large distance over a longer period of time.All these factors resulted in lower hardness and worse property uniformity. 展开更多
关键词 wear-resistant steel air-atomized water spray cooling cooling rate MICROSTRUCTURE HARDNESS
在线阅读 下载PDF
Cooling Water Flow Rate Calculation for Hearth of Large Blast Furnaces
18
作者 LI Hengxu CHE Yiunan +2 位作者 ZHOU Zhe WANG Qi WANG Hongtao 《China's Refractories》 CAS 2015年第2期16-20,共5页
The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requ... The cooling water flow rate for hearth of large blast furnaces was calculated by simulation. The results show that the cooling water flow rate shall be above 4 200m3/ h for hearth of large blast furnaces; to meet requirements of the increasing smelting intensity and to ensure the safety at the end of the first campaign,the designed maximum cooling water flow rate should be 5 900m3/ h; according to the flow distribution stability and the calculated resistance loss,hearth cooling stave pipes with the specification of 76 mm × 6 mm shall be adopted to assure the flow velocity in pipes of hearth cooling stave in the range of 1. 9- 2. 3 m / s. 展开更多
关键词 hearth of blast furnaces cooling water flow rate simulation calculation
在线阅读 下载PDF
Application and Development Prospect of "Multifunctional Biopharmaceutical Water Treatment Agent" in Circulating Cooling Water Treatment of Power Plant
19
作者 ZHANG Zhongcheng ZHANG Houlin 《外文科技期刊数据库(文摘版)自然科学》 2021年第11期057-061,共7页
As is known to all, resource conservation and environmental protection have become the main theme of our society today. Industrial enterprises need to use a large amount of water resources. The issue of "water re... As is known to all, resource conservation and environmental protection have become the main theme of our society today. Industrial enterprises need to use a large amount of water resources. The issue of "water resource conservation and environmental protection" in industrial cooling circulating water treatment is beginning to be paid more and more attention. In this paper, the patent product "a multifunctional bio-pharmaceutical water treatment agent" with high efficiency, energy conservation and environmental protection is cited to explore its application and development prospect in industrial cooling circulating water treatment of power plants. In the future, with the improvement of biological water treatment agent and its supporting equipment, the biological water treatment agent will be promoted and popularized to better protect the water environment. 展开更多
关键词 biological water treatment agent circulating cooling water treatment APPLICATION prospects for de
原文传递
Effect of cooling conditions on corrosion resistance of friction stir welded 2219-T62 aluminum alloy thick plate joint 被引量:13
20
作者 Wei-feng XU Jun MA +2 位作者 Miao WANG Hong-jian LU Yu-xuan LUO 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2020年第6期1491-1499,共9页
Friction stir welding (FSW) with water cooling and air cooling was used to weld 2219-T62 aluminum alloy joints with a thickness of 20 mm. The effect of cooling conditions on the corrosion resistance of joints in 3.5% ... Friction stir welding (FSW) with water cooling and air cooling was used to weld 2219-T62 aluminum alloy joints with a thickness of 20 mm. The effect of cooling conditions on the corrosion resistance of joints in 3.5% NaCl solution was investigated using the open circuit potential (OCP), the potentiodynamic polarization, and the corrosion morphology after immersing for different time. And the precipitates distribution was characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results reveal that the weld nugget zone (WNZ) owning positive potential, lower corrosion current density and fine and uniform precipitates, is much more difficult to corrode than the heat affected zone (HAZ) and the base metal (BM). Compared with air-cooled joint, the water-cooled joint has better corrosion resistance. In addition, the results of microstructure observation show that the potential, distribution and size of second phase particles determine the corrosion resistance of FSW AA2219 alloy joints in chlorine-contained solution. 展开更多
关键词 friction stir welding aluminum alloy air cooling water cooling corrosion resistance second phase particles
在线阅读 下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部