Test system designed for WLSF pads of HERD calorimeter cell
1
作者 Wenjie Duan Xingzhu Cui +6 位作者 Xin Liu Sen Guo Bing Lu Yongwei Dong Jilong Tang Zhipeng Wei Qun Hao 《Radiation Detection Technology and Methods》 CSCD 2024年第3期1366-1376,共11页
Purpose In order to avoiding the potential radiation harm caused by X-ray tube to the crew,and meeting the testing requirements for WLSF pad of Calorimeter Cell in the High Energy cosmic-Radiation Detection facility(H... Purpose In order to avoiding the potential radiation harm caused by X-ray tube to the crew,and meeting the testing requirements for WLSF pad of Calorimeter Cell in the High Energy cosmic-Radiation Detection facility(HERD).Method Designed a testing system,which is composed by LED,LYSO crystal,and narrow bandpass filter.The stability of the testing system is validated by conducting long-term measurements of signal amplitudes using a PMT waveform sampling module.Results and conclusions The result showed that the deviation levels of the WLSF Pad’s light output test results are all less than 5%.The linear relationship between the results of testing system and the results obtained with the cosmic ray test has demonstrated the effectiveness of the testing system,which promises the further application in large-scale WLSF pads performance testing. 展开更多
关键词 HERD LYSO wlsf Optical output
原文传递
宇宙线塑料闪烁望远镜系统时间特性的研究
2
作者 黄胜利 许咨宗 +1 位作者 李澄 曾辉 《核技术》 CAS CSCD 北大核心 2005年第8期633-636,共4页
利用塑料闪烁体和波长位移光纤搭建了一套宇宙线望远镜系统,该系统具有较大的宇宙线接受立体角,使事例率可达到300/小时。同时该系统具有良好的时间性能,能提供时间分辨为70—90ps的参考时间。在这套望远镜平台上,可以对多气隙电阻性板... 利用塑料闪烁体和波长位移光纤搭建了一套宇宙线望远镜系统,该系统具有较大的宇宙线接受立体角,使事例率可达到300/小时。同时该系统具有良好的时间性能,能提供时间分辨为70—90ps的参考时间。在这套望远镜平台上,可以对多气隙电阻性板室等一些时间探测器的性能进行测量和研究。 展开更多
关键词 波长位移光纤 wlsf 荧光传输时间 参考时间 多气隙电阻性板室 MRPC
在线阅读 下载PDF
波移光纤性能研究
3
作者 吴冲 李杨国骥 +3 位作者 唐彬 孙志嘉 许虹 李家宝 《计量学报》 CSCD 北大核心 2016年第z1期-,共4页
对2种波移光纤的特性进行了研究.实验结果表明,型号为V-11 (200) MS的波移光纤整体性能比BCF-91A波移光纤性能更好.与前者相比,后者在20 mm的弯曲半径下的光传输损耗要高4.8倍.而同时,2个光纤的光衰减长度相当类似,分别为(2.00±0.0... 对2种波移光纤的特性进行了研究.实验结果表明,型号为V-11 (200) MS的波移光纤整体性能比BCF-91A波移光纤性能更好.与前者相比,后者在20 mm的弯曲半径下的光传输损耗要高4.8倍.而同时,2个光纤的光衰减长度相当类似,分别为(2.00±0.02)m和(1.98±0.02)m.此外,Y-11 (200) MS型波移光纤的相对光转换效率比BCF-91A的要高出50%.因此,在制作闪烁体中子探测器时,使用Y-11 (200) MS型波移光纤是一种很好的选择. 展开更多
关键词 计量学 闪烁体中子探测器 6LiF/ZnS(Ag)闪烁体 波移光纤 光衰减长度 弯曲光损耗
在线阅读 下载PDF
Study on temperature response of the HERD calorimeter cell 被引量:2
4
作者 Yingying Dai Xingzhu Cui +5 位作者 Xin Liu Yongwei Dong Hongwei Liang Zhenzhong Zhang Xiaochuan Xia Zhipeng Wei 《Radiation Detection Technology and Methods》 CSCD 2023年第2期227-233,共7页
Purpose To derive the temperature response of the basic unit of the electromagnetic calorimeter of the high energy cosmic-radiation detection(HERD)facility.Method Tested a method to measure HERD calorimeter cell(HCC)l... Purpose To derive the temperature response of the basic unit of the electromagnetic calorimeter of the high energy cosmic-radiation detection(HERD)facility.Method Tested a method to measure HERD calorimeter cell(HCC)light yield using an ultraviolet Light-Emitting Diode with a wavelength of 300 nm,and established an experimental setup and tested the light yield of the HCC at different temperatures in a thermal chamber.Results and conclusions The result showed that the signal amplitudes variation of the HCC reached up to 10.2% with temperature ranging from 0 to 60℃,if we narrow the temperature range to 0-35℃,the variation was about 3.7% and it showed much better linearity.This result provides a good instruction on the thermal control of the HERD calorimeter(CALO)to improve its performance. 展开更多
关键词 HERD LYSO wlsf Optical output Temperature response