AIM:To predict the post-operative vault and the suitable size of the implantable collamer lens(ICL)by comparing the performance of multiple artificial intelligence(AI)algorithms.METHODS:A retrospective analysis of 83 ...AIM:To predict the post-operative vault and the suitable size of the implantable collamer lens(ICL)by comparing the performance of multiple artificial intelligence(AI)algorithms.METHODS:A retrospective analysis of 83 patients with 132 eyes was conducted from 2020 to 2023.All patients underwent implantation of EVO-V4C ICLs.ICLs were selected based on STAAR’s recommended formula.Postoperative vault values were measured using anterior segment optical coherence tomography(ASOCT).First,feature selection was performed on patients’preoperative examination parameters to identify those most closely related to postoperative vault and incorporate them into the machine learning model.Subsequently,four regression models,namely MLP,XGBoost,RFR,and KNN,were employed to predict the vault,and their predictive performances were compared.The ICL size was set as the prediction target,with the vault and other input features serving as new inputs for predicting the ICL size.RESULTS:Among all preoperative parameters,16 parameters were most closely related to postoperative vault and were included in the prediction model.In vault prediction,XGBoost performed the best in the regression model(R^(2)=0.9999),followed by MLP(R^(2)=0.9987)and RFR(R^(2)=0.8982),while the KNN model had the lowest predictive performance(R^(2)=0.3852).XGBoost achieved a prediction accuracy of 99.8%,MLP had a prediction accuracy of 98.9%,while RFR and KNN had accuracies of 87.1%and 57.4%,respectively.CONCLUSION:AI effectively predicts postoperative vault and determines ICL size.XGBoost outperforms other machine-learning algorithms tested.Its accurate predictions help ophthalmologists choose the right ICL size,ensuring proper vaulting.展开更多
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ...AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.展开更多
Analyzing from the perspective of physics mechanics,the pole vault is a project which transforms kinetic energy into elastic potential energy.The magnitude of kinetic energy depends on the vaulter’s approaching speed...Analyzing from the perspective of physics mechanics,the pole vault is a project which transforms kinetic energy into elastic potential energy.The magnitude of kinetic energy depends on the vaulter’s approaching speed,while the magnitude of elastic potential energy depends on height.Therefore,the run-up speed determines the vaulter’s performance in pole vault to a certain extent.the horizontal speed of the pole-holding approach phase transitioning into vertical upward speed plays a crucial role in executing pole vault techniques,and the model of approaching speed establishes a theoretical foundation for vaulters to break through the pole limitation.In terms of specialized technical assistance in speed training,short-distance speed exercises are used in the approaching phase;in the swinging phase,gymnastic rings,single bar and suspension rope exercises are employed for suspension;in the stretch phase,trampoline exercises play a important role in rotation phase,etc.展开更多
The ancient underground cavern of Longyou has a history of more than 2,000 years,and it exhibits a considerable value in archeology,history,science,and culture;therefore,its protection is of considerable significance....The ancient underground cavern of Longyou has a history of more than 2,000 years,and it exhibits a considerable value in archeology,history,science,and culture;therefore,its protection is of considerable significance.Investigating the development mechanism of vault cracks is an important part of the protection work.Most previous studies have been conducted from a single perspective.展开更多
This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are ...This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are bound by a set of random data through the linear function. The number of the function’s variables is determined by the required number of matched minutiae. Then, a new key de- rived from the random data is used to encrypt the cryptographic key. Lastly, the binding data are protected using fuzzy vault scheme. The proposed scheme provides the system with the flexibility to use changeable number of minutiae to bind/recover the protected key and a unified method regardless of the length of the key.展开更多
The wind pressure distribution and wind-induced vibration responses of long-span spatial groined latticed vaults (SGLVs) were numerically simulated, which always are ones of the most important problems in the struct...The wind pressure distribution and wind-induced vibration responses of long-span spatial groined latticed vaults (SGLVs) were numerically simulated, which always are ones of the most important problems in the structural wind resistance design. Incompressible visco-fluid model was introduced, and the standard k - two equation model and semi-implicit method for pressure linked equation (SIMPLE) were used to describe the flow turbulence. Furthermore, the structural dynamic equation was set up, which is solved by Newmark-fl method. And several sort of wind-induced vibration coefficients such as the wind-induced vibration coefficient corresponding to the nodal displacement responses and wind loads were suggested. In the numerical simulation where the SGLV consisting of the cylindrical sectors with different curved surface was chosen as the example, the influence on the relative wind pressure distribution and structural wind-induced vibration responses of the closed or open SGLV caused by such parameters as the number of cylindrical sectors, structural curvature and the ratio of rise to span was investigated. Finally, some useful conclusions on the local wind pressure distribution on the structural surface and the wind-induced vibration coefficients of SGLV were developed.展开更多
Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumu...Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumulating evidence to improve the safety and precision of surgery from common cases to complicated cases in treating cataracts[1-3].Implantable collamer lens(ICL)implantation possesses a good performance in its predictability,reversibility,and the rapid visual recovery.展开更多
AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images we...AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection.展开更多
This study aimed to investigate the difference in gait regulation strategy of pole vault approach runs between successful and failed trials. Five male junior pole vaulters completed full vaulting to 90%-95% personal b...This study aimed to investigate the difference in gait regulation strategy of pole vault approach runs between successful and failed trials. Five male junior pole vaulters completed full vaulting to 90%-95% personal best height. These trials were categorized into successful and failed trials. Step length and the distance from toe to the planting box were obtained using a two dimensional direct linear transformation procedure. In successful trials, standard deviations of the toe-box distance (SDTB) at the last step and take-off of were significantly smaller than those of failed trials (P 〈 0.05). We observed a clear difference in gait regulation strategy between successful and failed trials, thereby suggesting that to minimize the fluctuations of the toe-box distance immediately before the take-off is a key gait regulation strategy for successful pole vault performance.展开更多
Recently, a cryptographic construct,called fuzzy vault, has been proposed for crypto-biometric systems, and some implementations for fingerprint have been reported to protect the stored fingerprint template by hiding ...Recently, a cryptographic construct,called fuzzy vault, has been proposed for crypto-biometric systems, and some implementations for fingerprint have been reported to protect the stored fingerprint template by hiding the fingerprint features. However, all previous studies assumed that fingerprint features were pre-aligned, and automatic alignment in the fuzzy vault domain is a challenging issue.In this paper, an auto-aligned sharing fuzzy fingerprint vault based on a geometric hashing technique is proposed to address automatic alignment in the multiple-control fuzzy vault with a compartmented structure. The vulnerability analysis and experimental results indicate that, compared with original multiplecontrol fuzzy vault, the auto-aligned sharing fuzzy fingerprint vault can improve the security of the system.展开更多
Hysterectomy is common major operation performed in gynecological field practice after Caesarean section. Vaginal hysterectomy is preferred surgery for uterovaginal prolapsed. Vaginal hysterectomy has advantages over ...Hysterectomy is common major operation performed in gynecological field practice after Caesarean section. Vaginal hysterectomy is preferred surgery for uterovaginal prolapsed. Vaginal hysterectomy has advantages over abdominal hysterectomy. Post hysterectomy hematomas are responsible for serious morbidity. Ultrasound is an accurate diagnostic tool and so Computed tomography. Conservative management, analgesia and antibiotics will work in small hematoma, but the significant sized hematoma needs surgical drainage and the infected hematoma. Refinement in surgical techniques is recommended to minimize the formation vaginal vault hematomas after vaginal hysterectomy.展开更多
基金Supported by the National Natural Science Foundation of China(No.82271100)the Jiangsu Science and Technology Support Program(No.BE2022805)the Clinical Skills Enhancement Program of Jiangsu Province Hospital(No.JSPH-MC-2022-24).
文摘AIM:To predict the post-operative vault and the suitable size of the implantable collamer lens(ICL)by comparing the performance of multiple artificial intelligence(AI)algorithms.METHODS:A retrospective analysis of 83 patients with 132 eyes was conducted from 2020 to 2023.All patients underwent implantation of EVO-V4C ICLs.ICLs were selected based on STAAR’s recommended formula.Postoperative vault values were measured using anterior segment optical coherence tomography(ASOCT).First,feature selection was performed on patients’preoperative examination parameters to identify those most closely related to postoperative vault and incorporate them into the machine learning model.Subsequently,four regression models,namely MLP,XGBoost,RFR,and KNN,were employed to predict the vault,and their predictive performances were compared.The ICL size was set as the prediction target,with the vault and other input features serving as new inputs for predicting the ICL size.RESULTS:Among all preoperative parameters,16 parameters were most closely related to postoperative vault and were included in the prediction model.In vault prediction,XGBoost performed the best in the regression model(R^(2)=0.9999),followed by MLP(R^(2)=0.9987)and RFR(R^(2)=0.8982),while the KNN model had the lowest predictive performance(R^(2)=0.3852).XGBoost achieved a prediction accuracy of 99.8%,MLP had a prediction accuracy of 98.9%,while RFR and KNN had accuracies of 87.1%and 57.4%,respectively.CONCLUSION:AI effectively predicts postoperative vault and determines ICL size.XGBoost outperforms other machine-learning algorithms tested.Its accurate predictions help ophthalmologists choose the right ICL size,ensuring proper vaulting.
基金Supported by National Natural Science Foundation of China(No.81900910)Natural Science Foundation of Zhejiang Province(No.LQ19H120003)Basic Scientific Research Project of Wenzhou(No.Y2023809).
文摘AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery.
文摘Analyzing from the perspective of physics mechanics,the pole vault is a project which transforms kinetic energy into elastic potential energy.The magnitude of kinetic energy depends on the vaulter’s approaching speed,while the magnitude of elastic potential energy depends on height.Therefore,the run-up speed determines the vaulter’s performance in pole vault to a certain extent.the horizontal speed of the pole-holding approach phase transitioning into vertical upward speed plays a crucial role in executing pole vault techniques,and the model of approaching speed establishes a theoretical foundation for vaulters to break through the pole limitation.In terms of specialized technical assistance in speed training,short-distance speed exercises are used in the approaching phase;in the swinging phase,gymnastic rings,single bar and suspension rope exercises are employed for suspension;in the stretch phase,trampoline exercises play a important role in rotation phase,etc.
基金the National Natural Science Foundation of China(41672321)Special research project of Shaanxi Provincial Education Department(16JK1489).
文摘The ancient underground cavern of Longyou has a history of more than 2,000 years,and it exhibits a considerable value in archeology,history,science,and culture;therefore,its protection is of considerable significance.Investigating the development mechanism of vault cracks is an important part of the protection work.Most previous studies have been conducted from a single perspective.
基金Supported by the National Natural Science Foundation of China (No.60472069)
文摘This letter proposes fingerprint-based key binding/recovering with fuzzy vault. Fingerprint minutiae data and the cryptographic key are merged together by a multivariable linear function. First, the minutiae data are bound by a set of random data through the linear function. The number of the function’s variables is determined by the required number of matched minutiae. Then, a new key de- rived from the random data is used to encrypt the cryptographic key. Lastly, the binding data are protected using fuzzy vault scheme. The proposed scheme provides the system with the flexibility to use changeable number of minutiae to bind/recover the protected key and a unified method regardless of the length of the key.
基金the Key Project of Fund of Science and Technology Development of Shanghai (No. 07JC14023)the National Natural Science Foundation of China(No. 10572091)
文摘The wind pressure distribution and wind-induced vibration responses of long-span spatial groined latticed vaults (SGLVs) were numerically simulated, which always are ones of the most important problems in the structural wind resistance design. Incompressible visco-fluid model was introduced, and the standard k - two equation model and semi-implicit method for pressure linked equation (SIMPLE) were used to describe the flow turbulence. Furthermore, the structural dynamic equation was set up, which is solved by Newmark-fl method. And several sort of wind-induced vibration coefficients such as the wind-induced vibration coefficient corresponding to the nodal displacement responses and wind loads were suggested. In the numerical simulation where the SGLV consisting of the cylindrical sectors with different curved surface was chosen as the example, the influence on the relative wind pressure distribution and structural wind-induced vibration responses of the closed or open SGLV caused by such parameters as the number of cylindrical sectors, structural curvature and the ratio of rise to span was investigated. Finally, some useful conclusions on the local wind pressure distribution on the structural surface and the wind-induced vibration coefficients of SGLV were developed.
基金Supported by Key Research and Development Program of Shaanxi Province(No.2020SF-271,No.2017SF-273)。
文摘Dear Editor,We are writing this letter to report two unusual cases of femtosecond laser-assisted cataract surgery(FLACS)in two ICL-implanted patients with significant different vault.FLACS has been confirmed by accumulating evidence to improve the safety and precision of surgery from common cases to complicated cases in treating cataracts[1-3].Implantable collamer lens(ICL)implantation possesses a good performance in its predictability,reversibility,and the rapid visual recovery.
文摘AIM:To analyze ultrasound biomicroscopy(UBM)images using random forest network to find new features to make predictions about vault after implantable collamer lens(ICL)implantation.METHODS:A total of 450 UBM images were collected from the Lixiang Eye Hospital to provide the patient’s preoperative parameters as well as the vault of the ICL after implantation.The vault was set as the prediction target,and the input elements were mainly ciliary sulcus shape parameters,which included 6 angular parameters,2 area parameters,and 2 parameters,distance between ciliary sulci,and anterior chamber height.A random forest regression model was applied to predict the vault,with the number of base estimators(n_estimators)of 2000,the maximum tree depth(max_depth)of 17,the number of tree features(max_features)of Auto,and the random state(random_state)of 40.0.RESULTS:Among the parameters selected in this study,the distance between ciliary sulci had a greater importance proportion,reaching 52%before parameter optimization is performed,and other features had less influence,with an importance proportion of about 5%.The importance of the distance between the ciliary sulci increased to 53% after parameter optimization,and the importance of angle 3 and area 1 increased to 5% and 8%respectively,while the importance of the other parameters remained unchanged,and the distance between the ciliary sulci was considered the most important feature.Other features,although they accounted for a relatively small proportion,also had an impact on the vault prediction.After parameter optimization,the best prediction results were obtained,with a predicted mean value of 763.688μm and an actual mean value of 776.9304μm.The R²was 0.4456 and the root mean square error was 201.5166.CONCLUSION:A study based on UBM images using random forest network can be performed for prediction of the vault after ICL implantation and can provide some reference for ICL size selection.
文摘This study aimed to investigate the difference in gait regulation strategy of pole vault approach runs between successful and failed trials. Five male junior pole vaulters completed full vaulting to 90%-95% personal best height. These trials were categorized into successful and failed trials. Step length and the distance from toe to the planting box were obtained using a two dimensional direct linear transformation procedure. In successful trials, standard deviations of the toe-box distance (SDTB) at the last step and take-off of were significantly smaller than those of failed trials (P 〈 0.05). We observed a clear difference in gait regulation strategy between successful and failed trials, thereby suggesting that to minimize the fluctuations of the toe-box distance immediately before the take-off is a key gait regulation strategy for successful pole vault performance.
文摘Recently, a cryptographic construct,called fuzzy vault, has been proposed for crypto-biometric systems, and some implementations for fingerprint have been reported to protect the stored fingerprint template by hiding the fingerprint features. However, all previous studies assumed that fingerprint features were pre-aligned, and automatic alignment in the fuzzy vault domain is a challenging issue.In this paper, an auto-aligned sharing fuzzy fingerprint vault based on a geometric hashing technique is proposed to address automatic alignment in the multiple-control fuzzy vault with a compartmented structure. The vulnerability analysis and experimental results indicate that, compared with original multiplecontrol fuzzy vault, the auto-aligned sharing fuzzy fingerprint vault can improve the security of the system.
文摘Hysterectomy is common major operation performed in gynecological field practice after Caesarean section. Vaginal hysterectomy is preferred surgery for uterovaginal prolapsed. Vaginal hysterectomy has advantages over abdominal hysterectomy. Post hysterectomy hematomas are responsible for serious morbidity. Ultrasound is an accurate diagnostic tool and so Computed tomography. Conservative management, analgesia and antibiotics will work in small hematoma, but the significant sized hematoma needs surgical drainage and the infected hematoma. Refinement in surgical techniques is recommended to minimize the formation vaginal vault hematomas after vaginal hysterectomy.