A digitalizing board for the prototype array of LHAASO WCDA 被引量:5
1
作者 HAO Xinjun LIU Shubin +1 位作者 ZHAO Lei AN Qi 《Nuclear Science and Techniques》 SCIE CAS CSCD 2011年第3期178-184,共7页
In this paper,a digitalizing board for readout of PMT signals in the prototype array of WCDA(water Cerenkov detector array)for LHAASO(Large high altitude air shower observatory)is designed.The prototype array is compo... In this paper,a digitalizing board for readout of PMT signals in the prototype array of WCDA(water Cerenkov detector array)for LHAASO(Large high altitude air shower observatory)is designed.The prototype array is composed of 9 PMTs,including the pulse time and charge measurement from the PMTs,and clock generation and trigger decision.In the digitalizing board,FPGA reconfiguration and data readout via VME bus are implemented.Test results show that the performances meet well with the requirements of readout electronics.It has been installed in Yangbajing and tests with the prototype array and DAQ is ongoing. 展开更多
关键词 PMT Time measurement Charge measurement FPGA reconfiguration vme bus
在线阅读 下载PDF
Study of n-γ discrimination in low energy range(above 40 keVee) by charge comparison method with a BC501A liquid scintillation detector 被引量:4
2
作者 陈永浩 陈熙萌 +8 位作者 张小东 雷家荣 安力 邵剑雄 郑普 王新华 朱传新 何铁 阳剑 《Chinese Physics C》 SCIE CAS CSCD 2014年第3期26-30,共5页
A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was... A VME-based experiment system for n-y discrimination using the charge comparison method was established.A data acquisition program for controlling the programmable modules and processing data online via VME64X bus was developed through the use of Lab VIEW.The two-dimensional(2D) scatter plots of the charge in the slow component vs.the total charge from ^(241)Am-Be and 252Cf neutron sources are presented.The 2D scatter plots of the energy vs.the ratio of the charge in the slow component to the total charge of the pulses are also presented.The quality of n-γ discrimination was checked by the figure-of-merit,and the results showed good performance of n-γ discrimination at the low energy range.Neutrons and γ-rays were separated above 50 keVee(electron-equivalent energy).The quality of n-γ discrimination has been improved compared with others' results at five energies(150,250,350,450,550 keVee). 展开更多
关键词 n-γ discrimination charge comparison method vme bus BC501A liquid scintillation detector low energy range
原文传递