VFPi垂直管流计算在油井压力梯度测试中的应用
1
作者 杜军社 杜佳闻 +1 位作者 熊燕 严臣刚 《油气井测试》 2025年第1期69-72,共4页
PVT取样中存在压力梯度曲线无脱气点或脱气点滞后并高含H_2S气体的一类油井,致使PVT取样深度难以确定。本文以井筒垂直管流理论为基础,应用Eclipse垂直管流VFPi模块作为工具,采用经校正流体关系式以及VFPi模块拟合开展了油井压力梯度和... PVT取样中存在压力梯度曲线无脱气点或脱气点滞后并高含H_2S气体的一类油井,致使PVT取样深度难以确定。本文以井筒垂直管流理论为基础,应用Eclipse垂直管流VFPi模块作为工具,采用经校正流体关系式以及VFPi模块拟合开展了油井压力梯度和流态分析研究。应用结果表明,单相流计算压力与实测压力对比,相对误差小于10%;对于单相流油井,井口附近可作为PVT取样深度;对于多相流油井,以压力梯度变化大的脱气点作为PVT取样深度。该方法可大幅减小设备腐蚀,降低作业成本,加快试油进度。 展开更多
关键词 PVT取样 梯度测试 vfpi 梯度计算 井筒流态 脱气点 取样深度
在线阅读 下载PDF
Seismic behavior of variable frequency pendulum isolator 被引量:6
2
作者 V. R. Panchal R. S. Jangid 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2008年第2期193-205,共13页
Earthquake performance of a flexible one-story building isolated with a variable frequency pendulum isolator (VFPI) under near-fault and far-field ground motions is investigated. The frictional forces mobilized at t... Earthquake performance of a flexible one-story building isolated with a variable frequency pendulum isolator (VFPI) under near-fault and far-field ground motions is investigated. The frictional forces mobilized at the interface of the VFPI are assumed to be velocity dependent. The interaction between frictional forces of the VFPI in two horizontal directions is duly considered and coupled differential equations of motion of the isolated system in the incremental form are solved iteratively. The response of the system with bi-directional interaction is compared with those without interaction. In addition, the effects of velocity dependence on the response of the isolated system are also investigated. Moreover, a parametric study is carried out to critically examine the influence of important parameters on bi-directional interaction effects of the frictional forces of the VFPI. These parameters are: the superstructure time period, frequency variation factor (FVF) and friction coefficient of the VFPI. From the above investigations, it is observed that the dependence of the friction coefficient on relative velocity of the system does not have a noticeable effect on the peak response of the system isolated with VFPI, and that the bi-directional interaction of frictional forces of the VFPI is important and if neglected, isolator displacements will be underestimated and the superstructure acceleration and base shear will be overestimated. 展开更多
关键词 base isolation bi-directional interaction superstructure flexibility near-fault ground motion friction coefficient far-field ground motion vfpi
在线阅读 下载PDF