期刊文献+
共找到401篇文章
< 1 2 21 >
每页显示 20 50 100
Ultrasound Scanning Competencies in Midwifery Education in Zambia: Findings from a Desk Review and Needs Assessment
1
作者 Mutinke Zulu Sebean Mayimbo Patricia Katowa-Mukwato 《Health》 2024年第6期535-552,共18页
Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many wome... Introduction: Ultrasound is an essential component of antenatal care. Midwives provide most of the antenatal care but they do not perform ultrasound as it has been beyond their scope of practice. This leaves many women in Low and Middle-Income Countries without access to ultrasound scanning. The aim of this study was to identify competencies in ultrasound scanning in midwifery education. Methods: A desk review and needs assessment were conducted between July and October 2023. Articles and curricula on the internet, Google scholar and PubMed were searched for content on ultrasound scanning competencies. A Google form consisting of 20 questions was administered via email and WhatsApp to 135 participants. Descriptive statistics were used to analyse data. Results: The desk review showed that it is feasible to train midwives in ultrasound scanning. The training programs for midwives in obstetric ultrasound were conducted for 1 week to 3 months with most of them running for 4 weeks. Content included introduction to general principles of ultrasound, physics, basic knowledge in embryology, obstetrics, anatomy, measuring foetal biometry, estimating amniotic fluid and gestational age. Experts like sonographers trained midwives. Theory and hands on were the teaching methods used. Written and practical assessments were conducted. Needs assessment revealed that majority of participants 71 (53%) knew about basic ultrasound training for midwives. All participants (100%) said it is necessary to train midwives in basic ultrasound scan in Zambia. Some content should include, anatomy, measuring foetal biometry, assessing amniotic fluid level, and gestational age determination. Most participants 91 (67%) suggested that the appropriate duration of training is 4 - 6 weeks. Conclusion: Empowering every midwife with ultrasound scanning skills will enable early detection of any abnormality among pregnant women and prompt intervention to save lives. 展开更多
关键词 ultrasound scanning Midwifery Education Competencies
在线阅读 下载PDF
Cubic spline interpolation based ultrasound scan conversion algorithm 被引量:1
2
作者 MA Li-yong SUN Yu-de SHEN Yi 《通讯和计算机(中英文版)》 2008年第5期7-11,共5页
关键词 朝声扫描 转换算法 三次样条 内插技术
在线阅读 下载PDF
Assessing gestational age of babies: Performance of obstetric ultrasound scan compared to that from the combination of Naegle’s rule and Dubowitz score in the 21st century
3
作者 Baba Usman Ahmadu 《Natural Science》 2013年第8期32-35,共4页
Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is st... Background: Some researchers have suggested that when Naegle’s rule (NR) and Dubowitz score (DS) are combined, it could out-perform obstetric ultrasound scan (USS). Others still believe that obstetric USS alone is still effective relative to the combination of NR rule and DS in assessing the gestational age (GA) of babies. Objectives: To determine and compare the GA of babies using obstetric USS, NR and DS;and to provide relevant public health information on obstetric USS in the 21st century. Methods: Subjects were selected using systematic random sampling and the GA of babies was determined using obstetric USS, NR, and DS. Statistical package for social science (SPSS) statistical software version 16, Illinois, Chicago USA was used for all data analysis. Results: Eightyfive mother-baby pairs were studied. Forty-four babies (52%) were males and 41 (48%) females. Sixty four (75%) were term with a mean (SD) BW of 3.02 (0.59) at 95%CI (2.89 -?3.14) kg. The overall mean GA of the babies was 38.49 (2.89) at 95%CI (38.14 -?38.85) weeks. The mean GA using obstetric USS, NR and DS were 38.52 (1.98) at 95%CI (38.14 -?38.99), 38.09 (4.13) at 95%CI (37.20-?38.99) and 38.82 (2.02) at 95%CI (38.39 -?39.26), but comparison of these means was not significant (p = 0.256). Combined mean GA by NR and DS was 38.46 (3.26) at 95%CI (37.96 -?38.95). Comparing this mean with mean GA obtained by obstetric USS was also not significant (p = 0.885). Conclusion: The GA assessments by Obstetric USS, NR and DS were all reliable, and Obstetric USS performed effectively relative to combined NR and DS. 展开更多
关键词 GESTATIONAL Age Babies OBSTETRIC ultrasound scan Naegle’s RULE Dubowitz SCORE Maiduguri NIGERIA
暂未订购
Fazari’s Sign in Ultrasound Scan of Morbid Adherent Placenta/Placenta Accreta Spectrum (MAP/PAS) and Fazari’s Triad during (MAP/PAS) Surgery
4
作者 Atif Bashir Eltayeb Fazari Zeinabsadat Tabatabaei Hakim 《Open Journal of Obstetrics and Gynecology》 2020年第4期599-603,共5页
Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow ... Morbid Adherent Placenta (MAP)/Placenta Accreta Spectrum (PAS) is a serious diagnosis which has a risk of complications. Ultrasound scan helps in early diagnosis and has great value in further confirmation and follow up. Observed new clinical sign and associated clinical triad are discussed here. 展开更多
关键词 MORBID Adherent PLACENTA (MAP)/Placenta Accreta Spectrum (PAS) ultrasound scan Stair Step SIGN Fazari’s TRIAD
暂未订购
B-scan ultrasound and cytology of the vitreous in primary central nervous system lymphoma with vitreoretinal involvement 被引量:5
5
作者 Jie Lai Kun Chen +6 位作者 Hui-Min Shi Lin Zhuang Xian Zhou Jian-Jiang Xiao Yi Li Bo-Bin Chen Qing-Ping Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第6期1001-1007,共7页
AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clini... AIM: To evaluate the diagnostic value of B-scan ultrasound and explore the cytological characteristics of patients with vitreoretinal lymphoma(VRL) and primary central nervous system lymphoma(PCNSL).METHODS: The clinical data and pathologic specimens from patients with VRL diagnosed at the North Huashan Hospital from 2016 to 2017 were retrospectively reviewed. The patients were diagnosed by slit lamp ophthalmoscopy, B-scan ultrasound, cytology of the vitreous, which was obtained by vitrectomy, and cytokine measurements of interleukin(IL)-10 and IL-6.RESULTS: Twenty-six eyes(19.4%) out of 134 eyes of 67 patients(47 men and 20 women) with PCNSL were diagnosed with VRL by B-scan ultrasound, and 14 eyes(10.4%) were diagnosed by slit lamp ophthalmoscopy. Twenty-four eyes(17.9%) of 17 patients were confirmed as having VRL with cytology. No difference in the association between intracranial lesion location and ocular involvement was found. VRL patients had higher levels of vitreous IL-10 and IL-10/IL-6 when compared with macular hole cases, but the difference was not statistically significant.CONCLUSION: A total of 25.4% of the PCNSL patients had VRL, B-scan ultrasound examination had characteristic features and is recommended over slit lamp ophthalmoscopy for the screening diagnosis of PCNSL with intraocular involvement. Moreover, the cytological and immunohistochemical analyses performed after 25-gauge diagnostic vitrectomy were accurate diagnostic techniques. 展开更多
关键词 primary central nervous LYMPHOMA INTRAOCULAR LYMPHOMA B-scan ultrasound VITRECTOMY INTERLEUKIN-10
原文传递
Progress of research in the application of ultrasound technology for the treatment of Alzheimer’s disease
6
作者 Qiuquan Cai Lianghui Meng +5 位作者 Meina Quan Ling Wang Jing Ren Chenguang Zheng Jiajia Yang Dong Ming 《Neural Regeneration Research》 SCIE CAS 2025年第10期2823-2837,共15页
Alzheimer’s disease is a common neurodegenerative disorder defined by decreased reasoning abilities,memory loss,and cognitive deterioration.The presence of the blood-brain barrier presents a major obstacle to the dev... Alzheimer’s disease is a common neurodegenerative disorder defined by decreased reasoning abilities,memory loss,and cognitive deterioration.The presence of the blood-brain barrier presents a major obstacle to the development of effective drug therapies for Alzheimer’s disease.The use of ultrasound as a novel physical modulation approach has garnered widespread attention in recent years.As a safe and feasible therapeutic and drug-delivery method,ultrasound has shown promise in improving cognitive deficits.This article provides a summary of the application of ultrasound technology for treating Alzheimer’s disease over the past 5 years,including standalone ultrasound treatment,ultrasound combined with microbubbles or drug therapy,and magnetic resonance imaging-guided focused ultrasound therapy.Emphasis is placed on the benefits of introducing these treatment methods and their potential mechanisms.We found that several ultrasound methods can open the blood-brain barrier and effectively alleviate amyloid-βplaque deposition.We believe that ultrasound is an effective therapy for Alzheimer’s disease,and this review provides a theoretical basis for future ultrasound treatment methods. 展开更多
关键词 Alzheimer’s disease blood-brain barrier DRUGS magnetic resonance imaging-guided focused ultrasound MICROBUBBLES scanning ultrasound ultrasound ultrasound stimulation
暂未订购
Development of a High-frequency Ultrasound System for High-speed Image Scanning 被引量:1
7
作者 WU Jian-xing CHEN Pei-zhan +2 位作者 WANG Jian-lin CHEN Guan-chun CHEN Tai-song 《Chinese Journal of Biomedical Engineering(English Edition)》 2013年第2期79-85,92,共8页
High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound ... High-frequency image technique has been widely applied in medical diagnosis recently. For high voltage protection, high speed stage and trigger control circuitry are difficult to implement a high-frequency ultrasound imaging system. In this study, we utilized a linear servo with high noise tolerance and a novel multi-depth expression method to overcome those issues in developed high-speed image system. B-mode image of the chicken phantom by 25 MHz transducer shows the resolution of lateral and axial resolutions are up to 123 μm and 59 μm respectively. In addition, the experiment demonstrates that the axial resolution and depth of field (DOF) can be improved by time gain compensation(TGC) and multi-depth method. The results indicate that the proposed system could achieve over 24 fps for 1 mm scan distance and 100 lines per frame. In the future, the developed system is potential for other clinical applications such as ophthalmology and dermatology. 展开更多
关键词 high-frequency ultrasound time gain compensation (TGC) multi-focus scan
暂未订购
AL-Scan、IOL-Master和A超测量白内障患者眼轴长度的准确性和一致性分析 被引量:11
8
作者 孙飒 郭海科 《眼科新进展》 CAS 北大核心 2016年第9期876-878,共3页
目的比较AL-Scan、IOL-Master和A超测量白内障患者眼轴长度(axial length,AL)的准确性和一致性。方法选取年龄相关性白内障患者95例(142眼),术前分别应用AL-Scan、IOL-Master和A超进行AL测量。根据AL将患者分为AL≤22 mm(20眼)、22mm<... 目的比较AL-Scan、IOL-Master和A超测量白内障患者眼轴长度(axial length,AL)的准确性和一致性。方法选取年龄相关性白内障患者95例(142眼),术前分别应用AL-Scan、IOL-Master和A超进行AL测量。根据AL将患者分为AL≤22 mm(20眼)、22mm<AL≤26 mm(98眼)和AL>26 mm(24眼)3组。应用方差分析对3种方法测量的结果进行比较,应用Bland-Altman法对其一致性进行分析。结果 AL≤22 mm组AL-Scan、IOL-Master和A超测得AL结果分别为(21.53±0.30)mm、(21.54±0.29)mm及(21.51±0.30)mm,差异无统计学意义(P>0.05);22 mm<AL≤26 mm组分别为(23.68±0.76)mm、(23.71±0.77)mm及(23.65±0.75)mm,差异无统计学意义(P>0.05);AL>26 mm组分别为(28.46±1.60)mm、(28.50±1.62)mm及(28.40±1.63)mm,差异无统计学意义(P>0.05)。AL测量的95%一致性界限范围是0.20 mm(AL-Scan和IOL-Master)、1.12 mm(IOLMaster和A超)和1.12 mm(AL-Scan和A超)。结论 AL-Scan、IOL-Master和A超测量白内障患者AL同样准确,但AL-Scan与IOL-Master之间具有良好的一致性。 展开更多
关键词 眼轴长度 AL—scan IOL—Master A超
暂未订购
Ultrasound Diagnosis of Primary Epiploic Appendagitis: A Case Report 被引量:1
9
作者 Sylviane Dongmo Joshua Tambe +3 位作者 Yannick Onana Ngwane Ntongwetape Elroy Weledji Emilienne Guegang 《Open Journal of Medical Imaging》 2023年第1期1-10,共10页
A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging m... A rare differential diagnosis for severe abdominal pain is acute epiploic appendagitis. Its symptoms resemble those of acute diverticulitis, acute appendicitis, or omental infarction quite a bit. The primary imaging method used for diagnosis is computed tomography (CT). We are describing the case of a 27-year-old guy who underwent an abdominal ultrasonography after complaining of severe left lower quadrant abdominal pain. It identified an oval and non-compressible hyperechoic mass in the left iliac fossa. The mass was surrounded by a hypoechoic rim and there was no color Doppler signal. In the absence of CT, radiologists must be able to diagnose acute epiploic appendagitis on ultrasound in order to avoid unnecessary hospital admission, pricey laboratory tests, antibiotic treatment, and unnecessary surgery. In this instance, the patient was spared from ionization exposure from a potential CT scan and other invasive treatments including surgery with associated costs because of the reliable ultrasound diagnosis of epiploic appendagitis. After receiving conservative medical treatment, the patient was placed under surveillance and then discharged. 展开更多
关键词 Acute Abdominal Pain Epiploic Appendagitis ultrasound scan
暂未订购
The ultrasound diagnosis of fetal gastric teratoma
10
作者 Lixue Zhou Ruike Pan Xin Zhang Lirong He 《The Chinese-German Journal of Clinical Oncology》 CAS 2010年第11期666-668,共3页
Objective: The aim of the study was to discuss the value of ultrasound examination in the diagnosis of fetal gastric teratoma. Methods: We retrospectively analyzed 2 cases with fetal gastric teratoma in our hospital (... Objective: The aim of the study was to discuss the value of ultrasound examination in the diagnosis of fetal gastric teratoma. Methods: We retrospectively analyzed 2 cases with fetal gastric teratoma in our hospital (Department of Gynecology and Obstetrics, Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China). It involved clinical, ultrasonic, X-ray, CT and MRI, biochemical, pathological, karyotype and immunohistochemical data. Results: There both were hybrid echo masses in the abdominal of the fetus with the sonography and the ultrasound features which mostly like the teratomas. Two cases were dead after induced abortion. The pathological results of the mass were gastric immature teratoma in one, and stomach mature teratoma in another. Conclusion: Fetal gastric teratoma is rarely seen and easily be misdiagnosed in clinic. The diagnosis depends finally on pathological examination. Ultrasound scan as the easy and direct method is helpful to clew the diagnosis of fetal gastric teratoma. 展开更多
关键词 fetal gastric teratoma ultrasound scan PATHOLOGY
在线阅读 下载PDF
超声波辅助乙醇浸提小米糠脱脂工艺优化
11
作者 尹玉鑫 刘恒洋 +2 位作者 郭晓徐 宋绍奇 刘美玉 《食品研究与开发》 2026年第1期109-116,共8页
为提高小米糠的综合利用率、减少资源浪费,以新鲜小米糠为原料,95%乙醇为脱脂剂,采用超声波辅助浸提法对小米糠脱脂,以脱脂率为判断指标,在单因素试验的基础上,采用响应面法优化小米糠脱脂工艺。结果表明:小米糠脱脂工艺的最佳组合为料... 为提高小米糠的综合利用率、减少资源浪费,以新鲜小米糠为原料,95%乙醇为脱脂剂,采用超声波辅助浸提法对小米糠脱脂,以脱脂率为判断指标,在单因素试验的基础上,采用响应面法优化小米糠脱脂工艺。结果表明:小米糠脱脂工艺的最佳组合为料液比1∶17(g/mL)、超声时间15 min、超声功率600 W、超声温度55℃,在此条件下,脱脂率达到95.32%,与模型预测值94.31%相对误差仅为1.07%;脱脂后,小米糠中的脂肪含量由13.37%降至0.63%,保留了蛋白质、膳食纤维;扫描电子显微镜分析发现脱脂处理后小米糠不易聚集,粉体更加细致均匀,进一步提升了小米糠的利用价值。 展开更多
关键词 小米糠 脱脂 超声波 乙醇浸提 扫描电子显微镜
在线阅读 下载PDF
IOL Master和A-scan在白内障合并黄斑病变中的应用比较 被引量:3
12
作者 唐丽 秦明敏 +3 位作者 张甦炯 叶常虹 夏媛玲 陈炜 《贵州医科大学学报》 CAS 2020年第9期1061-1066,共6页
目的:比较光学相干生物测量仪(IOL Master)和A型超声测量(A-scan)在白内障合并黄斑病变眼轴测量和人工晶体测算的准确性及术后屈光状态的评价。方法:选取白内障合并黄斑病变需行超声乳化吸出并人工晶体植入术患者38例(46只眼),分别于术... 目的:比较光学相干生物测量仪(IOL Master)和A型超声测量(A-scan)在白内障合并黄斑病变眼轴测量和人工晶体测算的准确性及术后屈光状态的评价。方法:选取白内障合并黄斑病变需行超声乳化吸出并人工晶体植入术患者38例(46只眼),分别于术前和术后3个月检查术眼的视力并比较;术前采用光学相干断层扫描(OCT)检查术眼视网膜中央厚度(CRT);术前分别用IOL Master和A-scan测量术眼的眼轴长度(AL),根据AL选择人工晶体计算公式SRK-T或Haigis公式确定植入人工晶体(IOL)的度数、目标屈光度及预留的屈光度数并比较;采用Bland-Altman法分析2种测量方法的一致性,采用Pearson相关分析2种方法AL差值与CRT的相关性;比较2种测量方法预留屈光度数、术后3个月验光的绝对屈光误差(AE)及屈光漂移类型的差异。结果:患者术眼术后3个月裸眼视力较术前提高(P<0.05);Bland-Altman分析结果显示,2种测量方法AL差值的95%医学参考范围为-0.77~0.89 mm,其中最大差值的绝对值为0.45 mm;2种测量方法AL的差异无统计学意义(Z=-1.778,P=0.075),且AL的差值与CRT无相关性(r=0.087,P=0.564);IOL Master方法术后3个月AE值较A-scan更接近于0 D(P<0.001);2种测量方法术后3个月屈光漂移均以近视漂移为主,且近视漂移检出和AE介于0.00~1.00 D的比例均表现为测量方法IOL Master>A-scan(P<0.01)。结论:IOL Master和A-scan在测量白内障合并黄斑病变患者的AL上一致性好,与CRT无相关性;术后2种测量方法的屈光漂移均表现为近视漂移为主,且IOL Master准确性优于A-scan。 展开更多
关键词 白内障 黄斑病变 光学相干生物测量仪 A型超声 眼轴 中央视网膜厚度
暂未订购
AL-Scan与A型超声测量老年性白内障患者眼轴长度与前房深度的对比研究 被引量:2
13
作者 李丹 《临床眼科杂志》 2017年第5期428-430,共3页
目的比较AL-Scan与A型超声测量的眼轴长度(AL)及前房深度(ACD)的结果,验证AL-Scan的准确性及其临床应用价值。方法对白内障患者依次行AL-Scan与A型超声测量AL与ACD,比较两者的差异,数据进行统计分析。结果 AL-Scan测量的AL为(24.55±... 目的比较AL-Scan与A型超声测量的眼轴长度(AL)及前房深度(ACD)的结果,验证AL-Scan的准确性及其临床应用价值。方法对白内障患者依次行AL-Scan与A型超声测量AL与ACD,比较两者的差异,数据进行统计分析。结果 AL-Scan测量的AL为(24.55±0.85)mm,A型超声测量的AL为(24.52±0.89)mm,两者的差异无统计学意义(t=0.463,P>0.05)。AL-Scan测量的ACD为(2.67±0.49 mm),A型超声测量的ACD为(2.61±0.53)mm,两者的差异无统计学意义(t=0.753,P>0.05)。结论 AL-Scan是一种在临床应用中准确性较高的生物学测量仪器,可用于眼轴及前房深度的测量。 展开更多
关键词 AL-scan A型超声 眼轴长度 前房深度
暂未订购
Evaluation of immersion 20 MHz B-scan ultrasonography in observing lens in the alkali burn eyes 被引量:2
14
作者 Qing-Hua Yang Bing Chen +3 位作者 Li-Qiang Wang Guang-Hua Peng Zhao-Hui Li Yi-Fei Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第4期632-637,共6页
·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was ... ·AIM: To evaluate the accuracy of 20 MHz immersion Bscan ultrasonography in observing lens and to investigate the value of this noninvasive preoperative diagnosis method in alkali burn eyes.·METHODS: It was a comparative study. Fifty-six cases(56 eyes) of alkali burn eyes were examined by ultrasound biomicroscopy(UBM) and immersion 20 MHz B-scan ultrasonography from June 2011 to April 2013,the images were analyzed, and the ultrasonographic diagnosis compared with the operation results.·RESULTS: In 56 alkali burn eyes examined by UBM, the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; the anterior lens capsule surface or/and the front lens could be detected in 18 eyes, and lens opacification in 3 eyes of them; suspected abnormal lens were detected in the other 20 eyes. In all the same eyes examined by immersion 20 MHz B-scan ultrasonography,the lens were not detected in 16 eyes; the IOL could be detected in 2 eyes; 24 abnormal lens(opacity, lens expansion, shrinkage) and 14 normal lens were found.Compared with the intraoperative findings, the diagnostic accordance rate of the immersion 20 MHz B-scan appearance of lens was 100%(56/56), which was significantly higher than examined by UBM 57.14%(32/56)(χ2=30.55, P =0.0000).·CONCLUSION: Immersion 20 MHz B-scan ultrasonography can observe the lens accurately in alkali burn eyes. It has important clinical value to combine with UBM in eyes of alkali burn. 展开更多
关键词 IMMERSION B-scan ULTRASONOGRAPHY alkali burn ultrasound biomicroscopy
原文传递
Diagnostic Ultrasound and Pars Plana Vitrectomy in Endophthalmitis
15
作者 JingjingHuang ZhenfangWang LijuanZou XiaofengLin YiwenLuo ZhaohuiYuan 《眼科学报(英文版)》 CAS 2004年第3期149-154,共6页
Purpose: To compare the results by B-scan ultrasonography and findings in pars plana vitrectomy, and assess the diagnostic value of B-scan ultrasonography in endophthalmitis.Methods: Thirty eyes of 30 subjects diagnos... Purpose: To compare the results by B-scan ultrasonography and findings in pars plana vitrectomy, and assess the diagnostic value of B-scan ultrasonography in endophthalmitis.Methods: Thirty eyes of 30 subjects diagnosed as endophthalmitis were selected, who undergone preoperative B-scan ultrasonography. The result of pars plana vitrectomy was recorded. The above two results were compared.Results: On the evaluation of vitreous and retinal states in the patients with endophthal-mitis, the sensitivity of ultrasound was 90%~100%, and the specificity was 79%~100%. Poorer preoperative visual acuity was related with retinal detachment and retinal dissolution. The preoperative visual acuity in eyes with local vitreous opacity was better than with diffuse vitreous opacity.Conclusion: Comparison of the results of B-scan ultrasonography and the findings in pars plana vitrectomy showed B-scan ultrasonography is highly sensitive,specific, and is very helpful in the evaluation of endophthalmitis. B-scan ultrasonography can not only supply much information in the diagnosis of endophthalmitis but also inspect its trends and changes, which is helpful in the selection of treatment and planning the time of surgery. 展开更多
关键词 超声诊断法 睫状环 玻璃体切开术 眼内炎 灵敏度
暂未订购
Accuracy of crescent sign on ocular ultrasound in diagnosing papilledema 被引量:1
16
作者 Ananth Bhosale Virna M Shah Parag K Shah 《World Journal of Methodology》 2017年第3期108-111,共4页
AIM To study the usefulness of orbital ultrasonography in the diagnosis of papilledema.METHODS Fifty patients who were referred to the neurophthalmology clinic and clinically suspected to have papilledema were selecte... AIM To study the usefulness of orbital ultrasonography in the diagnosis of papilledema.METHODS Fifty patients who were referred to the neurophthalmology clinic and clinically suspected to have papilledema were selected. Thorough, clinical examination with slitlamp biomicroscopy and visual acuity assessment was done. These patients underwent ultrasonography to demonstrate the crescent sign. The patients were further evaluated with the neurologist and magnetic resonance imaging(MRI) thus confirming the diagnosis of papilledema. The results of our ultrasonographic evaluation were correlated with final diagnosis after thorough clinical evaluation, imaging and the neurologist's opinion.RESULTS Out of 50 patients diagnosed having papilledema on MRI, 46(92%) showed crescent sign on B scan ultrasonography. Headache was most common presenting complaint in 47(94%) and idiopathic intracranial hypertension was most common underlying cause of papilledema in 30(60%) cases.CONCLUSION"Crescent sign" seen on ultrasonography is a sensitive tool for diagnosis of papilledema. It is cost effective, less cumbersome and effective tool to differentiatebetween papilledema and pseudo papilledema before subjecting the patients to costly investigations like MRI. A positive crescent sign should always be followed by MRI to find out the cause of papilledema. 展开更多
关键词 PAPILLEDEMA Orbital ultrasound Doughnut sign Crescent sign B scan
在线阅读 下载PDF
Additional Imaging Following a Negative Sestamibi Scan in Primary Hyperparathyroidism
17
作者 Bas Twigt Anne Vollebregt +2 位作者 Piet de Hooge Alex Muller Thijs van Dalen 《International Journal of Otolaryngology and Head & Neck Surgery》 2012年第3期93-98,共6页
Background: The objective of this study was to assess the additional yield of US and CT following a “negative” initial MIBI-scintigraphy (MIBI) in patients with primary hyperparathyroidism. Methods: Prospective data... Background: The objective of this study was to assess the additional yield of US and CT following a “negative” initial MIBI-scintigraphy (MIBI) in patients with primary hyperparathyroidism. Methods: Prospective data were collected regarding 100 consecutive patients, preferentially undergoing a minimally invasive parathyroidectomy (MIP). MIBI was the initial imaging study for localizing a solitary adenoma, followed by US and CT (US/CT) in “MIBI-negative”-patients. Results: Surgery led to normocalcemia in 98 patients (98%) after one operation. Overall 97 patients had solitary parathyroid disease while three patients had multiglandular disease. The sensitivity of imaging increased from 74% for MIBI alone to 92% following subsequent US/CT in “MIBI-negative”-patients. The positive predictive value of a “positive” MIBI was 96% and 76% of a positive US/CT following negative MIBI. The proportion of patients who underwent successful MIP increased from 60 to 72%. Conclusions: MIBI and the combination of US and CT are complementary imaging studies. Additional localization studies after a negative sestamibi scan enhances the number of patients with primary hyperparathyroidism profiting from a minimally invasive approach. 展开更多
关键词 Imaging-Primary Hyperparathyroidism-Sestamibi scan-ultrasound-CT
暂未订购
检测声学成像原理与技术综述 被引量:1
18
作者 张楠 许才彬 邓明晰 《应用声学》 北大核心 2025年第1期13-35,共23页
声学成像是现代检测领域当中的一门常用的技术。它利用超声波强大的穿透能力获取反映被测区域内部结构和物理性质的声学信息,能够提供直观的结构二维或三维图像,从而为医学诊断、工业无损检测和水下探测等方面的研究和应用提供依据。该... 声学成像是现代检测领域当中的一门常用的技术。它利用超声波强大的穿透能力获取反映被测区域内部结构和物理性质的声学信息,能够提供直观的结构二维或三维图像,从而为医学诊断、工业无损检测和水下探测等方面的研究和应用提供依据。该文从成像结果的维度出发,通过将现有的检测声学成像方法划分二维厚度截面成像、二维水平截面成像和三维成像三种类型,对包含扫描成像、相控阵成像、合成孔径聚焦成像和超声层析成像在内的各方法的原理和技术特点进行了综述,阐述了这些方法的具体实施过程,并归纳了其优缺点。最后综合分析了影响这些方法准确性、实时性和经济性的主要因素,并给出了相应的应对策略。 展开更多
关键词 超声检测 声学成像 扫描成像 相控阵 超声层析成像
在线阅读 下载PDF
乳腺三维全容积自动扫描技术联合超声及超声弹性成像检查诊断乳腺肿块良恶性的临床价值
19
作者 李惠玲 吴意赟 +2 位作者 许华宁 居艳妍 蔡婷 《医学影像学杂志》 2025年第8期83-87,共5页
目的 探讨乳腺三维全容积自动扫描(ABVS)技术联合常规超声(US)及超声弹性成像(UE)检查诊断乳腺肿块良恶性的临床价值。方法 选取140例乳腺肿块患者,经病理检查确诊恶性肿块68例(恶性肿块组)、良性肿块72例(良性肿块组)。于病理检查前行A... 目的 探讨乳腺三维全容积自动扫描(ABVS)技术联合常规超声(US)及超声弹性成像(UE)检查诊断乳腺肿块良恶性的临床价值。方法 选取140例乳腺肿块患者,经病理检查确诊恶性肿块68例(恶性肿块组)、良性肿块72例(良性肿块组)。于病理检查前行ABVS、US及UE检查,比较两组ABVS、US声像图特征及UE评分;以病理检查结果为金标准,采用四格表法计算ABVS、US、UE及三项联合诊断乳腺恶性肿块的阳性预测值、阴性预测值;绘制受试者工作特征(ROC)曲线,分析ABVS、US、UE及三项联合对乳腺恶性肿块的诊断效能。结果 恶性肿块组的钙化、后方回声衰减、纵横比≥1及血流信号Ⅱ、Ⅲ级占比均高于良性肿块组,差异有统计学意义(P<0.05)。恶性肿块组的汇聚征、虫蚀样、微钙化占比及UE评分均高于良性肿块组,差异有统计学意义(P<0.05)。以病理检查结果为金标准,ABVS检查的阳性和阴性预测值分别为81.54%、80.00%;US检查的阳性和阴性预测值分别为63.49%、63.64%;UE检查的阳性和阴性预测值分别为83.33%、82.43%;三项联合检查的阳性和阴性预测值分别为92.54%、91.78%。三项联合诊断准确率分别高于ABVS、US、UE单独检查,差异有统计学意义(P<0.05)。ROC曲线分析显示,ABVS、US、UE及三项联合诊断乳腺恶性肿块的曲线下面积(AUC)值分别为0.801、0.618、0.827及0.926,三项联合高于单独检查,差异有统计学意义(P<0.05)。结论 ABVS、US及UE三项联合鉴别诊断乳腺肿块良恶性的效能较高,有利于提高诊断准确率。 展开更多
关键词 乳腺肿块 三维全容积自动扫描技术 超声检查 超声弹性成像
暂未订购
多模态超声在BI-RADS 4类乳腺病变鉴别诊断中的应用价值
20
作者 李亚楠 黄国喜 马玉璐 《罕少疾病杂志》 2025年第12期75-77,81,共4页
目的评估多模态超声在BI-RADS 4类乳腺病变良恶性鉴别诊断中的应用价值,旨在探索其提升诊断特异性、优化临床决策的潜能。方法择取我院2022年1月至2022年12月收治的196例BI-RADS 4类乳腺结节患者(198个结节)临床资料进行回顾性分析,以... 目的评估多模态超声在BI-RADS 4类乳腺病变良恶性鉴别诊断中的应用价值,旨在探索其提升诊断特异性、优化临床决策的潜能。方法择取我院2022年1月至2022年12月收治的196例BI-RADS 4类乳腺结节患者(198个结节)临床资料进行回顾性分析,以手术病理学诊断为金标准,构建受试者工作特征曲线(ROC曲线),比较不同检查方式单一诊断及联合诊断效能。结果手术病理学结果:196例BI-RADS 4类乳腺结节患者中有62个恶性结节和136个良性结节;多模态超声诊断特异度97.1%、灵敏度88.7%、准确率94.4%、阳性预测值93.2%、阴性预测值94.9%均较2DUS、CEUS、UE、ABVS诊断效能高(P<0.05)。结论多模态超声通过整合形态学、组织弹性及微血管功能信息,实现从不同病理生理机制层面对BI-RADS 4类乳腺病变进行综合解析,其诊断效能的显著提升具有坚实的理论依据与实践验证。 展开更多
关键词 多模态超声 BI-RADS 4类乳腺病变 常规二维超声 超声造影 超声弹性成像 自动乳腺容积扫描 鉴别诊断 诊断效能
暂未订购
上一页 1 2 21 下一页 到第
使用帮助 返回顶部