制备了负载在Na Y分子筛上的Fe Cu Mn Y复合催化剂,并对其在非均相UV Fe Cu Mn Y H2O2体系中催化氧化4BS染料废水进行了研究.结果表明,非均相UV Fe Cu Mn Y H2O2体系对4BS染料废水的处理具有很高的效率.在基准条件下,反应时间为20min时...制备了负载在Na Y分子筛上的Fe Cu Mn Y复合催化剂,并对其在非均相UV Fe Cu Mn Y H2O2体系中催化氧化4BS染料废水进行了研究.结果表明,非均相UV Fe Cu Mn Y H2O2体系对4BS染料废水的处理具有很高的效率.在基准条件下,反应时间为20min时,废水中4BS的去除率达到了93 7%.与均相UV Fenton体系不同,非均相UV Fe Cu Mn Y H2O2体系在碱性条件下(pH=10 5)仍可高效去除CODCr.动力学研究得到催化氧化4BS废水的模型方程,该模型可以为非均相UV Fe Cu Mn Y H2O2体系处理高色度的实际染料废水提供指导.展开更多
A novel coordination polymer, [Fe(C 5H 4NCOO) 2] n, was synthesized by hydrothermal reaction and characterized by elemental analysis as well as IR spectroscopy. The crystal structure (with a novel 3-D network) of this...A novel coordination polymer, [Fe(C 5H 4NCOO) 2] n, was synthesized by hydrothermal reaction and characterized by elemental analysis as well as IR spectroscopy. The crystal structure (with a novel 3-D network) of this compound belongs to monoclinic, space group P2 1/n, a=0.49544(1) nm, b=1.32443(2) nm, c=1.04983(1) nm, β=101.586(1)°. The diffuse reflectance spectra (200~2500 nm) showed that the polymer had strong absorbance in 375~563 nm (E g≈2.5 eV) region and weak absorbance from 720 to 2500 nm (near infrared spectra).展开更多
为去除废水中的焦糖色素,采用H2O2/Fe2+和H2O2/Fe2+/UV对焦糖色素去除进行研究.实验考察了H2O2和Fe2+投加量、pH值、反应时间对焦糖色素去除率的影响,在此基础上进一步考察了H2O2/Fe2+/UV对焦糖色素去除效果.结果表明,对于芬顿试剂,H2O2...为去除废水中的焦糖色素,采用H2O2/Fe2+和H2O2/Fe2+/UV对焦糖色素去除进行研究.实验考察了H2O2和Fe2+投加量、pH值、反应时间对焦糖色素去除率的影响,在此基础上进一步考察了H2O2/Fe2+/UV对焦糖色素去除效果.结果表明,对于芬顿试剂,H2O2与Fe2+反应的化学计量数为8;pH值为3,反应时间30 m in时,焦糖色的去除效果较好,去除率达到83%.采用H2O2/Fe2+/UV可进一步提高焦糖色的去除效果,去除率可提高到90%.因此采用H2O2/Fe2+或H2O2/Fe2+/UV法获得良好的焦糖色去除效果.展开更多
The degradation of atrazine (ATZ),sulfamethoxazole (SMX) and metoprolol (MET) in flowthrough VUV/UV/H2O2reactors was investigated with a focus on the effects of H2O2dosage and reactor internal diameter (ID).Results sh...The degradation of atrazine (ATZ),sulfamethoxazole (SMX) and metoprolol (MET) in flowthrough VUV/UV/H2O2reactors was investigated with a focus on the effects of H2O2dosage and reactor internal diameter (ID).Results showed that the micropollutants were degraded efficiently in the flow-through VUV/UV/H2O2reactors following the pseudo first-order kinetics (R2>0.92).However,the steady-state assumption (SSA) kinetic model being vital in batch reactors was found invalid in flow-through reactors where fluid mixing was less sufficient.With the increase of H2O2dosage,the ATZ removal efficiency remained almost constant while the SMX and MET removal was enhanced to different extents,which could be explained by the different reactivities of the pollutants towards HO·.A larger reactor ID resulted in lower degradation rate constants for all the three pollutants on account of the lower average fluence rate,but the change in energy efficiency was much more complicated.In reality,the electrical energy per order (EEO) of the investigated VUV/UV/H2O2treatments ranged between 0.14–0.20,0.07–0.14 and 0.09–0.26 k Wh/m3/order for ATZ,SMX and MET,respectively,with the lowest EEOfor each pollutant obtained under varied H2O2dosages and reactor IDs.This study has demonstrated the efficiency of VUV/UV/H2O2process for micropollutant removal and the inadequacy of the SSA model in flow-through reactors,and elaborated the influential mechanisms of H2O2dosage and reactor ID on the reactor performances.展开更多
The microstructure of aqueous CuCl2 has been studied through lots of technologies for many years; however, it remains a controversial subject. In this study, a new spectroscopic method has been proposed to analyze the...The microstructure of aqueous CuCl2 has been studied through lots of technologies for many years; however, it remains a controversial subject. In this study, a new spectroscopic method has been proposed to analyze the UV-visible spectra of thin fihn of CuCl2/H2O solutions at different concentrations. This method is the combination of ratio spectra, difference spectra and second order difference spectra. By using this method, two new bands at -230 and -380 nm are obviously observed. The bands are assigned as the contacted ion pairs [CuCl3(H2O)n]- or [CuCl4(H2O)n]2-, which demonstrates that ion pairs exist in the CuCl2/H2O solution. Such finding agrees with the recent theoretical spectra obtained by time-dependent density functional theory. Furthermore, the populations of the contacted ion pairs are discussed. This study not only offers the direct spectroscopic evidence of [CuCl3(H2O)n]- or [CuCl4(H2O)n]2- in aqueous CuCl2, but also suggests that the spec- troscopic analysis method is powerful to extract the weak bands in a strong overlapping spectrum.展开更多
文摘制备了负载在Na Y分子筛上的Fe Cu Mn Y复合催化剂,并对其在非均相UV Fe Cu Mn Y H2O2体系中催化氧化4BS染料废水进行了研究.结果表明,非均相UV Fe Cu Mn Y H2O2体系对4BS染料废水的处理具有很高的效率.在基准条件下,反应时间为20min时,废水中4BS的去除率达到了93 7%.与均相UV Fenton体系不同,非均相UV Fe Cu Mn Y H2O2体系在碱性条件下(pH=10 5)仍可高效去除CODCr.动力学研究得到催化氧化4BS废水的模型方程,该模型可以为非均相UV Fe Cu Mn Y H2O2体系处理高色度的实际染料废水提供指导.
文摘A novel coordination polymer, [Fe(C 5H 4NCOO) 2] n, was synthesized by hydrothermal reaction and characterized by elemental analysis as well as IR spectroscopy. The crystal structure (with a novel 3-D network) of this compound belongs to monoclinic, space group P2 1/n, a=0.49544(1) nm, b=1.32443(2) nm, c=1.04983(1) nm, β=101.586(1)°. The diffuse reflectance spectra (200~2500 nm) showed that the polymer had strong absorbance in 375~563 nm (E g≈2.5 eV) region and weak absorbance from 720 to 2500 nm (near infrared spectra).
文摘为去除废水中的焦糖色素,采用H2O2/Fe2+和H2O2/Fe2+/UV对焦糖色素去除进行研究.实验考察了H2O2和Fe2+投加量、pH值、反应时间对焦糖色素去除率的影响,在此基础上进一步考察了H2O2/Fe2+/UV对焦糖色素去除效果.结果表明,对于芬顿试剂,H2O2与Fe2+反应的化学计量数为8;pH值为3,反应时间30 m in时,焦糖色的去除效果较好,去除率达到83%.采用H2O2/Fe2+/UV可进一步提高焦糖色的去除效果,去除率可提高到90%.因此采用H2O2/Fe2+或H2O2/Fe2+/UV法获得良好的焦糖色去除效果.
基金supported by the National Natural Science Foundation of China(No.51908536)the Ministry of Science and Technology of China(No.2018YFE0204103)。
文摘The degradation of atrazine (ATZ),sulfamethoxazole (SMX) and metoprolol (MET) in flowthrough VUV/UV/H2O2reactors was investigated with a focus on the effects of H2O2dosage and reactor internal diameter (ID).Results showed that the micropollutants were degraded efficiently in the flow-through VUV/UV/H2O2reactors following the pseudo first-order kinetics (R2>0.92).However,the steady-state assumption (SSA) kinetic model being vital in batch reactors was found invalid in flow-through reactors where fluid mixing was less sufficient.With the increase of H2O2dosage,the ATZ removal efficiency remained almost constant while the SMX and MET removal was enhanced to different extents,which could be explained by the different reactivities of the pollutants towards HO·.A larger reactor ID resulted in lower degradation rate constants for all the three pollutants on account of the lower average fluence rate,but the change in energy efficiency was much more complicated.In reality,the electrical energy per order (EEO) of the investigated VUV/UV/H2O2treatments ranged between 0.14–0.20,0.07–0.14 and 0.09–0.26 k Wh/m3/order for ATZ,SMX and MET,respectively,with the lowest EEOfor each pollutant obtained under varied H2O2dosages and reactor IDs.This study has demonstrated the efficiency of VUV/UV/H2O2process for micropollutant removal and the inadequacy of the SSA model in flow-through reactors,and elaborated the influential mechanisms of H2O2dosage and reactor ID on the reactor performances.
文摘The microstructure of aqueous CuCl2 has been studied through lots of technologies for many years; however, it remains a controversial subject. In this study, a new spectroscopic method has been proposed to analyze the UV-visible spectra of thin fihn of CuCl2/H2O solutions at different concentrations. This method is the combination of ratio spectra, difference spectra and second order difference spectra. By using this method, two new bands at -230 and -380 nm are obviously observed. The bands are assigned as the contacted ion pairs [CuCl3(H2O)n]- or [CuCl4(H2O)n]2-, which demonstrates that ion pairs exist in the CuCl2/H2O solution. Such finding agrees with the recent theoretical spectra obtained by time-dependent density functional theory. Furthermore, the populations of the contacted ion pairs are discussed. This study not only offers the direct spectroscopic evidence of [CuCl3(H2O)n]- or [CuCl4(H2O)n]2- in aqueous CuCl2, but also suggests that the spec- troscopic analysis method is powerful to extract the weak bands in a strong overlapping spectrum.