Elbow dislocations are rare injuries in children due to the resistance of the capsuloligamentous structures. Anterior dislocation is very rare and its combination with an olecranon fracture is unusual. The authors rep...Elbow dislocations are rare injuries in children due to the resistance of the capsuloligamentous structures. Anterior dislocation is very rare and its combination with an olecranon fracture is unusual. The authors report a case of this lesion in a 7-year-old child managed nonoperatively.展开更多
BACKGROUND Supracondylar humeral fractures(SCHF)are the second most common fractures in childhood and can lead to short-and long-term complications.Despite their prevalence,the anatomical factors that predispose child...BACKGROUND Supracondylar humeral fractures(SCHF)are the second most common fractures in childhood and can lead to short-and long-term complications.Despite their prevalence,the anatomical factors that predispose children to SCHF remain unclear.This study aimed to determine whether there are significant morpho-logical differences in the elbow by comparing the radiographic angular measure-ments of the contralateral elbows of patients with SCHF to those of patients with distal radius fractures(DRF)and a healthy control group.We sought to explore if these morphological variations contribute to the occurrence of SCHF.Radiographs of 78 SCHF patients were analyzed for angular measurements of the contralateral elbow.Two control groups were used:98 healthy children and 40 patients with DRF.Angular measurements included Baumann angle(BA),hu-meroulnar angle(HUA),humerus metaphysis-diaphysis angle(HMDA),humerus shaft-condylar angle(HSCA),and lateral capitellohumeral angle.Only BA,HUA,and HMDA were measured in the DRF group.Statistical analysis was performed to compare differences among groups.RESULTS Significant differences were found in elbow measurements between SCHF and control groups(P<0.05).However,the mean values for all groups fell within the ranges described in the literature.CONCLUSION While statistically significant differences were found in elbow morphology between SCHF patients and controls,these differences don't translate into clinically meaningful morphological deviations.展开更多
Gas-liquid flow(GLF),especially slug and annular flows in oil and gas gathering and transportation pipelines,become particularly complex inside elbows and can easily exacerbate pipeline corrosion and damage.In thisstu...Gas-liquid flow(GLF),especially slug and annular flows in oil and gas gathering and transportation pipelines,become particularly complex inside elbows and can easily exacerbate pipeline corrosion and damage.In thisstudy,FLUENT was used to conduct 3D simulations of slug and annular flow in elbows for different velocitiesto assess the ensuing changes in terms of pressure.In particular,the multifluid VOF(Volume of Fraction)modelwas chosen.The results indicate that under both slug and annular flow conditions,the pressure inside the elbow islower than the outside.As the superficial velocity of liquid and gas increase,the pressure and liquid flow velocityat different positions of the elbow also increase,while the secondary flow weakens.Under annular flow conditions,the liquid film on the outer side of the elbow is thicker than that on the inner side,and the liquid velocityin the main liquid film zone is the lowest.展开更多
Aimed at the S-elbow composed of two elbows with different radii, this article proposes a winding pattern design method combined with patch winding method and traditional winding method. It proposes an optimal combina...Aimed at the S-elbow composed of two elbows with different radii, this article proposes a winding pattern design method combined with patch winding method and traditional winding method. It proposes an optimal combination of calculating the tangential point amount and skip point amount to make the pattern distribution even and keep the minimal adjusting angle. The S-elbow overall winding pattem plan and simulation module are designed to verify the combined winding pattern design method and the calculation algorithm of the tangential point amount and skip point amount. From the pattern distribution and the simula- tion effect analysis, it shows that this combined winding pattern design method is a good solution to the S-elbow combined winding pattern design. Aimed at the S-elbow winding pattern based on the patch winding method, it carries out the precision error analysis and points out the correspondence between the error and mesh size. Generally speaking, the bigger the mesh size is, the quicker the program calculation speed is; the smaller the mesh size is, the smaller the winding pattern error is.展开更多
Prof. FANG Jian-qiao is good at clinical and basic study on acupuncture analgesia. The therapeutic efficacy in treating tennis elbow of Prof. Fang is significant,"needling painful point" on the basis of clarifying c...Prof. FANG Jian-qiao is good at clinical and basic study on acupuncture analgesia. The therapeutic efficacy in treating tennis elbow of Prof. Fang is significant,"needling painful point" on the basis of clarifying causes and pathogenesis of this disease in TCM and western medicine,treat this disease by using encircling needling in combina on with warm needling moxibus on,and it is convenient,safe and eff ec ve. The encircling needling in combina on with warm needling moxibus on has obvious advantages in trea ng external humeral epicondyli s.展开更多
A loop system was used to investigate the effect of flow velocity on corrosion behavior of AZ91 D magnesium alloy at an elbow of loop system based on array electrode technology by polarization, computational fluid dyn...A loop system was used to investigate the effect of flow velocity on corrosion behavior of AZ91 D magnesium alloy at an elbow of loop system based on array electrode technology by polarization, computational fluid dynamics(CFD) simulation and surface analysis. The experimental results showed that the corrosion rate increased with increasing flow velocity, and a critical flow velocity could exist in the corrosion of AZ91 D magnesium alloy. When flow velocity exceeded the critical flow velocity, fluid hydrodynamics was dominant in the corrosion of AZ91 D magnesium alloy. On the contrary, the electrochemical factors were dominant.展开更多
文摘Elbow dislocations are rare injuries in children due to the resistance of the capsuloligamentous structures. Anterior dislocation is very rare and its combination with an olecranon fracture is unusual. The authors report a case of this lesion in a 7-year-old child managed nonoperatively.
文摘BACKGROUND Supracondylar humeral fractures(SCHF)are the second most common fractures in childhood and can lead to short-and long-term complications.Despite their prevalence,the anatomical factors that predispose children to SCHF remain unclear.This study aimed to determine whether there are significant morpho-logical differences in the elbow by comparing the radiographic angular measure-ments of the contralateral elbows of patients with SCHF to those of patients with distal radius fractures(DRF)and a healthy control group.We sought to explore if these morphological variations contribute to the occurrence of SCHF.Radiographs of 78 SCHF patients were analyzed for angular measurements of the contralateral elbow.Two control groups were used:98 healthy children and 40 patients with DRF.Angular measurements included Baumann angle(BA),hu-meroulnar angle(HUA),humerus metaphysis-diaphysis angle(HMDA),humerus shaft-condylar angle(HSCA),and lateral capitellohumeral angle.Only BA,HUA,and HMDA were measured in the DRF group.Statistical analysis was performed to compare differences among groups.RESULTS Significant differences were found in elbow measurements between SCHF and control groups(P<0.05).However,the mean values for all groups fell within the ranges described in the literature.CONCLUSION While statistically significant differences were found in elbow morphology between SCHF patients and controls,these differences don't translate into clinically meaningful morphological deviations.
基金supported by the Ministry of Industry and Information Technology High Tech Ship Special Project(Grant No.CBG3N21-2-6).
文摘Gas-liquid flow(GLF),especially slug and annular flows in oil and gas gathering and transportation pipelines,become particularly complex inside elbows and can easily exacerbate pipeline corrosion and damage.In thisstudy,FLUENT was used to conduct 3D simulations of slug and annular flow in elbows for different velocitiesto assess the ensuing changes in terms of pressure.In particular,the multifluid VOF(Volume of Fraction)modelwas chosen.The results indicate that under both slug and annular flow conditions,the pressure inside the elbow islower than the outside.As the superficial velocity of liquid and gas increase,the pressure and liquid flow velocityat different positions of the elbow also increase,while the secondary flow weakens.Under annular flow conditions,the liquid film on the outer side of the elbow is thicker than that on the inner side,and the liquid velocityin the main liquid film zone is the lowest.
基金National Natural Science Foundation of China (50905088)Science and Technoloy Major Project (2009ZX04004-102)
文摘Aimed at the S-elbow composed of two elbows with different radii, this article proposes a winding pattern design method combined with patch winding method and traditional winding method. It proposes an optimal combination of calculating the tangential point amount and skip point amount to make the pattern distribution even and keep the minimal adjusting angle. The S-elbow overall winding pattem plan and simulation module are designed to verify the combined winding pattern design method and the calculation algorithm of the tangential point amount and skip point amount. From the pattern distribution and the simula- tion effect analysis, it shows that this combined winding pattern design method is a good solution to the S-elbow combined winding pattern design. Aimed at the S-elbow winding pattern based on the patch winding method, it carries out the precision error analysis and points out the correspondence between the error and mesh size. Generally speaking, the bigger the mesh size is, the quicker the program calculation speed is; the smaller the mesh size is, the smaller the winding pattern error is.
基金Supported by a construc on project of inheritance studio of TCM of old Chinese medicine experts:GZS 2012014a na onal construc on project of inheritance studio of TCM of old Chinese medicine experts in 2013
文摘Prof. FANG Jian-qiao is good at clinical and basic study on acupuncture analgesia. The therapeutic efficacy in treating tennis elbow of Prof. Fang is significant,"needling painful point" on the basis of clarifying causes and pathogenesis of this disease in TCM and western medicine,treat this disease by using encircling needling in combina on with warm needling moxibus on,and it is convenient,safe and eff ec ve. The encircling needling in combina on with warm needling moxibus on has obvious advantages in trea ng external humeral epicondyli s.
基金Project(51401151)supported by the National Natural Science Foundation of ChinaProjects(2015T80792,2012M511207)supported by the Postdoctoral Science Foundation of China
文摘A loop system was used to investigate the effect of flow velocity on corrosion behavior of AZ91 D magnesium alloy at an elbow of loop system based on array electrode technology by polarization, computational fluid dynamics(CFD) simulation and surface analysis. The experimental results showed that the corrosion rate increased with increasing flow velocity, and a critical flow velocity could exist in the corrosion of AZ91 D magnesium alloy. When flow velocity exceeded the critical flow velocity, fluid hydrodynamics was dominant in the corrosion of AZ91 D magnesium alloy. On the contrary, the electrochemical factors were dominant.