期刊文献+
共找到4,462篇文章
< 1 2 224 >
每页显示 20 50 100
Electromagnetic transient equivalent model of dual active bridge based on the generalized branch-cutting method
1
作者 WU Zhi CHEN Shuaixian +5 位作者 XU Mingwang CAO Yang GU Wei LIU Wei YUAN Xiaodong HAN Huachun 《Journal of Southeast University(English Edition)》 2025年第2期156-163,共8页
The traditional detailed model of the dual active bridge(DAB)power electronic transformer is characterized by the high dimensionality of its nodal admittance matrix and the need for a small simulation step size,which ... The traditional detailed model of the dual active bridge(DAB)power electronic transformer is characterized by the high dimensionality of its nodal admittance matrix and the need for a small simulation step size,which limits the speed of electromagnetic transient(EMT)simulations.To overcome these limitations,a novel EMT equivalent model based on a generalized branch-cutting method is proposed to improve the simulation efficiency of the DAB model.The DAB topology is first decomposed into two subnetworks through branch-cutting and node-tearing methods without the introduction of a one-time-step delay.Sub-sequently,the internal nodes of each sub-network are eliminated through network simplification,and the equivalent circuit for the port cascade module is derived.The model is then validated through simulations across various operating conditions.The results demonstrate that the model avoids the loss of accuracy associated with one-time-step delay,the relative error across different conditions remains below 1%,and the simulation acceleration ratios improve as the number of modules increases. 展开更多
关键词 electromagnetic transient simulation dual active bridge node-tearing branch-cutting method network simplification
在线阅读 下载PDF
Coupling Magneto-Electro-Elastic Multiscale Finite Element Method for Transient Responses of Heterogeneous MEE Structures
2
作者 Xiaolin Li Xinyue Li +2 位作者 Liming Zhou Hangran Yang Xiaoqing Yuan 《Computers, Materials & Continua》 2025年第3期3821-3841,共21页
Magneto-electro-elastic(MEE)materials are widely utilized across various fields due to their multi-field coupling effects.Consequently,investigating the coupling behavior of MEE composite materials is of significant i... Magneto-electro-elastic(MEE)materials are widely utilized across various fields due to their multi-field coupling effects.Consequently,investigating the coupling behavior of MEE composite materials is of significant importance.The traditional finite element method(FEM)remains one of the primary approaches for addressing such issues.However,the application of FEM typically necessitates the use of a fine finite element mesh to accurately capture the heterogeneous properties of the materials and meet the required computational precision,which inevitably leads to a reduction in computational efficiency.To enhance the computational accuracy and efficiency of the FEM for heterogeneous multi-field coupling problems,this study presents the coupling magneto-electro-elastic multiscale finite element method(CM-MsFEM)for heterogeneous MEE structures.Unlike the conventional multiscale FEM(MsFEM),the proposed algorithm simultaneously constructs displacement,electric,and magnetic potential multiscale basis functions to address the heterogeneity of the corresponding parameters.The macroscale formulation of CM-MsFEM was derived,and the macroscale/microscale responses of the problems were obtained through up/downscaling calculations.Evaluation using numerical examples analyzing the transient behavior of heterogeneous MEE structures demonstrated that the proposed method outperforms traditional FEM in terms of both accuracy and computational efficiency,making it an appropriate choice for numerically modeling the dynamics of heterogeneous MEE structures. 展开更多
关键词 Multiscale finite element method heterogeneous materials transient responses MAGNETO-ELECTRO-ELASTIC multiscale basis function
在线阅读 下载PDF
Discussion on the application prospect of the transient electromagnetic method based on the dual launcher and mine advanced detection
3
作者 Zhen Yang Huizhou Liu +5 位作者 Shengqing Wang Yu Cao Ya Dong Chenghu Niu Weiwen Song Guoxin Xie 《World Journal of Condensed Matter Physics》 CAS 2024年第1期21-33,共13页
The dual transmitter implements the equivalent anti-magnetic flux transient electromagnetic method, which can effectively reduce the scope of the transient electromagnetic detection blind area. However, this method is... The dual transmitter implements the equivalent anti-magnetic flux transient electromagnetic method, which can effectively reduce the scope of the transient electromagnetic detection blind area. However, this method is rarely reported in the detection of pipelines in urban geophysical exploration and the application of coal mines. Based on this, this paper realizes the equivalent anti-magnetic flux transient electromagnetic method based on the dual launcher. The suppression effect of this method on the blind area is analyzed by physical simulation. And the detection experiment of underground pipelines is carried out outdoors. The results show that the dual launcher can significantly reduce the turn-off time, thereby effectively reducing the impact of the blind area on the detection results, and the pipeline detection results verify the device’s effectiveness. Finally, based on the ground experimental results, the application prospect of mine advanced detection is discussed. Compared with other detection fields, the formation of blind areas is mainly caused by the equipment. If the dual launcher can be used to reduce the blind area, the accuracy of advanced detection can be improved more effectively. The above research results are of great significance for improving the detection accuracy of the underground transient electromagnetic method. 展开更多
关键词 A Dual Launcher Physical Simulation transient Electromagnetic method Mine Geophysical Prospecting Detection Blind Area Application Prospect
在线阅读 下载PDF
An efficient Agrobacterium-mediated transient expression system in tomato leaflets
4
作者 Ge Wang Jiucheng Zhang +6 位作者 Xuemei Zhang Di Ma Minyu Tian Chunyan Chen Jiapin He Zhilong Bao Fangfang Ma 《Horticultural Plant Journal》 2025年第4期1703-1706,共4页
The Agrobacterium-mediated transient expression system with conventional binary vectors is well established in tobacco leaves,while the same system applied to tomato leaflets has relatively low expression efficiency.H... The Agrobacterium-mediated transient expression system with conventional binary vectors is well established in tobacco leaves,while the same system applied to tomato leaflets has relatively low expression efficiency.However,impacts of the leaf age,inoculation method and incubation condition after Agrobacterium infiltration on transient protein expression efficiency are seldom investigated.In this study,we optimize Agrobacterium-mediated transient expression system using conventional binary vectors to achieve the high efficiency of target gene expression in tomato leaflets.We transiently express GFP and a nucleus-localized gene SlUVI4 fused with GFP in detached 10-,20-,and 30-day-old leaflets.The cutting points of leaflets are embedded in MS medium after the Agrobacterium-mediated vacuum infiltration,and all leaflets are kept in the dark before use.The 10-and 30-day-old leaflets have more damage than 20-day-old leaflets after the infiltration. 展开更多
关键词 agrobacterium infiltration leaf age tobacco leaveswhile incubation condition conventional binary vectors agrobacterium mediated transient expression inoculation method tomato leaflets
在线阅读 下载PDF
Cone-shaped source characteristics and inductance effect of transient electromagnetic method 被引量:11
5
作者 杨海燕 李锋平 +3 位作者 岳建华 郭福生 刘旭华 张华 《Applied Geophysics》 SCIE CSCD 2017年第1期165-174,192,共11页
Small multi-turn coil devices are used with the transient electromagnetic method (TEM) in areas with limited space, particularly in underground environments such as coal mines roadways and engineering tunnels, and f... Small multi-turn coil devices are used with the transient electromagnetic method (TEM) in areas with limited space, particularly in underground environments such as coal mines roadways and engineering tunnels, and for detecting shallow geological targets in environmental and engineering fields. However, the equipment involved has strong mutual inductance coupling, which causes a lengthy turn-off time and a deep “blind zone”. This study proposes a new transmitter device with a conical-shape source and derives the radius formula of each coil and the mutual inductance coefficient of the cone. According to primary field characteristics, results of the two fields created, calculation of the conical-shaped source in a uniform medium using theoretical analysis, and a comparison of the inductance of the new device with that of the multi-turn coil, show that inductance of the multi-turn coil is nine times greater than that of the conical source with the same equivalent magnetic moment of 926.1 A·m2. This indicates that the new source leads to a much shallower “blind zone.” Furthermore, increasing the bottom radius and turn of the cone creates a larger mutual inductance but increasing the cone height results in a lower mutual inductance. Using the superposition principle, the primary and secondary magnetic fields for a conical source in a homogeneous medium are calculated; results indicate that the magnetic behavior of the cone is the same as that of the multi-turn coils, but the transient responses of the secondary field and the total field are more stronger than those of the multi-turn coils. To study the transient response characteristics using a cone-shaped source in a layered earth, a numerical filtering algorithm is then developed using the fast Hankel transform and the improved cosine transform, again using the superposition principle. During development, an average apparent resistivity inverted from the induced electromotive force using each coil is defined to represent the comprehensive resistivity of the conical source. To verify the forward calculation method, the transient responses of H type models and KH type models are calculated, and data are inverted using a “smoke ring” inversion. The results of inversion have good agreement with original models and show that the forward calculation method is effective. The results of this study provide an option for solving the problem of a deep “blind zone” and also provide a theoretical indicator for further research. 展开更多
关键词 transient electromagnetic method Cone-shaped source Apparent resistivity Mutual inductance “Smoke ring” inversion
在线阅读 下载PDF
Numerical analysis of multicomponent responses of surface-hole transient electromagnetic method 被引量:4
6
作者 孟庆鑫 胡祥云 +1 位作者 潘和平 周峰 《Applied Geophysics》 SCIE CSCD 2017年第1期175-186,192,共13页
We calculate the multicomponent responses of surface-hole transient electromagnetic method. The methods and models are unsuitable as geoelectric models of conductive surrounding rocks because they are based on regular... We calculate the multicomponent responses of surface-hole transient electromagnetic method. The methods and models are unsuitable as geoelectric models of conductive surrounding rocks because they are based on regular local targets. We also propose a calculation and analysis scheme based on numerical simulations of the subsurface transient electromagnetic fields. In the modeling of the electromagnetic fields, the forward modeling simulations are performed by using the finite-difference time-domain method and the discrete image method, which combines the Gaver–Stehfest inverse Laplace transform with the Prony method to solve the initial electromagnetic fields. The precision in the iterative computations is ensured by using the transmission boundary conditions. For the response analysis, we customize geoelectric models consisting of near-borehole targets and conductive wall rocks and implement forward modeling simulations. The observed electric fields are converted into induced electromotive force responses using multicomponent observation devices. By comparing the transient electric fields and multicomponent responses under different conditions, we suggest that the multicomponent-induced electromotive force responses are related to the horizontal and vertical gradient variations of the transient electric field at different times. The characteristics of the response are determined by the varying the subsurface transient electromagnetic fields, i.e., diffusion, attenuation and distortion, under different conditions as well as the electromagnetic fields at the observation positions. The calculation and analysis scheme of the response consider the surrounding rocks and the anomalous field of the local targets. It therefore can account for the geological data better than conventional transient field response analysis of local targets. 展开更多
关键词 Surface-hole transient electromagnetic method multicomponent response analysis transient electric field three-dimensional finite-difference time-domain method discrete image method
在线阅读 下载PDF
A study on the discrete image method for calculation of transient electromagnetic fields in geological media 被引量:1
7
作者 孟庆鑫 潘和平 骆淼 《Applied Geophysics》 SCIE CSCD 2015年第4期493-502,626,627,共12页
We conducted a study on the numerical calculation and response analysis of a transient electromagnetic field generated by a ground source in geological media. One solution method, the traditional discrete image method... We conducted a study on the numerical calculation and response analysis of a transient electromagnetic field generated by a ground source in geological media. One solution method, the traditional discrete image method, involves complex operation, and its digital filtering algorithm requires a large number of calculations. To solve these problems, we proposed an improved discrete image method, where the following are realized: the real number of the electromagnetic field solution based on the Gaver-Stehfest algorithm for approximate inversion, the exponential approximation of the objective kernel function using the Prony method, the transient electromagnetic field according to discrete image theory, and closed-form solution of the approximate coefficients. To verify the method, we tentatively calculated the transient electromagnetic field in a homogeneous model and compared it with the results obtained from the Hankel transform digital filtering method. The results show that the method has considerable accuracy and good applicability. We then used this method to calculate the transient electromagnetic field generated by a ground magnetic dipole source in a typical geoelectric model and analyzed the horizontal component response of the induced magnetic field obtained from the "ground excitation-stratum measurement method. We reached the conclusion that the horizontal component response of a transient field is related to the geoelectric structure, observation time, spatial location, and others. The horizontal component response of the induced magnetic field reflects the eddy current field distribution and its vertical gradient variation. During the detection of abnormal objects, positions with a zero or comparatively large offset were selected for the drill- hole measurements or a comparatively long observation delay was adopted to reduce the influence of the ambient field on the survey results. The discrete image method and forward calculation results in this paper can be used as references for relevant research. 展开更多
关键词 Discrete image method transient electromagnetic fields Borehole transientelectromagnetic method Horizontal component response
在线阅读 下载PDF
Equivalent Method of Integrated Power Generation System of Wind, Photovoltaic and Energy Storage in Power Flow Calculation and Transient Simulation 被引量:10
8
作者 王皓怀 汤涌 +3 位作者 侯俊贤 刘楠 李碧辉 张宏宇 《中国电机工程学报》 EI CSCD 北大核心 2012年第1期I0001-I0026,共26页
针对工程实际开展风光储联合发电系统在潮流计算和机电暂态仿真中的等值方法研究,旨在为大容量风光储联合发电系统的并网仿真分析奠定基础。将潮流计算的等值分为单元机组和集电系统2部分来研究。单元机组等值采用根据不同控制模式选... 针对工程实际开展风光储联合发电系统在潮流计算和机电暂态仿真中的等值方法研究,旨在为大容量风光储联合发电系统的并网仿真分析奠定基础。将潮流计算的等值分为单元机组和集电系统2部分来研究。单元机组等值采用根据不同控制模式选取不同节点类型的方法,针对集电系统等值提出基于损耗不变原则的方法。等值模型和详细模型的算例结果表明,潮流计算等值方法具有较好的精度。在机电暂态仿真动态等值中,基于实际工程计算的最严重工况分析原则,提出运行在满出力点的单机“倍乘”等值模型,为工程计算中的风光储联合发电系统动态等值提供了一种解决方案。 展开更多
关键词 综合发电系统 暂态仿真 光伏发电 潮流计算 等效方法 电力系统 风能 功率
原文传递
Mapping coalmine goaf using transient electromagnetic method and high density resistivity method in Ordos City, China 被引量:17
9
作者 Guiju Wu Guangliang Yang Hongbo Tan 《Geodesy and Geodynamics》 2016年第5期340-347,共8页
The research about subsurface characteristics by using transient electromagnetic method(TEM) and high density resistivity method(HDRM) were already conducted in Ordos. The objective of this research is to detect c... The research about subsurface characteristics by using transient electromagnetic method(TEM) and high density resistivity method(HDRM) were already conducted in Ordos. The objective of this research is to detect coalmine goaf areas based on rock resistivity. The data processing using wavelet transform, three point smoothing, RES2 DINV and Maxwell processing software to obtain 2D resistivity structure. The results showed that the layers with maximum resistivity values(30e33 U m on Line 1, 30e31 U m on Line 2, 32e40 U m on Line3) are founded at station 1e7, and 14e20 on Line 1,13e18 on Line 2, and 8e13 and 16e20 on Line 3 which is predicted as goaf layer, and the minimum resistivity values(20e26 U m of TEM, 45e75 U m of HDRM) at the other layers. This resistivity difference was caused by the geology and characteristics of the study area which is located close by the cleugh with rich coal, so the goaf area distinguishable with aquifer layer and coal seam. The results were also significant accidents and serious destruction of ecological environment. 展开更多
关键词 transient electromagnetic method High density resistivity method Coalmine goaf areas GEOTECHNICAL ELECTRICAL
原文传递
Transient analysis of 1D inhomogeneous media by dynamic inhomogeneous finite element method 被引量:4
10
作者 Yang Zailin Wang Yao Hei Baoping 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期569-576,共8页
The dynamic inhomogeneous finite element method is studied for use in the transient analysis of one dimensional inhomogeneous media. The general formula of the inhomogeneous consistent mass matrix is established based... The dynamic inhomogeneous finite element method is studied for use in the transient analysis of one dimensional inhomogeneous media. The general formula of the inhomogeneous consistent mass matrix is established based on the shape function. In order to research the advantages of this method, it is compared with the general finite element method. A linear bar element is chosen for the discretization tests of material parameters with two fictitious distributions. And, a numerical example is solved to observe the differences in the results between these two methods. Some characteristics of the dynamic inhomogeneous finite element method that demonstrate its advantages are obtained through comparison with the general finite element method. It is found that the method can be used to solve elastic wave motion problems with a large element scale and a large number of iteration steps. 展开更多
关键词 inhomogeneous media elastic wave transient analysis dynamic inhomogeneous finite element method DISCRETIZATION
在线阅读 下载PDF
A new complex variable meshless method for transient heat conduction problems 被引量:5
11
作者 王健菲 程玉民 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第12期42-50,共9页
In this paper, based on the improved complex variable moving least-square (ICVMLS) approximation, a new complex variable meshless method (CVMM) for two-dimensional (2D) transient heat conduction problems is pres... In this paper, based on the improved complex variable moving least-square (ICVMLS) approximation, a new complex variable meshless method (CVMM) for two-dimensional (2D) transient heat conduction problems is presented. The variational method is employed to obtain the discrete equations, and the essential boundary conditions are imposed by the penalty method. As the transient heat conduction problems are related to time, the Crank-Nicolson difference scheme for two-point boundary value problems is selected for the time discretization. Then the corresponding formulae of the CVMM for 2D heat conduction problems are obtained. In order to demonstrate the applicability of the proposed method, numerical examples are given to show the high convergence rate, good accuracy, and high efficiency of the CVMM presented in this paper. 展开更多
关键词 meshless method improved complex variable moving least-square approximation com-plex variable meshless method transient heat conduction problem
原文传递
Experiment in metal disturbance during advanced detection using a transient electromagnetic method in coal mines 被引量:14
12
作者 JIANG Zhihai YUE Jianhua YU Jingcun 《Mining Science and Technology》 EI CAS 2010年第6期861-863,共3页
Tunneling machines, or excavators, are large and good conductors and affect the reliability of data gathering and interpretation in advanced detection using transient electromagnetic methods. In our experiment, we use... Tunneling machines, or excavators, are large and good conductors and affect the reliability of data gathering and interpretation in advanced detection using transient electromagnetic methods. In our experiment, we used a coincident-loop and central loop type of configuration, where the coil plane l) vertical to and 2) parallel to the working face. A SIROTEM instrument at different locations was used to observe the transient electromagnetic responses of the excavator and to analyze the response amplitudes. The result shows that the tunneling machine affects the advanced detection data and is related to the way the coil is coupled. When the excavator is 6 m from the observatory, the interference of tunneling machine can be ignored. 展开更多
关键词 transient electromagnetic method advanced detection metal disturbance driving face
在线阅读 下载PDF
Prediction Technology of Buried Water-Bearing Structures in Coal Mines Using Transient Electromagnetic Method 被引量:21
13
作者 JIANG Zhi-hai YUE Jian-hua LIU Shu-cai 《Journal of China University of Mining and Technology》 EI 2007年第2期164-167,共4页
Buried water-conducting and water-bearing structures in front of the driving head may easily lead to water bursts in coal mines. Therefore,it is very important for the safety of production to make an accurate and time... Buried water-conducting and water-bearing structures in front of the driving head may easily lead to water bursts in coal mines. Therefore,it is very important for the safety of production to make an accurate and timely forecast about water bursts. Based on the smoke ring effect of transient electromagnetic fields,the principle of transient electro-magnetic method used in detecting buried water-bearing structures in coal mines in advance,is discussed. Small multi-turn loop configurations used in coal mines are proposed and a field procedure of semicircular sector scanning is presented. The application of this method in one coal mine indicates that the technology has many advantages compared with others. The method is inexpensive,highly accurate and efficient. Suggestions are presented for future solutions to some remaining problems. 展开更多
关键词 mine transient electromagnetic method advance detection water-bearing structure small multi-turn loop sector scanning
在线阅读 下载PDF
Alterable-element Method for Vehicle-bridge Interaction Considering the Transient Jump of Wheel 被引量:7
14
作者 吴川 刘学文 黄醒春 《Journal of Shanghai Jiaotong university(Science)》 EI 2008年第3期330-335,共6页
The so called "alterable-element method" (AEM) was introduced to deal with the coupling interac-tion of vehicle and sub-structure considering the actual transient jump of wheel, while the classical "con... The so called "alterable-element method" (AEM) was introduced to deal with the coupling interac-tion of vehicle and sub-structure considering the actual transient jump of wheel, while the classical "contact all along" assumption based on which wheels and lower structure are always contact was abandoned. The alterable element used in this method is a conceptional element, which is used to calculate the coupling interaction of upper and lower structures and has some typical characteristics: firstly it flows along with the moving of contact point; secondly whether it is used for calculation depends on the contact state; thirdly its sizes could change according to specific problems and so on. VISUAL FORTRAN program was coded, and different moving vehicle models were presented taking into consideration the effects of random corrugation in the numerical study. The numerical solutions are favored comparing with the results obtained by alternative methods when there is no jump phenomenon existed. With abrupt irregularity, the transient jump of wheel was studied using the present method. 展开更多
关键词 alterable-element method (AEM) vehicle-bridge interaction transient jump
在线阅读 下载PDF
Combining the complex variable reproducing kernel particle method and the finite element method for solving transient heat conduction problems 被引量:2
15
作者 陈丽 马和平 程玉民 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第5期67-74,共8页
In this paper, the complex variable reproducing kernel particle (CVRKP) method and the finite element (FE) method are combined as the CVRKP-FE method to solve transient heat conduction problems. The CVRKP-FE metho... In this paper, the complex variable reproducing kernel particle (CVRKP) method and the finite element (FE) method are combined as the CVRKP-FE method to solve transient heat conduction problems. The CVRKP-FE method not only conveniently imposes the essential boundary conditions, but also exploits the advantages of the individual methods while avoiding their disadvantages, then the computational efficiency is higher. A hybrid approximation function is applied to combine the CVRKP method with the FE method, and the traditional difference method for two-point boundary value problems is selected as the time discretization scheme. The corresponding formulations of the CVRKP-FE method are presented in detail. Several selected numerical examples of the transient heat conduction problems are presented to illustrate the performance of the CVRKP-FE method. 展开更多
关键词 complex variable reproducing kernel particle method finite element method combined method transient heat conduction
原文传递
Coupling Magneto-Electro-Elastic node-based smoothed radial point interpolation method for free vibration and transient analysis of Functionally Graded Magneto-Electro-Elastic structures 被引量:2
16
作者 Liming ZHOU Shuhui REN +2 位作者 Bin NIE Guikai GUO Xiangyang CUI 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2020年第1期227-243,共17页
A Coupling Magneto-Electro-Elastic(MEE)Node-based Smoothed Radial Point Interpolation Method(CM-NS-RPIM)was proposed to solve the free vibration and transient responses of Functionally Graded Magneto-Electro-Elastic(F... A Coupling Magneto-Electro-Elastic(MEE)Node-based Smoothed Radial Point Interpolation Method(CM-NS-RPIM)was proposed to solve the free vibration and transient responses of Functionally Graded Magneto-Electro-Elastic(FGMEE)structures.By introducing the modified Newmark method,the displacement,electrical potential and magnetic potential of the structures under transient mechanical loading were obtained.Based on G space theory and the weakened weak(W2)formulation,the equations of the multi-physics coupling problems were derived.Using triangular background elements,the free vibration and transient responses of three numerical examples were studied.Results proved that CM-NS-RPIM performed better than the standard FEM by reducing the overly-stiff of structures.Moreover,CM-NS-RPIM could reduce the number of nodes while guaranteeing the accuracy.Besides,triangular elements could be generated automatically even for complex geometries.Therefore,the effectiveness and validity of CM-NS-RPIM were demonstrated,which were valuable for the design of intelligence devices,such as energy harvesters and sensors. 展开更多
关键词 COUPLING MAGNETO-ELECTRO-ELASTIC node-based smoothed radial point interpolation method Functionally Graded MAGNETO-ELECTRO-ELASTIC Gradient smoothing technique Rayleigh damping transient responses
原文传递
Transient characteristics verification method for DC transformer used in flexible HVDC system 被引量:2
17
作者 Qi Nie Haoliang Hu +3 位作者 Dengyun Li Boyang Liu He Li Qianzhu Xiong 《Global Energy Interconnection》 2019年第2期180-187,共8页
Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider band... Previous studies have proposed higher requirements for the transient characteristics of a DC transformer used in a flexible high-voltage direct current(HVDC) system to achieve faster sampling speed and meet wider bandwidth requirements of the control and protection signal, and to eventually suppress the large transient fault current. In this study, a transient characteristics verification method is proposed for transient characteristics verification of a DC transformer used in a flexible HVDC system based on resampling technology and LabVIEW measurement technology after analyzing the key technology for transient characteristics verification of a DC transformer. A laboratory experiment for the transient characteristics of a full-fiber electronic DC transformer is conducted, and experimental results show that such verification method can be employed for frequency response and step response verification of a DC transformer at 10% of the rated voltage and current, and can eventually improve the screening of a DC transformer. 展开更多
关键词 DC TRANSFORMER STEP response transient CHARACTERISTIC RESAMPLING technology Verification method
在线阅读 下载PDF
Study on the Coincident-Loop Transient Electromagnetic Method in Seafloor Exploration——Taking Jiaodong Polymetallic Mine as a Model 被引量:3
18
作者 Yixing Ma Junhua Hu +1 位作者 Yanjun Chang Zujian Liu 《Journal of Earth Science》 SCIE CAS CSCD 2021年第1期25-41,共17页
The transient electromagnetic(TEM)method becomes more urgent than ever for marine ex-ploration due to abundant resource reserves and the increasing undersea engineering construction activities,especially in the offsho... The transient electromagnetic(TEM)method becomes more urgent than ever for marine ex-ploration due to abundant resource reserves and the increasing undersea engineering construction activities,especially in the offshore exploration of mineral deposits such as Sanshandao gold mine.However,the re-search and application of TEM method in marine environment are still challenged by many problems.Such contradiction motivates our study on the coincident-loop TEM in seafloor exploration.The TEM response of coincident loops is firstly derived in the integral form,based on the potential functions in Helmholtz equ-ations for a magnetic source locating in the whole-space layered model.The frequency-domain vertical magnetic field is described as the Hankel integral with double first-order Bessel functions of first kind.Se-condly,the time-domain induced voltage is obtained by transforming the frequency-domain response through the cosine transform and then taking the derivative of time.To simultaneously solve the Hankel transform and the cosine transform,a novel algorithm is introduced by adapting the fixed-point quadra-ture and extrapolation via the Shanks transformation.Finally,a typical conductivity model for marine po-lymetallic deposit is designed to investigate the characteristic of TEM response under various conditions.Numerical results demonstrate that existence of conductive seawater causes the TEM response to increase significantly and decay slower.The air-sea reflected electromagnetic waves lead to a significantly large fake negative response(NR)in shallower seawater with depth less than 300 m.Increase in the height of loops will weaken and delay the anomaly response and shorten the observation time-window.The height of configu-ration should be no more than 100 m for shallower targets and 50 m for deeper targets,respectively.The observation time-window should cover 10-1000 ms.Increase in the radius of loops only enhances the TEM response proportionally but hardly improves the relative anomaly.The vertical resolution on the low-resistivity target approximates 20 m for the configuration considered in the study.Decreases in D.C.resistivity and chargeability cause the positive response(PR)to increase significantly and decay more ra-pidly.Meanwhile,the NR is advanced and enlarged significantly and decays slower compared with the PR.The influence of time constant is not monotony and there exists an optimal value for producing the maxi-mum NR.As the frequency parameter increases,the PR is caused to decay more rapidly without magni-tude change and the NR is advanced and decays more rapidly with significant increase in magnitude.The influence of frequency parameter is more pronounced than that of time constant. 展开更多
关键词 marine transient electromagnetic method coincident loops induced polarization air-wave effects
原文传递
Calculation of all-time apparent resistivity of large loop transient electromagnetic method with very fast simulated annealing 被引量:4
19
作者 李建慧 朱自强 +2 位作者 冯德山 肖建平 彭凌星 《Journal of Central South University》 SCIE EI CAS 2011年第4期1235-1239,共5页
In large loop transient electromagnetic method(TEM),the late time apparent resistivity formula cannot truly reflect the geoelectric model,thus it needs to define the all-time apparent resistivity with the position inf... In large loop transient electromagnetic method(TEM),the late time apparent resistivity formula cannot truly reflect the geoelectric model,thus it needs to define the all-time apparent resistivity with the position information of measuring point.Utilizing very fast simulated annealing(VFSA) to fit the theoretical electromagnetic force(EMF) and measured EMF could obtain the all-time apparent resistivity of the measuring points in rectangular transmitting loop.The selective cope of initial model of VFSA could be confirmed by taking the late time apparent resistivity of transient electromagnetic method as the prior information.For verifying the correctness,the all-time apparent resistivities of the geoelectric models were calculated by VFSA and dichotomy,respectively.The results indicate that the relative differences of apparent resistivities calculated by these two methods are within 3%.The change of measuring point position has little influence on the tracing pattern of all-time apparent resistivity.The first branch of the curve of all-time apparent resistivity is close to the resistivity of the first layer medium and the last branch is close to the resistivity of the last layer medium,which proves the correctness of the arithmetics proposed. 展开更多
关键词 very fast simulated annealing (VFSA) large loop transient electromagnetic method rectangular loop all-time apparent resistivity
在线阅读 下载PDF
Simulation research and application on response characteristics of detecting water-filled goaf by transient electromagnetic method 被引量:3
20
作者 Tingye Qi Fan Zhang +2 位作者 Xiaoming Pei Guorui Feng Huiru Wei 《International Journal of Coal Science & Technology》 EI CAS CSCD 2022年第2期167-192,共26页
Water inrush disasters poses a great threat to the safe exploitation of coal resources.To solve this problem,the transient electromagnetic method(TEM)was proposed to accurately detect the water accumulation in the goa... Water inrush disasters poses a great threat to the safe exploitation of coal resources.To solve this problem,the transient electromagnetic method(TEM)was proposed to accurately detect the water accumulation in the goaf.The electromagnetic response characteristics of diferent water-flled goaves were studied by electromagnetic feld theory,numerical simulation and feld verifcation.Through the models of 100%water accumulation,50%water accumulation,0%water accumulation,100%water accumulation with collapsed rock,50%water accumulation with collapsed rock and 0%water accumulation with collapsed rock goaf,the characteristics of induced voltage attenuation curves were studied.Meanwhile,the relationship between the attenuation voltage value and area of the transmitting coil,the depth of the goaf,the background resistivity,and the delay time were also simulated.The results illustrate that the attenuation curve of induced voltage presented a regular exponential decay form in the 0%water accumulation model but existed abnormal exaltation for voltage in water-flled model.Through the linear ftting curve,it can be seen that the abnormal intensity of the induced voltage becomes stronger as the distance between the measuring point and the center of the target decrement.Moreover,the abnormal amplitude of the induced voltage increases with the rise of the water accumulation and collapsed rock will weakly reduce the low-resistivity anomalous efect on the water-accumulated goaf.In addition,the response value of the attenuation voltage increased as the area of the transmitting coil increases,but decreased with increasing delay time and increasing background resistivity and depth of the target body.The feld detection results of the Majiliang coal mine also confrmed the theoretical analysis and the numerical simulation. 展开更多
关键词 transient electromagnetic method Water-accumulated goaf Forward and inverse simulation Attenuation curve of induced voltage
在线阅读 下载PDF
上一页 1 2 224 下一页 到第
使用帮助 返回顶部