Social development in the new era is closely inseparable from good talents,the stress of whose cultivation,in turn,can guarantee solid development of whole society.This paper investigates and analyzes aphasia phenomen...Social development in the new era is closely inseparable from good talents,the stress of whose cultivation,in turn,can guarantee solid development of whole society.This paper investigates and analyzes aphasia phenomenon of Chinese culture among non-English majors to appeal for further inheritance and advancement by means of questionnaire survey plus vocabulary test,and proposes several ways in promoting high-end talent fostering.展开更多
采用ATP/EMTP软件对猇亭地区220 k V输电线路建模,通过软件仿真,分析了避雷器安装方式及工频相位角对线路反击耐雷性能的影响。利用两者对线路反击耐雷性能的影响,提出了两种新方案,并针对雷击杆塔这种情况,仿真分析了原方案及两种新方...采用ATP/EMTP软件对猇亭地区220 k V输电线路建模,通过软件仿真,分析了避雷器安装方式及工频相位角对线路反击耐雷性能的影响。利用两者对线路反击耐雷性能的影响,提出了两种新方案,并针对雷击杆塔这种情况,仿真分析了原方案及两种新方案的反击耐雷性能及高电位转移后对相邻杆塔的影响。结果表明:方案二的反击耐雷性能好,而且高电位转移现象轻微,不威胁相邻杆塔的安全运行。展开更多
非能动安全壳冷却系统(Passive containment cooling system,PCS)是大型先进压水堆核电厂专设安全系统之一,壳外冷却水膜在事故发生后对壳内的降温降压过程有着重要的作用。为了分析LOCA(Loss of Coolant Accident)事故工况下PCS整体响...非能动安全壳冷却系统(Passive containment cooling system,PCS)是大型先进压水堆核电厂专设安全系统之一,壳外冷却水膜在事故发生后对壳内的降温降压过程有着重要的作用。为了分析LOCA(Loss of Coolant Accident)事故工况下PCS整体响应过程的主要传热现象,验证PCS设计水膜覆盖率的安全裕度,本文利用安全壳专用分析程序分别对PCS原型系统和模拟试验台架(Containment safety v Erification via integ Ral Test,CERT)进行建模,分析基准工况和恶劣工况下安全壳内的传热相关无量纲参数群((47)群)及其相似准则数((47)比)的变化,比较影响PCS降温降压能力的不同能量传递方式的重要程度,同时对其在试验台架上出现的失真度进行评价。结果表明,安全壳外冷却水膜建立后,壳内破口能量主要通过壳内壁面蒸汽冷凝和壳外壁面水膜蒸发载出,相应物理现象在台架模拟试验中应优先准确模拟;此阶段壳内热阱传热失真度较大,但由于其换热量很低可以忽略不计。通过传热特性失真评价认为,CERT试验台架可以有效模拟原型PCS在小水膜覆盖率时的传热现象。展开更多
文摘Social development in the new era is closely inseparable from good talents,the stress of whose cultivation,in turn,can guarantee solid development of whole society.This paper investigates and analyzes aphasia phenomenon of Chinese culture among non-English majors to appeal for further inheritance and advancement by means of questionnaire survey plus vocabulary test,and proposes several ways in promoting high-end talent fostering.
文摘采用ATP/EMTP软件对猇亭地区220 k V输电线路建模,通过软件仿真,分析了避雷器安装方式及工频相位角对线路反击耐雷性能的影响。利用两者对线路反击耐雷性能的影响,提出了两种新方案,并针对雷击杆塔这种情况,仿真分析了原方案及两种新方案的反击耐雷性能及高电位转移后对相邻杆塔的影响。结果表明:方案二的反击耐雷性能好,而且高电位转移现象轻微,不威胁相邻杆塔的安全运行。
文摘非能动安全壳冷却系统(Passive containment cooling system,PCS)是大型先进压水堆核电厂专设安全系统之一,壳外冷却水膜在事故发生后对壳内的降温降压过程有着重要的作用。为了分析LOCA(Loss of Coolant Accident)事故工况下PCS整体响应过程的主要传热现象,验证PCS设计水膜覆盖率的安全裕度,本文利用安全壳专用分析程序分别对PCS原型系统和模拟试验台架(Containment safety v Erification via integ Ral Test,CERT)进行建模,分析基准工况和恶劣工况下安全壳内的传热相关无量纲参数群((47)群)及其相似准则数((47)比)的变化,比较影响PCS降温降压能力的不同能量传递方式的重要程度,同时对其在试验台架上出现的失真度进行评价。结果表明,安全壳外冷却水膜建立后,壳内破口能量主要通过壳内壁面蒸汽冷凝和壳外壁面水膜蒸发载出,相应物理现象在台架模拟试验中应优先准确模拟;此阶段壳内热阱传热失真度较大,但由于其换热量很低可以忽略不计。通过传热特性失真评价认为,CERT试验台架可以有效模拟原型PCS在小水膜覆盖率时的传热现象。