期刊文献+
共找到359篇文章
< 1 2 18 >
每页显示 20 50 100
UV-radiation Dose Assessment for LR-115 Track Detector by Using UV-visible and FTIR Spectroscopy Techniques
1
作者 Hussain A.AI-Jobouri Fala Hatcm Taha 《Journal of Physical Science and Application》 2016年第1期88-91,共4页
Abstract:In the present work,studies the effect uv-radiation dose(5 J/cm2 to 360 J/cm2)with power 15 W to LR-115 track detector thickness 100μm.Absorbance-A was measured at wavelength 600 nm and 650 nm by usinguv-vis... Abstract:In the present work,studies the effect uv-radiation dose(5 J/cm2 to 360 J/cm2)with power 15 W to LR-115 track detector thickness 100μm.Absorbance-A was measured at wavelength 600 nm and 650 nm by usinguv-visible spectroscopy and measure the transmission percent--T%and deviation at the wavenumber-w2907 cm1 by using Fourier infrared--FTIR spectroscopy.The relationship between the dose of radiation to the uv-radiation(J/cm2)and the absorbance-A at wavelength 600 nm and 650 nm and the wavenumber-w 2907 cm-1 was calculate as a polynomial relation.The present study show that there is a possibility to use the detector LR-115 to assessment doses of exposure to uv-radiation in the medical and environmental fields. 展开更多
关键词 LR-115 track detector UV-IRRADIATION UV-visible spectroscopy FTIR spectroscopy SSNTDs.
在线阅读 下载PDF
Uranium Concentrations in Surface Soil Samples for Selected Regionsin AI-Anbar Governorate (Iraq) Using CR-39 Track Detector
2
作者 Nada Fadhil Tawfiq Hazim Louis Mansour Mahmood Salim Karim 《Journal of Physical Science and Application》 2016年第1期67-70,共4页
In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of... In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of induced fission tracks. The results show that, the uranium concentrations ranged from 4.61 ppm, 56.93 Bq/kg (AL-Falluja AL-Jolan District) to 1.81 ppm 22.35 Bq/kg (Anah)with an average 3.42±0.79 ppm, 41.76±9.04 Bq/kg. The present results have shown that the uranium concentrations in the studied surface soil samples were less than the allowed limit 11.7 ppm recommended by UNSCEAR, 1993. 展开更多
关键词 Uranium concentration CR-39 track detector fission tracks surface soil.
在线阅读 下载PDF
Measurement of Radon Gas Concentrations in Tap Water Samples for Thi-Qar Governorate Using Nuclear Track Detector (CR-39)
3
作者 Liath Ahmed Najam Hazim Louis Mansour +1 位作者 Nada Fadhil Tawfiq Mahmood Salim Karim 《Detection》 2016年第1期1-8,共8页
In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (... In the present work, we have measured the radon gas concentrations in tap water samples are taken directly from drinking tap water in sites houses being carried in Thi-Qar governorate by using nuclear track detector (CR-39). The results of measurements have shown that the highest average radon concentration in water samples is found in AL-Refai region which is equal to (0.223 ± 0.03 Bq/L), while the lowest average radon gas concentration is found in AL-Fajr region which is equal to (0.108 ± 0.01 Bq/L), with an average value of (0.175 ± 0.03 Bq/L). The highest value of annual effective dose (AED) in tap water samples is found in AL-Refai region, which is equal to (0.814 μSv/y), while the lowest value of (AED) is found in AL-Fajr region which is equal to (0.394 μSv/y), with an average value of (0.640 ± 0.1 μSv/y). The present results have shown that radon gas concentrations in tap water samples are less than the recommended international value (11.1 Bq/L). There for tap water in all the studied sites in Thi-Qar governorate is safe as for as radon concentration being concerned. 展开更多
关键词 RADON Solid State Nuclear track detectors CR-39 Radon in Water
在线阅读 下载PDF
Microstructural Investigation of PM-355 Nuclear Track Detector Subjected to Low-Dose Gamma Irradiation: A Positron Annihilation Lifetime Study 被引量:1
4
作者 Emad Hassan Aly 《Materials Sciences and Applications》 2013年第10期622-629,共8页
Samples of the PM-355 polymeric solid state nuclear track detector were exposed to low gamma absorbed doses from 1 kGy (0.1 Mrad) up to 9 kGy (0.9 Mrad). Positron annihilation lifetime (PAL) in conjunction with transm... Samples of the PM-355 polymeric solid state nuclear track detector were exposed to low gamma absorbed doses from 1 kGy (0.1 Mrad) up to 9 kGy (0.9 Mrad). Positron annihilation lifetime (PAL) in conjunction with transmission electron microscopy (TEM) and Thermo-gravimetric analysis (TGA) were performed on irradiated and pristine samples at room temperature. The observed lifetime spectra were resolved into three components where the ortho-positronium (o-Ps) lifetime component was associated with the pick-off annihilation of positronium trapped by the free volume. PAL studies of irradiated PM-355 samples showed that ortho-positronium (o-Ps) lifetime increases with an increase in dose up to 4 kGy and decreases at higher doses. In contrast, the intensity of the o-Ps component, I3, decreases with the dose up to about 2 kGy, followed by a much smooth decrease up to 7 kGy, and then it levels off. TGA analysis indicated that the PM-355 detector decomposed in one main breakdown stage. These results are discussed on the basis of chemical and physical changes occurring at the microscopic level in the PM-355 due to irradiation. Crosslinking dominates for doses between 1 and 4 kGy, while the degradation mechanism (Chain scission) prevails for doses up to 9 kGy. 展开更多
关键词 POSITRON ANNIHILATION LIFETIME Nuclear track detector TEM Gamma DOSE TGA
暂未订购
^238U and^232Th concentrations measured in different medical drugs by using solid-state nuclear track detectors and resulting radiation doses to the skin of patients
5
作者 m.a.misdaq a.matrane 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第3期11-22,共12页
Urban populations in Morocco receive free medical drugs as prescribed by doctors in district health centres.To explore the exposure pathway of ^(238)U and^(232)Th and their decay products on the skin of patients,these... Urban populations in Morocco receive free medical drugs as prescribed by doctors in district health centres.To explore the exposure pathway of ^(238)U and^(232)Th and their decay products on the skin of patients,these radionuclides were measured in various medical drugs by using solid-state nuclear track detectors(SSNTDs).The measured concentrations range of ^(238)U and ^(232)Th in the medical drug samples of interest vary from(4.3±0.3) to(11.1±0.7) mBq 1^(-1) and(0.49±0.03) to(1.3±0.1)mBq 1^(-1),respectively.A new dosimetric model,based on the concept of specific alpha-dose and alpha-particle residual energy,was developed for evaluating radiation doses to skin following the application of different medical drugs by patients.The maximum total equivalent effective dose to skin due to the ^(238)U and ^(232)Th series from cutaneous application of different medical drugs by patients was found to be 2.8 mSv year^(-1) cm^(-2). 展开更多
关键词 固体核径迹探测器 药物应用 辐射剂量 皮肤 患者 浓度测定 放射性核素 城市人口
暂未订购
The Effect of (x-Radiation Dose on CR-39 Polymer Track Detectors Using Positron Annihilation Lifetime and UV-Spectroscopy
6
作者 Mostafa Fawzy Eissa Esmat Mohamed Hassan Emad A. Badawi 《材料科学与工程(中英文版)》 2010年第11期48-52,共5页
关键词 正电子湮没寿命谱 光谱探测器 剂量效应 CR X射线 紫外线 聚合物 跟踪
在线阅读 下载PDF
Determination of Alpha Particles Concentration in Toothpaste Using CR-39 Track Detector
7
作者 Fouad A. Majeed Inaam H. Kadhim +1 位作者 Ali O. Muhsen Khalid H. Abass 《Detection》 2015年第2期9-13,共5页
The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi m... The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples. 展开更多
关键词 ALPHA CONCENTRATION CR-39 detector FISSION track Technique TOOTHPASTE
暂未订购
Nuclear Track Detectors for Relativistic Nuclear Fragmentation Studies: Comparison with Other Competitive Techniques
8
作者 Mukhtar Ahmed Rana Gul Sher +2 位作者 Shahid Manzoor Fariha Malik Kanwal Naz 《Modern Instrumentation》 2013年第3期49-59,共11页
The potential of the high resolution nuclear track detector (NTD) CR-39 is examined carefully for the measurement of relativistic nuclear projectile fragmentation cross sections and studies of related processes using ... The potential of the high resolution nuclear track detector (NTD) CR-39 is examined carefully for the measurement of relativistic nuclear projectile fragmentation cross sections and studies of related processes using the experience of many years of such measurements. The charge resolution and the charge resolving power of CR-39 detectors for the measurements of 158 A GeV 207Pb projectiles and their fragments are presented. Exposures of target-detector stacks, the chemical etching procedure and the nuclear track measurements are described in detail discussing precautions and possible errors. The procedures discussed are also valid for other NTDs. A comparison with electronic active detectors is also made considering important detection and measurement aspects. An experimental design proposing the co-use of NTDs with in-use active detectors is described. 展开更多
关键词 NUCLEAR track Detection Methodology (NTDM) CR-39 detectors NUCLEAR FRAGMENTATION Charge Resolution FRAGMENTATION Cross SECTIONS
在线阅读 下载PDF
Analysis of Nuclear Track Parameters of CN-85 Detector Irradiated to Thermal Neutrons by Using MATLAB Program 被引量:1
9
作者 Hussain A. Al-Jobouri Mustafa Y. Rajab Laith A. Najam 《Detection》 2015年第4期29-36,共8页
CN-85 detector which covered with boric acid H3Bo3 pellete has been irradiated by thermal neutrons from (241Am-9Be) source with activity 12 Ci and neutron flux 105 n. cm-2. s-1. The irradiation times-TD for detector w... CN-85 detector which covered with boric acid H3Bo3 pellete has been irradiated by thermal neutrons from (241Am-9Be) source with activity 12 Ci and neutron flux 105 n. cm-2. s-1. The irradiation times-TD for detector were 4 h, 8 h, 16 h and 24 h. The track detector has been etched with sodium hydroxide. After chemical etching of the irradiated CN-85 detector, the images have been taken from a digital camera connected to the optical microscope. Image processing for the output images has been performed using MATALB program, and these images were analyzed and we had found the following relations: a) The relation between summation of opened track or surface density for tracks (intensity-IT) varies with radius of opening (track radius-RT). b) The relation between the tracks number-NT varies with the tracks diameter-DT (in micrometer) and tracks area-AT. That analysis of image processing was obtained, and the track intensity-IT was decreased with increase of track radius-RT at all of the irradiation time-TD. And the track intensity-IT was increased with increasing irradiation time-TD (h) for different track radius-RT (0.4225, 0.845, 1.2675 and 1.69 μm). The study indicates the possibility of using the analysis of image processing to CN-85 detector for classification of α-particle emitters through limitation of radius of track-RT, in addition to the contribution of these techniques in preparation of nano-filters and nono-membrane in nanotechnology fields. 展开更多
关键词 NUCLEAR track detectors Thermal NEUTRON MATLAB PROGRAM Image Processing
暂未订购
Optical Properties of CR-39 Track Etch Detectors Irradiated by Alpha Particles with Different Energies
10
作者 Mostafa Fawzy Eissa 《材料科学与工程(中英文版)》 2011年第1期26-31,共6页
关键词 径迹探测器 光学特性 径迹蚀刻 粒子辐照 能量通量 CR 阿尔法 光学性质
在线阅读 下载PDF
A New Method to Determine the Maximum Value of the Track Length of Alpha Particle in CR-39 Detector
11
作者 Hussein A. Ahmed A. Mohammed A. Said Ahmad 《Materials Sciences and Applications》 2015年第2期145-151,共7页
The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the ... The aim of this paper is to determine the maximum values of the track length (Lmax) of alpha particles in Nuclear Track Detector (type CR-39) using a new method by taking the relation between the etching time and the diameter square of alpha particle with different energies at constant bulk etch rate VB (1.45 μm/hr) by using TRACK_TEST program from Brun et al. function and Yu et al. function. Using the new equation, the maximum values of the track lengths of alpha particles measured in CR-39 detector have been found to be in a good agreement with the values measured by using Brun et al. function and Yu et al. function in TRACK_TEST program. 展开更多
关键词 Maximum Value of track LENGTH CR-39 Range of ALPHA Particle Nuclear track detector (NTD)
暂未订购
高能激光系统靶上跟踪精度测试影响因素研究
12
作者 张春仙 解一文 +3 位作者 李松山 唐晓军 王钢 刘磊 《激光与红外》 北大核心 2026年第1期50-53,共4页
靶上跟踪精度是评价高能激光系统作用效能的重要指标,高能激光系统跟踪精度一般在微弧级,对测试设备精度等提出了较高的要求。本文首先分析研究了测试设备、测试环境等测试条件对测试结果的影响,其次基于以上分析提出了提高测试精度的措... 靶上跟踪精度是评价高能激光系统作用效能的重要指标,高能激光系统跟踪精度一般在微弧级,对测试设备精度等提出了较高的要求。本文首先分析研究了测试设备、测试环境等测试条件对测试结果的影响,其次基于以上分析提出了提高测试精度的措施,最后分析计算了跟踪精度测试合成不确定度的构成。 展开更多
关键词 高能激光系统 阵列探测法 靶上跟踪精度
在线阅读 下载PDF
Simulation study of BESⅢwith stitched CMOS pixel detector using AcTs 被引量:1
13
作者 Yi Liu Xiao‑Cong Ai +17 位作者 Guang‑Yan Xiao Ya‑Xuan Li Ling‑Hui Wu Liang‑Liang Wang Jia‑Ning Dong Ming‑Yi Dong Qing‑Lin Geng Min Luo Yan Niu An‑Qing Wang Chen‑Xu Wang Meng Wang Lei Zhang Liang Zhang Rui‑Kai Zhang Yao Zhang Ming‑Gang Zhao Yang Zhou 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期264-270,共7页
The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperim... The reconstruction of the tracks of charged particles with high precision is crucial for HEP experiments to achieve their physics goals.The BESⅢdrift chamber,which is used as the tracking detector of the BESⅢexperiment,has suffered from aging effects resulting in degraded tracking performance after operation for approximately 15 years.To preserve and enhance the tracking performance of BESⅢ,one of the proposals is to add one layer of a thin cylindrical CMOS pixel sensor based on state-of-the-art stitching technology between the beam pipe and the drift chamber.The improvement in the tracking performance of BESⅢwith such an additional pixel detector compared to that with only the existing drift chamber was studied using the modern common tracking software Acts,which provides a set of detector-agnostic and highly performant tracking algorithms that have demonstrated promising performance for a few high-energy physics and nuclear physics experiments. 展开更多
关键词 BESⅢtracking detector CMOS pixel sensor track reconstruction Common tracking software
在线阅读 下载PDF
Determination the Effect of Gamma Radiation and Thermal Neutron on PM-355 Detector by Using FTIR Spectroscopy
14
作者 Hussain Ali Al-Jobouri 《Detection》 2015年第3期15-20,共6页
The effect of gamma on nuclear track detector type PM-355 (at the dose range 200 to 1600 kGy) and thermal neutron (flux 105 n·cm-2·s-1) was calculated by using of two irradiation methods. First method (G + N... The effect of gamma on nuclear track detector type PM-355 (at the dose range 200 to 1600 kGy) and thermal neutron (flux 105 n·cm-2·s-1) was calculated by using of two irradiation methods. First method (G + N) was an irradiation PM-355 detector by gamma radiation and then irradiation by thermal neutrons, and another method (N + G) was irradiated by thermal neutrons and then gamma radiation. FTIR-spectroscopy was used to measure the change in deferent of transmission percent ΔT% at the wavenumber 1260 cm-1 with wavenumber 2962 cm-1 [ΔT%]1260-2962 and wavenumber 1138 cm-1 [ΔT%]1260-1138. The values of [ΔT%]1260-2962 and [ΔT%]1260-1138 were increasing with the increase of gamma irradiation with maximum response at 820 kGy and then drop after this dose until to 1600 kGy. This study determined the linear equations relation between the effect of gamma radiation on PM-355 detector and the change of [ΔT%]1260-2962 and [ΔT%]1260-1138, and this change appeared in (N + G) irradiation method better than in (G + N) irradiation method. The appearance of wavenumber 2964 cm-1 in (G + N) irradiation method referred to alkyl asymmetry C-H bond stretched out of skelated plane after changes in chemical structure of PM-355 detector by gamma or neutrons radiation. 展开更多
关键词 PM-355 NUCLEAR track detectors GAMMA Radiation Thermal NEUTRON FTIR-SPECTROSCOPY
暂未订购
北山地下实验室场区及周边环境空气氡浓度水平调查研究 被引量:1
15
作者 夏子通 凌辉 +1 位作者 范文哲 贺三军 《世界核地质科学》 2025年第1期146-154,共9页
采用径迹法对北山地下实验室场区和周边区域的空气氡浓度进行为期一年的调查,查明区域的氡浓度本底水平,分析人为活动和气象因素对氡浓度的影响。结果表明,区域空气氡浓度范围介于10~64 Bq·m^(-3)之间,平均值为27 Bq·m^(-3),... 采用径迹法对北山地下实验室场区和周边区域的空气氡浓度进行为期一年的调查,查明区域的氡浓度本底水平,分析人为活动和气象因素对氡浓度的影响。结果表明,区域空气氡浓度范围介于10~64 Bq·m^(-3)之间,平均值为27 Bq·m^(-3),场区外、科研管理区和运行维护区的氡浓度水平差异较小,人为活动对区域氡浓度的影响较为有限;根据皮尔逊相关系数分析结果,氡浓度与温度呈正相关,不同季节的氡浓度差异与温度相关性分析结果一致;风速对氡浓度的影响较为复杂,两者没有表现出明显的相关性。本研究为北山地下实验室的氡气长期监测及健康风险评估提供数据支撑和经验反馈。 展开更多
关键词 北山地下实验室 皮尔逊相关系数 花岗岩 固体径迹法
在线阅读 下载PDF
Comparative Alpha Tracks Counting Using an Optical Microscope and a Spark Counter
16
作者 Dabo S. I. Agba Ponaho Kezo Issa Konaté 《Detection》 2023年第2期7-18,共12页
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ... In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements. 展开更多
关键词 LR 115 detector Optical Microscope Spark Counter Alpha track Density Calibration Factor Radon Concentration
在线阅读 下载PDF
基于新型深层钻井型缪子探测器的缪子透射成像研究
17
作者 尹隆乡 罗思远 +7 位作者 曾国强 王克 冯松 冯胜洋 张海峰 冯春添 廖伶元 王晓冬 《核电子学与探测技术》 北大核心 2025年第1期37-46,共10页
缪子透射成像是一种通过测量宇宙射线缪子在穿过物体前后的通量变化来揭示其内部密度结构的技术。其非接触、无损的特点适用于对大型物体进行远距离成像,广泛应用于火山监测、考古、地下结构调查及矿产勘探等领域。目前,在矿产勘探应用... 缪子透射成像是一种通过测量宇宙射线缪子在穿过物体前后的通量变化来揭示其内部密度结构的技术。其非接触、无损的特点适用于对大型物体进行远距离成像,广泛应用于火山监测、考古、地下结构调查及矿产勘探等领域。目前,在矿产勘探应用中的一项挑战为设计出适应于深层钻井的探测器。该类型探测器要求在尽量减少读出电子学通道数量的前提下,在约500~800米深度保持良好成像质量。为解决上述技术难题,本文基于现有研究设计了一种新型钻井型缪子探测器,并利用制作的简化版物理模型进行了初步模拟与实验。使用蒙特卡罗GEANT4程序对探测器模型的角度分辨率进行了模拟研究,设计出缪子径迹算法,并利用该模型模拟探测天然缪子源。后续通过与该简化探测器实验结果的比较分析以验证该模型的可靠性,并针对大体积高Z物质进行了模拟成像。研究表明,该探测器模型可有效模拟缪子击中物体时SiPM的信号采集过程,所设计的缪子径迹算法能够准确计算缪子的入射方向(方位角分辨率2.41°,天顶角分辨率3.01°)。该简化探测器可实现对大体积高Z物质的探测,模拟结果可为实验提供参考依据。 展开更多
关键词 蒙特卡罗模拟 GEANT4 缪子成像 缪子径迹探测器
在线阅读 下载PDF
CR-39探测器中α粒子与质子的甄别方法
18
作者 张琪 宋玉收 +1 位作者 曹勤剑 卫晓峰 《哈尔滨工程大学学报》 北大核心 2025年第11期2233-2241,共9页
针对空间站辐射监测中CR-39探测器无法有效区分α粒子与质子而导致个人剂量评估偏差大的问题,为实现粒子的精准甄别,本文采用Geant4工具包与Track程序开展模拟研究。依据径迹蚀刻动力学理论,利用Geant4模拟粒子输运物理过程,并通过Trac... 针对空间站辐射监测中CR-39探测器无法有效区分α粒子与质子而导致个人剂量评估偏差大的问题,为实现粒子的精准甄别,本文采用Geant4工具包与Track程序开展模拟研究。依据径迹蚀刻动力学理论,利用Geant4模拟粒子输运物理过程,并通过Track程序模拟化学蚀刻与径迹形貌演化;系统研究了1~10 MeV能量范围内α粒子与质子在CR-39中的射程、阻止本领及径迹参数,并确定了最佳蚀刻条件。模拟结果表明,相同能量下α粒子射程仅为质子的1/4.5~1/10.5,阻止本领高达3.7~5.5倍;在相同蚀刻条件下,两者径迹形态差异显著,α粒子径迹呈黑色圆形,而质子径迹为灰色圆形,且前者的直径与深度均显著大于后者。本文建立了基于Geant4与Track的CR-39全流程模拟方法,实现了α粒子与质子的有效甄别,为解决空间辐射剂量监测中的粒子区分难题提供了关键理论依据和技术支持。 展开更多
关键词 空间辐射 固体核径迹探测器 CR-39 α/质子甄别 化学蚀刻 Geant4仿真 阻止本领 track模拟 径迹形态
在线阅读 下载PDF
一种单独测定低能中子累积剂量方法的初步探讨
19
作者 邓磊 曹发明 +2 位作者 王哲 涂彧 周宁 《中国辐射卫生》 2025年第4期578-583,共6页
目的研究一种基于CR-39探测器单独测定低能中子(<100 keV)累积剂量的方法。方法根据径迹蚀刻动力学理论,分析BN+CR-39探测器在受宽能谱中子照射后,与低能中子和快中子分别作用形成径迹的差异,提出在特定蚀刻条件下,可识别低能中子产... 目的研究一种基于CR-39探测器单独测定低能中子(<100 keV)累积剂量的方法。方法根据径迹蚀刻动力学理论,分析BN+CR-39探测器在受宽能谱中子照射后,与低能中子和快中子分别作用形成径迹的差异,提出在特定蚀刻条件下,可识别低能中子产生的径迹同时避开快中子径迹干扰的方法。结果通过实验得出,BN+CR-39探测器(实验采用TASTRAK PADC型CR-39径迹片)在6.25 mol/L NaOH溶液中蚀刻1 h,可独立读取低能中子的径迹;其径迹密度与低能中子的周围剂量当量呈现出良好的线性关系,刻度系数为0.0366μSv·tr^(-1)·cm^(2)。结论本研究采用的BN+CR-39探测器对低能中子响应具有高灵敏度;所采用的径迹识别方法可有效用于低能中子剂量累积剂量当量的单独测定。 展开更多
关键词 固体核径迹探测器 低能中子 径迹蚀刻动力学 周围剂量当量
原文传递
400 A MeV能区核碰撞电荷拾取反应截面与射弹核质量的关系
20
作者 李蓉 张东海 《中北大学学报(自然科学版)》 2025年第6期800-807,共8页
本文利用CR-39固体核径迹探测器对400 A MeV能区范围内的^(12)C、^(40)Ar、^(56)Fe、^(84)Kr射弹分别作用于Al、 C、 CH_(2)靶的电荷拾取反应截面进行了实验研究,探索在400 A MeV能区重离子电荷拾取反应截面与射弹核大小的依赖关系,为... 本文利用CR-39固体核径迹探测器对400 A MeV能区范围内的^(12)C、^(40)Ar、^(56)Fe、^(84)Kr射弹分别作用于Al、 C、 CH_(2)靶的电荷拾取反应截面进行了实验研究,探索在400 A MeV能区重离子电荷拾取反应截面与射弹核大小的依赖关系,为此能区的电荷拾取反应机制研究提供实验依据。通过分别利用幂函数和线性函数关系式拟合电荷拾取反应截面与射弹核质量的数据关系,发现幂函数的幂次拟合参数b在-0.01~0.71之间,这种对于射弹核质量A_(P)的依赖关系,与在更高束流能量更重射弹核观察到的结果不同;线性函数的斜率拟合参数β在-0.004~0.24之间,此结果在一定程度上证实电荷拾取反应过程应为边缘及表面反应过程的集体贡献。 展开更多
关键词 中高能核-核碰撞 电荷拾取反应截面 CR-39核径迹探测器
在线阅读 下载PDF
上一页 1 2 18 下一页 到第
使用帮助 返回顶部