Transmission tower-line systems(TTLSs)play a crucial role in the long-distance transmission of electrical energy,often necessitating their crossing through active fault areas.However,previous studies have given limite...Transmission tower-line systems(TTLSs)play a crucial role in the long-distance transmission of electrical energy,often necessitating their crossing through active fault areas.However,previous studies have given limited attention to the seismic performance of fault-crossing transmission TTLSs,particularly in terms of considering the impact of permanent ground motion displacements(PGMDs).This study attempts to address this concern by evaluating the seismic performance of TTLSs exposed to fault earthquakes.Three strike-slip ground motions are carefully selected,and the corresponding PGMDs are accurately replicated through baseline adjustment.A meticulously designed and fabricated reduced-scale experimental model of a TTLS is then employed to investigate the influence of the fault crossing location(FCL)on its seismic performance.The shake table tests conducted unequivocally demonstrate that PGMDs significantly amplify the seismic responses of the TTLS and identify the most unfavorable FCL.Furthermore,a finite element model(FEM)is developed and its accuracy is validated by comparing it with the experimental results.Parametric analyses are conducted to explore the effects of fault crossing angles(FCAs)and PGMD amplitudes on the seismic performances of TTLSs.This study is expected to contribute valuable insights for the seismic design and performance analysis of TTLSs crossing fault areas.展开更多
Collapses of transmission towers were often observed in previous large earthquakes such as the Chi-Chi earthquake in Taiwan and Wenchuan earthquake in Sichuan,China. These collapses were partially caused by the pullin...Collapses of transmission towers were often observed in previous large earthquakes such as the Chi-Chi earthquake in Taiwan and Wenchuan earthquake in Sichuan,China. These collapses were partially caused by the pulling forces from the transmission lines generated from out-of-phase responses of the adjacent towers owing to spatially varying earthquake ground motions. In this paper,a 3D finite element model of the transmission tower-line system is established considering the geometric nonlinearity of transmission lines. The nonlinear responses of the structural system at a canyon site are analyzed subjected to spatially varying ground motions. The spatial variations of ground motion associated with the wave passage,coherency loss,and local site effects are given. The spatially varying ground motions are simulated stochastically based on an empirical coherency loss function and a filtered Tajimi-Kanai power spectral density function. The site effect is considered by a transfer function derived from 1D wave propagation theory. Compared with structural responses calculated using the uniform ground motion and delayed excitations,numerical results indicate that seismic responses of transmission towers and power lines are amplified when considering spatially varying ground motions including site effects. Each factor of ground motion spatial variations has a significant effect on the seismic response of the structure,especially for the local site effect. Therefore,neglecting the earthquake ground motion spatial variations may lead to a substantial underestimation of the response of transmission tower-line system during strong earthquakes. Each effect of ground motion spatial variations should be incorporated in seismic analysis of the structural system.展开更多
A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlineari...A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures.展开更多
基金Shandong Provincial Natural Science Foundation for Distinguished Young Scholars under Grant No.ZR2022JQ27the Taishan Scholars Program
文摘Transmission tower-line systems(TTLSs)play a crucial role in the long-distance transmission of electrical energy,often necessitating their crossing through active fault areas.However,previous studies have given limited attention to the seismic performance of fault-crossing transmission TTLSs,particularly in terms of considering the impact of permanent ground motion displacements(PGMDs).This study attempts to address this concern by evaluating the seismic performance of TTLSs exposed to fault earthquakes.Three strike-slip ground motions are carefully selected,and the corresponding PGMDs are accurately replicated through baseline adjustment.A meticulously designed and fabricated reduced-scale experimental model of a TTLS is then employed to investigate the influence of the fault crossing location(FCL)on its seismic performance.The shake table tests conducted unequivocally demonstrate that PGMDs significantly amplify the seismic responses of the TTLS and identify the most unfavorable FCL.Furthermore,a finite element model(FEM)is developed and its accuracy is validated by comparing it with the experimental results.Parametric analyses are conducted to explore the effects of fault crossing angles(FCAs)and PGMD amplitudes on the seismic performances of TTLSs.This study is expected to contribute valuable insights for the seismic design and performance analysis of TTLSs crossing fault areas.
基金Project supported by the National Natural Science Foundation of China (No. 50638010)the Specialized Research Fund for the Doctoral Program of Higher Education of China (No. 20070141036)
文摘Collapses of transmission towers were often observed in previous large earthquakes such as the Chi-Chi earthquake in Taiwan and Wenchuan earthquake in Sichuan,China. These collapses were partially caused by the pulling forces from the transmission lines generated from out-of-phase responses of the adjacent towers owing to spatially varying earthquake ground motions. In this paper,a 3D finite element model of the transmission tower-line system is established considering the geometric nonlinearity of transmission lines. The nonlinear responses of the structural system at a canyon site are analyzed subjected to spatially varying ground motions. The spatial variations of ground motion associated with the wave passage,coherency loss,and local site effects are given. The spatially varying ground motions are simulated stochastically based on an empirical coherency loss function and a filtered Tajimi-Kanai power spectral density function. The site effect is considered by a transfer function derived from 1D wave propagation theory. Compared with structural responses calculated using the uniform ground motion and delayed excitations,numerical results indicate that seismic responses of transmission towers and power lines are amplified when considering spatially varying ground motions including site effects. Each factor of ground motion spatial variations has a significant effect on the seismic response of the structure,especially for the local site effect. Therefore,neglecting the earthquake ground motion spatial variations may lead to a substantial underestimation of the response of transmission tower-line system during strong earthquakes. Each effect of ground motion spatial variations should be incorporated in seismic analysis of the structural system.
基金Research Fund of Chinese State Grid Company (No.SGKJ[2007]413)
文摘A macroscopic finite element modeling approach was proposed to calculate the vibration of a tower-line system subjected to broken wires with software ANSYS/LS-DYNA. In the finite element model, not only the nonlinearity of wires and suspension insulators are considered, but also the support towers are included. The incremental and iterative approaches are combined by applying the unbalanced loads incrementally during each iteration cycle. The approach was illustrated with an example of a Hanjiang- River long-span transmission line system subjected to a shield wire and a conductor failure, respectively. The analysis results showed that the proposed dynamic simulation approach can demonstrate the kinetic process of the tower-line system subjected to wire ruptures: The frequencies of line components were lower and densely distributed, but the frequencies of tower components were higher and sparsely distributed. Anyhow, the dynamic effects of wire ruptures on tower-line system could not be ignored in analysis of tower-line system subjected wire failures.