期刊文献+
共找到1,587篇文章
< 1 2 80 >
每页显示 20 50 100
CLINICAL COMPARISION OF THE TREATMENT OF CERVICAL PROLAPSE OF INTERVERTEBRAL DISC BY USING CAGE OR TITANIUM PLATE
1
作者 杨佩 王坤正 +2 位作者 宫福良 王春生 时志斌 《Journal of Pharmaceutical Analysis》 SCIE CAS 2006年第1期86-89,共4页
Objective To compare the clinical effects of treating cervical prolapse of intervertebral disc by using Solis cage, titanium cage and autogenous iliac crest graft (AICG) combined with titanium plate. Methods 64 cases ... Objective To compare the clinical effects of treating cervical prolapse of intervertebral disc by using Solis cage, titanium cage and autogenous iliac crest graft (AICG) combined with titanium plate. Methods 64 cases of cervical prolapse of intervertebral disc were analyzed retrospectively. All the patients were followed up for about one year. Group A is composed of 20 patients (30 intervertebral spaces) treated with microdiscectomy and Solis cage fusion; group B is composed of 21 patients(22 intervertebral spaces) treated with titanium cage and group C is involved of 23 patients(28 intervertebral spaces) which were dealt with AICG combined with titanium plate. The differences in the total X ray exposure time, time working on iliac bone, incidence of complications, fusion rate, incidence of JOA score recovery rate more than 50% and rehabilitation time of the three groups are analyzed. Results All indexes from group A and B were more satisfactory than those from group C (P<0.05). The statistic analysis results of the incidence of complications of cervical part, rehabilitation time in group A are 5.0±1.8, 5.1±1.2; and that is 14.3±2.6, 7.5 ±1.6 and 26.1±6.2, 8.6±2.3 in group B and group C respectively. There is significant difference between group A and group B on the incidence of complications of cervical part and rehabilitation time (P<0.05). Results of the incidence of JOA score recovery rate >50% in group A(95.8±3.2) was more satisfactory than that in group B(93.6±2.9), while there was no statistical difference between group A and group B (P>0.05). Conclusion The Solis cage is better in treating the cervical prolapse of intervertebral disc than other ways. Also, it makes the operation easier, rehabilitation time shorter, and it causes fewer complications. 展开更多
关键词 cervical prolapse of intervertebral disc cage titanium plate
暂未订购
Comparison of microstructure and mechanical properties of titanium/ steel composite plates by two manufacturing processes 被引量:8
2
作者 Xuan Yang Chang-gen Shi +1 位作者 Yu-heng Ge Md Nahid Hasan Sabuj 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2018年第3期347-356,共10页
Two types of titanium/steel composite plates with the same thickness were manufactured by parallel explosive welding and double vertical explosive welding and rolling, respectively. The comparative analysis of microst... Two types of titanium/steel composite plates with the same thickness were manufactured by parallel explosive welding and double vertical explosive welding and rolling, respectively. The comparative analysis of microstructure showed that the interface of double vertical explosive welding plate (B plate) tended to be straight while the interface of parallel explosive welding plate (A plate) was wavy bonding. Defects near the interface of B plate were extruded, and the thickness of the diffusion layer of B plate was thicker under the effects of preheating temperature and press-working. Comparative tests of mechanical properties indicated that the tensile shear strength of B plate was lower while its micro-hardness was higher. Specimens of these two types of plates were neither separated nor cracked after bending up to 180° in the three-point bending test. From the microstructural observation of tensile fracture characteristics, A plate had strong toughness fracture while B plate had mainly ductile fracture with cleavage fracture as the supplement. Macroscopically, the tensile strength of the latter was 7.9% less than that of the former. However, both satisfied the Chinese standard of tensile strength. 展开更多
关键词 Double vertical explosive welding Hot rolling Parallel explosive welding titanium/steel composite plate Microstructure Mechanical property
原文传递
Manufacturing Technology and Application Trends of Titanium Clad Steel Plates 被引量:29
3
作者 Hang SU Xiao-bing LUO +3 位作者 Feng CHAI Jun-chang SHEN Xin-jun SUN Feng LU 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2015年第11期977-982,共6页
Some of the major manufacturing processes and corresponding mechanical properties of titanium clad steel plates were analyzed, and the consequences of research, manufacturing, and application of titanium clad steel pl... Some of the major manufacturing processes and corresponding mechanical properties of titanium clad steel plates were analyzed, and the consequences of research, manufacturing, and application of titanium clad steel plates in both markets of China and overseas were also summarized. As an economical and environmentally friendly technology, the roll bonding process is expected to become the next-generation mainstream process for the manufacturing of titanium clad steel plate. Some of the crucial and most important technical problems of this particular process, including vacuum sealing technology, surface treatment process technology, application of a transition layer, and rolling process, were discussed along with the advantageous mechanical properties and life-cycle economy of these plates processed by this technology. Finally, the market needs, application trends, and requirements of titanium clad steel plate were also considered from industries of petrochemical, shipbuilding, marine, and electric power. 展开更多
关键词 titanium clad steel plate manufacturing technology application trend petrochemical rolling marine
原文传递
Microstructure and properties of nitrided layer of titanium plate,produced by simultaneous laser quenching and liquid-nitrogen cryogenics 被引量:1
4
作者 YAO QuanTong TIAN Chen +2 位作者 SUN Jian ZUO Liang TONG WeiPing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2018年第12期1901-1906,共6页
In the present study, titanium plate was treated by a novel method of laser quenching, simultaneously combined with liquidnitrogen cryogenics(LQLNC). The microstructure and properties of the titanium plate after treat... In the present study, titanium plate was treated by a novel method of laser quenching, simultaneously combined with liquidnitrogen cryogenics(LQLNC). The microstructure and properties of the titanium plate after treatment were investigated by X-ray diffraction, scanning electron microscopy, energy dispersive spectrometry, Vickers hardness testing, and friction wear testing.The results show that the treated titanium plate is covered by a nitrided layer with a homogeneous thickness of about 60 μm,while the nitrided layer consists of Ti N and α-Ti phases. Compared to general laser quenching, the LQLNC treatment increases the hardness and wear resistance of the surface-modified layer of the titanium plate. As a result of grain refinement in the nitrided layer, the cracking induced by the rapid solidification of the conventional laser-quenching process has also been effectively solved. 展开更多
关键词 laser QUENCHING liquid nitrogen titanium plate HARDNESS WEAR resistance
原文传递
Study on the interface of direct hot rolling titanium-clad steel plates 被引量:10
5
作者 SUN Jifeng LIANG Xiaojun JIAO Sihai 《Baosteel Technical Research》 CAS 2017年第1期32-39,共8页
In this study,the interface characteristics of a direct hot rolling titanium-clad steel plate were analyzed, and the mechanism of interface cracking was explored. The detrimental effect from the formation of TiFe ,TiC... In this study,the interface characteristics of a direct hot rolling titanium-clad steel plate were analyzed, and the mechanism of interface cracking was explored. The detrimental effect from the formation of TiFe ,TiC,and a Si-enriched layer on the bonding strength was clarified, and an industrial-scaled titanium-clad steel plate with shear strength over 200 MPa was produced with a carefully set schedule accordingly. It was found that hot rolling titanium-clad steel plates had a flat interface without obvious cracks. In the rolling process,both Ti and Fe atoms interdiflhsed,but Fe difthsed much faster than Ti. The Fe-diffused area consisted of three regions. After a high temperature heat treatment, the diffusion depth of Fe and Ti elements increased significantly and evident Si segregation and TiFe layers were identified. Thermal cracking initiated in the Si segregation layer and then propagated along the TiFe layer and Fe-diffused layer on the titanium side. 展开更多
关键词 titanium-clad steel plate INTERFACE DIFFUSION heat treatment
在线阅读 下载PDF
High-temperature deformation behavior of titanium clad steel plate 被引量:1
6
作者 Shang-Wu Zeng Ai-Min Zhao +3 位作者 Hai-Tao Jiang Xiao-Qian Yan Ji-Xiong Liu Xiao-Ge Duan 《Rare Metals》 SCIE EI CAS CSCD 2015年第11期764-769,共6页
In this paper, the single-pass hot compression experiment of titanium clad steel plate was carried out by Gleeble-3500 thermal mechanics simulation test machine,and the effect of deformation temperature(T), strain ra... In this paper, the single-pass hot compression experiment of titanium clad steel plate was carried out by Gleeble-3500 thermal mechanics simulation test machine,and the effect of deformation temperature(T), strain rate(ε),thickness ratio(k), and friction coefficient(l) on flow pattern of the metal and stress in the deformation zone was analyzed.The results show that the metal flow behavior and the stress during compressive deformation depend strongly on the deformation temperature. At 800 and 850 °C, the bimetal can flow uniformly, while at 900 °C, the TA2 flows faster than Q235 B, and the phenomenon of TA2 wrapping Q235 B is observed. The metal flow of the bimetal material will coordinate each other through the bonding interface. It is noted that the stress increases with the increase of the ε and l and decreases when the metal flows along the contact area. 展开更多
关键词 titanium clad steel plate Hot deformation simulati
原文传递
Low cycle fatigue behavior of zirconium−titanium−steel composite plate 被引量:1
7
作者 Bin-bin ZHOU Peng YU +3 位作者 Le CHANG Chang-yu ZHOU Cheng YE Bo-jun ZHANG 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2022年第5期1530-1547,共18页
The low cycle fatigue behavior of zirconium−titanium−steel composite plate under symmetrical and asymmetric stress control was studied.The effects of mean stress and stress amplitude on cyclic deformation,ratcheting e... The low cycle fatigue behavior of zirconium−titanium−steel composite plate under symmetrical and asymmetric stress control was studied.The effects of mean stress and stress amplitude on cyclic deformation,ratcheting effect and damage mechanism were discussed in detail.The results show that under symmetric stress control,the forward ratcheting deformation is observed.Under asymmetric stress control,the ratcheting strain increases rapidly with mean stress and stress amplitude increasing.Under high stress amplitude,the influence of mean stress is more significant.In addition,by studying the variation of strain energy density,it is found that the stress amplitude mainly promotes the fatigue damage,while the mean stress leads to the ratcheting damage.In addition,fractographic observation shows that the crack initiates in the brittle metal compound at the interface,and the steel has higher resistance to crack propagation.Finally,the accuracy of life prediction model considering ratcheting effect is discussed in detail,and a high-precision life prediction model directly based on mean stress and stress amplitude is proposed. 展开更多
关键词 zirconium−titanium−steel composite plate low cycle fatigue behavior fatigue damage mean stress ratcheting effect life prediction model
在线阅读 下载PDF
Application of anterior decompression and reconstruction using titanium mesh with locking plates in the management of cervical spondylotic myelopathy 被引量:3
8
作者 Maolin He Zengming Xiao Shide Li Qianfen Chen 《Journal of Nanjing Medical University》 2008年第4期260-264,共5页
Objective:To observe the clinical effect of anterior decompression and reconstruction using titanium mesh with locking plates in the treatment of cervical spondylotic myelopathy. Methods:One hundred and twenty patie... Objective:To observe the clinical effect of anterior decompression and reconstruction using titanium mesh with locking plates in the treatment of cervical spondylotic myelopathy. Methods:One hundred and twenty patients with cervical spondylotic myelopathy were treated by anterior decompression and reconstruction using titanium mesh with locking plates. There were 66 men and 54 women ranges in age from 37 to 72 Years(mean age, 58.3 years). The mean Japanese orthopedic surgery association(JOA) scale was 9.6 points before operation. Patients were followed up clinically and radiographically. Results:Having stood surgery well, the operation time ranged between 60-100 min and bleeding during operation ranged between 20-200 ml. There were no case of postoperative infection, recurrent laryngeal nerve palsy, or esophageal or tracheal laceration or rupture. The average follow-up period was 14.3 months(range, 12 to 24 months) in 96 who were followed up. At the last follow-up visit the mean JOA scale had improved to 14.4 points, reflecting an improvement of 4.8 points. The results were considered to be excellent in 87 patients, good in 25, fair in 6, and poor in 2. No hardware-related complications or adjacent segment degenerative changes were encountered during the follow-up periods. Stable bone union was observed in all cases and the average time required for fusion was 5.7 months. Conclusion:Titanium mesh filled with autologous bone graft can avoid the complications associated with harvesting bone from the iliac crest donor site. When combined with cervical anterior locking plate, it can obtain satisfatory clinical results for the treatment of cervical spondylotic myelopathy. 展开更多
关键词 cervical spondylotic myelopathy titanium mesli cervical vertebrae anterior cervical plate
暂未订购
Titanium Rib Plate Technique for Huge Chest Wall Reconstruction
9
作者 Yong Han Yoon 《Surgical Science》 2011年第6期331-334,共4页
Chest wall reconstruction after en-bloc tumor resection is very important to preserve functional mobility and to enhance the cosmetic effect. Because they are flexible and pliable, titanium plates are proposed to reco... Chest wall reconstruction after en-bloc tumor resection is very important to preserve functional mobility and to enhance the cosmetic effect. Because they are flexible and pliable, titanium plates are proposed to reconstruct the chest wall, even though such chest wall reconstruction has been performed in only a few cases worldwide. We present a case of a 49-year-old man with a chondrosarcoma arising from the left 1st rib, invading the manubrium, clavicle, 2nd and 3rd ribs, and the anterior segment of the left upper lobe. After wide resection, the chest wall was reconstructed using titanium rib plates and Marlex mesh- the Bovine pericardium sandwich type. The patient tolerated the pain well, and fourteen months after surgery, the chest wall was well preserved function mobility and improved pulmonary function test. 展开更多
关键词 CHEST WALL RECONSTRUCTION titanium plate CHONDROSARCOMA
暂未订购
SEM observation of bone interface of titanium-coated 317L plate screw
10
作者 姚小武 殷学民 朱明仁 《Journal of Medical Colleges of PLA(China)》 CAS 1997年第1期25-28,共4页
The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a ... The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a bone/metal interface in biointegration after implanted into the mandible of dog. Though a bone/metal interface in osseointegration was also formed on the surface of uncoated 317L plate screw after implantation, a smal1 space was seen between the bone and surface of the screw, indicating that the tissue compatibility of titanium-coated 317L plate screw may be better than that of the non-coated screw. 展开更多
关键词 titanium-coated 317L plate SCREW BONE INTERFACE
暂未订购
钛网植骨与Z-plate内固定在胸腰椎结核治疗中的应用 被引量:9
11
作者 曾荣 金勋杰 +2 位作者 李建宁 康毅 孙欣 《中国矫形外科杂志》 CAS CSCD 2004年第15期1140-1142,共3页
目的 :探讨胸腰椎结核一期完成前路病灶清除、钛网植骨和Z plate钢板内固定的可行性和优越性。方法 :2 0 0 0年 8月~ 2 0 0 3年 12月采用该手术方法治疗胸腰椎结核共 2 6例 ,其中胸椎 (T3~ 10 ) 9例 ,胸腰椎 (T11~L2 ) 13例 ,腰椎 (L... 目的 :探讨胸腰椎结核一期完成前路病灶清除、钛网植骨和Z plate钢板内固定的可行性和优越性。方法 :2 0 0 0年 8月~ 2 0 0 3年 12月采用该手术方法治疗胸腰椎结核共 2 6例 ,其中胸椎 (T3~ 10 ) 9例 ,胸腰椎 (T11~L2 ) 13例 ,腰椎 (L3~ 5) 4例。结果 :术后平均随访 13个月 ,植骨融合率 10 0 % ,后凸矫正角度平均 17°。 2 6例全部治愈 ,无 1例复发。结论 :本方法入路简单 ,所有操作在同一切口内完成 ;创伤小、出血少 ,不易损伤椎旁脏器及血管 ,安全性高 ;钛网配合Z plate使用 ,更有利子脊柱稳定性重建 。 展开更多
关键词 钛网融合器 Z-plate系统 结核 胸腰椎 内固定
暂未订购
有限元模拟下颌骨正中骨折的个性化钛板设计分析
12
作者 刘璐 王琦 +4 位作者 王怀升 程亚男 庄妍 陈贺 王心彧 《中国组织工程研究》 北大核心 2026年第14期3568-3575,共8页
背景:个性化钛板治疗颌面部骨折不仅可以缩短手术时间,还能提高患者满意度。然而,关于个性化钛板最优形状设计及其对骨折愈合的影响目前仍缺乏系统研究。目的:利用有限元对下颌骨正中骨折的个性化钛板进行优化设计。方法:将初始钛板及... 背景:个性化钛板治疗颌面部骨折不仅可以缩短手术时间,还能提高患者满意度。然而,关于个性化钛板最优形状设计及其对骨折愈合的影响目前仍缺乏系统研究。目的:利用有限元对下颌骨正中骨折的个性化钛板进行优化设计。方法:将初始钛板及颌骨模型导入软件中进行静力学分析,依据静力学分析结果进行拓扑优化。基于拓扑优化结果设计个性化钛板的基本形状。将个性化钛板、平行双板钛板、垂直双板钛板分别在双侧切牙咬合(工况1)、右侧磨牙咬合(工况2)、右侧切牙咬合(工况3)3种工况下进行有限元分析,筛选出在下颌骨正中骨折固定中力学性能最优的钛板。根据分析结果对个性化钛板进一步优化设计,设计直线型、上弯型、下弯型3种形态,通过有限元分析择出最优形态。以1 mm厚的上弯型个性化钛板为基础,设计梁(横梁和斜梁)分别为0.6,0.8,1.0,1.2,1.4,1.6,1.8,2.0 mm宽度的钛板,通过有限元分析确定合适的梁宽度,完成个性化钛板的优化设计。结果与结论:①依据拓扑优化结果设计了一款“8”字型个性化钛板。有限元分析结果显示,在工况1中,平行双板钛板组钛板最大等效应力值最小,垂直双板钛板组骨断端最大位移值最小;在工况2和工况3中,个性化钛板组钛板最大等效应力值和骨断端最大位移值均最小,力学性能更优。②在3种工况下,直线型个性化钛板组、上弯型个性化钛板组与下弯型个性化钛板组的钛板最大等效应力值和骨断端最大位移值差异较小,但上弯型个性化钛板组钛板应力分布更均匀。③对于1 mm厚的上弯型个性化钛板,当梁宽度≥1.6 mm时,钛板最大等效应力和骨断端最大位移值较为稳定;当梁宽度<1 mm时,骨断端最大位移值超出骨折初期愈合的范围,不利于愈合。④在下颌骨正中骨折有限元分析中,“8”字型结构个性化钛板较“一”字型具有应力分布更均匀、固定更稳固的优势,最终确定1 mm梁宽、1 mm厚的上弯型个性化钛板为下颌骨正中骨折的个性化钛板最优设计方案。 展开更多
关键词 个性化 钛板 优化 颏部 下颌骨 骨折 固定 有限元分析
暂未订购
前路减压、钛网支撑植骨、Z-Plate钢板内固定治疗陈旧性胸腰段脊柱骨折 被引量:13
13
作者 陈梓锋 郭延杰 +2 位作者 林斌 练克俭 郭志民 《临床骨科杂志》 2005年第4期304-306,共3页
目的探讨陈旧性胸腰段脊柱骨折伴脊髓损伤的前路减压和应用Z-Plate钢板内固定及钛网支撑植骨的优点。方法对48例陈旧性胸腰段脊柱骨折伴脊髓损伤的病例进行回顾性分析。结果48例均行前路椎管减压、钛网支撑植骨及Z-Plate钢板内固定。平... 目的探讨陈旧性胸腰段脊柱骨折伴脊髓损伤的前路减压和应用Z-Plate钢板内固定及钛网支撑植骨的优点。方法对48例陈旧性胸腰段脊柱骨折伴脊髓损伤的病例进行回顾性分析。结果48例均行前路椎管减压、钛网支撑植骨及Z-Plate钢板内固定。平均随访时间16.5个月,术后椎体间均获骨性融合,95.8%患者神经功能有不同程度恢复,平均改善1.1级,无并发症发生。结论该方法可充分利用切除的肋骨和减压碎骨块进行植骨,避免取自体髂骨,纠正脊柱后凸,提高椎体间融合率,以重新获得脊柱的稳定性。 展开更多
关键词 胸腰椎 脊柱骨折 陈旧性骨折 前路减压 Z-plate钢板 钛网
暂未订购
数字化导板下种植修复对牙列缺损患者美学效果及咀嚼功能的影响
14
作者 全旎 钱玲 +1 位作者 余明珠 姚倩倩 《中国美容医学》 2026年第1期121-124,共4页
目的:研究牙列缺损患者在使用数字化导板下钛合金种植体修复对其美学效果及咀嚼功能的影响。方法:选择2020年4月-2023年4月笔者医院收治的84例牙列缺损患者为研究对象,随机将其分成两组,每组42例。对照组采用常规种植修复方式治疗,观察... 目的:研究牙列缺损患者在使用数字化导板下钛合金种植体修复对其美学效果及咀嚼功能的影响。方法:选择2020年4月-2023年4月笔者医院收治的84例牙列缺损患者为研究对象,随机将其分成两组,每组42例。对照组采用常规种植修复方式治疗,观察组采用数字化导板下钛合金种植体修复。比较两组的临床疗效、种植精确度、美学效果及咀嚼功能。结果:修复后,观察组临床疗效优良率90.48%,高于对照组的71.43%(P<0.05);观察组患者的颈部距离偏差、根尖部距离偏差、深度偏差、角度偏差均小于对照组(P<0.05);修复后,两组PES评分、WES评分及美观度评分均提高,且观察组明显优于对照组(P<0.05);咬合力和咀嚼效率方面,两组患者均较修复前改善,且观察组高于对照组(P<0.05)。结论:数字化导板下钛合金种植体修复能更好地改善牙列缺损患者的修复疗效及咀嚼功能,提高种植修复的精确度和美学效果。 展开更多
关键词 数字化导板 钛合金种植体 牙列缺损 美学效果 修复 精确度
暂未订购
QUANTITATIVE RELATION BETWEEN YIELD STRESS AND R-VALUE OF Ti PLATE ALONG PARALLEL AND PERPENDICULAR TO ROLLING DIRECTION
15
作者 ZHANG Derong Shenyang Institute of Aeronautical Engineering,Shenyang,China ZHANG Derong Associate Professor.Dept.of Aeronautics,Shenyang Institute of Aeronautical Engineering,Shenyang 110031,China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1990年第9期196-199,共4页
An attempt was made on the quantitative prediction of the relationship hetween the yield stress and R-value along the parallel and perpendicular to the rolling direction of Ti plate based on analysis of the previous e... An attempt was made on the quantitative prediction of the relationship hetween the yield stress and R-value along the parallel and perpendicular to the rolling direction of Ti plate based on analysis of the previous experimental data.It is shown that the yield stress along one direction and another is quite synchronized with the R—value.According to the plasticity theo- ry,an formular of σ_(1s)/σ_(2s)=[(1+1/R_2)/(1+1/R_1)/^(1 2) was proposed,In statistic estima- tion.the calculated results are in good agreement with the experimental data.The availability of this formula was briefly discussed also. 展开更多
关键词 titanium plate yield stress R-VALUE
在线阅读 下载PDF
新型颈椎前路Uniplate钛板系统的初步临床应用
16
作者 刘建文 刘刚 +1 位作者 李仁杰 范勇 《医学信息(中旬刊)》 2011年第9期4646-4648,共3页
目的:探讨一种新型颈前路Uniplate钛板系统的初步临床应用效果及其设计特点和临床优势。方法:2008年8月-2009年3月,采用Uniplate钛板及碳纤维cage对11例患者进行颈前路单节段椎间盘切除、植骨融合术。其中Hangman骨折伴C2-3椎间盘损伤6... 目的:探讨一种新型颈前路Uniplate钛板系统的初步临床应用效果及其设计特点和临床优势。方法:2008年8月-2009年3月,采用Uniplate钛板及碳纤维cage对11例患者进行颈前路单节段椎间盘切除、植骨融合术。其中Hangman骨折伴C2-3椎间盘损伤6例;颈椎间盘突出并颈椎不稳3例;急性颈椎间盘突出2例。评价及分析Uniplate钛板的新型设计、术中操作特点及患者术后恢复情况。结果:所有患者内固定安放顺利,手术时间平均90min,出血平均85ml。无喉返神经及食管牵拉损伤等相关并发症发生。术后X线片示内固定位置良好,颈椎生理曲度恢复。结论:Uniplate颈前路钛板系统的独特设计,使其术中操作更加便捷,显著降低手术难度,而且有效减轻软组织牵拉。其初步临床应用效果较好,但远期效果还需大宗病例长期随访观察。 展开更多
关键词 颈椎 前路 Uniplate钛板 临床效果
暂未订购
TC18钛合金表面沉积CrAlSiN涂层的耐磨耐蚀性能研究
17
作者 陶伟琪 李睿 +7 位作者 鲁路 翟力 周志明 汪学静 张月霞 谢峰 吴亚渝 韩世伟 《广州化工》 2026年第1期87-90,共4页
通过对TC18钛合金进行等离子渗氮和物理气相沉积CrAlSiN涂层,对比研究了TC18钛合金基体、渗氮层和涂层表面的耐磨耐蚀性能。经等离子氮化处理后,TC18合金表面的显微硬度提高了1倍,CrAlSiN涂层的显微硬度提高了7.7倍,达到2818 HV_(0.05);... 通过对TC18钛合金进行等离子渗氮和物理气相沉积CrAlSiN涂层,对比研究了TC18钛合金基体、渗氮层和涂层表面的耐磨耐蚀性能。经等离子氮化处理后,TC18合金表面的显微硬度提高了1倍,CrAlSiN涂层的显微硬度提高了7.7倍,达到2818 HV_(0.05);CrAlSiN涂层的磨损机理主要为粘着磨损,涂层的磨损率为5.42×10^(-7)m^(3)/(N·m),比基体的磨损率降低了2个数量级,耐磨性能大幅提高。等离子氮化和沉积CrAlSiN涂层复合处理的自腐蚀电位比TC18基体明显正移,表面无明显腐蚀坑。表面多弧离子镀沉积CrAlSiN涂层有效提高了TC18钛合金的耐磨性和耐蚀性。 展开更多
关键词 TC18钛合金 多弧离子镀 等离子氮化 CrAlSiN涂层 耐磨性 耐蚀性
在线阅读 下载PDF
Effects of Ti_(0.5)Al_(0.5)N coatings on the protecting against oxidation for titanium alloys 被引量:7
18
作者 RU Qiang HU Shejun 《Rare Metals》 SCIE EI CAS CSCD 2010年第2期154-161,共8页
Ti0.5Al0.5N coatings were deposited on TC11(Ti-6.5Al-3.5Mo-1.5Zr-0.3Si) and silicon substrates using a cathode arc ion-plating system.The microstructure, composition, phase structure, and oxidation-resistance of the... Ti0.5Al0.5N coatings were deposited on TC11(Ti-6.5Al-3.5Mo-1.5Zr-0.3Si) and silicon substrates using a cathode arc ion-plating system.The microstructure, composition, phase structure, and oxidation-resistance of the alloys and nitride coatings were investigated by scanning electron microscopy, X-ray diffraction, transmission electron microscopy, Auger electron spectroscopy, and thermal analyzer.The results show that the oxidation resistance of the titanium alloy is relatively limited;the compound structures of Ti mixed with Al oxides are formed during the heating process.The phases of the Ti0.5Al0.5N coatings are composed of a TiN solid solution phase.The oxidation kinetics obeys the parabolic law.During the oxidation process, the selective oxidation of Al occurs, thus protecting the underlying coating and substrate. 展开更多
关键词 titanium alloy TiAlN oxidation resistance ion plating
在线阅读 下载PDF
Materials evolution of bone plates for internal fixation of bone fractures:A review 被引量:13
19
作者 Junlei Li Ling Qin +4 位作者 Ke Yang Zhijie Ma Yongxuan Wang Liangliang Cheng Dewei Zhao 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2020年第1期190-208,共19页
Bone plates play a vital role in bone fracture healing by providing the necessary mechanical fixation for fracture fragments through modulating biomechanical microenvironment adjacent to the fracture site.Good treatme... Bone plates play a vital role in bone fracture healing by providing the necessary mechanical fixation for fracture fragments through modulating biomechanical microenvironment adjacent to the fracture site.Good treatment effect has been achieved for fixation of bone fracture with conventional bone plates,which are made of stainless steel or titanium alloy.However,several limitations still exist with traditional bone plates including loosening and stress shielding due to significant difference in modulus between metal material and bone tissue that impairs optimal fracture healing.Additionally,due to demographic changes and non-physiological loading,the population suffering from refractory fractures,such as osteoporosis fractures and comminuted fractures,is increasing,which imposes a big challenge to traditional bone plates developed for normal bone fracture repair.Therefore,optimal fracture treatment with adequate fixation implants in terms of materials and design relevant to special conditions is desirable.In this review,the complex physiological process of bone healing is introduced,followed by reviewing the development of implant design and biomaterials for bone plates.Finally,we discuss recent development of hybrid bone plates that contains bioactive elements or factors for fracture healing enhancement as a promising direction.This includes biodegradable Mg-based alloy used for designing bone screw-plates that has been proven to be beneficial for fracture healing,an innovative development that attracts more and more attention.This paper also indicates that the tantalum bone plates with porous structure are also emerging as a new fracture internal fixation implants.The reduction of the stress shielding is verified to be useful to accelerate bone fracture healing.Potential application of biodegradable metals may also avoid a second operation for implant removal.Further developments in biometals and their design for orthopedic bone plates are expected to improve the treatment of bone fracture,especially the refractory fractures. 展开更多
关键词 BONE plate BIOMATERIALS BIODEGRADABLE MATERIALS titanium MAGNESIUM Porous TANTALUM
原文传递
前路病灶清除加钛网植骨、Z-plate内固定治疗多节段腰椎结核临床观察 被引量:3
20
作者 石坚 郭礼跃 樊世峰 《深圳中西医结合杂志》 2008年第1期38-40,共3页
目的:探讨前路病灶清除加钛网植骨、Z形前路钢板内同定治疗多节段腰椎结核的意义及疗效。方法:总结2002—2006年期间收治的12例多节段腰椎结核患者,并采用前路病灶清除,椎体间钛网植骨、Z形前路钢板内固定进行治疗。结果:随访8-29... 目的:探讨前路病灶清除加钛网植骨、Z形前路钢板内同定治疗多节段腰椎结核的意义及疗效。方法:总结2002—2006年期间收治的12例多节段腰椎结核患者,并采用前路病灶清除,椎体间钛网植骨、Z形前路钢板内固定进行治疗。结果:随访8-29个月(平均17个月),脊髓神经功能得到不同程度的恢复,植骨融合满意,钛网无松动、移位和塌陷,无内固定失败和脊柱结核复发,后凸角度平均矫正16.5(°)。2年后随访患者临床症状好转,脊柱畸形矫正情况满意。结论:前路病灶清除加钛网植骨、Z—plate内固定治疗多节段腰椎结核的术式有术野显露清楚、病灶清除更彻底、脊柱稳定性重建可靠、植骨融合率和结核治愈率高等特点,是目前外科治疗多节段腰椎结核的可靠方法之一。 展开更多
关键词 脊柱结核 手术治疗 前路病灶清除 钛网植骨 Z形前路钢板内固定
暂未订购
上一页 1 2 80 下一页 到第
使用帮助 返回顶部