Research on the overload protection reliability of moulded case circuit-breakers and its test device 被引量:14
1
作者 LI Kui LU Jian-guo +2 位作者 WU Yi QIN Zhi-jun YAO Dong-mei 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期453-458,共6页
This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on... This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly. 展开更多
关键词 Moulded case circuit breakers Overload protection RELIABILITY Test device
在线阅读 下载PDF
Study on the instantaneous protection reliability of low voltage circuit breakers 被引量:8
2
作者 LU Jian-guo DU Tai-hang LUO Yan-yan 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期370-377,共8页
This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage cir... This paper outlines the significance of enhancing the instantaneous protection reliability of low voltage circuit breakers and describes their main failure modes. The instantaneous failure mechanism of low voltage circuit breakers was analyzed so that measures to improve instantaneous protection reliability can be determined. Furthermore, the theory of the instantaneous characteristics calibration device for low voltage circuit breakers and the method of eliminating the non-periodic component of test current are given in detail. Finally, the test results are presented. 展开更多
关键词 Low voltage circuit breakers Instantaneous protection reliability Non-periodic component of current Phase selective closing
在线阅读 下载PDF
A New Analyzing Method of Single Event Latch-Up Protection Circuit Based on Current Comparing and Its Performance Verification 被引量:1
3
作者 Pengwei Li Xiaoyun Fu +1 位作者 Lei Luo Qingkui Yu 《Journal of Modern Physics》 2014年第6期387-393,共7页
Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit ... Single event latch-up (SEL) is a significant issue for electronics design in space application, which would cause large currents in electronic devices, and may lead to burning out of devices. A new monitoring circuit based on current-comparing method is designed to protect the electronics away from SEL’s damage in radiation environment. The response time of protection circuit has been analyzed. The signal simulation results indicated that the operating time of the SEL protection circuit is dependent on the action time of current comparator and system application recovery time. The function of the monitoring circuit protection device away from SEL’s damage has validated through experiment at last. 展开更多
关键词 SEL protection circuit Power-On TIME CUT-OFF TIME ADJUSTABLE RECOVERY TIME COTS
暂未订购
Effect and mechanism of on-chip electrostatic discharge protection circuit under fast rising time electromagnetic pulse
4
作者 Mao Xinyi Chai Changchun +3 位作者 Li Fuxing Lin Haodong Zhao Tianlong Yang Yintang 《强激光与粒子束》 CAS CSCD 北大核心 2024年第10期44-52,共9页
The electrostatic discharge(ESD)protection circuit widely exists in the input and output ports of CMOS digital circuits,and fast rising time electromagnetic pulse(FREMP)coupled into the device not only interacts with ... The electrostatic discharge(ESD)protection circuit widely exists in the input and output ports of CMOS digital circuits,and fast rising time electromagnetic pulse(FREMP)coupled into the device not only interacts with the CMOS circuit,but also acts on the protection circuit.This paper establishes a model of on-chip CMOS electrostatic discharge protection circuit and selects square pulse as the FREMP signals.Based on multiple physical parameter models,it depicts the distribution of the lattice temperature,current density,and electric field intensity inside the device.At the same time,this paper explores the changes of the internal devices in the circuit under the injection of fast rising time electromagnetic pulse and describes the relationship between the damage amplitude threshold and the pulse width.The results show that the ESD protection circuit has potential damage risk,and the injection of FREMP leads to irreversible heat loss inside the circuit.In addition,pulse signals with different attributes will change the damage threshold of the circuit.These results provide an important reference for further evaluation of the influence of electromagnetic environment on the chip,which is helpful to carry out the reliability enhancement research of ESD protection circuit. 展开更多
关键词 fast rising time electromagnetic pulse damage effect electrostatic discharge protection circuit damage location prediction
在线阅读 下载PDF
Protection of ±500 kV HVDC Double-circuit Converter Station from Lightning Induced Overvoltage 被引量:1
5
作者 DONG Manling YUAN Zhiyong +3 位作者 LI Tianwei ZHAO Xiangen ZHANG Jiaxin HE Junjia 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期2053-2060,共8页
In order to obtain reasonable schemes of arrester in converter stations, the arrester scheme of "Xiluodu-Guangdong HVDC ± 500 kV double circuit transmission" project against lighting induced overvoltage... In order to obtain reasonable schemes of arrester in converter stations, the arrester scheme of "Xiluodu-Guangdong HVDC ± 500 kV double circuit transmission" project against lighting induced overvoltage, which was designed according to the main principle of lightning protection in converter station, is discussed. A calculation of the lighting induced overvoltage in Zhaotong converter station un- der various operation modes is performed with ATP-EMTP software, then the surge arrester configuration of the converter station is decided, and the arrester protection schemes of smoothing reactor and neutral line are studied. It is concluded that additional protection is necessary because of the relatively large gap between protected disconnecting switch and arrester of metallic return transfer bus. Plus, the smoothing reactor (SR) arrester near the valve hall could be removed to improve the scheme’s economic performance. 展开更多
关键词 高压直流输电 过电压保护 换流站 双回路 雷电感应 ATP-EMTP 平波电抗器 避雷器
原文传递
Research of Pure Electric Ferry System and Its Short-Circuit Protection and Calculation
6
作者 Xiusong Yan Zechao Xu +1 位作者 Xingyu Yao Ning Wang 《Journal of Energy and Power Engineering》 2021年第1期8-15,共8页
System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system thr... System control and safety reliability are important links of the marine DC (Direct Current) power system. The simulationmodel is built by Matlab/Simulink, the battery and super-capacitor are supplied to the system through a three-phase interleaved DC/DCconverter, the fuse and disconnector switch combination are used as the protection device, and the short-circuit point is set betweeneach branch and the DC distribution board, performing short-circuit simulation. This paper also proposes a short-circuit calculationmethod for super-capacitors based on the simplified model of series RC (Resistors & Capacitors), and verifies its correctness throughsimulation data. The results show that the introduction of a three-phase interleaved DC/DC converter reduces the current ripple andmakes the system control more convenient;short-circuit calculation and simulation have determined the short-circuit withstandcapability of the DC distribution board, and verified the feasibility of the fuse selection method and the short-circuit calculation methodof the super-capacitor. This provides reliable verification for the application and calculation of the actual project. 展开更多
关键词 Matlab/simulink simulation three-phase interleaved DC/DC battery and super-capacitor short-circuit protection and calculation
在线阅读 下载PDF
Influence of DFIG Wind Turbine Protection and Control during Voltage Dip on Circuit Breaker Operation
7
作者 Anssi Salomo Makinen Ontrei Raipala Sami Repo Heikki Tuusa 《Journal of Energy and Power Engineering》 2013年第1期126-138,共13页
This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossing... This paper analyzes a DFIG (doubly fed induction generator) WT (wind turbine) fault current after a symmetrical network voltage dip. The goal is to identify the factors determining how fast the first zero crossings of the fault current occur. This is an important subject because the ftmdamental property of the CB (circuit breaker) is that it breaks the current when the current is very near zero. The study was conducted using a hardware-in-the-loop test environment constructed using two real time simulators (dSPACE and RTDS) and a commercial protection relay. It is found that the reactive current injection during a voltage dip demanded by the grid codes enhances the operation of the WT protection because the zero crossings of the currents through CB are attained earlier. In addition, the size of the crowbar resistance has a significant influence on the zero crossings. 展开更多
关键词 DFIG reactive current circuit breaker loss of mains relay protection.
在线阅读 下载PDF
Practical Drive and Protection Circuits for the IGBT
8
作者 ① GU Herong,ZHANG Chunjiang,LIU Yanmin (Yanshan University,Qinhuangdao 066004,CHN) 《Semiconductor Photonics and Technology》 CAS 1996年第4期39-42,共4页
The essential requirements of IGBT drive circuit is expounded.The short-circuit characteristic and over-current protection of the IGBT are described in detail.Finally,the practical drive and protection circuits are de... The essential requirements of IGBT drive circuit is expounded.The short-circuit characteristic and over-current protection of the IGBT are described in detail.Finally,the practical drive and protection circuits are designed.The practical results show that the circuit is good in performance. 展开更多
关键词 DRIVES IGBT protection circuit
全文增补中
Designing a spatial pattern to rebalance the orientation of development and protection in Wuhan 被引量:14
9
作者 JIN Gui SHI Xin +3 位作者 HE Dawei GUO Baishu LI Zhaohua SHI Xianbin 《Journal of Geographical Sciences》 SCIE CSCD 2020年第4期569-582,共14页
Patterns of spatial development and protection form a basic category of geoscience,and redesigning them is a popular subject of research in regional sustainable development that is important for ecological civilizatio... Patterns of spatial development and protection form a basic category of geoscience,and redesigning them is a popular subject of research in regional sustainable development that is important for ecological civilization construction.The authors here report a case study of Wuhan city using the circuit theory model and minimum cumulative resistance(MCR)model to rebalance its spatial protection and development.The results show the following:(1)Using the density of the gross domestic product(GDP),density of population,rate of urbanization,and access to transportation as evaluation indicators,seven core areas of development in Wuhan were identified,accounting for 59%of the total number of streets,that exhibited a “circular-satellite”spatial structure.(2)According to the importance of ecosystem services,ecological sensitivity,land use type,and slope of the terrain,the resistance surface of spatial development in Wuhan had a stereoscopic spatial form of an“inverted pyramid,”with high surroundings and a low center.The area of low resistance accounted for 6.64%of the total area of Wuhan.(3)Based on coupling analysis using the MCR and spatial morphological characteristics of current,nine axes of spatial development with a total area of 427.27 km2 and eight key strategic points with a total area of 40.02 km2 were identified.Streets that were prioritized for development accounted for 9.63%of Wuhan's total area.(4)By combining the characterization of the development axis with the structure of the three-level core area,we extracted the structure of spatial development of "one heart,two wings,and three belts" in Wuhan.The research framework and empirical results can provide scientific guidance for the urban spatial layout,the development of regional linkages,and ecological environmental protection in China. 展开更多
关键词 spatial DEVELOPMENT and protection circuit theory MODEL minimum CUMULATIVE resistance MODEL core area DEVELOPMENT axis WUHAN
原文传递
Protection Distance of Surge Protective Devices in Low Voltage Distribution Systems 被引量:1
10
作者 张栋 傅正财 +1 位作者 赵刚 孙伟 《Journal of Shanghai Jiaotong university(Science)》 EI 2008年第4期477-481,共5页
Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage... Protection distance of surge protective devices (SPDs) is an important problem in designing a good location scheme of SPDs in low voltage distribution systems for protecting electrical equipments against over- voltage caused by lightning stroke. The simplified lumped-parameter circuit model and the circuit method were used to study the protection distance problem of SPDs. The analytical solutions of the load voltage and general equations of the protection distance of SPDs under different load conditions were given. Simulation results of examples proved the validity of the proposed analytical method. 展开更多
关键词 over-voltage protection surge protective devices (SPDs) effective protection distance lumped-parameter circuit
原文传递
Multi-layer structures including zigzag sculptured thin films for corrosion protection of AISI 304 stainless steel 被引量:1
11
作者 Fateme Abdi 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期508-514,共7页
To increase corrosion resistance of the sample,its electrical impedance must be increased.Due to the fact that electrical impedance depends on elements such as electrical resistance,capacitance,and inductance,by incre... To increase corrosion resistance of the sample,its electrical impedance must be increased.Due to the fact that electrical impedance depends on elements such as electrical resistance,capacitance,and inductance,by increasing the electrical resistance,reducing the capacitance and inductance,electrical impedance and corrosion resistance can be increased.Based on the fact that these elements depend on the type of material and the geometry of the material,multilayer structures with different geometries are proposed.For this purpose,conventional multilayer thin films,multilayer thin film including zigzag structure(zigzag 1)and multilayer thin film including double zigzag structure(zigzag 2)of manganese nitride are considered to protect AISI 304 stainless steel against corrosion in salt solution.These multilayer coatings including zigzag structures are prepared by alternately using the conventional deposition of thin film and glancing angle deposition method.After deposition,the samples are placed in a furnace under nitrogen flux for nitriding.The cross sections of the structures are observed by field emission scanning electron microscopy(FESEM).Atomic force microscope(AFM)is used to make surface analyses of the samples.The results show that the multilayer thin films including zigzag structures have smaller grains than conventional multilayer thin films,and the zigzag 2 structure has the smaller grain than the other two samples,which is attributed to the effect of shadowing and porosity on the oblique angle deposition method.Crystallography structures of the samples are studied by using x-ray diffraction(XRD)pattern and the results show that nitride phase formation in zigzag 2 structure is better than that in zigzag 1 structure and conventional multilayer thin film.To investigate the corrosion resistances of the structures,electrochemical impedance spectroscopy(EIS)and potentiodynamic polarization tests are performed.The results reveal that the multilayer thin films with zigzag structures have better corrosion protection than the conventional multilayer thin films,and the zigzag structure 2 has the smallest corrosion current and the highest corrosion resistance.The electrical impedances of the samples are investigated by simulating equivalent circuits.The high corrosion resistance of zigzag 2 structure as compared with conventional multilayer structure and zigzag 1 structure,is attributed to the high electrical impedance of the structure due to its small capacitance and high electrical resistance.Finally,the surfaces of corroded samples are observed by scanning electron microscope(SEM). 展开更多
关键词 corrosion protection MULTILAYER zigzag thin film EIS equivalent circuit
原文传递
Protection of Low Voltage CIGRE Distribution Network 被引量:1
12
作者 Ghullam Mustafa Bhutto Birgitte Bak-Jensen +1 位作者 Claus Leth Bak Jayakrishnan R. Pillai 《Smart Grid and Renewable Energy》 2013年第9期489-500,共12页
High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is the protection of the system which needs to be fast, reliable and cos... High quality electricity services are the prime objectives in the modern power systems around the world. One of the main players to achieve this is the protection of the system which needs to be fast, reliable and cost effective. The study about the protection of the Low Voltage (LV) CIGRE distribution grid and networks like this has been proposed in this paper. The main objective of this paper is to develop protection against short circuit faults which might appear anywhere in the network. The protection of the power networks that comprises of renewable energy generation units is complicated because of the bidirectional flow of the current and is a challenge for the protection engineers. The selection of the protection devices in this paper is made to protect the network against faults in grid connected and island mode of operation. Ultra-fast fuses are proposed in order to protect the inverters used for Photovoltaic (PV) and battery applications. The disconnection of the PV solar panels when in island mode is made by proposing switch disconnecting devices. ABB is currently using these kinds of disconnection devices for the purpose of protecting solar panels against over voltages in the case of islanding. The over speed protection of the existing Wind Turbine Generator (WTG) in the CIGRE network in case of grid loss is also proposed in this paper. 展开更多
关键词 Current BASED protection VOLTAGE BASED protection Over Speed protection Fuse Under VOLTAGE Relay circuit BREAKER Switch DISCONNECTOR
暂未订购
Phenomena at three-phase electroslag remelting
13
作者 Zhong-li Liu Lev Medovar +3 位作者 Ganna Stovpchenko Volodymyr Petrenko Artem Sybir Yev.Volchenkov 《China Foundry》 SCIE CAS 2021年第6期557-564,共8页
The electroslag remelting(ESR)process is widely used to produce high-quality ingots and billets for high-alloyed steels and alloys.Both the single-phase and three-phase alternating current diagram with bifilar and mon... The electroslag remelting(ESR)process is widely used to produce high-quality ingots and billets for high-alloyed steels and alloys.Both the single-phase and three-phase alternating current diagram with bifilar and monofilar connection are in use for heavy ingot manufacturing.The numerical simulation of the three-phase bifilar circuit for the 120 t three-phase bifilar six-electrode ESR furnace at different variants of electric connection was presented and discussed.At the bifilar diagram of power supply,the geometrical location of electrodes in a mould holds critical importance for performances:the close location of bifilar pair electrodes provides the highest heat productivity,but the equidistant location of electrodes gives a much more uniform heat distribution.The monofilar mulit-electrode diagram of three-phase connection without phase shift shows the most uniform distribution of potential and heat generation as well as a favorable magnetic field that makes this kind the most promising for providing a high quality of heavy ingots. 展开更多
关键词 electroslag remelting three-phase circuit bifilar monofilar SIMULATION heavy ingot
在线阅读 下载PDF
Power supply arm protection scheme of high-speed railway based on wide-area current differential
14
作者 Guosong Lin Bin Hong +1 位作者 Zefang Wu Xuguo Fu 《Railway Engineering Science》 2023年第3期281-292,共12页
When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads t... When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved. 展开更多
关键词 Cross-coupling AT power supply Wide-area current differential Power supply arm protection Equivalent circuit High-Speed railway
在线阅读 下载PDF
Advancement in Wide Area Monitoring Protection and Control Using PMU’s Model in MATLAB/SIMULINK
15
作者 Waheed Ur Rahman Muhammad Ali +7 位作者 Amjad Ullah Hafeez Ur Rahman Majid Iqbal Haseeb Ahmad Adnan Zeb Zeeshan Ali M. Ahsan Shahzad Beenish Taj 《Smart Grid and Renewable Energy》 2012年第4期294-307,共14页
A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power system... A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station. 展开更多
关键词 WIDE Area MONITORING protection and CONTROL (WAMPAC) Phasor Measurement uNit (PMU) WIDE Area MONITORING (WAM) Global Positioning System (GPS) WIDE Area CONTROLLER (WAC) Local Area CONTROLLER (LAC) Phase Angle MONITORING (PAM) Automatic Generation CONTROL (AGC) circuit Breaker (CB) Current TRANSFORMERS (CTs) Potential TRANSFORMERS (PTs)
暂未订购
To Attack or Not: A Neural Circuit Coding Sexually Dimorphic Aggression
16
作者 Qiuhong Xin Hailan Hu 《Neuroscience Bulletin》 2025年第4期728-730,共3页
Aggression,an evolutionarily conserved social behavior,is essential for animals to compete for valuable resources like food,territory,and mates,and to protect kin.Although aggression is required for the survival of bo... Aggression,an evolutionarily conserved social behavior,is essential for animals to compete for valuable resources like food,territory,and mates,and to protect kin.Although aggression is required for the survival of both sexes,it is often displayed in a sexually dimorphic manner,with males typically exhibiting higher levels of aggression than females. 展开更多
关键词 resource competition kin protection MATES social behavior AGGRESSION sexually dimorphic aggression FOOD neural circuit
原文传递
KTX电源脉冲电容器熔断器保护设计
17
作者 冯虎林 王邓辉 +4 位作者 何宝灿 董玉琦 潘圣民 卢晶 吴亚楠 《核聚变与等离子体物理》 北大核心 2026年第1期57-62,共6页
反场箍缩磁约束聚变实验装置(KTX)的电源系统采用脉冲电容器组供电,提供的瞬间功率超过200 MW,因此脉冲电容器的短路保护至关重要,熔断器的设计和可靠性测试成为脉冲电容器保护的关键。KTX电源的高压高储能脉冲电容器保护设备造价高,采... 反场箍缩磁约束聚变实验装置(KTX)的电源系统采用脉冲电容器组供电,提供的瞬间功率超过200 MW,因此脉冲电容器的短路保护至关重要,熔断器的设计和可靠性测试成为脉冲电容器保护的关键。KTX电源的高压高储能脉冲电容器保护设备造价高,采用自主设计的低成本的熔断器保护电容器组的安全。根据温升要求,确定了熔断器的截面积。通过脉冲电容器最低压降要求及熔断器的最低熔断临界能量,确定了熔断器的长度,并且通过了仿真和实验验证。最终经过KTX电源长时间的运行验证了熔断器选择的安全和可靠性。 展开更多
关键词 KTX电源 脉冲电容器 短路保护 熔断器设计
在线阅读 下载PDF
质子交换膜电解槽内部短路故障特性分析及保护策略
18
作者 李斌 范辉 +3 位作者 何佳伟 李晔 吴张曦 王海洋 《电网技术》 北大核心 2026年第1期355-364,I0165,I0166,共12页
质子交换膜(proton exchange membrane,PEM)电解槽内部短路故障发展速度快且危害严重,快速可靠辨识故障对于提升制氢系统安全性具有重要意义。为此,该文开展了PEM电解槽内部短路故障特性与保护方法研究。首先,基于电解制氢的基本原理与... 质子交换膜(proton exchange membrane,PEM)电解槽内部短路故障发展速度快且危害严重,快速可靠辨识故障对于提升制氢系统安全性具有重要意义。为此,该文开展了PEM电解槽内部短路故障特性与保护方法研究。首先,基于电解制氢的基本原理与极化特性,构建了计及双电层电容效应的PEM电解槽等效电路模型。在此基础上,结合DC-DC变换器控制策略,提出了电解槽内部短路故障暂稳态特性精确计算方法。基于故障特性,提出了基于稳态电流变化量及功率变化量符号特征的保护判据,并分析了其动作边界。最后,大量仿真算例表明:该文所提故障特性分析方法计算的暂态电流平均相对误差小于5%,稳态电流相对误差小于1%,误差较小,所提保护策略能够正确辨识PEM电解槽的内部短路故障。 展开更多
关键词 可再生能源制氢 质子交换膜电解槽 短路特性 保护策略
原文传递
汽车电器系统线束故障检测与防护措施研究
19
作者 许丽 《汽车电器》 2026年第3期182-184,共3页
现代汽车工业正处在从机械驱动向软件定义汽车(SDV)转型的关键节点,车载电器设备的数量和种类呈指数级增长,使得汽车线束系统成为全车成本占比最高、质量最大、布线最复杂的零部件之一。作为整车电气系统的枢纽,线束担负着低压、高压电... 现代汽车工业正处在从机械驱动向软件定义汽车(SDV)转型的关键节点,车载电器设备的数量和种类呈指数级增长,使得汽车线束系统成为全车成本占比最高、质量最大、布线最复杂的零部件之一。作为整车电气系统的枢纽,线束担负着低压、高压电源的传输任务,还负责高速通信网络的数据流转。然而,线束一般敷设在车身钣金内部或者底盘下面,工作环境非常恶劣,长期受到机械磨损、化学腐蚀、热老化、电流过载的侵害。因此,本研究将深入探讨汽车电器系统线束故障检测与防护措施,探索适应智能网联汽车高可靠性需求的线束系统安全保障体系。 展开更多
关键词 汽车线束 故障检测 失效机理 电路保护
在线阅读 下载PDF
自给能中子探测器电荷累积效应研究及测量保护电路设计
20
作者 黄有骏 李昆 +4 位作者 刘耀隆 高志宇 罗庭芳 张芸 王立 《核动力工程》 北大核心 2026年第2期236-244,共9页
堆芯中子通量测量系统(CNFM)用于直接监测反应堆堆芯状态信息,其核心部件电流放大卡的可靠性和稳定性关系到整个系统的可用性。本文针对自给能中子探测器103Rh-SPND的电荷累积效应开展研究,完成了最严酷工况下微电流测量电路的电荷冲击... 堆芯中子通量测量系统(CNFM)用于直接监测反应堆堆芯状态信息,其核心部件电流放大卡的可靠性和稳定性关系到整个系统的可用性。本文针对自给能中子探测器103Rh-SPND的电荷累积效应开展研究,完成了最严酷工况下微电流测量电路的电荷冲击建模和计算,并依此开展了测量电路的保护方案设计和详细电路设计。通过实验室验证和堆上试验验证表明,未采取保护措施电流的放大卡测量电路出现了预期的损坏情况,采用本文防护方案的电流放大卡经受住了电荷冲击,同时保证了放大电路的精度、响应时间等特性。通过华龙一号2台机组的各类工况考验,证明该保护方案很好地提升了微电流测量电路的可用性。 展开更多
关键词 自给能中子探测器(SPND) 电荷累积 保护电路 瞬态电压抑制
原文传递