Simulated photo-degradation of fluorescent dissolved organic matter(FDOM) in Lake Baihua(BH) and Lake Hongfeng(HF) was investigated with three-dimensional excitationemission matrix(3 DEEM) fluorescence combined with t...Simulated photo-degradation of fluorescent dissolved organic matter(FDOM) in Lake Baihua(BH) and Lake Hongfeng(HF) was investigated with three-dimensional excitationemission matrix(3 DEEM) fluorescence combined with the fluorescence regional integration(FRI),parallel factor(PARAFAC) analysis,and multi-order kinetic models.In the FRI analysis,fulvic-like and humic-like materials were the main constituents for both BH-FDOM and HF-FDOM.Four individual components were identified by use of PARAFAC analysis as humic-like components(C1),fulvic-like components(C2),protein-like components(C3) and unidentified components(C4).The maximum 3 DEEM fluorescence intensity of PARAFAC components C1-C3 decreased by about 60%,70% and 90%,respectively after photo-degradation.The multi-order kinetic model was acceptable to represent the photo-degradation of FDOM with correlation coefficient(Radj2)(0.963-0.998).The photo-degradation rate constants(kn) showed differences of three orders of magnitude,from 1.09 × 10-6 to 4.02 × 10-4 min-1,and half-life of multi-order model(T1/2n)ranged from 5.26 to 64.01 min.The decreased values of fluorescence index(FI) and biogenic index(BI),the fact that of percent fluorescence response parameter of Region I(PⅠ,n) showed the greatest change ratio,followed by percent fluorescence response parameter of Region II(PⅡ,n,while the largest decrease ratio was found for C3 components,and the lowest T1/2n was observed for C3,indicated preferential degradation of protein-like materials/components derived from biological sources during photodegradation.This research on the degradation of FDOM by 3 DEEM/FRI-PARAFAC would be beneficial to understanding the photo-degradation of FD OM in natural environments and accurately predicting the environmental behaviors of contaminants in the presence of FDOM.展开更多
A new collapse model of the trapdoors,three-dimensional rectangular trapdoor(3DRT),is presented for ground surface collapse.Undrained stability of 3DRT is examined with the upper bound method of plasticity limit analy...A new collapse model of the trapdoors,three-dimensional rectangular trapdoor(3DRT),is presented for ground surface collapse.Undrained stability of 3DRT is examined with the upper bound method of plasticity limit analysis theory.The soil where the trapdoors are located is assumed to be a perfectly plastic model with a Tresca yield criterion.Block analysis technique is employed to investigate the collapse of 3DRT.The model is divided into five different block types and added up to ten rigid blocks.According to the law of conservation of energy,the critical stability ratios of 3DRT are obtained through a search proceeding.The results of upper bound solution for 3DRT are given,and three trapdoor models with depth various are discussed during the application in the stability analysis of square trapdoors.The critical stability ratios can be used in the design of underground excavation and support force.展开更多
The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical ...The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.展开更多
Antibody drugs,such as monoclonal antibodies and antibody-drug conjugates,have shown significant potential in treating diseases due to their high specificity and affinity.In vivo analysis of antibody drugs with non-in...Antibody drugs,such as monoclonal antibodies and antibody-drug conjugates,have shown significant potential in treating diseases due to their high specificity and affinity.In vivo analysis of antibody drugs with non-invasive and real-time techniques is of importance to understand dynamic behavior of drugs within living organisms,and help evaluate their pharmacokinetics and efficacies.This review summarizes the advances and in vivo analysis methods of antibody drugs,including the techniques of radiolabeled imaging,near-infrared fluorescence imaging and surface-enhanced Raman spectroscopy.The principles,applications,and challenges of each technique are discussed,which provides insights for the development of antibody drugs and in vivo analytical methods.展开更多
The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual worklo...The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual workload and poor image registration. Micro-magnetic resonance imaging(Micro-MRI), an emerging radiology technique, has been used to report results in the brain, liver and tumor tissues. However, micro-MRI usage for obtaining intraneural structures has not been reported. The aim of this study was to present a new imaging method for three-dimensional reconstruction of peripheral nerve fascicles by ~1T micro-MRI. Freshly harvested sciatic nerve samples from an amputated limb were divided into four groups. Two different scanning conditions(Mannerist Solution/GD-DTPA contrast agent, distilled water) were selected, and both T1 and T2 phases programmed for each scanning condition. Three clinical surgeons evaluated the quality of the images via a standardized scale. Moreover, to analyze deformation of the two-dimensional image, the nerve diameter and total area of the micro-MRI images were compared after hematoxylin-eosin staining. The results show that rapid micro-MRI imaging method can be used for three-dimensional reconstruction of the fascicle structure. Nerve sample immersed in contrast agent(Mannerist Solution/GD-DTPA) and scanned in the T1 phase was the best. Moreover, the nerve sample was scanned freshly and can be recycled for other procedures. MRI images show better stability and smaller deformation compared with histological images. In conclusion, micro-MRI provides a feasible and rapid method for three-dimensional reconstruction of peripheral nerve fascicles, which can clearly show the internal structure of the peripheral nerve.展开更多
Fluoro-ruby was injected into the posterior funiculus of the spinal cord in the cervical (C5-T2) and lumbar (L3-6) segments of adult guinea pigs. The spinal cord was cut into serial frozen sections. The Fluoro-rub...Fluoro-ruby was injected into the posterior funiculus of the spinal cord in the cervical (C5-T2) and lumbar (L3-6) segments of adult guinea pigs. The spinal cord was cut into serial frozen sections. The Fluoro-ruby labeling was clearly delineated from the surrounding structure. The labeling traversed the cervical, thoracic and lumbar segments, and was located on the ventral portion of the posterior funiculus on the injected side, proximal to the intermediate zone of the dorsal gray matter. The fluorescence area narrowed rostro-caudally. The spinal cord, spinal cord gray matter and corticospinal tract were reconstructed using 3D-DOCTOR 4.0 software, resulting in a robust three-dimensional profile. Using functionality provided by the reconstruction software, free multi-angle observation and sectioning could be conducted on the spinal cord and corticospinal tract. Our experimental findings indicate that the Fluoro-ruby retrograde fluorescent tracing technique can accurately display the anatomical location of corticospinal tract in the guinea pig and that three-dimensional reconstruction software can be used to provide a three-dimensional image of the corticospinal tract.展开更多
The present study aims to monitor and assess the water quality of the Bezerra River located in the Western Brazilian Parana state. For the monitoring of river waters, six samplings were established per month during on...The present study aims to monitor and assess the water quality of the Bezerra River located in the Western Brazilian Parana state. For the monitoring of river waters, six samplings were established per month during one year. As indicators of the water quality, physico-chemical parameters such as water temperature, pH, turbidity, dissolved oxygen and COD (chemical oxygen demand) were chosen, as well as trace and majority element concentrations. It is noteworthy that the mean annual values of conductivity, turbidity and COD have progressively increased along the river with maximum values after the Cascavel western sewage treatment plant. Only 13 elements were found in the six collection points, but the metallic elements Cr, Mn, Fe, Cu and Zn have shown concentrations above the maximum limits recommended by Brazilian environmental legislation, suggesting the presence of highly polluting anthropogenic sources. Correlation analyses were used to determine the spatio-variability of water quality variables. The six collection sites were grouped into two clusters, with the element composition in the first cluster (sites 1, 2 and 6) being due to strong anthropogenic activities. The study of the Bezerra River water quality could help to develop municipal environmental policies and help with the management of water conservation in the Bezerra River basin.展开更多
Three-dimensional fluorescence excitation–emission matrix(EEM) coupled with parallel factor analysis(PARAFAC) was performed for a total of 18 water samples taken from three water sources(two lakes and one wastew...Three-dimensional fluorescence excitation–emission matrix(EEM) coupled with parallel factor analysis(PARAFAC) was performed for a total of 18 water samples taken from three water sources(two lakes and one wastewater treatment plant(WWTP) secondary effluent),with the purpose of identifying the major ultrafiltration(UF) membrane foulants in different water sources. Three fluorescent components(C1, C2 and C3) were identified,which represented terrestrially derived humic-like substances(C1), microbially derived humic-like substances(C2), and protein-like substances(C3). The correlations between the different fluorescent components and UF membrane fouling were analyzed. It was shown that for the WWTP secondary effluent, all three components(C1, C2 and C3) made a considerable contribution to the irreversible and total fouling of the UF membrane.However, for the two lakes, only the C3 exhibited a strong correlation with membrane fouling, indicating that the protein-like substances were the major membrane foulants in the lake waters. Significant attachment of C1, C2 and C3 to the UF membrane was also confirmed by mass balance analyses for the WWTP secondary effluent; while the attachment of C1 and C2 was shown to be negligible for the two lakes. The results may provide basic formation for developing suitable fouling control strategies for sustainable UF processes.展开更多
Background:Radiological imaging plays a pivotal role in forensic anthropology.As have the imaging techniques advances,so have the digital skeletal measurements inched towards precision.Secular trends of the population...Background:Radiological imaging plays a pivotal role in forensic anthropology.As have the imaging techniques advances,so have the digital skeletal measurements inched towards precision.Secular trends of the population keep on changing in modem times.Hence,finding the precise technique of bone measurement,with greater reproducibility,in modem population is always needed in making population specific biological profile.Aim and Objective:The aim of this study was to estimate the accuracy of the foramen magnum measurement,obtained by three dimensional multi-detector computed tomography using volume rendering technique with the cut off value of each variable,in sex determination of an individual.Materials and Methods:Two metric traits,an antero-posterior diameter(APD)and transverse diameter(TD),were measured digitally in an analysis of 130 radiological images having equal proportion of male and female samples.Foramen magnum index and area of foramen magnum(Area by Radinsky's[AR],Area by Teixeira5s[AT])were derived from APD and TD.Results:Descriptive statistical analysis,using unpaired t-test,showed significant higher value in males in all the variables.Using Pearson correlation analysis,maximum correlation was observed between area(AT and AR r=0.999)and between area and TD(AR r=0.955 and AT r=0.945 respectively).When used individually,TD had the highest predictive value(67.7%)for sex detennination among all the parameters followed by AT(65.4%)and AR(64.6%).Cutoff value of variables TD,AR and AT were 29.9 mm,841.80 mm2 and 849.70 mm2 respectively.Receiver operating characteristic curve predicted male and female sex with 96.2%and 89.2%accuracy respectively.The overall accuracy of the model was 92.7%.Conclusion:Measurements from 3D CT using volume rendering technique were precise,and the application of logistic regression analysis predicted the sex with more accuracy.展开更多
Since the solvent evaporation of a droplet on a hydrophobically pretreated glass slide, femtomole amount of fluorescent materials is carried by the evaporation and results in outward capillary flow to the perimeter of...Since the solvent evaporation of a droplet on a hydrophobically pretreated glass slide, femtomole amount of fluorescent materials is carried by the evaporation and results in outward capillary flow to the perimeter of the droplet spot where the solute deposits, and forms a fluorescent ring like deposit (RLD) with submicrometer-scale structures.展开更多
基金financially supported by the National Natural Science Foundation of China(No.41573130)BNU Interdisciplinary Research Foundation for First-Year Doctoral Candidates(No.BNUXKJC1802)
文摘Simulated photo-degradation of fluorescent dissolved organic matter(FDOM) in Lake Baihua(BH) and Lake Hongfeng(HF) was investigated with three-dimensional excitationemission matrix(3 DEEM) fluorescence combined with the fluorescence regional integration(FRI),parallel factor(PARAFAC) analysis,and multi-order kinetic models.In the FRI analysis,fulvic-like and humic-like materials were the main constituents for both BH-FDOM and HF-FDOM.Four individual components were identified by use of PARAFAC analysis as humic-like components(C1),fulvic-like components(C2),protein-like components(C3) and unidentified components(C4).The maximum 3 DEEM fluorescence intensity of PARAFAC components C1-C3 decreased by about 60%,70% and 90%,respectively after photo-degradation.The multi-order kinetic model was acceptable to represent the photo-degradation of FDOM with correlation coefficient(Radj2)(0.963-0.998).The photo-degradation rate constants(kn) showed differences of three orders of magnitude,from 1.09 × 10-6 to 4.02 × 10-4 min-1,and half-life of multi-order model(T1/2n)ranged from 5.26 to 64.01 min.The decreased values of fluorescence index(FI) and biogenic index(BI),the fact that of percent fluorescence response parameter of Region I(PⅠ,n) showed the greatest change ratio,followed by percent fluorescence response parameter of Region II(PⅡ,n,while the largest decrease ratio was found for C3 components,and the lowest T1/2n was observed for C3,indicated preferential degradation of protein-like materials/components derived from biological sources during photodegradation.This research on the degradation of FDOM by 3 DEEM/FRI-PARAFAC would be beneficial to understanding the photo-degradation of FD OM in natural environments and accurately predicting the environmental behaviors of contaminants in the presence of FDOM.
基金the Fundamental Research Funds for the Provincial Universities,China(No.702/000007020303)。
文摘A new collapse model of the trapdoors,three-dimensional rectangular trapdoor(3DRT),is presented for ground surface collapse.Undrained stability of 3DRT is examined with the upper bound method of plasticity limit analysis theory.The soil where the trapdoors are located is assumed to be a perfectly plastic model with a Tresca yield criterion.Block analysis technique is employed to investigate the collapse of 3DRT.The model is divided into five different block types and added up to ten rigid blocks.According to the law of conservation of energy,the critical stability ratios of 3DRT are obtained through a search proceeding.The results of upper bound solution for 3DRT are given,and three trapdoor models with depth various are discussed during the application in the stability analysis of square trapdoors.The critical stability ratios can be used in the design of underground excavation and support force.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11675019 and 11875087).
文摘The measurement of the confocal volume of a confocal three-dimensional micro-x-ray fluorescence(3D-XRF)setup is a key step in the field of confocal 3D-XRF analysis.With the development of x-ray facilities and optical devices,3D-XRF analysis with a micro confocal volume will create a great potential for 2D and 3D microstructural analysis and accurate quantitative analysis.However,the classic measurement method of scanning metal foils of a certain thickness leads to inaccuracy.A method for calibrating the confocal volume is proposed in this paper.The new method is based on the basic content of the textbook,and the theoretical results and the feasibility are given in detail for the 3D-XRF mono-chromatic x-ray condition and the poly-chromatic x-ray condition.We obtain a set of experimental confirmation using the poly-chromatic x-ray tube in the laboratory.It is proved that the sensitivity factor of the 3D-XRF can be directly and accurately obtained in a real calibration process.
基金support from the National Natural Science Foundation of China(Grant Nos.:22322403 and 22074006)the Beijing Natural Science Foundation(Grant No.:2222029)the Beijing Institute of Technology Research Fund Program for Young Scholars.
文摘Antibody drugs,such as monoclonal antibodies and antibody-drug conjugates,have shown significant potential in treating diseases due to their high specificity and affinity.In vivo analysis of antibody drugs with non-invasive and real-time techniques is of importance to understand dynamic behavior of drugs within living organisms,and help evaluate their pharmacokinetics and efficacies.This review summarizes the advances and in vivo analysis methods of antibody drugs,including the techniques of radiolabeled imaging,near-infrared fluorescence imaging and surface-enhanced Raman spectroscopy.The principles,applications,and challenges of each technique are discussed,which provides insights for the development of antibody drugs and in vivo analytical methods.
基金supported by grants from the National Key Research and Development Plan of China,No.31670986(to QTZ)the Science and Technology Project of Guangdong Province of China,No.2014B020227001,2017A050501017(to QTZ)the Science and Technology Project of Guangzhou of China,No.201807010082(to QTZ),201704030041(to JQ)
文摘The most common methods for three-dimensional reconstruction of peripheral nerve fascicles include histological and radiology techniques. Histological techniques have many drawbacks including an enormous manual workload and poor image registration. Micro-magnetic resonance imaging(Micro-MRI), an emerging radiology technique, has been used to report results in the brain, liver and tumor tissues. However, micro-MRI usage for obtaining intraneural structures has not been reported. The aim of this study was to present a new imaging method for three-dimensional reconstruction of peripheral nerve fascicles by ~1T micro-MRI. Freshly harvested sciatic nerve samples from an amputated limb were divided into four groups. Two different scanning conditions(Mannerist Solution/GD-DTPA contrast agent, distilled water) were selected, and both T1 and T2 phases programmed for each scanning condition. Three clinical surgeons evaluated the quality of the images via a standardized scale. Moreover, to analyze deformation of the two-dimensional image, the nerve diameter and total area of the micro-MRI images were compared after hematoxylin-eosin staining. The results show that rapid micro-MRI imaging method can be used for three-dimensional reconstruction of the fascicle structure. Nerve sample immersed in contrast agent(Mannerist Solution/GD-DTPA) and scanned in the T1 phase was the best. Moreover, the nerve sample was scanned freshly and can be recycled for other procedures. MRI images show better stability and smaller deformation compared with histological images. In conclusion, micro-MRI provides a feasible and rapid method for three-dimensional reconstruction of peripheral nerve fascicles, which can clearly show the internal structure of the peripheral nerve.
基金supported by a grant from the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘Fluoro-ruby was injected into the posterior funiculus of the spinal cord in the cervical (C5-T2) and lumbar (L3-6) segments of adult guinea pigs. The spinal cord was cut into serial frozen sections. The Fluoro-ruby labeling was clearly delineated from the surrounding structure. The labeling traversed the cervical, thoracic and lumbar segments, and was located on the ventral portion of the posterior funiculus on the injected side, proximal to the intermediate zone of the dorsal gray matter. The fluorescence area narrowed rostro-caudally. The spinal cord, spinal cord gray matter and corticospinal tract were reconstructed using 3D-DOCTOR 4.0 software, resulting in a robust three-dimensional profile. Using functionality provided by the reconstruction software, free multi-angle observation and sectioning could be conducted on the spinal cord and corticospinal tract. Our experimental findings indicate that the Fluoro-ruby retrograde fluorescent tracing technique can accurately display the anatomical location of corticospinal tract in the guinea pig and that three-dimensional reconstruction software can be used to provide a three-dimensional image of the corticospinal tract.
文摘The present study aims to monitor and assess the water quality of the Bezerra River located in the Western Brazilian Parana state. For the monitoring of river waters, six samplings were established per month during one year. As indicators of the water quality, physico-chemical parameters such as water temperature, pH, turbidity, dissolved oxygen and COD (chemical oxygen demand) were chosen, as well as trace and majority element concentrations. It is noteworthy that the mean annual values of conductivity, turbidity and COD have progressively increased along the river with maximum values after the Cascavel western sewage treatment plant. Only 13 elements were found in the six collection points, but the metallic elements Cr, Mn, Fe, Cu and Zn have shown concentrations above the maximum limits recommended by Brazilian environmental legislation, suggesting the presence of highly polluting anthropogenic sources. Correlation analyses were used to determine the spatio-variability of water quality variables. The six collection sites were grouped into two clusters, with the element composition in the first cluster (sites 1, 2 and 6) being due to strong anthropogenic activities. The study of the Bezerra River water quality could help to develop municipal environmental policies and help with the management of water conservation in the Bezerra River basin.
基金supported by the National Natural Science Foundation of China(No.51208140)the National Water Pollution Control and Treatment Science and Technology Major Project of China(No.2012ZX07201002)
文摘Three-dimensional fluorescence excitation–emission matrix(EEM) coupled with parallel factor analysis(PARAFAC) was performed for a total of 18 water samples taken from three water sources(two lakes and one wastewater treatment plant(WWTP) secondary effluent),with the purpose of identifying the major ultrafiltration(UF) membrane foulants in different water sources. Three fluorescent components(C1, C2 and C3) were identified,which represented terrestrially derived humic-like substances(C1), microbially derived humic-like substances(C2), and protein-like substances(C3). The correlations between the different fluorescent components and UF membrane fouling were analyzed. It was shown that for the WWTP secondary effluent, all three components(C1, C2 and C3) made a considerable contribution to the irreversible and total fouling of the UF membrane.However, for the two lakes, only the C3 exhibited a strong correlation with membrane fouling, indicating that the protein-like substances were the major membrane foulants in the lake waters. Significant attachment of C1, C2 and C3 to the UF membrane was also confirmed by mass balance analyses for the WWTP secondary effluent; while the attachment of C1 and C2 was shown to be negligible for the two lakes. The results may provide basic formation for developing suitable fouling control strategies for sustainable UF processes.
文摘Background:Radiological imaging plays a pivotal role in forensic anthropology.As have the imaging techniques advances,so have the digital skeletal measurements inched towards precision.Secular trends of the population keep on changing in modem times.Hence,finding the precise technique of bone measurement,with greater reproducibility,in modem population is always needed in making population specific biological profile.Aim and Objective:The aim of this study was to estimate the accuracy of the foramen magnum measurement,obtained by three dimensional multi-detector computed tomography using volume rendering technique with the cut off value of each variable,in sex determination of an individual.Materials and Methods:Two metric traits,an antero-posterior diameter(APD)and transverse diameter(TD),were measured digitally in an analysis of 130 radiological images having equal proportion of male and female samples.Foramen magnum index and area of foramen magnum(Area by Radinsky's[AR],Area by Teixeira5s[AT])were derived from APD and TD.Results:Descriptive statistical analysis,using unpaired t-test,showed significant higher value in males in all the variables.Using Pearson correlation analysis,maximum correlation was observed between area(AT and AR r=0.999)and between area and TD(AR r=0.955 and AT r=0.945 respectively).When used individually,TD had the highest predictive value(67.7%)for sex detennination among all the parameters followed by AT(65.4%)and AR(64.6%).Cutoff value of variables TD,AR and AT were 29.9 mm,841.80 mm2 and 849.70 mm2 respectively.Receiver operating characteristic curve predicted male and female sex with 96.2%and 89.2%accuracy respectively.The overall accuracy of the model was 92.7%.Conclusion:Measurements from 3D CT using volume rendering technique were precise,and the application of logistic regression analysis predicted the sex with more accuracy.
文摘Since the solvent evaporation of a droplet on a hydrophobically pretreated glass slide, femtomole amount of fluorescent materials is carried by the evaporation and results in outward capillary flow to the perimeter of the droplet spot where the solute deposits, and forms a fluorescent ring like deposit (RLD) with submicrometer-scale structures.