期刊文献+
共找到71篇文章
< 1 2 4 >
每页显示 20 50 100
Synthesis and fluorescent properties of a one-dimensional Tb-calixarene complex as a luminescent thermometer material
1
作者 PENG Dan WANG Hao +2 位作者 WANG Yanyan YOU Hongpeng LIAO Wuping 《无机化学学报》 北大核心 2025年第9期1859-1866,共8页
Luminescence thermometry has attracted more and more attention due to its non-contact and noninvasive operation,fast response,high spatial resolution,and so on,for which the luminescent thermometers are the key.Here,a... Luminescence thermometry has attracted more and more attention due to its non-contact and noninvasive operation,fast response,high spatial resolution,and so on,for which the luminescent thermometers are the key.Here,a 1D complex[Tb_(4)(HTC4A)(TC4A)(OBBA)_(2)(CH_(3)OH)_(4)(μ4-OH)]n(1)was obtained by solvothermal synthesis,where H 4TC4A=p-tert-butylthiacalix[4]arene,and H_(2)OBBA=4,4'-oxybisbenzoic acid.This complex is featured with a chain-like polymer constructed by bridging some sandwich-like Tb_(4)-(TC4A)_(2)entities through OBBA2-ligands.It exhibited the characteristic emission of the Tb^(3+)ion.Both fluorescence intensity and lifetime decreased with increasing temperature.The relative sensitivity was up to 8.743%·K^(-1)at 473 K,indicating it is a good ratiometric luminescent thermometer.This complex had good stability under different pH values and in common solvents.CCDC:2392643. 展开更多
关键词 TERBIUM CALIXARENES complexes luminescent thermometer
在线阅读 下载PDF
Heteronuclear lanthanide titanium-oxygen cluster luminescence thermometer with adjustable operating range and sensitivity
2
作者 Ting-Ting Li Jin-Zhe Liu +8 位作者 Shao-Jiang Zheng Feng Jiang Jin-Yu Liu Wei-Nan Dong Yu Zhang Shao-Ping Zheng Ya-Nan Li Zhen-Nan Wu Xue Bai 《Rare Metals》 2025年第4期2438-2449,共12页
Given customizable crystal structure and intriguing optical properties,lanthanide titanium-oxygen clusters(LTOCs)with atomic-level accuracy have gained a lot of interest.In this study,we prepared[Ln_(9)Ti_(2)(μ4-O)(... Given customizable crystal structure and intriguing optical properties,lanthanide titanium-oxygen clusters(LTOCs)with atomic-level accuracy have gained a lot of interest.In this study,we prepared[Ln_(9)Ti_(2)(μ4-O)(μ3-OH)_(14)(acac)_(17)(CH_(3)O)_(2)(CH_(3)OH)_(3)](Ln=Tb_(x)Eu_(9−x)(x=0,4,6,7,8,9),Hacac=acetylacetone),Tb^(3+)and Eu^(3+)co-doped LTOCs,to modify the optical properties for the luminescence thermometer.In detail,the serial LTOCs display dual characteristic emission peaks of ^(5)D_(4)→^(7)F_(5) for Tb^(3+)and^(5)D_(0)→^(7)F_(2) for Eu^(3+)at 548 and 616 nm,respectively,under 330 nm excitation.Effective energy transfer(ET)between Tb^(3+)ions and Eu^(3+)ions was revealed in terms of both emission spectra and luminescence lifetime.The ^(5)D_(0)→^(7)F_(2) emission intensity of Eu^(3+)ions at 616 nm is maximally enhanced(by a factor of 11.2)with a change in the relative molar ratio of Tb^(3+)to Eu^(3+),along with a change in the ET efficiency of Tb^(3+)→Eu^(3+).In addition,the luminescent color changes from red,orange,yellow,to green.This precise control of the ET process between rare-earth ions allows{Tb_(6)Eu_(3)Ti_(2)}to reach a maximum relative sensitivity of 1.241 K^(−1) at 355 K,which is an enhancement of up to 4.6-fold with respect to the previously reported homonuclear emission,holding great potential in the optical thermometers. 展开更多
关键词 Lanthanide titanium-oxygen clusters Energy transfer Color-changing luminescence Optical thermometer
原文传递
A novel Tb^(3+) and Eu^(3+) co-doped dual-emitting phosphate K_(3)SrBi(P_(2)O_(7))_(2) phosphor for application in FIR thermometers 被引量:3
3
作者 Baochen Wang Shifeng Sun +5 位作者 Zeqi Li Zongwang Li Weiwei Lin Chao Zeng Yan-gai Liu Ruiyu Mi 《Journal of Rare Earths》 SCIE EI CAS CSCD 2024年第3期455-463,I0001,共10页
Rare earth co-doped phosphor for fluorescence intensity ratio(FIR) thermometer has gained increasing attention in recent years. Herein, the novel Tb^(3+)and Eu^(3+)co-doped K_(3)SrBi(P_(2)O_(7))_(2)(KSBP) phosphate ph... Rare earth co-doped phosphor for fluorescence intensity ratio(FIR) thermometer has gained increasing attention in recent years. Herein, the novel Tb^(3+)and Eu^(3+)co-doped K_(3)SrBi(P_(2)O_(7))_(2)(KSBP) phosphate phosphors were reported. The crystal structure of the title phosphor was determined using Rietveld refinement and proved to have a three-dimensional structure. The time-resolved spectroscopy reveals that there is almost no energy transfer between Tb^(3+)and Eu^(3+). More importantly, Tb^(3+)and Eu^(3+)emissions show different thermal quenching behaviors, which claims the potential of this material for application in optical thermometer. The FIR of the typical KSBP:0.02Tb^(3+),0.04Eu^(3+)sample demonstrates a polynomial relationship as a function of temperature and the absolute and relative sensitivity are0.025 K^(-1) and 0.59%/K, respectively. In general, our study reports a novel and potential KSBP:Tb^(3+),Eu^(3+)phosphate phosphor that is promising for use in high-sensitive FIR thermometers. 展开更多
关键词 PHOSPHOR thermometer Fluorescence intensity ratio Thermal stability Rare earths
原文传递
A dual-mode optical thermometer based on dual-excitation Bi^(3+),Sm^(3+)co-doped Y_(4)GeO_(8) phosphors 被引量:2
4
作者 Danyu Zhang Yuxuan Luo +2 位作者 Junyu Chen Lianjie Li Hai Guo 《Journal of Rare Earths》 SCIE EI CAS CSCD 2024年第8期1437-1446,I0002,共11页
Dual-excitation and dual-emission Y_(4)GeO_(8):Bi^(3+),Sm^(3+)phosphors were manufactured by traditional solidphase sintering technique.The X-ray diffraction,morphology,photoluminescence,energy transfer process and te... Dual-excitation and dual-emission Y_(4)GeO_(8):Bi^(3+),Sm^(3+)phosphors were manufactured by traditional solidphase sintering technique.The X-ray diffraction,morphology,photoluminescence,energy transfer process and temperature sensing properties of Y_(4)GeO_(8):Bi^(3+),Sm^(3+)samples were comprehensively evaluated.The Y4GeO_(8):Bi^(3+),Sm^(3+)phosphors exhibit characteristic emissions of Bi^(3+)(^(3)P_(1)→^(1)S_(0)) and Sm^(3+)(^(4)G_(5/2)→^(6)H)under both 290 and 347 nm excitations.In fluorescence intensity ratio and Commission International de L'Eclairage coordinates modes,Y_(4)GeO_(8):Bi^(3+),Sm^(3+)samples present excellent temperature measurement performance.The maximum relative sensitivity(S_(r-max)) values of the former are 1.55%/K(460 K,290 nm excitation) and 0.82%/K(506 K,347 nm excitation).The S_(r-max)(x) values of the latter are 0.21 %/K(437 K,290 nm excitation) and 0.15%/K(513 K,347 nm excitation).These results illustrate that Y_(4)GeO_(8):Bi^(3+),Sm^(3+)phospho rs can be used as a candidate material for a dual-mode optical thermometer under dual-excitation. 展开更多
关键词 Dual-mode optical thermometer Luminescent properties Y_(4)GeO_(8):Bi^(3+) Sm^(3+)phosphors Rare earths
原文传递
A ratiometric optical thermometer with dual-color emission based on Eu^(2+)-doped CsCu_(2)I_(3) microcrystals 被引量:1
5
作者 Xiaorong Li Ge Gao +5 位作者 Kaiyu Wang Zhaoqiong Chen Zejiang Gao Qingyong Qin Li Chen Bingsuo Zou 《Journal of Rare Earths》 SCIE EI CAS CSCD 2024年第8期1429-1436,I0001,共9页
With the increasing demand for non-co ntact fluorescence intensity ratio-based optical thermometry,novel phosphor materials with high-efficiency,dual-emitting centers,and differentiable temperature sensitivity are hig... With the increasing demand for non-co ntact fluorescence intensity ratio-based optical thermometry,novel phosphor materials with high-efficiency,dual-emitting centers,and differentiable temperature sensitivity are highly desired,In this wo rk,rare earth Eu^(2+) ions were incorporated Wnto CsCu_(2)I_(3) microcrystals by solidstate reaction,Under a single UV excitation,the as-synthesized samples exhibit two emissions:452 nm blue emission from the 5d→4f transition of Eu^(2+)and 582 nm yellow emission from self-trapped exciton e mission of CsCu_(2)I_(3).The photoluminescence quantum yield reaches to 50%,The dual-band emission of Eu^(2+)-doped CsCu_(2)I_(3) shows different temperature responses in the range of 260-360 K.Based on fluorescence intensity ratio technology,the maximum absolute sensitivity and re Iative sensitivity are 0.091 K^(-1)(at 360 K) and 2.60%/K(at 260 K),respectively.These results suggest that Eu^(2+)-doped GsCu_(2)I_(3) could be a good candidate for highly sensitive optical thermometer. 展开更多
关键词 CsCu_(2)I_(3) Eu^(2+)-doping Fluorescence intensity ratio Optical thermometer Rare earths
原文传递
Oil-surface Thermometers Recognition Method Using Multi-Task Cascade Neural Network
6
作者 Weisheng Lao Bin Sun +2 位作者 Yuxiao Zhao Chaoping Sun Xu Dai 《Instrumentation》 2024年第4期13-20,共8页
Currently,the oil-surface thermometer remains a crucial monitoring device in substations.However,challenges such as uneven scale distribution,inadequate model accuracy,and low reading precision persist in handling rea... Currently,the oil-surface thermometer remains a crucial monitoring device in substations.However,challenges such as uneven scale distribution,inadequate model accuracy,and low reading precision persist in handling readings from various types of oilsurface thermometers.This paper presents a high-precision recognition method based on neural networks for accurately reading various types of oil-surface thermometers.The proposed recognition method mainly comprises the YOLOv5 convolutional network,the attention U2-Net semantic segmentation network,and enhanced computational methods.This detection method demonstrates ultra-high precision and can be applied to different types of oilsurface thermometers.Compared to existing methods,the proposed detection method exhibits outstanding accuracy and effectiveness.A comprehensive set of tests was performed to assess the viability and reliability of the approach.Findings reveal that the maximum error margin in its measurements remains below 0.13%. 展开更多
关键词 oil-surface thermometer enhanced computational methods semantic segmentation object detection
原文传递
Trichromatic Optical Fiber Radiation Thermometer
7
作者 LIU Zhiyan,WANG Yutian(Yanshan University,Qinhuangdao 066004,CHN) 《Semiconductor Photonics and Technology》 CAS 1996年第2期155-158,141,共5页
The study on trichromatic optical fiber radiation thermometers is especially useful for the non-contact accurate temperature measurement of those materials with the emissivities changing dramatically with wavelength.O... The study on trichromatic optical fiber radiation thermometers is especially useful for the non-contact accurate temperature measurement of those materials with the emissivities changing dramatically with wavelength.On the basis of the trichromatic thermometry principle,the operation wavelengths of the thermometer are selected properly so as to compensate the emissivity influence on measurement result effectively. Using 1×3 branching fiber coupler and narrow band filter significantly improves the instrument reliability.The instrument is self-calibrated,multi -functional and easy touse due to the embodied microcontroller and some other techniques. 展开更多
关键词 Optical Fiber thermometer Trichromatic thermometer Fiber Coupler
在线阅读 下载PDF
Validation And Reliability of Distress Thermometer in Chinese Cancer Patients 被引量:60
8
作者 Li-li Tang Ye-ning Zhang Ying Pang Hai-wei Zhang Li-li Song 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2011年第1期54-58,共5页
Objective:To examine the validation and reliability of the distress thermometer(DT) recommended by National Comprehensive Cancer Network(NCCN) in Chinese cancer patients.Methods:A total of 574 Chinese cancer pat... Objective:To examine the validation and reliability of the distress thermometer(DT) recommended by National Comprehensive Cancer Network(NCCN) in Chinese cancer patients.Methods:A total of 574 Chinese cancer patients from Beijing Cancer Hospital completed the detection of DT,the Hospital Anxiety and Depression Scale(HADS) and Symptom Checklist 90(SCL-90),Receiver Operating Characteristic(ROC) curve and Area Under the Curve(AUC) were used to analyze the validation relative to HADS and SCL-90.The patients with DT≥4 and whose distress caused by emotional problems were interviewed with the MiNi International Neuro-psychiatric Interview(MINI)(Chinese Version 5.0).This version was used to analyze cancer patients' psychological and Psychiatric symptoms during the cancer process;3.Another 106 cancer patients in rehabilitation stage and stable condition were asked to fill in DT two times,at the base time and after 7-10 days.Results:Data of ROC indicates that a DT cutoff score of 4 yielded AUC of 0.80 with a optimal sensitivity(0.80) and specificity(0.70) relative to HADS,and AUC of 0.83 with the greatest sensitivity(0.87) and specificity(0.72) against SCL-90.The DT also has acceptable test-retest reliability(r=0.800,P=0.000);According to the interview results,the most common psychiatric problems cancer patients have adjustment disorder,depression,and anxiety.Conclusion:The data suggest that DT has acceptable overall accuracy and reliability as a screening tool for testing distress severity and specific problems causing distress in Chinese cancer patients.It is worth being used in oncology clinic,the rapid screening and interview could help caregivers to identify psychological and psychiatric problems of cancer patients and provide useful information for further treatment. 展开更多
关键词 VALIDATION RELIABILITY Cancer patients Distress thermometer
在线阅读 下载PDF
A highly sensitive luminescent metal-organic framework thermometer for physiological temperature sensing 被引量:7
9
作者 Lin Zhang Yadan Xie +3 位作者 Tifeng Xia Yuanjing Cui Yu Yang Guodong Qian 《Journal of Rare Earths》 SCIE EI CAS CSCD 2018年第6期561-566,共6页
Thermal sensing and imaging in the physiological temperature range are of great importance for studying physiological processes and treating diseases. Metal-organic frameworks(MOFs) exhibit great promise for developin... Thermal sensing and imaging in the physiological temperature range are of great importance for studying physiological processes and treating diseases. Metal-organic frameworks(MOFs) exhibit great promise for developing luminescent thermometers due to their remarkable structural diversities and tunable luminescence properties. Here, we synthesized a series of luminescent mixed-lanthanide MOFs,EuTbBPT(x = 0.019, 0.058, 0.106; H3 BPT = biphenyl-3,4’,5-tricarboxylate acid) and adopted powder X-ray diffraction(PXRD), thermogravimetric analysis(TGA) and Fourier transform infrared(FT-IR) to characterize the resulting products. The temperature-dependent photoluminescence emission spectra were recorded to investigate their potential applications in physiological temperature readout. It is found that the intensity ratio of Tbto Euis linearly correlated with temperature and the relative sensitivity is higher than 1.5%/℃ over the entire physiological temperature range. Furthermore,the temperaturedependent luminescence color emission allows for visual colorimetric temperature measurements.Luminescence lifetime testing and triplet energy level measurement were further conducted to study the mechanism. 展开更多
关键词 Lanthanide metal-organic frameworks Luminescent thermometer RATIOMETRIC COLORIMETRIC High sensitivity Physiological temperature
原文传递
Validity of distress thermometer for screening of anxiety and depression in family caregivers of Chinese breast cancer patients receiving postoperative chemotherapy 被引量:7
10
作者 Min Yang Fei Ma +3 位作者 Bo Lan Jianqiang Cai Xiaoying Sun Binghe Xu 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2020年第4期476-484,共9页
Objective:Family caregivers(FCs)of breast cancer patients play a vital role throughout the treatment process.Psychological distress of FCs is common and often ignored.A simple and effective instrument for screening ps... Objective:Family caregivers(FCs)of breast cancer patients play a vital role throughout the treatment process.Psychological distress of FCs is common and often ignored.A simple and effective instrument for screening psychological distress would help in selecting those FCs requiring special attention and intervention.Here,the validity of distress thermometer(DT)in FCs of Chinese breast cancer patients receiving postoperative chemotherapy was assessed,and the prevalence of anxiety and depression was evaluated.Methods:We recruited 200 FCs of hospitalized breast cancer patients in this cross-sectional descriptive study.Before the first cycle of adjuvant chemotherapy,the levels of anxiety and depression among FCs were assessed using DT and Hospital Anxiety and Depression Scale(HADS).In total,191 valid cases were analyzed.HADS was used as the diagnostic standard to assess the effectiveness of DT as a screening tool for anxiety and depression as well as to analyze the diagnostic efficiency of DT at various cutoff points.Results:The definitive prevalence of both anxiety and depression was 8.90%.The mean level of anxiety and depression among FCs was 5.64±3.69 and 5.09±3.85,respectively,both of which were significantly higher than corresponding Chinese norms(P<0.01).The areas under receiver operating characteristic curves of DT for the diagnoses of FCs'anxiety and depression were 0.904 and 0.885,respectively.A cutoff value of 5 produced the best diagnostic effects of DT for anxiety and depression.Conclusions:The levels of both anxiety and depression were higher in the FCs of Chinese breast cancer patients receiving postoperative chemotherapy than the national norm.DT might be an effective tool to initially screen psychological distress among FCs.This process could be integrated into the palliative care of breast cancer patients and warrant further research. 展开更多
关键词 Breast cancer distress thermometer ANXIETY DEPRESSION
暂未订购
Temperature of Prograde Metamorphism, Decompressional Partial Melting and Subsequent Melt Fractional Crystallization in the Weihai Migmatitic Gneisses,Sulu UHP Terrane:Constraints from Ti-in-Zircon Thermometer 被引量:5
11
作者 续海金 叶凯 章军锋 《Journal of Earth Science》 SCIE CAS CSCD 2012年第6期813-827,共15页
In order to constrain temperature during subduction and subsequent exhumation of fel- sic continental crust, we carried out a Ti-in-zircon thermometer coupled with zircon internal structure and U-Pb age on migmatitic ... In order to constrain temperature during subduction and subsequent exhumation of fel- sic continental crust, we carried out a Ti-in-zircon thermometer coupled with zircon internal structure and U-Pb age on migmatitic gneisses from the Weihai region in the Sulu ultra-high pres- sure (UHP) metamorphic terrane, eastern China. The Weihai migmatitic gneisses are composed of in- tercalated compositional layers of melanosome and plagioclase (Pl)-rich lencosome and K-feldspar (Kfs)-rich pegmatite veins. Four stages of zircon growth were recognized in the Weihai migmatitic gneisses. They successively recorded informations of protolith, prograde metamorphism, decompres- sional partial melting during early stage exhumation and subsequent fractional crystallization of pri- mary melt during later stage cooling exhumation. The inherited cores in zircon from the melanosome and the Pl-rich leucosome suggest that the pro- tolith of the migmatitic gneiss is Mid- Neoproterozoic (-780 Ma) magmatic rock. Metamorphic zircons with concordant ages ranging from 243 to 256 Ma occur as over- growth mantles on the protolith magmatic zir- con cores. The estimated growth temperatures (625-717 "C) of the metamorphic zircons have a negative correlation with their ages, indicating a progressive metamorphism in HP eciogite-facies condition during subduction. Zircon recrystal- lized rims (228-2 Ma) in the PI-rich ieucosome layers provide the lower limit of the decompress-sional partial melting time during exhumation. The ages from 228^-2 to 219~2 Ma recorded in the Pl-rich leucosome and the Kfs-rich pegmatite vein, respectively, suggest the duration of the fractional crystallization of primary melt during exhumation. The calculated growth temperatures of the zircon rims from the Pl-rich leucosome range from 858 to 739 , and the temperatures of new growth zircon grains (219±2 Ma) in Kfs-rich vein are between 769 and 529 . The estimated temperatures have a positive correlation with ages from the Pl-rich leucosome to the Kfs-rich pegmatite vein, strongly indi- cating that a process of fractional crystallization of the partial melt during exhumation. 展开更多
关键词 Ti-in-zircon thermometer prograde metamorphism decompressional partial melting fractional crystallization migmatitic gneiss Sulu UHP metamorphic terrane.
原文传递
Multi-site occupancies and dependent photoluminescence of Ca_(9)Mg_(1.5)(PO_(4))_(7):Eu^(2+) phosphors:A bifunctional platform for optical thermometer and plant growth lighting 被引量:4
12
作者 Ruiyu Mi Yan-gai Liu +4 位作者 Lefu Mei Zhaohui Huang Minghao Fang Xiaowen Wu Xin Min 《Journal of Rare Earths》 SCIE EI CAS CSCD 2023年第10期1503-1511,I0002,共10页
Herein,we demonstrate an optical thermometer based on single Eu^(2+)doped Ca_(9)Mg_(1.5)(PO_4)_7 phosphors,which were prepared by traditional solid-state reaction technique under a reduction atmosphere.Considerations ... Herein,we demonstrate an optical thermometer based on single Eu^(2+)doped Ca_(9)Mg_(1.5)(PO_4)_7 phosphors,which were prepared by traditional solid-state reaction technique under a reduction atmosphere.Considerations on the bond length obtained by the crystal structure refinement and the dependent photoluminescence performances allow to assign the two distinct emission bands to Eu^(2+)ions occupied Cal-Ca3 and Mg2 sites.Moreover,the blue and red emitting bands perfectly match with the photosynthetic action spectrum,which can enhance the indoor plant photosynthesis.The optimal doping content of Eu^(2+)ions in this Ca_(9)Mg_(1.5)(PO_(4))_(7)system is 3 mol%.The corresponding concentration quenching effect is verified as dipole-dipole interaction with the critical distance of 3.315 nm.Furthermore,by exploiting the fluorescence intensity technique,the optical thermal resistance properties of Ca_(9)Mg_(1.5)(PO_4)_7:Eu^(2+)are identified based on the temperature dependent emission spectra in a range of 303-523 K.In detail,the maximum absolute and relative sensitivity S_(a)and S_(r)of Ca_9Mg_(1.5)(PO_(4))_(7):Eu^(2+)thermometer are as high as 0.637%/K and 0.3155 K^(-1),respectively.Consequently,the Eu^(2+)doped Ca_(9)Mg_(1.5)(PO_(4))_(7)phosphors establish a bifunctional platfo rm for both optical the rmometer and plant growth lighting via multi-site occupancies. 展开更多
关键词 Eu^(2+)site occupancies PHOTOLUMINESCENCE Plant growth lighting Fluorescence intensity ratio thermometer Rare earths
原文传递
Smart nanoprobe based on two-photon sensitized terbium-carbon dots for dual-mode fluorescence thermometer and antibacterial 被引量:3
13
作者 Huicheng Yan Hongyuhang Ni +7 位作者 Yiwei Yang Changfu Shan Xiaoxi Yang Xiangkai Li Jing Cao Wenyu Wu Weisheng Liu Yu Tang 《Chinese Chemical Letters》 SCIE CAS CSCD 2020年第7期1792-1796,共5页
Accurate temperature measurement plays an important role in a variety of industrial processes and scientific researches.In our work,the dual-mode temperature response nanoprobe CDs-Tb-TMPDPA containing a two-photon li... Accurate temperature measurement plays an important role in a variety of industrial processes and scientific researches.In our work,the dual-mode temperature response nanoprobe CDs-Tb-TMPDPA containing a two-photon ligand(4-(2,4,6-trimethoxyphenyl)-pyridine-2,6-dicarboxylic acid,TMPDPA)sensitized Tb3+as a temperature-sensitive unit and carbon dots(CDs)as photothermal reagent and a fluorescence reference unit,have been designed and synthesized.In this system,both the fluorescence intensity ratio and the fluorescence lifetime have a good response to temperature.In additio n,due to the excellent photothermal conversion capability of CDs,photothermal antibacterial ability was also tested.Based on the temperature dependence of the fluorescence and the two-photon excitation characteristics of CDs-Tb-TMPDPA,the nanoprobe can also be used in the anti-counterfeiting.Our finding opens a new prospect for the use of two-photon sensitized dual-mode fluorescence thermometers. 展开更多
关键词 Rare-earth Fluorescence lifetime Fluorescence intensity thermometer ANTIBACTERIAL
原文传递
A Thermometer Based on Diverse Types Thermocouples and Resistance Temperature Detectors 被引量:2
14
作者 朱敏玲 《Journal of Shanghai Jiaotong university(Science)》 EI 2015年第1期93-100,共8页
A universal and low-cost temperature thermometer is realized via a special circuit,integrated circuit chip with microprocessor and analog to digital converter,and digital bus interface.Various thermocouples and resist... A universal and low-cost temperature thermometer is realized via a special circuit,integrated circuit chip with microprocessor and analog to digital converter,and digital bus interface.Various thermocouples and resistance temperature detectors used for temperature sensing may be connected to same thermometer.A special signal condition circuitry is designed and a matching algorithm is proposed.A novel calibration method named disassembled calibration is proposed in order to enhance efficiency and flexibility for the whole system.Additionally,it presents a combination method of low order polynomial fitting and piecewise linearity for the nonlinearity calibration of the thermocouple and the resistance temperature detector.A cold junction compensation based on digital way is described.And the matching algorithm and calibration method may eliminate errors stemming from excitation voltage source and reference voltage source,and can weaken quantization error of analog to digital converter and drift of components,too.Furthermore,the 400 times oversampling is completed by sequential and equal interval sampling to upgrade accuracy of analog to digital converter from original 12 to 15 bits and to raise signal-to-noise ratio.Finally,during a long time monitoring,experiment results show that errors at each static point are less than±0.2°C for the thermocouple system and less than±0.1°C for the resistance temperature detector system. 展开更多
关键词 temperature thermometer THERMOCOUPLE resistance temperature detector calibration cold junction compensation algorithm signal condition circuitry
原文传递
Intestinal obstruction due to migration of a thermometer from bladder to abdominal cavity:A case report 被引量:1
15
作者 Jing Nie Bo Zhang +5 位作者 Yan-Chao Duan Yue-Hua Hu Xin-Ying Gao Jian Gong Ming Cheng Yan-Qing Li 《World Journal of Gastroenterology》 SCIE CAS 2014年第9期2426-2428,共3页
Intraperitoneal foreign bodies such as retained surgical instruments can cause intestinal obstruction.However,intestinal obstruction due to transmural migration of foreign bodies has rarely been reported.Here,we repor... Intraperitoneal foreign bodies such as retained surgical instruments can cause intestinal obstruction.However,intestinal obstruction due to transmural migration of foreign bodies has rarely been reported.Here,we report a case of intestinal obstruction due to a clinical thermometer which migrated from the bladder into the abdominal cavity.A 45-year-old man was admitted to our hospital with a one-year history of recurrent lower abdominal cramps.Two days before admission,the abdominal cramps aggravated.Intestinal obstruction was confirmed with upright abdominal radiography and computerized tomography scan which showed dilation of the small intestines and a thermometer in the abdominal cavity.Then laparotomy was performed.A scar was observed at the fundus of the bladder and a ther-mometer was adhering to the small bowels and mesentery which resulted in intestinal obstruction.Abdominal cramps were eliminated and defecation and flatus recovered soon after removal of the thermometer. 展开更多
关键词 Intestinal obstruction Foreign body thermometer Transmural migration BLADDER
暂未订购
Does central tympanic membrane perforation affect infrared tympanic thermometer measurements in adults? 被引量:1
16
作者 Hamdi Tasli Mert Cemal Gokgoz 《Journal of Otology》 CSCD 2018年第4期128-130,共3页
Objective: Infrared Tympanic Thermometer(ITT) is one of the most useful instruments for accurately measuring temperature. The effects of ear pathologies on ITT measurement remain unclear. The purpose of this study is ... Objective: Infrared Tympanic Thermometer(ITT) is one of the most useful instruments for accurately measuring temperature. The effects of ear pathologies on ITT measurement remain unclear. The purpose of this study is to determine if tympanic membrane perforation(TMP) affects ITT measurements in adult patients.Material and methods: A total of 90 adult patients with monaural central TMP were enrolled in this study.Patients were categorized into three subgroups according to perforation size(1-3 mm, 4-7 mm, and 8-10 mm).The tympanic temperatures of the affected and unaffected sites, and subgroups were compared with each other.Results: This study contained 54(60%) males and 36(40%) females ranging from 20 to 58 years of age(mean age: 30.74 ± 9.61 years). The mean tympanic temperature of the side affected with TMP was 36.34 oC ± 0.61 oC.The mean tympanic temperature of the unaffected side with healthy and intact tympanic membrane was 36.33 oC ± 0.6 oC. The Pearson correlation score for the tympanic temperatures and the size of TMP was 0.22 which was not significant(r=-0.12).Conclusion: TMP and perforation size do not affect ITT measurements in adult patients. 展开更多
关键词 Tympanic membrane PERFORATION Infrared tympanic thermometer Body temperature
暂未订购
Application of Distress Thermometer in Patients with Prostatic Cancer and Prostatitis 被引量:2
17
作者 Xin Wang Chang-Xuan Chen +1 位作者 Qian Wang Lei Wang 《Open Journal of Urology》 2017年第12期227-234,共8页
Objective: To discuss the application of distress thermometer (DT) on psychological pain in primary hospital patients with prostatic cancer (Pca) and prostatitis;and to analyze the present status and related factors o... Objective: To discuss the application of distress thermometer (DT) on psychological pain in primary hospital patients with prostatic cancer (Pca) and prostatitis;and to analyze the present status and related factors of psychological pain in these patients. Methods: Questionnaire survey of DT and related problem lists were carried out in 168 patients with Pca and 226 patients with prostatitis. The data were input to EXCEL and analyzed with SPSS 18.0. The statistical description was used to analyze the graded of psychological pain. Square test and Logistic regression were used to analyze influence factors of significant psychological distress. Pearson correlation analysis was used to assess the correlation between psychological distress and related problems. Results: Psychological pain score of Pca patients and prostatitis patients were 3.42 ± 1.86 and 3.02 ± 1.75, respectively. Moderate to severe degree of pain accounted for 69.6% in Pca patients, compared to 49.1% in prostatitis patients. In Pca and prostatitis patients, marital status, age, educational backgrounds and income were associated. Physical and emotional problems were the top two items having the highest score. Psychological distress score was positively correlated with physical problems, emotional problems, practical problems and communication problems in both Pcar and prostatitis patients. Conclusion: The Distress Thermometer can be used to assess the severity and explore the causes of psychological distress in Pca patients and prostatitis patients. Our study could help detecting the degree and reason of psychological distress, and provide evidence for the possibility of future personalized intervention to treat medical mental problems in primary hospital. 展开更多
关键词 PROSTATIC Cancer PROSTATITIS PSYCHOLOGICAL DISTRESS PSYCHOLOGICAL DISTRESS thermometer SCALE
暂未订购
Influence of dysprosium concentration on sensitivity of luminescent thermometers of phosphors Ca_(9)Tb(PO_(4))_(5)(SiO_(4))F_(2) 被引量:1
18
作者 Jingxue Zhang Lefu Mei +3 位作者 Yuanyuan Zhang Qingfeng Guo Libing Liao Haikun Liu 《Journal of Rare Earths》 SCIE EI CAS CSCD 2021年第8期946-951,共6页
Tb^(3+),Dy^(3+)-co-doped Ca_(9)Tb_(x)Dy_(1-x)(PO_(4))_(5)(SiO_(4))F_(2) phosphors were prepared via high-temperature solidphase reaction method and the potential application in optical temperature measurements due to ... Tb^(3+),Dy^(3+)-co-doped Ca_(9)Tb_(x)Dy_(1-x)(PO_(4))_(5)(SiO_(4))F_(2) phosphors were prepared via high-temperature solidphase reaction method and the potential application in optical temperature measurements due to their color-tunable property was investigated in detail.The photoluminescence emission(PL) and photoluminescence excitation(PLE) spectra results show that the as-prepared phosphors exhibit both Tb^(3+) and Dy^(3+) emissions at 546 nm(^(5)D_(4)-^(7)F_(5) transition of Tb^(3+)) and 587 nm(^(4)F_(9/2)-^(6)H_(13/2) transition of Dy^(3+)) upon 376 nm excitation,respectively.In addition,the fluorescence decay analysis shows that the lifetime of the Tb3+emission rapidly decreases,which confirms the energy transfer existence between Dy^(3+) and Tb^(3+).Under 376 nm excitation,the temperature dependence of the fluorescence intensity ratios for the dualmission bands peaked at 546 and 587 nm was studied in the temperature range from 303 to 573 K.The results show that with the increase of Dy^(3+) concentration,the relative sensitivity first increases and then decreases,what’s more,the maximum relative sensitivity is 3.142×10^(-3)%/K for Ca_(9)Tb_(x)Dy_(1-x)(PO_(4))_(5)(SiO_(4))F_(2)(x=0.4).As a consequence,this preliminary study provides a novel method for exploring the novel thermo meters. 展开更多
关键词 Temperature measurement APATITE Fluorescence intensity ratios PHOSPHOR thermometerS Rare earths
原文传递
Application of a Modified Distress Thermometer to Screen for Psychological Distress in 140 Patients with Malignancies,and an Analysis of Related Factors 被引量:1
19
作者 Ge Zhu Guang Yang +2 位作者 Dong Sheng Xu Hong Wei Li Nan Ya Wang 《Journal of Nutritional Oncology》 2018年第1期39-44,共6页
Objective A modified Distress Thermometer(DT)was applied to explore the status of psychological distress in patients with malignant tumors and to analyze the related factors influencing psychological distress.Methods ... Objective A modified Distress Thermometer(DT)was applied to explore the status of psychological distress in patients with malignant tumors and to analyze the related factors influencing psychological distress.Methods The modified DT was used to screen for psychological distress in 140 patients with malignant tumors in the Cancer Center of the First Hospital of Jilin University.Aχ2 test was used to analyze the effects of age and gender on psychological distress;risk factors associated with significant psychological distress(DT≥4)were further analyzed by Stepwise Logistics Regression.Spearman’s Correlation Analysis was used to determine the correlations among the items in the problems list(economic problems,fatigue,eating,pain,nausea,constipation,decreased memory/inattention,anxiety,tension,sleep).Results The results of the modified DT screening showed that the rate of significant psychological distress was 33.57%in patients with malignant tumors,and females and elderly patients were more likely to suffer significant psychological distress(P=0.048;P=0.002).A dry/congestive nose,depression,having to work/go to school,bathing/dressing,and nausea were significant factors or situations associated with psychological distress in patients with malignant tumors,and physical and emotional problems often appeared together in the problems list.Conclusion The modified DT reflected the degree of each symptom(to a certain extent),and could accurately and concretely identify the major cause(s)of the patients’psychological distress,so that the clinical medical care workers could target the problems and improve the patients’quality of life. 展开更多
关键词 DISTRESS thermometer MALIGNANT tumor PSYCHOLOGICAL DISTRESS
在线阅读 下载PDF
A Luminescent Thermometer Based on Linearly Thermo-responsive Copolymer and Polyoxometalates
20
作者 Jin-Long Zhang Jun-Yan Tan +1 位作者 Xin-Hua Wan Jie Zhang 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2019年第11期1113-1118,共6页
A novel switchable luminescent thermometer based on thermo-responsive triblock copolymer poly(ethylene glycol)-bpoly(acrylamide-co-acrylonitrile-co-dimethylaminoethylmethacrylate)(PEO113-b-P(AAm264-co-AN112-co-DMA8)) ... A novel switchable luminescent thermometer based on thermo-responsive triblock copolymer poly(ethylene glycol)-bpoly(acrylamide-co-acrylonitrile-co-dimethylaminoethylmethacrylate)(PEO113-b-P(AAm264-co-AN112-co-DMA8)) and Eu-containing polyoxometalate (Eu-POM) was successfully constructed.The copolymer synthesized by RAFT exhibited a linear response to temperature variations in aqueous media,which was quite different from the uncharged copolymer P(AAm-co-AN) having a specific upper critical solution temperature (UCST).Eu-POM was surrounded around thermo-responsive blocks through electrostatic interactions,and its luminescence could be finely tuned due to the sensitivity of copolymer to the temperature variation.In cold water,POMs were trapped in highly hydrophobic cores,exhibiting an intense emission.With the upraising of temperature,the emission intensity presented a gradual decrease and showed a linear correlation with temperature.When the complex solution cooled down,the luminescence could also be perfectly restored.This temperature-luminescence correlation could be held for numerous trials,showing a potential application in thermometer. 展开更多
关键词 LUMINESCENT thermometer Block COPOLYMER Polyoxometalate UCST
原文传递
上一页 1 2 4 下一页 到第
使用帮助 返回顶部